Critical Review of Differential Absorption Lidar (DIAL) Emission Test Data for BP Petroleum Refinery in Texas City, Texas [EPA 453/R-10-002]
Other documents for the same rulemaking (all, by stage)
References: 21 extracted, 0 linked to papers
1. NPL (National Physical Laboratory). 2008. Measurement of VOC emissions from petrochemical industry sites in the Houston area using Differential Absorption Lidar (DIAL) during summer 2007. Draft. February.
2. TCEQ (Texas Commission on Environmental Quality). 2009. EIQ Report. BP Products North
America, Inc. RN102535077. April 30. 3. LaRocca, P. 2009a. Email from P. LaRocca, BP Products North America, Inc., to B. Shine
4. Hildebrand, S. 2009. TCEQ Differential Absorption Lidar (DIAL) Project—Summer 2007. Presented at NPRA Environmental Conference. Denver, Colorado. September. 5. U. S. EPA (Environmental Protection Agency). AP-42. Compilation of Air Pollutant Emission Factors. Volume I. Fifth Edition. Section 7.1 Organic Liquid Storage Tanks. Available at: www.epa.gov/ttn/chief/ap42/index.html.
6. API (American Petroleum Institute). 1994. Manual of Petroleum Measurement Standards: Chapter 19: Evaporative Loss Measurement, Section 2, Evaporative Loss From Floating Roof
Tanks, Preliminary Draft. December. 7. Duke, J. 2008. Email from J. Duke, BP, to B. Shine, EPA/OAQPS. Tank data and gas flow and composition data for the temporary flare and ULC flare. December 17.
8. TCEQ (Texas Commission on Environmental Quality). 2010. Differential Absorption LIDAR Study. Final Report. March 29.
9. Duke, J. 2009a. Letter and Attachments from J. Duke, BP Products North America, to B. Shine, U.S. EPA/OAQPS. Confidential information in response to email sent 6-3-09. June 17.
10. LaRocca, P. 2009b. Email from P. LaRocca, BP Products North America, Inc., to B. Shine,
11. Coburn, J., C. Allen, D. Green, and K.Leese. 1988. Site visits of aerated and nonaerated impoundments. Summary report. Research Triangle Park, NC. Prepared for the Hazardous Waste Engineering Research Laboratory, U.S. Environmental Protection Agency, Cincinnati, OH.
12. LaRocca, P. 2010. Email from P. LaRocca, BP Products North America, to B. Shine,
13. Hermanson, R. 2009. Letter from R. Hermanson, BP America Inc., to EPA Docket Center (2822T). BP America Comments on Standards of Performance for Petroleum Refineries for Which Construction, Reconstruction, or Modification Commenced After May 14, 2007. February 5. Docket item no. EPA-HQ-OAR-2007-0011-0304. 14. U.S. EPA (Environmental Protection Agency). 1983. Flare Efficiency Study. EPA-600/2-83-052. Prepared by Engineering-Science, Inc. July. Critical Review of DIAL Emission Test Data for BP Petroleum Refinery in Texas City, Texas
15. Duke, J. 2009b. Email from J. Duke, BP Texas City Refinery, to B. Shine, USEPA/OAQPS. Responses to DIAL data questions. June 3.
16. LaRocca, P. 2010. Letter from P. LaRocca, BP Texas City Refinery, to B. Shine, U.S.
EPA/OAQPS. BP comments on EPA’s report of the 2007 DIAL study. July 20.
17. Alberta Research Council. 2006. Refinery Demonstration of Optical Technologies for Measurement of Fugitive Emissions and for Leak Detection. March.
18. URS Corporation. 2008. Source Test Report of the Coker Steam Vent for Non-Methane and NonEthane Volatile Organic Compounds. Prepared for CITGO Refining and Chemicals Company
LP, Corpus Christi, TX. April 25. 19. SCAQMD (South Coast Air Quality Management District). 2004a. Source Test Report 03-194 Conducted at Chevron/Texaco Refinery, El Segundo, California—Volatile Organic Compound (VOC), Carbon Monoxide (CO), and Particulate Matter (PM) Emissions from a Coke Drum Stream Vent. May 14.
20. SCAQMD (South Coast Air Quality Management District). 2004c. Source Test Report 03-198 Conducted at ExxonMobil Refinery, Torrance, California—Volatile Organic Compound (VOC), Carbon Monoxide (CO), and Particulate Matter (PM) Emissions from a Coke Drum Stream Vent. March 4.
21. SCAQMD (South Coast Air Quality Management District). 2004d. Source Test Report 03-200 Conducted at Shell Oil Refinery, Wilmington, California—Volatile Organic Compound (VOC), Carbon Monoxide (CO), and Particulate Matter (PM) Emissions from a Coke Drum Stream Vent. July 1.
22. URS Corporation. 2008. Source Test Report of the Coker Steam Vent. Prepared for Hovensa,