Texas Commission on Environmental Quality (TCEQ) 2010 Flare Study: Final Report
Other documents for the same rulemaking (all, by stage)
References: 11 extracted, 0 linked to papers
TCEQ 2010 Flare Study The University of Texas at Austin The Center for Energy & Environmental Resources August 1, 2011 Appendix D – Summary of Steam-Assisted Flare Test Data Appendix E – Summary of Air-Assisted Flare Test Data Appendix F – Emissions Measured During Propylene Flare Tests for
TCEQ 2010 Flare Study The University of Texas at Austin The Center for Energy & Environmental Resources August 1, 2011 List of Figures Figure
Baukal, Jr., Charles E. (2001). The John Zink Combustion Handbook, CRC Press, New York.
Environ International Corporation, (2009). Control of HRVOC Emissions in Flares at Low Flow
Conditions, Project 2009-53 (DRAFT Interim Report). Flare Details for General Refinery and Petrochemical Service, American Petroleum Institute
ANSI/API Standard 537, Washington, DC, 2008.
Green, Don W. and R. Perry, (2008). Perry’s Chemical Engineer’s Handbook, 8th Edition,
McGraw-Hill, New York, 2008. Hashmonay, Ram A.,Ravi M. Varma, Mark Modrak, and Robert H. Kagman, Simultaneous Measurement of Vaporous and Aerosolized Threats by Active Open Path FTIR. http://www.dtic.mil/cgi-bin/GetTRDoc?AD=ADA449529&Location=U2&doc=GetTRDoc.pdf (accessed May 18, 2010). Marathon Petroleum Company, LP, Detroit Refinery. Performance Test of a Steam-Assisted Elevated Flare with Passive FTIR – Detroit, Final Report. Detroit, Michigan, November 2010. Marathon Petroleum Company, LLC, Texas Refining Division. Performance Test of a SteamAssisted Elevated Flare with Passive FTIR, Final Report. Texas City, Texas, May, 2010.
McDaniel, Marc, Flare Efficiency Study, United States Environmental Protection Agency, Report No. 600/2-83-052, July 1983. National Physical Laboratory, Measurement of VOC Emissions from Petrochemical Industry Sites in the Houston Area Using Differential Absorption Lidar (DIAL) During Summer 2007, Draft for Comment. Texas Commission on Environmental Quality, February 2008. Texas Commission on Environmental Quality, (2009). Proposal for Grant Activities No. 582-886245-FY09-04, Comprehensive Flare Study, Tracking Number 2008-01, Amendments 1 & 3 (2010). The University of Texas at Austin, (2010). Quality Assurance Project Plan for Texas Commission on Environmental Quality Comprehensive Flare Study Project, PGA No. 582-8862-45-FY09-04, Tracking No. 2008-81, Rev. 1. The University of Texas at Austin, August 2010. United States Government. Code of Federal Regulations - Standards of Performance for New Stationary Sources, General Control Device and Work Practice Requirements, 40CFR § 60.18. http://edocket.access.gpo.gov/cfr_2009/julqtr/pdf/40cfr60.18.
TCEQ 2010 Flare Study The University of Texas at Austin The Center for Energy & Environmental Resources August 1, 2011
URS Corporation. Passive FTIR Phase I Testing of Simulated and Controlled Flare Systems: Final Report. Texas Commission on Environmental Quality, June 2004.