BACKGROUND In April 2012, the EPA released a technical report for peer review that discussed flare operation and performance observations made by evaluating the available flare testing reports. In response to EPA Office of Enforcement requests pursuant to section 114 of the Clean Air Act, flare testing was conducted using the Passive Fourier Transform Infrared (PFTIR) technique on steam-assisted flares located at Marathon Petroleum Company, Texas City, Texas (MPC TX), Marathon Petroleum Company, Detroit, Michigan (MPC Detroit), Flint Hills Resources, Port
Arthur, Texas (FHR), Shell, Deer Park, Texas (Shell), and INEOS ABS (USA), Addyston, Ohio (INEOS). Each facility provided the EPA the PFTIR raw data, composition of the flare vent gas, flow rate of the flare vent gas and steam, and the overall results from each of the flare tests. In addition to these tests, the PFTIR technique was also used in a comprehensive flare study conducted by Texas Commission on Environmental Quality (TCEQ) and the University of Texas at Austin. The results from the TCEQ study are available on TCEQ’s Stakeholder Group: Flare Task Force website1; and TCEQ provided the EPA the PFTIR raw data. The April 2012 technical report was a result of the analysis of these flare efficiency studies and flare performance test reports. To provide an objective evaluation of the analysis, the
EPA asked a third party (an organization not involved with the development of the April 2012 technical report) to facilitate an ad hoc peer review process of the technical report. This third party established a balanced peer review panel of reviewers from outside the EPA. The panel of reviewers consisted of individuals that could be considered “technical combustion experts” within four interest groups: the refinery industry, industrial flare consultants, academia, and environmental stakeholders.
Allen, D. T., and V. M. Torres. 2011. 2010 Flare study final report. Prepared for the Texas Commission on Environmental Quality, Tracking No. 2008-81. <http://www.tceq.texas.gov/assets/public/implementation/air/rules/Flare/2010flarestudy/2010flare-study-final-report.pdf>. September 20. Clean Air Engineering, Inc. 2010a. Performance test of a steam-assisted elevated flare with passive FTIR. Prepared by Marathon Petroleum Company, LLC, Findlay, OH and Clean Air
Engineering, Inc., Palatine, IL. Clean Air Engineering, Inc. 2010b. Performance test of a steam-assisted elevated flare with passive FTIR - Detroit. Prepared by Marathon Petroleum Company, LLC Findlay, OH and Clean Air Engineering, Inc., Palatine, IL. Clean Air Engineering, Inc. 2011. PFTIR test of steam-assisted elevated flares – Port Arthur. The statistic results for Ccz are based on values that have been converted to be on a propane basis so that a total hydrocarbon analyzer with a flame ionization detector could more easily be used as a monitoring device. This adjustment was made by dividing the carbon count of the various hydrocarbons by 3 (for propane) and then adding hydrogen. This adjustment was not done in the April 2012 technical report; therefore the threshold values shown in this memorandum differ from those Ccz threshold values discussed in April 2012 technical report. Prepared for Flint Hills Resources Port Arthur, LLC.
Davis, A, C. Law, and H. Wang. 1999. Propene pyrolysis and oxidation kinetics in a flow reactor and laminar flames. Combustion and Flame. 119, 375-399.
INEOS ABS (USA) Corporation. 2010. Passive Fourier transform infrared technology (FTIR) evaluation of P001 process control device at the INEOS ABS (USA) Corporation. Addyston,
Laskin, A., H. Wang, and C.K. Law. 2000. Detailed kinetic modeling of 1,3-butadiene oxidation at high temperatures. International Journal of Chemical Kinetics. 32:10, 589-614.
McDaniel, M. 1983. Flare efficiency study. Prepared for U.S. EPA Office of Research and Development EPA-600/2-83-052 by Engineering Science, Inc. (July).
Pohl, J., R. Payne, and J. Lee. 1984. Evaluation of the efficiency of industrial flares: Test Results. EPA-600/2-84-095. Prepared for U.S. EPA Office of Research and Development by Energy and Environmental Research Corporation (May).
Pohl, J. and N. Soelberg. 1985. Evaluation of the efficiency of industrial flares: Flare head design and gas composition. EPA-600/2-85-106. Prepared for U.S. EPA Office of Air Quality Planning and Standards. (September).
Pohl, J. and N. Soelberg. 1986. Evaluation of the efficiency of industrial flares: H2S gas mixtures and pilot assisted flares. EPA-600/2-86-080. Prepared for U.S. EPA Office of Air Quality Planning and Standards. (September).
SAS Institute Inc. 2013. SAS/ETS(R) 9.2 User's Guide. Retrieved May 28, 2013, from SAS Product Documentation: http://support.sas.com/documentation/cdl/en/etsug/60372/HTML/default/viewer.htm#etsug_mod el_sect051.htm Shell Global Solutions (US) Inc. 2011a. Shell Deer Park Refining LP Deer Park Refinery East Property Flare Test Report. Prepared by Shell Global Solutions (US) Inc., Houston, TX (April). U.S. EPA. 2012. Parameters for Properly Designed and Operated Flares. Located at: http://www.epa.gov/ttn/atw/flare/2012flaretechreport.pdf U.S. EPA. 2006. Office of Environmental Information. Data Quality Assessment: Statistical Methods for Practitioners, EPA QA/G-9S. Washington, DC: EPA Office of Environmental Information.