{"document":{"doc_id":13167,"source":"fr_rule","org":"DEPARTMENT OF HEALTH AND HUMAN SERVICES","doc_type":"Rule","title":"Approval Tests and Standards for Closed-Circuit Escape Respirators","date":"2012-03-08","url":"https://www.federalregister.gov/documents/2012/03/08/2012-4691/approval-tests-and-standards-for-closed-circuit-escape-respirators","source_native_id":"2012-4691","status":"fetched","abstract":"This final rule announces updated requirements that the National Institute for Occupational Safety and Health (NIOSH or Agency), located within the Centers for Disease Control and Prevention (CDC) in the Department of Health and Human Services (HHS or Department), will employ to test and approve closed-circuit respirators used for escaping atmospheres considered to be immediately dangerous to life and health, including such respirators required by the Mine Safety and Health Administration (MSHA) for use in underground coal mines. NIOSH and MSHA jointly review and approve this type of respirator used for mine emergencies under regulations concerning approval of respiratory protective devices. NIOSH also approves these respirators for use in other work environments where escape equipment may be provided to workers, such as on vessels operated by U.S. Navy and Coast Guard personnel. The purpose of these updated requirements is to enable NIOSH and MSHA to more effectively ensure the performance, reliability, and safety of CCERs.","action":"Final rule."},"dockets":[],"rins":["RIN 0920-AA10"],"related":[{"doc_id":16248,"source":"fr_rule","org":"DEPARTMENT OF HEALTH AND HUMAN SERVICES","doc_type":"Proposed Rule","title":"Approval Tests and Standards for Closed-Circuit Escape Respirators; Notice of Proposed Rulemaking","date":"2008-12-10"},{"doc_id":16049,"source":"fr_rule","org":"DEPARTMENT OF HEALTH AND HUMAN SERVICES","doc_type":"Proposed Rule","title":"Approval Tests and Standards for Closed-Circuit Escape Respirators","date":"2009-03-04"},{"doc_id":15913,"source":"fr_rule","org":"DEPARTMENT OF HEALTH AND HUMAN SERVICES","doc_type":"Proposed Rule","title":"Approval Tests and Standards for Closed-Circuit Escape Respirators","date":"2009-05-21"},{"doc_id":139083,"source":"docket_item","org":"HHS","doc_type":"other","title":"HIT Standards Committee Schedule for the Assessment of HIT Policy Committee Recommendation","date":"2010-10-08"}],"references":[{"citation_id":72009,"raw_reference":"Report of Investigations (RI) 9333 Evaluation of the Safety of the CSE SR-100 Self-Contained Self-Rescuer, 1991.","cited_authors":"U.S. Department of the Interior, Bureau of Mines","cited_year":"1991","cited_title":"Evaluation of the Safety of the CSE SR-100 Self-Contained Self-Rescuer","cited_venue":"U.S. Department of the Interior, Bureau of Mines","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"§ 84.308(b)","page":null,"context_sentence":null,"paper_id":74176,"paper_title":"Evaluation of the safety of the CSE SR-100 self-contained self-rescuer","paper_year":1991,"paper_doi":null},{"citation_id":72010,"raw_reference":"Report of Investigations (RI) 8890, Evaluation of the Safety of One-Hour Compressed Oxygen Self-Rescuers—Results of Destructive Testing, 1984.","cited_authors":"U.S. Department of the Interior, Bureau of Mines","cited_year":"1984","cited_title":"Evaluation of the Safety of One-Hour Compressed Oxygen Self-Rescuers—Results of Destructive Testing","cited_venue":"U.S. Department of the Interior, Bureau of Mines","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"§ 84.308(b)","page":null,"context_sentence":null,"paper_id":74175,"paper_title":"Evaluation of the safety of one-hour compressed oxygen self-rescuers--results of destructive testing","paper_year":1984,"paper_doi":null},{"citation_id":72011,"raw_reference":"Pittsburgh Research Center (PRC) Report No. 4294, Evaluation of the Safety of One-Hour Chemical Self Rescuers, July 1980.","cited_authors":"U.S. Department of the Interior, Bureau of Mines, Pittsburgh Research Center","cited_year":"1980","cited_title":"Evaluation of the Safety of One-Hour Chemical Self Rescuers","cited_venue":"U.S. Department of the Interior, Bureau of Mines, Pittsburgh Research Center","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"§ 84.308(b)","page":null,"context_sentence":null,"paper_id":74173,"paper_title":"Evaluation of the safety of one-hour chemical self rescuers","paper_year":1980,"paper_doi":null},{"citation_id":72797,"raw_reference":"Kyriazi N, Shubilla JP. Self-contained self-rescuer field evaluation: seventh-phase results. Pittsburgh, PA: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health; March 2002. DHHS (NIOSH) Publication No. 2002-127, RI 9656.","cited_authors":"Kyriazi N, Shubilla JP","cited_year":"2002","cited_title":"Self-contained self-rescuer field evaluation: seventh-phase results","cited_venue":"U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health; DHHS (NIOSH) Publication No. 2002-127, RI 9656","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"fn 2","page":null,"context_sentence":"(See below for a more thorough discussion of the change to a volume-based standard). In addition to what NIOSH considers a risk communication/management problem, NIOSH field evaluations of approved CCERs conducted systematically and in response to the concerns of users have identified damaged respirators that failed to meet the performance criteria under which they were approved.\\2\\ In some instances, the designs of these respirators did not allow the user or employer to evaluate the condition of a particular respirator prior to its use in either an evacuation drill or an actual emergency.","paper_id":23160,"paper_title":"Self-contained self-rescuer field evaluation: seventh-phase results.","paper_year":2002,"paper_doi":"10.26616/nioshpub2002127"},{"citation_id":72798,"raw_reference":"Glatte HA, Motsay GJ, Welch BE. Carbon dioxide tolerance studies. Brooks AFB, TX. U.S. Air Force, Aerospace Medicine Division, USAF School of Aerospace Medicine. Report #SAM-TR-67-77; 1967:1-22.","cited_authors":"Glatte HA, Motsay GJ, Welch BE","cited_year":"1967","cited_title":"Carbon dioxide tolerance studies","cited_venue":"U.S. Air Force, Aerospace Medicine Division, USAF School of Aerospace Medicine, Report #SAM-TR-67-77","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"fn 8","page":null,"context_sentence":"This could lead the user to abandon the CCER when its use is critical for survival. An excursion limit of 4 percent is physiologically tolerable for brief periods \\8\\ and its application to all CCER","paper_id":73846,"paper_title":"CARBON DIOXIDE TOLERANCE STUDIES","paper_year":1967,"paper_doi":null},{"citation_id":72799,"raw_reference":"Kamon E, Deno S, Vercruyyen M. Physiological responses of miners to emergency. Vol. 1—Self-contained breathing apparatus stressors. University Park, PA: The Pennsylvania State University. U.S. Bureau of Mines contract No. J0100092; 1984:13.","cited_authors":"Kamon E, Deno S, Vercruyyen M","cited_year":"1984","cited_title":"Physiological responses of miners to emergency. Vol. 1—Self-contained breathing apparatus stressors","cited_venue":"The Pennsylvania State University, U.S. Bureau of Mines contract No. J0100092","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"fn 8","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":72800,"raw_reference":"Sheehy JB, Kamon E, Kiser D. Effects of carbon dioxide inhalation on psychomotor and mental performance during exercise and recovery. Human Factors. 1982;24(5), 581-588.","cited_authors":"Sheehy JB, Kamon E, Kiser D","cited_year":"1982","cited_title":"Effects of carbon dioxide inhalation on psychomotor and mental performance during exercise and recovery","cited_venue":"Human Factors","cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"fn 8","page":null,"context_sentence":"This could lead the user to abandon the CCER when its use is critical for survival. An excursion limit of 4 percent is physiologically tolerable for brief periods \\8\\ and its application to all CCER","paper_id":73805,"paper_title":"Effects of Carbon Dioxide Inhalation on Psychomotor and Mental Performance during Exercise and Recovery","paper_year":1982,"paper_doi":"10.1177/001872088202400508"},{"citation_id":72801,"raw_reference":"Storm WF, and Giannetta CL. Effects of hypercapnia and bed rest on psychomotor performance. Aviation, Space, and Environmental Medicine. 1974;45:431-33.","cited_authors":"Storm WF, Giannetta CL","cited_year":"1974","cited_title":"Effects of hypercapnia and bed rest on psychomotor performance","cited_venue":"Aviation, Space, and Environmental Medicine","cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"fn 8","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":72802,"raw_reference":"Ainslie PN, Barach A, Cummings KJ, Murrell C, Hamlin M and Hellemans J. Cardiorespiratory and cerebrovascular responses to acute poikilocapnic hypoxia following intermittent and continuous exposure to hypoxia in humans. Journal of Applied Physiology. 2007;102:1953-1961.","cited_authors":"Ainslie PN, Barach A, Cummings KJ, Murrell C, Hamlin M, Hellemans J","cited_year":"2007","cited_title":"Cardiorespiratory and cerebrovascular responses to acute poikilocapnic hypoxia following intermittent and continuous exposure to hypoxia in humans","cited_venue":"Journal of Applied Physiology","cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"fn 9","page":null,"context_sentence":"As discussed above with respect to the carbon dioxide excursion limit, it allows only for brief variation to a low oxygen level, within physiologically established tolerance.\\9\\ To raise this excursion limit would require CCERs that would be ``overbuilt,'' resulting in unnecessarily large and/or heavy designs.","paper_id":73959,"paper_title":"Cardiorespiratory and cerebrovascular responses to acute poikilocapnic hypoxia following intermittent and continuous exposure to hypoxia in humans","paper_year":2007,"paper_doi":"10.1152/japplphysiol.01338.2006"},{"citation_id":72803,"raw_reference":"Fowler B, Paul M, Porlier G, Elcombe DD, Taylor M. A re-evaluation of the minimum altitude at which hypoxic performance decrements can be detected. Ergonomics. 1985;28(5): 781-791.","cited_authors":"Fowler B, Paul M, Porlier G, Elcombe DD, Taylor M","cited_year":"1985","cited_title":"A re-evaluation of the minimum altitude at which hypoxic performance decrements can be detected","cited_venue":"Ergonomics","cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"fn 9","page":null,"context_sentence":"As discussed above with respect to the carbon dioxide excursion limit, it allows only for brief variation to a low oxygen level, within physiologically established tolerance.\\9\\ To raise this excursion limit would require CCERs that would be ``overbuilt,'' resulting in unnecessarily large and/or heavy designs.","paper_id":73984,"paper_title":"A re-evaluation of the minimum altitude at which hypoxic performance decrements can be detected","paper_year":1985,"paper_doi":"10.1080/00140138508963198"},{"citation_id":72804,"raw_reference":"Paul MA, Fraser WD. Performance during mild acute hypoxia. Aviation, Space, and Environmental Medicine. 1994;65(10):891-899.","cited_authors":"Paul MA, Fraser WD","cited_year":"1994","cited_title":"Performance during mild acute hypoxia","cited_venue":"Aviation, Space, and Environmental Medicine","cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"fn 9","page":null,"context_sentence":"As discussed above with respect to the carbon dioxide excursion limit, it allows only for brief variation to a low oxygen level, within physiologically established tolerance.\\9\\ To raise this excursion limit would require CCERs that would be ``overbuilt,'' resulting in unnecessarily large and/or heavy designs.","paper_id":74111,"paper_title":"Performance during mild acute hypoxia.","paper_year":1994,"paper_doi":null},{"citation_id":72805,"raw_reference":"Hodgson JL. Physiological costs and consequences of mine escape and rescue. University Park, PA: The Pennsylvania State University. U.S. Bureau of Mines contract No. J0345327; 1993:19.","cited_authors":"Hodgson JL","cited_year":"1993","cited_title":"Physiological costs and consequences of mine escape and rescue","cited_venue":"The Pennsylvania State University, U.S. Bureau of Mines contract No. J0345327","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"fn 11","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":72806,"raw_reference":"Johnson, AT. A review of self-contained self-rescuer research. University of Maryland, Biological Resources Engineering, Human Performance Laboratory; 2005.","cited_authors":"Johnson AT","cited_year":"2005","cited_title":"A review of self-contained self-rescuer research","cited_venue":"University of Maryland, Biological Resources Engineering, Human Performance Laboratory","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"fn 19","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":72807,"raw_reference":"Kamon E, Bernard T, Stein R. Steady state respiratory responses to tasks used in Federal testing of self-contained breathing apparatus. AIHAJ. 1975;36:886-896.","cited_authors":"Kamon E, Bernard T, Stein R","cited_year":"1975","cited_title":"Steady state respiratory responses to tasks used in Federal testing of self-contained breathing apparatus","cited_venue":"AIHAJ","cited_doi":"10.1080/0002889758507361","cited_url":null,"ref_kind":"journal_article","section":"fn 15","page":null,"context_sentence":null,"paper_id":16893,"paper_title":"Steady state respiratory responses to tasks used in Federal testing of self-contained breathing apparatus","paper_year":1975,"paper_doi":"10.1080/0002889758507361"},{"citation_id":72848,"raw_reference":"Louhevaara V, et al. Cardiorespiratory strain in jobs that require respiratory protection. Int. Arch. Occup. Environ. Health. 1985;55:195-206.","cited_authors":"Louhevaara V, et al.","cited_year":"1985","cited_title":"Cardiorespiratory strain in jobs that require respiratory protection","cited_venue":"Int. Arch. Occup. Environ. Health","cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"fn 20","page":null,"context_sentence":null,"paper_id":73983,"paper_title":"Cardiorespiratory strain in jobs that require respiratory protection","paper_year":1985,"paper_doi":"10.1007/bf00383753"},{"citation_id":72849,"raw_reference":"Lemon PW and Hermiston TT. The human energy cost of fire fighting. J. Occup. Med. 1977;19:558-562.","cited_authors":"Lemon PW, Hermiston TT","cited_year":"1977","cited_title":"The human energy cost of fire fighting","cited_venue":"J. Occup. Med.","cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"fn 20","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":72850,"raw_reference":"Kyriazi N. Proposal for certification tests and standards for closed-circuit breathing apparatus. Pittsburgh, PA: NIOSH; 1999. DHHS (NIOSH) Publication No. 99-144, IC 9449.","cited_authors":"Kyriazi N","cited_year":"1999","cited_title":"Proposal for certification tests and standards for closed-circuit breathing apparatus","cited_venue":"NIOSH, DHHS (NIOSH) Publication No. 99-144, IC 9449","cited_doi":"10.26616/nioshpub99144","cited_url":null,"ref_kind":"research_report","section":"fn 26","page":null,"context_sentence":"Given the impossibility of conducting representative simulations, NIOSH selected reasonable, scientifically-evaluated limits of likely human performance \\25\\ which are consistent with NIOSH's own laboratory experience.\\26\\ A well-established model developed by physiologists (the Bink-Bonjer curve) predicts that 95th percentile miners can maintain 3.0 liters/minute VO2 for 30 minutes and 2.0 liters/minute VO2 for 160 minutes.","paper_id":16894,"paper_title":"Proposal for certification tests and standards for closed-circuit breathing apparatus.","paper_year":1999,"paper_doi":"10.26616/nioshpub99144"},{"citation_id":72851,"raw_reference":"Bink B. The physical working capacity in relation to working time and age. Ergonomics. January 1962;5:25-28.","cited_authors":"Bink B","cited_year":"1962","cited_title":"The physical working capacity in relation to working time and age","cited_venue":"Ergonomics","cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"fn 24","page":null,"context_sentence":"According to physiological research \\24\\ as well as common experience, the higher the work rate, the less time one can sustain that work rate.","paper_id":16895,"paper_title":"THE PHYSICAL WORKING CAPACITY IN RELATION TO WORKING TIME AND AGE","paper_year":1962,"paper_doi":"10.1080/00140136208930548"},{"citation_id":72852,"raw_reference":"Vaught C, Brnich MJ, and Kellner HJ. Instructional mode and its effect on initial self-contained self-rescuer donning attempts during training. Pittsburgh, PA: U.S. Department of the Interior, Bureau of Mines; 1988. RI 9208.","cited_authors":"Vaught C, Brnich MJ, Kellner HJ","cited_year":"1988","cited_title":"Instructional mode and its effect on initial self-contained self-rescuer donning attempts during training","cited_venue":"U.S. Bureau of Mines, RI 9208","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"fn 45","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":72853,"raw_reference":"Turner N, Beeckman D, Hodous T. Evaluation of proposed methods to update human testing of self-contained breathing apparatus. AIHAJ. Dec. 1995;56:1195-1200.","cited_authors":"Turner N, Beeckman D, Hodous T","cited_year":"1995","cited_title":"Evaluation of proposed methods to update human testing of self-contained breathing apparatus","cited_venue":"AIHAJ","cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"fn 43","page":null,"context_sentence":"The 0.5 liters per minute oxygen use-rate is very low, representing a sedentary person, such as a worker who might be trapped and awaiting rescue.\\43\\ ---------------------------------------------------------------------------","paper_id":16896,"paper_title":"Evaluation of Proposed Methods to Update Human Testing of Self-Contained Breathing Apparatus","paper_year":1995,"paper_doi":"10.1080/15428119591016214"},{"citation_id":72854,"raw_reference":"Zhuang Z and Bradtmiller B. Head-and-face anthropometric survey of U.S. respirator users. J. Occup. Environ Hyg. 2005;2:567-576.","cited_authors":"Zhuang Z, Bradtmiller B","cited_year":"2005","cited_title":"Head-and-face anthropometric survey of U.S. respirator users","cited_venue":"J. Occup. Environ Hyg.","cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"fn 44","page":null,"context_sentence":"Testing will be conducted using three human subjects of differing heights and weights,\\44\\ as specified, to provide reasonable assurance that the results would be representative of most potential CCER users. --------------------------------------------------------------------------- ---------------------------------------------------------------------------","paper_id":23162,"paper_title":"Head-and-Face Anthropometric Survey of U.S. Respirator Users","paper_year":2005,"paper_doi":"10.1080/15459620500324727"},{"citation_id":72855,"raw_reference":"Kyriazi N. Development of an automated breathing and metabolic simulator. Pittsburgh, PA: U.S. Department of the Interior, Bureau of Mines; 1986. IC 9110.","cited_authors":"Kyriazi N","cited_year":"1986","cited_title":"Development of an automated breathing and metabolic simulator","cited_venue":"U.S. Bureau of Mines, IC 9110","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"fn 30","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":72856,"raw_reference":"Kyriazi N, Kovac JG, Shubilla JP, Duerr WH, Kravitz J. Self-contained self-rescuer field evaluation: first-year results of 5-year study. Pittsburgh, PA: U.S. Department of the Interior, Bureau of Mines; January 1986. RI 9051.","cited_authors":"Kyriazi N, Kovac JG, Shubilla JP, Duerr WH, Kravitz J","cited_year":"1986","cited_title":"Self-contained self-rescuer field evaluation: first-year results of 5-year study","cited_venue":"U.S. Bureau of Mines, RI 9051","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"fn 31","page":null,"context_sentence":"The use of these simulators to evaluate respirator performance has been validated by NIOSH through a series of MSHA peer-reviewed studies over the past 20 years.\\31\\ These studies, which include side-by-side comparisons using three-person panels of human subjects on treadmills against testing using an ABMS, demonstrate that the simulator replicates the performance of human subjects with respect to all important metabolic variables, including oxygen consumption rate, average rates of carbon dioxide production, ventilation rates, respiratory frequencies, respiratory temperatures (dry- and wet-bulb), and breathing pressures.","paper_id":74172,"paper_title":"Self-contained self-rescuer field evaluation : first-year results of 5-year study","paper_year":1986,"paper_doi":null},{"citation_id":72857,"raw_reference":"Kyriazi N, Shubilla JP. Self-contained self-rescuer field evaluation: results from 1982-1990. Pittsburgh, PA: U.S. Department of the Interior, Bureau of Mines; January 1992. RI 9401.","cited_authors":"Kyriazi N, Shubilla JP","cited_year":"1992","cited_title":"Self-contained self-rescuer field evaluation: results from 1982-1990","cited_venue":"U.S. Bureau of Mines, RI 9401","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"fn 31","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":72858,"raw_reference":"Kyriazi N, Shubilla JP. Self-contained self-rescuer field evaluation: fourth-phase results. Pittsburgh, PA: U.S. Department of the Interior, Bureau of Mines; January 1994. RI 9499.","cited_authors":"Kyriazi N, Shubilla JP","cited_year":"1994","cited_title":"Self-contained self-rescuer field evaluation: fourth-phase results","cited_venue":"U.S. Bureau of Mines, RI 9499","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"fn 31","page":null,"context_sentence":"The use of these simulators to evaluate respirator performance has been validated by NIOSH through a series of MSHA peer-reviewed studies over the past 20 years.\\31\\ These studies, which include side-by-side comparisons using three-person panels of human subjects on treadmills against testing using an ABMS, demonstrate that the simulator replicates the performance of human subjects with respect to all important metabolic variables, including oxygen consumption rate, average rates of carbon dioxide production, ventilation rates, respiratory frequencies, respiratory temperatures (dry- and wet-bulb), and breathing pressures.","paper_id":74254,"paper_title":"Self-Contained Self-Rescuer Field Evaluation: Sixth-Phase Results","paper_year":2000,"paper_doi":"10.66828/001c.167926"},{"citation_id":72859,"raw_reference":"Kyriazi N, Shubilla JP. Self-contained self-rescuer field evaluation: fifth-phase results. Pittsburgh, PA: U.S. Department of Energy; December 1996. RI 9635.","cited_authors":"Kyriazi N, Shubilla JP","cited_year":"1996","cited_title":"Self-contained self-rescuer field evaluation: fifth-phase results","cited_venue":"U.S. Department of Energy, RI 9635","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"fn 31","page":null,"context_sentence":"The use of these simulators to evaluate respirator performance has been validated by NIOSH through a series of MSHA peer-reviewed studies over the past 20 years.\\31\\ These studies, which include side-by-side comparisons using three-person panels of human subjects on treadmills against testing using an ABMS, demonstrate that the simulator replicates the performance of human subjects with respect to all important metabolic variables, including oxygen consumption rate, average rates of carbon dioxide production, ventilation rates, respiratory frequencies, respiratory temperatures (dry- and wet-bulb), and breathing pressures.","paper_id":74254,"paper_title":"Self-Contained Self-Rescuer Field Evaluation: Sixth-Phase Results","paper_year":2000,"paper_doi":"10.66828/001c.167926"},{"citation_id":72860,"raw_reference":"Kyriazi N, Shubilla JP. Self-contained self-rescuer field evaluation: sixth-phase results. Pittsburgh, PA: NIOSH; July 2000. DHHS (NIOSH) Publication No. 2000-128, RI 9451.","cited_authors":"Kyriazi N, Shubilla JP","cited_year":"2000","cited_title":"Self-contained self-rescuer field evaluation: sixth-phase results","cited_venue":"NIOSH, DHHS (NIOSH) Publication No. 2000-128, RI 9451","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"fn 29","page":null,"context_sentence":"NIOSH has investigated circumstances in which units were opened and modified by unauthorized persons, effectually altering the design from the version that received NIOSH testing and certification.\\29\\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------","paper_id":74242,"paper_title":"Self-contained self-rescuer field evaluation: sixth-phase results.","paper_year":2000,"paper_doi":"10.26616/nioshpub2000128"},{"citation_id":72861,"raw_reference":"Dayton T. Brown, Inc. Environmental test criteria for the acceptability of mine instrumentation. Phase 1, Final Report DTB2GR80-0643. U.S. Bureau of Mines contract No. J0100040; June 1980.","cited_authors":"Dayton T. Brown, Inc.","cited_year":"1980","cited_title":"Environmental test criteria for the acceptability of mine instrumentation","cited_venue":"U.S. Bureau of Mines contract No. J0100040","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"fn 46","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":72862,"raw_reference":"McAteer JD, et al. The Sago Mine disaster: a preliminary report to Governor Joe Manchin III. Buckhannon, West Virginia; July 2006.","cited_authors":"McAteer JD, et al.","cited_year":"2006","cited_title":"The Sago Mine disaster: a preliminary report to Governor Joe Manchin III","cited_venue":"Buckhannon, West Virginia","cited_doi":null,"cited_url":"http://www.wvgov.org/SagoMineDisasterJuly2006FINAL.pdf","ref_kind":"government_report","section":"fn 49","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":72863,"raw_reference":"Kyriazi N, Shubilla JP. Self-contained self-rescuer field evaluation: seventh-phase results (Table 1 cost data source).","cited_authors":"Kyriazi N, Shubilla JP","cited_year":"2002","cited_title":"Self-contained self-rescuer field evaluation: seventh-phase results","cited_venue":"U.S. Department of Health and Human Services, CDC, NIOSH; DHHS (NIOSH) Publication No. 2002-127, RI 9656","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"fn 55","page":null,"context_sentence":"company, the products each make that are used in underground coal mining, the cost to NIOSH of purchasing an individual unit, and the market share of each type of respirator.\\55\\ ---------------------------------------------------------------------------","paper_id":23160,"paper_title":"Self-contained self-rescuer field evaluation: seventh-phase results.","paper_year":2002,"paper_doi":"10.26616/nioshpub2002127"},{"citation_id":72864,"raw_reference":"U.S. Government Accountability Office. Additional guidance and oversight of mines' emergency response plans would improve the safety of underground coal miners. April 2008; GAO-08-424 at 24.","cited_authors":"U.S. Government Accountability Office","cited_year":"2008","cited_title":"Additional guidance and oversight of mines' emergency response plans would improve the safety of underground coal miners","cited_venue":"GAO","cited_doi":null,"cited_url":"http://www.gao.gov/new.items/d08424.pdf","ref_kind":"government_report","section":"fn 3","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":72865,"raw_reference":"European Standard BS EN 137:2006. Respiratory protective devices—Self-contained open-circuit compressed air breathing apparatus with full face mask—Requirements, testing, marketing. British Standards Institute.","cited_authors":"British Standards Institute","cited_year":"2006","cited_title":"Respiratory protective devices—Self-contained open-circuit compressed air breathing apparatus with full face mask—Requirements, testing, marketing","cited_venue":"British Standards Institute","cited_doi":null,"cited_url":null,"ref_kind":"other","section":"fn 16","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":72866,"raw_reference":"U.S. Mine Safety and Health Administration. Report of Investigation: Fatal underground coal mine explosion; January 2, 2006; Sago Mine, Wolf Run Mining Co.; Tallmansville, Upshur County, WV. ID No. 46-08791.","cited_authors":"U.S. Mine Safety and Health Administration","cited_year":"2006","cited_title":"Report of Investigation: Fatal underground coal mine explosion; January 2, 2006; Sago Mine, Wolf Run Mining Co.","cited_venue":"MSHA","cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"fn 14","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null}]}