U.S. EPA. 2015. Review of WIPP Performance Assessment Computer Code Migration Activities. Prepared by the Office of Radiation and Indoor Air. Washington, DC. July
Other documents for the same rulemaking
References: 392 extracted, 0 linked to papers
[18] WIPP PA – “Analysis Plan for Migration of the Performance Assessment Codes to the Sun Solaris Blade Server Running with Intel Processors, Revision 0 dated June 12, 2012.” Sandia National Laboratories. Sandia WIPP Central Files. ERMS# 557765.
[14] and the regression testing of DTRKMF 1.01 [11]. This document describes the working design of the software DTRKMF (Double precision TRacKing with MODFLOW 2000
DTRKMF code [11]. 1.1.38 Test Results For the two test cases in 2002, the domain of interest is a square that is 1,000 × 1,000 m2 long. The grid contains 400 cells—20 rows and 20 columns. The cell widths and heights vary from 100 × 100 m2 at the lower left-hand corner to 20 × 20 m2 at the upper right-hand corner. Three particles were released at coordinates (600,950), (650,950) and (8.5, 17.5). The coordinates for the third particle were specified by i-j index indicating the center of cell located in the 8th row and the 17th column. This corresponds to x-y coordinates equal to (621.8181, 946.1717). The Computer Code TSD July 2015 functional requirements were verified by a series of hand calculations, visual inspections of the data, and spreadsheets in 2002 validation testing. For the regression testing in 2014, results from the previous validation were compared to the 2014 cases run on the Solaris computer using the UNIX “diff” command. SNL found expected acceptable differences, such as file names and other text information. A few numeric values had
[1] Harbaugh, A.W., R.E. Banta, M.C. Hill, and M.G. McDonald, 2000. MODFLOW-2000,
[2] WIPP PA, 2002. WIPP PA Design Document for DTRKMF Version 1.00, Document Version 1.00; ERMS #523244, Sandia National Laboratories, Albuquerque, New Mexico.
[3] WIPP PA, 2002a. WIPP PA Requirements Document For DTRKMF Version 1.00, Document Version 1.00; ERMS #523242, Sandia National Laboratories, Albuquerque, New Mexico.
[4] WIPP PA, 2002b. WIPP PA Verification & Validation Plan For DTRKMF Version 1.00; Document Version 1.00; ERMS #523243, Sandia National Laboratories, Albuquerque, New Mexico.
[5] WIPP PA, 2002c. WIPP PA User’s Manual For DTRKMF (Version 1.00); Document Version 1.00; ERMS #523246, Sandia National Laboratories, Albuquerque, New Mexico.
[6] WIPP PA, 2000, WIPP PA Requirements Document For DTRKCDB (Version 1.00), Document Version 1.00; ERMS#515806, Sandia National Laboratories, Albuquerque, New Mexico.
[7] WIPP PA, 2002a, WIPP PA Requirements Document For DTRKMF Version 1.00, Document. Computer Code TSD July 2015
[8] WIPP PA, 2002b, WIPP PA User’s Manual For DTRKMF Version 1.00, Document Version 1.00; ERMS #523246, Sandia National Laboratories, Albuquerque, New Mexico.
[9] WIPP PA, 2002c, WIPP PA Verification and Validation Plan For DTRKCDB (Version 1.00), Document Version 1.00; ERMS #515089, Sandia National Laboratories,
[10] WIPP PA – “AP-168 - Analysis Plan for Migration of VMS files from the HP Alpha Cluster to the Sun/Solaris Cluster and Qualification of Codes from the Alice Linux Cluster on the Sun Solaris Cluster Revision 0, dated April 22, 2014.” Sandia National Laboratories. Sandia WIPP Central Files ERMS #561953.
Blade, dated August 5, 2014.” Sandia National Laboratories. Sandia WIPP Central Files
[12] WIPP-PA – “Implementation Document for DTRKMF Version 1.01, dated July 14, 2014.” Sandia National Laboratories. Sandia WIPP Central Files ERMS #562205.
[13] WIPP PA – “Validation Document for DTRKMF Version 1.00, dated April 2003.” Sandia National Laboratories. Sandia WIPP Central Files ERMS #523247.
[14] “Summary Report on the Migration of VMS files from the HP Alpha Cluster to the Sun/Solaris Cluster and Qualification of Codes from the Alice Linux Cluster on the Sun Solaris Cluster, AP-168, dated December 12, 2014.” Sandia National Laboratories. Sandia WIPP Central Files ERMS #563103.
[2] EPA 2003. “Review of WIPP Performance Assessment Computer Code Migration, June 10, 2003.” Environmental Protection Agency.
[3] WIPP PA – “Analysis Report for the ES45 Regression Test, March 6, 2003.” Sandia National Laboratories. Sandia WIPP Central Files. ERMS #530290.
[5] WIPP PA (Performance Assessment) 2003. “Design Document for EPAUNI Version 1.15.” Sandia National Laboratories. Sandia WIPP Central Files ERMS #529567.
[6] WIPP PA (Performance Assessment) 2003. “User’s Manual for EPAUNI Version 1.15.” Sandia National Laboratories. Sandia WIPP Central Files ERMS #529570.
[7] WIPP PA (Performance Assessment) 2003. “Validation Document for EPAUNI Version 1.15.” Sandia National Laboratories. Sandia WIPP Central Files ERMS #529568.
[8] WIPP PA (Performance Assessment) 2003. “Addenda to Validation Document for
[9] WIPP PA (Performance Assessment) 2003. “Analysis Report for EPAUNI Version 1.15A Regression Testing for the Compaq ES45 and 8400 Platforms.” Sandia National Laboratories. Computer Code TSD July 2015
[10] EPA 2004. “Review of WIPP Performance Assessment Computer Code Migration, March 31, 2004.” Environmental Protection Agency.
[12] WIPP PA – “Regression Testing Report of EPAUNI Version 1.15A on the Compaq ES40, ES45, and ES47 Platforms Using OpenVMS 8.2 dated June 19, 2006.” Sandia National Laboratories. Sandia WIPP Central Files. ERMS #543779.
Solaris, AP-162 dated December 23, 2013.” Sandia National Laboratories. Sandia WIPP Central Files ERMS #561457
[14] WIPP PA – “Addendum to Requirements Document, User’s Manual, Verification and Validation Plan and Validation Document for EPAUNI Version 1.16 dated March 28, 2013.” Sandia National Laboratories. Sandia WIPP Central Files ERMS #559075
[1] WIPP PA – “Verification and Validation Plan/Validation Document for EQ3/6 Version 8.0a for Actinide Chemistry, Revision 1, dated May 12, 2011.” Sandia National Laboratories. Sandia
[2] “Software User’s Manual EQ3/6, Version 8.0, dated January 2003.” By Thomas Wolery and Russell Jarek. Sandia National Laboratories. Sandia WIPP Central Files ERMS #548926.
[3] WIPP PA – “Requirements Document for EQ3/6 Version 8.0a for Actinide Chemsitry, dated July 2009.” Sandia National Laboratories. Sandia WIPP Central Files ERMS #550238. Please Note: FMT is replaced by EQ3/6. DOE migrated FMT to the Solaris to sustain chemical computation capability until EQ3/6 is adequately qualified. This section presents the regression test results for FMT. FMT calculates the chemical equilibrium in high-ionic-strength geochemical systems at 25 C. FMT also predicts solubility behavior of Am(III), Th(IV) and Np(V) in brines such as those found in Castile, Rustler, and Salado Formations near the WIPP. Computer Code TSD July 2015 1.1.51 Introduction
FMT 2.00 was validated in November 1995 on a DEC Alpha 2100 with OpenVMS 6.1 by demonstrating that the results of nine test cases met the acceptance criteria defined in the
FMT 2.41 regression testing showed some “numeric differences.” These numerical differences are within the acceptance criteria set for the regression testing of the FMT code. SNL reasonably explained these differences. The comparison found that all differences in output are acceptable. 1.1.54 The Agency’s Conclusions Computer Code TSD July 2015 The Agency found that all differences in output are acceptable; namely, that the differences are limited to code run date and time, platform names, system version numbers, the directory, file names, and some numeric differences. The Agency concludes that FMT 2.41 meets the acceptance criteria in the RD/VVP and is validated for WIPP PA use on the Solaris Blade with SunOS 5.11. 1.1.55 References
[1] WIPP PA (Performance Assessment) 1998. “Requirements Document & Verification and Validation Plan for FMT Version 2.40.” Sandia National Laboratories. Sandia
[2] WIPP PA (Performance Assessment) 1998. “Validation Document for FMT Version 2.40.” Sandia National Laboratories. Sandia WIPP Central Files WPO #51587.
[3] WIPP PA (Performance Assessment) 1995. “Requirements Document & Verification and Validation Plan for FMT Version 2.00.” Sandia National Laboratories. Sandia
[4] WIPP PA (Performance Assessment) 1995. “Validation Document for FMT Version 2.00.” Sandia National Laboratories. Sandia WIPP Central Files WPO #28121.
[5] WIPP PA (Performance Assessment) 1996. “FMT 2.1 Regression Testing Results.” Sandia National Laboratories. Sandia WIPP Central Files WPO #41011.
[6] WIPP PA (Performance Assessment) 1996. “Validation Document for FMT Version 2.20.” Sandia National Laboratories. Sandia WIPP Central Files WPO #41521.
[7] WIPP PA (Performance Assessment) 1996. “Requirements Document & Verification and Validation Plan for FMT Version 2.20.” Sandia National Laboratories. Sandia
[8] WIPP PA (Performance Assessment) 1997. “Validation Document for FMT Version 2.30.” Sandia National Laboratories. Sandia WIPP Central Files WPO #43038.
[9] WIPP PA (Performance Assessment) 1997. “Requirements Document & Verification and Validation Plan for FMT Version 2.30.” Sandia National Laboratories. Sandia
[10] Memorandum dated February 4, 2003. “Additional Evaluation of FMT Test Case 1.” Sandia National Laboratories. Sandia WIPP Central Files ERMS #525279.
[11] EPA 2003. “Review of WIPP Performance Assessment Computer Code Migration, June 10, 2003.” Environmental Protection Agency.
[12] WIPP PA – “Analysis Report for the ES45 Regression Test, March 6, 2003.” Sandia National Laboratories. Sandia WIPP Central Files. ERMS #530290.
[14] EPA 2004. “Review of WIPP Performance Assessment Computer Code Migration, March 31, 2004.” Environmental Protection Agency. Computer Code TSD July 2015
[15] WIPP PA – Validation (Performance Assessment) 2006. “Installation of OpenVMS Version 8.2-1 on the WIPP Alpha Cluster and Regression Testing, dated March 16, 2006.” Sandia National Laboratories. Sandia WIPP Central Files WPO #542680.
[16] WIPP PA – “Regression Testing Report of FMT Version 2.40 on the Compaq ES40, ES45, and ES47 Platforms Using OpenVMS 8.2 dated June 19, 2006.” Sandia National Laboratories. Sandia WIPP Central Files. ERMS #543779.
[18] WIPP PA – “Installation and Checkout for FMT Version 2.41 Regression Test for the Solaris Blade dated November 12, 2013.” Sandia National Laboratories. Sandia WIPP Central Files ERMS #560969.
[19] WIPP PA - “AP-162 Analysis Plan for Migration of the Performance Assessment Codes to the Sun Solaris Blade Server Running with Intel Processors, Revision 0 dated June 12, 2012.” Sandia National Laboratories. Sandia WIPP Central Files ERMS #557765.