U.S. EPA. 2015. Review of WIPP Performance Assessment Computer Code Migration Activities. Prepared by the Office of Radiation and Indoor Air. Washington, DC. July
Other documents for the same rulemaking
References: 392 extracted, 0 linked to papers
[9] WIPP PA – “ORIGEN-S, User’ Manual, Revision 3”, INV-OGS-02, dated June 7, 2011. Los Alamos National Laboratory – Carlsbad, New Mexico.
[10] WIPP PA – ORIGEN-S Requirements Document, Revision 1, dated May 16, 2011. Los Alamos National Laboratory – Carlsbad, New Mexico. 1.1.177TransOrigen **NOTE: Functionality incorporated into CID database software. 5.36.2.1 Introduction Please Note: In 2014, EPA reviewed LANL’s ORIGEN (ORIGEN-S, newest version) and CID documentation related to the TransOrigen code. LANL incorporated all of TransOrigen’s functionality into the CID database software. The new CID database software imports input files and exports ORIGEN-S results directly. The Agency focused its 2014 review on the changes to the CID database and software. The Agency left this section of the report unchanged to preserve historical review information. TransOrigen is a Microsoft Excel-based automation tool used to efficiently execute the ORIGEN2, Version 2.2 software in a batch sequence (once per waste stream), and compile the output data from all executions into a single spreadsheet. The input for the execution is exported from the Comprehensive Inventory Database (CID). TransOrigen writes a series of ORIGEN input files containing the input data. Following the execution of ORIGEN on each of the files, the output data are transferred into a single “results” sheet within TransOrigen. The CID subsequently imports these results for reporting purposes.
LANL-CO Quality Assurance (QA) Program in December of 2006, in accordance with LANLCO Software Quality Assurance Plan, Revision 1
Software, Revision 0, LCO-QP19-1 [4]. ORIGEN2, Version 2.2 was qualified for use as adopted software under the LANL-CO QA Program in August of 2007, in accordance with LANL-CO Software Quality Assurance Plan, Revision 2
[5] and Software Quality Assurance, Revision 1 [6]. This unit conversion and data transfer activity is accomplished using a utility named “TransOrigen,” a Microsoft Excel 2003 workbook file (TransOrigen.xls) designed to Computer Code TSD July 2015 accommodate the batch unit conversion and transfer of isotopic data, decay corrected using the ORIGEN2, Version 2.2 software. TransOrigen employs Excel macros and code modules, written in Visual Basic for Applications (VBA), to perform calculations and transfer data between tabular spreadsheets and ASCII text files, which are the basis for the ORIGEN2, Version 2.2 input and output files. In addition, TransOrigen makes use of a Microsoft Access 2003 database (TransOrigen.mdb) table to boost processing performance. Appendix I of the Analysis Report provides a detailed description and application of the use of the workbook [1]. The testing of TransOrigen was performed on a workstation with the following characteristics:
GB RAM 212 GB HD Operating System: Microsoft® Windows XP Professional Version 2002 Service Pack 3 Software: Microsoft Office Excel 2003 SP3 Microsoft Office Access 2003 SP3 Comprehensive Inventory Database v.1.00 S.1.00, data version D.7.00
LANL performed a separate validation execution to demonstrate that the pre- and postprocessing data transfers are functioning as intended. The “20081112_Val” folder (included in the electronic media associated with this analysis) contains the files pertaining to this execution. In order to demonstrate the TransOrigen utility functions properly, a set of input data were decayed by ORIGEN2, Version 2.2 for a decay period of 0 (zero) years. This dataset is essentially the CID data version D.7.00 radionuclide data, with the exception that all generation years have been explicitly set to 2007, with decay thru the year 2007. The intent of this execution is to compare the input dataset with the output dataset for equivalency. Any discrepancies were to be documented and an explanation given. The acceptance criteria for validation are that no radionuclide data are lost as a result of the pre- and post-processing transfer. Exceptions to these criteria are if the data are intentionally removed (i.e., an input activity concentration of zero Ci/m3), and if the data is lost because of limitations related to the TransOrigen utility (i.e., gram parameters cannot be smaller than 1.00E-24 or larger than 1.00E+38).
[1] LANL 2008. TransOrigin Unit Conversion and Data Transfer for the 2007 TRU Waste Inventory. Analysis Report. INV-SAR-14. Los Alamos National Laboratory – Carlsbad Operations.
[2] LANL 2008. Software Quality Assurance Plan, Revision 3, LCO-QPD-02, Carlsbad, New Mexico. Los Alamos National Laboratory – Carlsbad Operations (LANL – CO).
[4] LANL 2005. Software Quality Assurance Plan, Revision 1, LCO-QPD-02, Carlsbad, New Mexico. Los Alamos National Laboratory – Carlsbad Operations (LANL–CO).
[5] LANL 2007. Quality Assurance for Developed Software, Revision 0, LCO-QP19-1,
Carlsbad, New Mexico. Los Alamos National Laboratory – Carlsbad Operations (LANL–CO). Computer Code TSD July 2015
[6] LANL 2007. LANL-CO Software Quality Assurance Plan, Revision 2, LCO-QPD-02,
[7] LANL 2008. Comprehensive Inventory Database, v.1.00, S.1.00, data version D.7.00,
[8] LANL 2008. Analysis Plan for Transuranic Waste Inventory, Revision 3, INV-AP-01,
[9] LANL 2008. Analyses, Revision 3, LCO-QP9-1, Carlsbad, New Mexico. Los Alamos National Laboratory – Carlsbad Operations (LANL–CO).
[10] LANL 2007. Software Quality Assurance, Revision 3, LCO-QP19-1, Carlsbad, New Mexico. Los Alamos National Laboratory – Carlsbad Operations (LANL–CO).
LANL’s qualification of the CID database and software in 2014 as part of its 2014 CRA review. In 2011, LANL ran 75 test cases to qualify CID Version 2.00 on Windows computer hardware using Microsoft Office Access and Excel 2010 and Microsoft SQL Server 2008 database software. In 2012, eleven test cases were run on CID Version 2.01 to test changes due to database/software problems reported by users and change control proposals [15]. In 2013 sixteen test cases were run on CID Version 2.02 to also test database/software changes [16]. Various cases tested a number of requirements the CID database and software are expected to perform, as documented in the requirements document [11]. These requirements include data entry, data import, manual data lookup, ORIGEN-S interface, report generation and other inventory related activities [11]. Functionality of TransOrigen was moved to the CID software. These functions were tested by a number of test cases, such as TC-018 and TC-083 [16]. The approach used by LANL is similar to that described in this report as described in
MS Windows 2000 Professional SP4 MS Access 2003 Dell Latitude Laptop Property No. 1098668 PN1163363
MS Windows XP Professional ver. 2002 SP2 E-CO2
MS Excel 2003 Property No. 1163363 Server Screen Resolution Used 1024x768 pixels
MS Windows Server 2003 Standard SP1 MS SQL Server 2000 Standard Property No. 1145676 Computer Code TSD July 2015 To perform the testing, a synthetic dataset was developed to provide a sample set of parameters to test the report generation function. This synthetic dataset was installed as part of the first test case execution (i.e., Test Case TC-001) and designated the “CIDFull” database, which included the parameters necessary to test the reporting requirements. Although this dataset was designed to include enough variations in parameters to adequately test the reports, it is not inclusive of every possible combination of parameters. One simplification in the dataset is that the radionuclide concentrations are not decayed through time. Although this assumption does not simulate actual conditions, the DOE believes (and the Agency agrees) that for the purposes of testing, it is acceptable. The parameters that comprise the synthetic dataset are provided in Appendix B of the VD [8]. The data entry requirements that were not tested on the “CIDFull” dataset were tested in other individual test cases. In 2006, all the test cases were executed by first running the first two test cases (i.e., TC-011 and
EPA closely examined the results of LANL’s CID qualification activities and found that their work thoroughly tested the many requirements for the CID database and database software. As previously performed, some test cases were rerun to verify problems found during the first Computer Code TSD July 2015 execution of these test and were properly corrected (for example, test cases TC-076, TC-080,
[1] U.S. Department of Energy, 1995, Waste Isolation Pilot Plant Transuranic Waste Baseline Inventory Report, Revision 1, CAO-94-1005, February 1995.
[2] DOE 1996. Transuranic Waste Baseline Inventory Report. Revision 3, June 1996,
[3] DOE 2006. Transuranic Waste Baseline Inventory Report – 2004. Revision 0,
DOE/TRU-2006-3344, U.S. Department of Energy – Carlsbad Field Office, Carlsbad, New Mexico.
[4] LANL 2006. Requirements Document (RD), INV-CID-01, Requirements Document for the Comprehensive Database. Los Alamos National Laboratory – Carlsbad Operations,
[5] LANL 2006. Verification and Validation Plan (VVP), INV-CID-02, Verification and Validation Plan for the Comprehensive Inventory Database. Los Alamos National Laboratory – Carlsbad Operations, Carlsbad, New Mexico.
[6] LANL 2006. Design & Implementation Document (DD & ID or DID), INV-CID-03, Design & Implementation Document for the Comprehensive Inventory Database. Los Alamos National Laboratory – Carlsbad Operations, Carlsbad, New Mexico.
[7] LANL 2006. User’s Manual (UM), INV-CID-04, User’s Manual for the Comprehensive Inventory Database. Los Alamos National Laboratory – Carlsbad Operations, Carlsbad, New Mexico.
[8] LANL 2006. Validation Document (VD), INV-CID-05, Validation Document for the Comprehensive Inventory Database. Los Alamos National Laboratory – Carlsbad
[9] LANL 2007. Software Quality Assurance, Revision 3, LCO-QP19-1, Carlsbad, New Mexico. Los Alamos National Laboratory – Carlsbad Operations (LANL–CO).
[10] LANL 2002. Software Quality Assurance, Revision 1, LCO-QP19-1, Carlsbad, New Mexico. Los Alamos National Laboratory – Carlsbad Operations (LANL–CO). Computer Code TSD July 2015
[11] LANL 2011. Requirements Document for the Comprehensive Inventory Database, Revision 5, INV-CID-01, dated July 18, 2011, Carlsbad, New Mexico. Los Alamos National Laboratory – Carlsbad Operations (LANL–CO).
[12] LANL 2011, Verification & Validation Plan and Validation Document for the Comprehensive Inventory Database, Revision 2, INV-CID-02, dated July 28, 2011,
[13] LANL 2014, Design & Implementation Document for the Comprehensive Inventory Database. Revision 3, INV-CID-03, dated January 10, 2014, Carlsbad, New Mexico. Los Alamos National Laboratory – Carlsbad Operations (LANL–CO).
[14] LANL 2013, User’s Manual for the Comprehensive Inventory Database, Revision 2,
INV-CID-04, dated December 19, 2013, Carlsbad, New Mexico. Los Alamos National Laboratory – Carlsbad Operations (LANL–CO).
[15] LANL 2012, Validation Document for the Comprehensive Inventory Database version v.2.01 S.2.01, Revision 0, INV-CID-06, dated March 10, 2012, Carlsbad, New Mexico. Los Alamos National Laboratory – Carlsbad Operations (LANL–CO).
[16] LANL 2013, Validation Documentation for the Comprehensive Inventory Database version v.2.02 S.2.02, Revision 0, INV-CID-07, dated December 19, 2013, Carlsbad, New Mexico. Los Alamos National Laboratory – Carlsbad Operations (LANL–CO). Computer Code TSD July 2015 Summary and Conclusions In 2006, SNL procured four Compaq ES47 machines to add to the computing resources of two Compaq ES40 and two Compaq ES45 machines. In addition to the hardware upgrades, the operating system OpenVMS 7.3-1 has been upgraded to OpenVMS 8.2. The 31 computer codes and 5 libraries and 3 databases that were used to support the 2009 CRA and 2009 PABC calculations were on the Compaq ES40, ES45, and ES47 machines with OpenVMS 8.2 (Table 3.1-1). After completing the Agency’s review, the Agency concludes that the versions of the computer codes indicated in Table 3.1-1 are approved for use in compliance calculations for the
WIPP PA on the Compaq ES40, ES45, and ES47 machines with OpenVMS 8.2. In 2013, SNL qualified six of the WIPP PA codes for use in the 2014 recertification application (2014 CRA) on the Compaq ES45 and ES47 computers using OpenVMS 8.2. SNL also migrated the entire WIPP PA to the Solaris Blade platform with SunOS 5.11. SNL/DOE established a new PA baseline (PABC09) entirely on the Solaris Blade Platform using SunOS 5.11 and performed integration tests to verify that the Solaris PA system generates adequate PA results. EPA concludes from its review that the WIPP PA codes are approved for use in the 2014