Policy Replication

Self-contained self-rescuer field evaluation: seventh-phase results.

2002 · report · doi:10.26616/nioshpub2002127 · 7 scholarly citations

A free copy is available at the open-access link. Its license does not let us host the file here.

Cited in 3 places in policy documents

Approval Tests and Standards for Closed-Circuit Escape Respirators

Federal Register2012-03-08 · DEPARTMENT OF HEALTH AND HUMAN SERVICES · fn 2
Kyriazi N, Shubilla JP. Self-contained self-rescuer field evaluation: seventh-phase results. Pittsburgh, PA: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health; March 2002. DHHS (NIOSH) Publication No. 2002-127, RI 9656.
(See below for a more thorough discussion of the change to a volume-based standard). In addition to what NIOSH considers a risk communication/management problem, NIOSH field evaluations of approved CCERs conducted systematically and in response to the concerns of users have identified damaged respirators that failed to meet the performance criteria under which they were approved.\2\ In some instances, the designs of these respirators did not allow the user or employer to evaluate the condition of a particular respirator prior to its use in either an evacuation drill or an actual emergency.

Approval Tests and Standards for Closed-Circuit Escape Respirators

Federal Register2012-03-08 · DEPARTMENT OF HEALTH AND HUMAN SERVICES · fn 55
Kyriazi N, Shubilla JP. Self-contained self-rescuer field evaluation: seventh-phase results (Table 1 cost data source).
company, the products each make that are used in underground coal mining, the cost to NIOSH of purchasing an individual unit, and the market share of each type of respirator.\55\ ---------------------------------------------------------------------------

Approval Tests and Standards for Closed-Circuit Escape Respirators; Notice of Proposed Rulemaking

Federal Register2008-12-10 · DEPARTMENT OF HEALTH AND HUMAN SERVICES · fn 2
Kyriazi N, Shubilla JP [2002]. Self-contained self-rescuer field evaluation: seventh-phase results. Pittsburgh, PA: U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, DHHS (NIOSH) Publication No. 2002-127, RI 9656.
NIOSH field evaluations of certified CCERs conducted systematically and in response to the concerns of users have identified damaged respirators that failed to meet the performance criteria under which they were certified.\2\ In some instances, the designs of these respirators did not allow the user or employer to evaluate the condition of a particular respirator prior to its use in either an evacuation drill or an actual emergency.