Cecala et al. Dust
Other documents for the same rulemaking
References: 164 extracted, 0 linked to papers
USBM [1974]. Survey of past and present methods used to control respirable dust in noncoal mines and ore processing mills–final report. U.S. Department of the Interior, Bureau of Mines Contract No. H0220030. NTIS No. PB 240 662.
USBM [1986]. Impact of background sources on dust exposure of bag machine operator. By
USBM [1988]. Technology news 299: Reduce bagging machine operator's dust exposure by controlling background dust sources. U.S. Department of the Interior, Bureau of Mines.
USBM [2006]. Lower respirable dust and noise exposure with an open structure design. By
ASABE [2003]. Agricultural Cabs—Engineering Control of Environmental Air Quality, Part 1:
CDC [2000]. Notice to readers: NIOSH Alert; silicosis screening in surface coal miners—
Pennsylvania, 1996–1997. Cincinnati, OH: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health.MMWR Weekly 49(27):612–615.
Cecala AB, Zimmer JA [2004a]. Clearing the air. Aggregates Manager J 9(4):12–14.
Cecala AB, Zimmer JA [2004b]. Filtered recirculation—a critical component to maintaining acceptable air quality in enclosed cabs for surface mining equipment. Proceedings of 10th U.S./N.A. Mine Ventilation Symposium. Anchorage, Alaska. May 16–19, pp. 377–387.
Cecala AB, Organiscak JA, Heitbrink WA [2001]. Dust underfoot—enclosed cab floor heaters can significantly increase operator's respirable dust exposure. Rock Products 104(4):39–44.
Cecala AB, Organiscak JA, Heitbrink WA, Zimmer JA, Fisher T, Gresh RE, Ashley JD II [2004]. Reducing enclosed cab drill operator's respirable dust exposure at surface coal operations with a retrofitted filtration and pressurization system. SME Transactions 2003,
Coppock CC, Andrews EH [2005]. Reducing enclosed cab drill operator's respirable dust exposure with effective filtration and pressurization techniques. J of Occ and Env Hyg 2:54–63.
Cecala AB, Organiscak JA, Zimmer JA, Moredock D, Hillis M [2007]. Closing the door to dust when adding drill steels. Rock Products, October, pp. 29–32.
Chekan GJ, Colinet JF [2003]. Retrofit options for better dust control—cab filtration, pressurization systems prove effective in reducing silica dust exposures in older trucks. Aggregates Manager, December, 8(9):9–12.
Heitbrink WA, Thimons ED, Organiscak JA, Cecala AB, Schmitz M, Ahrenhottz E [2000]. Static pressure requirements for ventilated enclosures. Proceedings of the Sixth International Symposium on Ventilation for Contaminant Control, Helsinki, Finland, June 4–7. Logson R [1998/1999]. Controlling respirable dust in plant control rooms. Stone Review, The Bimonthly Publication of the National Stone Association. December 1998/January 1999, 14(6):43–44.
NIOSH [2001a]. Technology news 485: Improved cab air inlet location reduces dust levels and air filter loading rates. By Organiscak JA, Page SJ. Pittsburgh, PA: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health. Operator Booths, Control Rooms, and Enclosed Cabs 239
NIOSH [2001b]. Technology news 486: Floor heaters can increase operator's dust exposure in enclosed cabs. By Cecala AB, Organiscak JA. Pittsburgh, PA: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health.
NIOSH [2007]. Technology news 528: Recirculation filter is key to improving dust control in enclosed cabs. By Organiscak JA, Cecala AB. Pittsburgh, PA: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, DHHS (NIOSH) Publication No. 2008–100.
NIOSH [2008a]. Technology news 533: Minimizing respirable dust exposure in enclosed cabs by maintaining cab integrity. By Cecala AB, Organiscak JA. Pittsburgh, PA: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, DHHS (NIOSH) Publication No. 2008–147.
NIOSH [2008b]. Key design factors of enclosed cab dust filtration systems. By Organiscak JA,
Organiscak JA, Cecala AB [2008]. Laboratory investigation of enclosed cab filtration system performance factors. Min Eng 60(12):74–80.
Organiscak JA, Cecala AB, Thimons ED, Heitbrink WA, Schmitz M, Ahrenholtz E [2004].
SME Transactions 2003 Littleton, Colorado: Society for Mining, Metallurgy and Exploration, Inc., 314:145–152. 240 Operator Booths, Control Rooms, and Enclosed Cabs
HAUL ROADS Haul roads and access roads are used extensively in mining operations by mobile equipment to move material in and out of the mining areas. The road network at a surface mine site can be quite extensive over the entire property and the potential for dust generation is dependent upon the traffic patterns at the site. In areas where the traffic pattern is heavy, the possibility for dust generation is much higher than areas where the traffic pattern is light, creating areas of potentially high dust exposures. Overexposures to respirable dust can occur to both equipment operators and workers in the vicinity of the road. The majority of the fugitive dust is generated through the forces of the wheels on the road surface and by the turbulence created by the vehicles [Moosmüller et al. 2005].
STOCKPILES AND OPEN AREAS Stockpiles and open areas are common at surface mine sites. There are generally two types of stockpiles: long-term and short-term. A long-term stockpile undergoes no disturbance to the pile over a long time period (several months or more). An example would be a topsoil stockpile where topsoil is stored until reclamation of the mine site is 258 Haul Roads, Stockpiles, and Open Areas performed. Short-term stockpiles could consist of product or material that is being stored temporarily until it is used in a process. Surge piles are common short-term stockpiles. Open areas are self-explanatory as they are large barren areas. Dust can be generated from stockpiles and open areas by wind velocities that entrain material into the air. The United States Department of Agriculture states that erosion will take place when "the surface soil is finely divided, loose, and dry; the surface is smooth and bare; and the wind is strong." 9 As stated previously, wind speeds as low as 13 mph can result in entrainment of material for small diameter material (0.10 mm) [Chepil 1958].
REFERENCES Amponsah-Decosta F, Annegarn HJ [Jan.-March 1998]. Assessment of fugitive dust emissions from an opencast coal mine. J of the Mine Vent Soc of South Africa 51(1):5–
Armbrust DV, Dickerson JD [1971]. Temporary wind erosion control: cost effectiveness of 34 commercial materials. J of Soil and Water Cons 26(4):154–157. Bagnold RA [1960]. The physics of blown sand and desert dunes. London: Methuen & Co. LTD. Blue Skies Campaign, Arizona [2010]. Quick reference dust control guide. Arizona Department of Transportation, Air Quality Planning, Research, Final Project Reports, Dust Control Training Templates BlueSkies Summary Sheet. [http://www.azdot.gov/mpd/air_quality/pdf/Blueskies.pdf]. Date accessed: December 3, 2010.
Caterpillar, Inc. [2008]. 785 mining truck specifications. [http://www.cat.com/cda/layout?m=169215&x=7&f=227128]. Date accessed: October 12, 2008. Haul Roads, Stockpiles, and Open Areas 267
Chekan GJ, Cecala AB, Colinet JF [2003]. An evaluation of cab filtration and pressurization systems: two case studies. Proceedings of the Environment, Safety & Health Forum and Expo, Alexandria, VA: National Stone, Sand, and Gravel Association, pp. 114-129.
Chekan GJ, Colinet JF [2003]. Retrofit options for better dust control—cab filtration, pressurization systems prove effective in reducing silica dust exposures in older trucks. Aggregates Manager 8(9):9–12. Chepil WS [1956]. Influence of moisture on erodibility of soil by wind. Soil Sci Soc of Amer Proc 20(2):299–292. Chepil WS [1957]. Erosion of soil by wind. In: 1957 Yearbook of Agriculture, pp. 308– 314. U.S. Department of Agriculture. Chepil WS [1958]. Soil conditions that influence wind erosion. U.S. Department of Agriculture Technical Bulletin 1195.
Chepil WS, Woodruff NP [1955]. How to reduce dust storms. Agricultural Experiment Station Circular 318. Kansas State College of Agriculture and Applied Science,
Manhattan, Kansas. Chepil WS, Woodruff NP, Siddoway FH, Fryrear DW, Armbrust DV [1963]. Vegetative and nonvegetative materials to control wind and water erosion. Soil Sci Soc of Amer Proc 27(1):86–89.
Cole CF, Zapert JG [1995]. Air quality dispersion model validation at three stone quarries. Prepared for National Stone Association, Washington, D.C. Countess Environmental [2006]. WRAP fugitive dust handbook. WGA Contract #: 30204–111. Western Governors Association, Denver, Colorado.
Cowherd C, Grelinger MA [1996]. High-wind failure of soil moisture as a wind erosion control. Air and Waste Management Association, 89th Annual Meeting & Exhibition,
Cowherd C, Grelinger MA [1997]. Dust control for prevention of vehicle accidents. Proceedings of the 1997 Air & Waste Management Association's 90th Annual Meeting and Exhibition, Toronto, Ontario, Canada.
Cowherd C, Mulesky GE, Kinsey JS [1988]. Control of open fugitive dust sources. Environmental Protection Agency Contract No. 68–02–4395, Midwest Research Institute Project No. 8985–14, Research Triangle Park, North Carolina: U.S. EPA, Office of Air &
Diouf B, Skidmore EL, Layton JB, Hagen LJ [1990]. Stabilizing fine sand by adding clay: Laboratory wind tunnel study. Soil Tech 3:21–31. 268 Haul Roads, Stockpiles, and Open Areas
EPA [1998]. Section 13.2.2 Unpaved roads. In: Compilation of Air Pollution Emissions
Park, North Carolina: U.S. Environmental Protection Agency, Office of Air Quality Planning and Standards, Emission Factor and Inventory Group. Eslinger M [1997]. Controlling fugitive dust emissions with a foam suppression system. Cer Ind 147(7):S3–S5.
Fryrear DW, Skidmore EL [1985]. Chapter 24, methods for controlling wind erosion.
Madison, Wisconsin. pp. 443–457. Fuller J, Marsden L [2004]. Practical dust control agent and applications for alkaline ponds and playas. SME Annual Meeting, Denver, Colorado, 2004 SME Preprint #04–89.
Littleton, Colorado. Gillies JA, Watson JG, Rogers CF, DuBois D, Chow JC [1999]. Long-term effectiveness of dust suppressants to reduce PM10 emissions from unpaved roads. J of Air & Waste Man Assoc 49:3–16.
Grantz DA, Vaughn DL, Farber RJ, Kim B, Ashbaugh L, VanCuren T, and Campbell R. [1998]. Wind barriers suppress fugitive dust and soil-derived airborne particulates in arid regions. J of Environ Qual 27(4):946–952.
Hagen LJ, Armbrust DV [1992]. Aerodynamic roughness and saltation trapping efficiency of tillage ridge. Trans of the Am Soc of Agric Engrs 35(4):1179–1184.
Hagen LJ, Skidmore EL [1977]. Wind erosion and visibility problems. Trans of the Am Soc of Agric Engrs 20(5):898–903.
James DE, Piechota TC [2008]. Development of improved water spray patterns from construction water trucks. Presentation at Water Smart Innovations Conference and
Exposition, Las Vegas, Nevada. Kromrey RV, Scheffee RS, DePasquale JA, Valentine RS [1978]. Development of coatings for protection of coal during transport and storage. NTIS COO–4632–2. Prepared for U.S. Department of Energy, Division of Environmental Control Technology, Atlantic Research Corporation, Alexandria, Virginia.
Lyles L, Armbrust DV, Dickerson JD, Woodruff NP [1969]. Spray-on adhesives for temporary wind erosion control. J of Soil and Water Cons 24(5):190–193.
Lyles L, Schrandt RL, Schmeidler F [1974]. How aerodynamic roughness elements control sand movement. Trans of the Amer Soc of Agric Engrs 17(1):134–139.
Merritt FS, Loftin MK, Ricketts JT [1996]. Standard handbook for civil engineers, 4th ed. New York: McGraw-Hill. Haul Roads, Stockpiles, and Open Areas 269 Midwest Research Institute [1981]. Dust control for haul roads. U.S. Department of the