Policy Replication

Approval Tests and Standards for Closed-Circuit Escape Respirators

Federal Register2012-03-08 · DEPARTMENT OF HEALTH AND HUMAN SERVICES · Rule · 2012-4691
Final rule.

This final rule announces updated requirements that the National Institute for Occupational Safety and Health (NIOSH or Agency), located within the Centers for Disease Control and Prevention (CDC) in the Department of Health and Human Services (HHS or Department), will employ to test and approve closed-circuit respirators used for escaping atmospheres considered to be immediately dangerous to life and health, including such respirators required by the Mine Safety and Health Administration (MSHA) for use in underground coal mines. NIOSH and MSHA jointly review and approve this type of respirator used for mine emergencies under regulations concerning approval of respiratory protective devices. NIOSH also approves these respirators for use in other work environments where escape equipment may be provided to workers, such as on vessels operated by U.S. Navy and Coast Guard personnel. The purpose of these updated requirements is to enable NIOSH and MSHA to more effectively ensure the performance, reliability, and safety of CCERs.

RIN 0920-AA10

Other documents for the same rulemaking (all, by stage)

2008-12-10 Federal RegisterApproval Tests and Standards for Closed-Circuit Escape Respirators; Notice of Proposed Rulemaking
2009-03-04 Federal RegisterApproval Tests and Standards for Closed-Circuit Escape Respirators
2009-05-21 Federal RegisterApproval Tests and Standards for Closed-Circuit Escape Respirators
2010-10-08 Docket documentHIT Standards Committee Schedule for the Assessment of HIT Policy Committee Recommendation

References: 33 extracted, 20 linked to papers

Page 1Download these results: CSV · JSON
Report of Investigations (RI) 9333 Evaluation of the Safety of the CSE SR-100 Self-Contained Self-Rescuer, 1991.
Report of Investigations (RI) 8890, Evaluation of the Safety of One-Hour Compressed Oxygen Self-Rescuers—Results of Destructive Testing, 1984.
Pittsburgh Research Center (PRC) Report No. 4294, Evaluation of the Safety of One-Hour Chemical Self Rescuers, July 1980.
Kyriazi N, Shubilla JP. Self-contained self-rescuer field evaluation: seventh-phase results. Pittsburgh, PA: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health; March 2002. DHHS (NIOSH) Publication No. 2002-127, RI 9656.
(See below for a more thorough discussion of the change to a volume-based standard). In addition to what NIOSH considers a risk communication/management problem, NIOSH field evaluations of approved CCERs conducted systematically and in response to the concerns of users have identified damaged respirators that failed to meet the performance criteria under which they were approved.\2\ In some instances, the designs of these respirators did not allow the user or employer to evaluate the condition of a particular respirator prior to its use in either an evacuation drill or an actual emergency.
Glatte HA, Motsay GJ, Welch BE. Carbon dioxide tolerance studies. Brooks AFB, TX. U.S. Air Force, Aerospace Medicine Division, USAF School of Aerospace Medicine. Report #SAM-TR-67-77; 1967:1-22.
This could lead the user to abandon the CCER when its use is critical for survival. An excursion limit of 4 percent is physiologically tolerable for brief periods \8\ and its application to all CCER
Kamon E, Deno S, Vercruyyen M. Physiological responses of miners to emergency. Vol. 1—Self-contained breathing apparatus stressors. University Park, PA: The Pennsylvania State University. U.S. Bureau of Mines contract No. J0100092; 1984:13.
research reportNot linked to a paper · fn 8
Sheehy JB, Kamon E, Kiser D. Effects of carbon dioxide inhalation on psychomotor and mental performance during exercise and recovery. Human Factors. 1982;24(5), 581-588.
This could lead the user to abandon the CCER when its use is critical for survival. An excursion limit of 4 percent is physiologically tolerable for brief periods \8\ and its application to all CCER
Storm WF, and Giannetta CL. Effects of hypercapnia and bed rest on psychomotor performance. Aviation, Space, and Environmental Medicine. 1974;45:431-33.
journal articleNot linked to a paper · fn 8
Ainslie PN, Barach A, Cummings KJ, Murrell C, Hamlin M and Hellemans J. Cardiorespiratory and cerebrovascular responses to acute poikilocapnic hypoxia following intermittent and continuous exposure to hypoxia in humans. Journal of Applied Physiology. 2007;102:1953-1961.
As discussed above with respect to the carbon dioxide excursion limit, it allows only for brief variation to a low oxygen level, within physiologically established tolerance.\9\ To raise this excursion limit would require CCERs that would be ``overbuilt,'' resulting in unnecessarily large and/or heavy designs.
Fowler B, Paul M, Porlier G, Elcombe DD, Taylor M. A re-evaluation of the minimum altitude at which hypoxic performance decrements can be detected. Ergonomics. 1985;28(5): 781-791.
As discussed above with respect to the carbon dioxide excursion limit, it allows only for brief variation to a low oxygen level, within physiologically established tolerance.\9\ To raise this excursion limit would require CCERs that would be ``overbuilt,'' resulting in unnecessarily large and/or heavy designs.
Paul MA, Fraser WD. Performance during mild acute hypoxia. Aviation, Space, and Environmental Medicine. 1994;65(10):891-899.
As discussed above with respect to the carbon dioxide excursion limit, it allows only for brief variation to a low oxygen level, within physiologically established tolerance.\9\ To raise this excursion limit would require CCERs that would be ``overbuilt,'' resulting in unnecessarily large and/or heavy designs.
Hodgson JL. Physiological costs and consequences of mine escape and rescue. University Park, PA: The Pennsylvania State University. U.S. Bureau of Mines contract No. J0345327; 1993:19.
research reportNot linked to a paper · fn 11
Johnson, AT. A review of self-contained self-rescuer research. University of Maryland, Biological Resources Engineering, Human Performance Laboratory; 2005.
research reportNot linked to a paper · fn 19
Kamon E, Bernard T, Stein R. Steady state respiratory responses to tasks used in Federal testing of self-contained breathing apparatus. AIHAJ. 1975;36:886-896.
Louhevaara V, et al. Cardiorespiratory strain in jobs that require respiratory protection. Int. Arch. Occup. Environ. Health. 1985;55:195-206.
Lemon PW and Hermiston TT. The human energy cost of fire fighting. J. Occup. Med. 1977;19:558-562.
journal articleNot linked to a paper · fn 20
Kyriazi N. Proposal for certification tests and standards for closed-circuit breathing apparatus. Pittsburgh, PA: NIOSH; 1999. DHHS (NIOSH) Publication No. 99-144, IC 9449.
Given the impossibility of conducting representative simulations, NIOSH selected reasonable, scientifically-evaluated limits of likely human performance \25\ which are consistent with NIOSH's own laboratory experience.\26\ A well-established model developed by physiologists (the Bink-Bonjer curve) predicts that 95th percentile miners can maintain 3.0 liters/minute VO2 for 30 minutes and 2.0 liters/minute VO2 for 160 minutes.
Bink B. The physical working capacity in relation to working time and age. Ergonomics. January 1962;5:25-28.
According to physiological research \24\ as well as common experience, the higher the work rate, the less time one can sustain that work rate.
Vaught C, Brnich MJ, and Kellner HJ. Instructional mode and its effect on initial self-contained self-rescuer donning attempts during training. Pittsburgh, PA: U.S. Department of the Interior, Bureau of Mines; 1988. RI 9208.
research reportNot linked to a paper · fn 45
Turner N, Beeckman D, Hodous T. Evaluation of proposed methods to update human testing of self-contained breathing apparatus. AIHAJ. Dec. 1995;56:1195-1200.
The 0.5 liters per minute oxygen use-rate is very low, representing a sedentary person, such as a worker who might be trapped and awaiting rescue.\43\ ---------------------------------------------------------------------------
Zhuang Z and Bradtmiller B. Head-and-face anthropometric survey of U.S. respirator users. J. Occup. Environ Hyg. 2005;2:567-576.
Testing will be conducted using three human subjects of differing heights and weights,\44\ as specified, to provide reasonable assurance that the results would be representative of most potential CCER users. --------------------------------------------------------------------------- ---------------------------------------------------------------------------
Kyriazi N. Development of an automated breathing and metabolic simulator. Pittsburgh, PA: U.S. Department of the Interior, Bureau of Mines; 1986. IC 9110.
research reportNot linked to a paper · fn 30
Kyriazi N, Kovac JG, Shubilla JP, Duerr WH, Kravitz J. Self-contained self-rescuer field evaluation: first-year results of 5-year study. Pittsburgh, PA: U.S. Department of the Interior, Bureau of Mines; January 1986. RI 9051.
The use of these simulators to evaluate respirator performance has been validated by NIOSH through a series of MSHA peer-reviewed studies over the past 20 years.\31\ These studies, which include side-by-side comparisons using three-person panels of human subjects on treadmills against testing using an ABMS, demonstrate that the simulator replicates the performance of human subjects with respect to all important metabolic variables, including oxygen consumption rate, average rates of carbon dioxide production, ventilation rates, respiratory frequencies, respiratory temperatures (dry- and wet-bulb), and breathing pressures.
Kyriazi N, Shubilla JP. Self-contained self-rescuer field evaluation: results from 1982-1990. Pittsburgh, PA: U.S. Department of the Interior, Bureau of Mines; January 1992. RI 9401.
research reportNot linked to a paper · fn 31
Kyriazi N, Shubilla JP. Self-contained self-rescuer field evaluation: fourth-phase results. Pittsburgh, PA: U.S. Department of the Interior, Bureau of Mines; January 1994. RI 9499.
The use of these simulators to evaluate respirator performance has been validated by NIOSH through a series of MSHA peer-reviewed studies over the past 20 years.\31\ These studies, which include side-by-side comparisons using three-person panels of human subjects on treadmills against testing using an ABMS, demonstrate that the simulator replicates the performance of human subjects with respect to all important metabolic variables, including oxygen consumption rate, average rates of carbon dioxide production, ventilation rates, respiratory frequencies, respiratory temperatures (dry- and wet-bulb), and breathing pressures.
Kyriazi N, Shubilla JP. Self-contained self-rescuer field evaluation: fifth-phase results. Pittsburgh, PA: U.S. Department of Energy; December 1996. RI 9635.
The use of these simulators to evaluate respirator performance has been validated by NIOSH through a series of MSHA peer-reviewed studies over the past 20 years.\31\ These studies, which include side-by-side comparisons using three-person panels of human subjects on treadmills against testing using an ABMS, demonstrate that the simulator replicates the performance of human subjects with respect to all important metabolic variables, including oxygen consumption rate, average rates of carbon dioxide production, ventilation rates, respiratory frequencies, respiratory temperatures (dry- and wet-bulb), and breathing pressures.
Kyriazi N, Shubilla JP. Self-contained self-rescuer field evaluation: sixth-phase results. Pittsburgh, PA: NIOSH; July 2000. DHHS (NIOSH) Publication No. 2000-128, RI 9451.
NIOSH has investigated circumstances in which units were opened and modified by unauthorized persons, effectually altering the design from the version that received NIOSH testing and certification.\29\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------
Dayton T. Brown, Inc. Environmental test criteria for the acceptability of mine instrumentation. Phase 1, Final Report DTB2GR80-0643. U.S. Bureau of Mines contract No. J0100040; June 1980.
research reportNot linked to a paper · fn 46
McAteer JD, et al. The Sago Mine disaster: a preliminary report to Governor Joe Manchin III. Buckhannon, West Virginia; July 2006.
government reportNot linked to a paper · fn 49 · cited link
Kyriazi N, Shubilla JP. Self-contained self-rescuer field evaluation: seventh-phase results (Table 1 cost data source).
company, the products each make that are used in underground coal mining, the cost to NIOSH of purchasing an individual unit, and the market share of each type of respirator.\55\ ---------------------------------------------------------------------------
U.S. Government Accountability Office. Additional guidance and oversight of mines' emergency response plans would improve the safety of underground coal miners. April 2008; GAO-08-424 at 24.
government reportNot linked to a paper · fn 3 · cited link
European Standard BS EN 137:2006. Respiratory protective devices—Self-contained open-circuit compressed air breathing apparatus with full face mask—Requirements, testing, marketing. British Standards Institute.
otherNot linked to a paper · fn 16
U.S. Mine Safety and Health Administration. Report of Investigation: Fatal underground coal mine explosion; January 2, 2006; Sago Mine, Wolf Run Mining Co.; Tallmansville, Upshur County, WV. ID No. 46-08791.
government reportNot linked to a paper · fn 14