Performance of a new personal respirable dust monitor for mine use.
Publisher page (DOI)OpenAlex record
Cited in 6 places in policy documents
Lowering Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors
Volkwein, J.C., R.P. Vinson, L.J. McWilliams, D.P. Tuchman, and S.E. Mischler. June 2004. Performance of a New Personal Respirable Dust Monitor For Mine Use. CDC Report of Investigation 9663.
This testing demonstrated that the CPDM is suitable for use in coal mines to monitor and prevent overexposure to respirable coal mine dust (Volkwein et al., 2004, NIOSH RI 9663; Volkwein et al., 2006, NIOSH RI 9669). --------------------------------------------------------------------------- ---------------------------------------------------------------------------
Lowering Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors
Volkwein et al., 2004, NIOSH RI 9663
This testing demonstrated that the CPDM is suitable for use in coal mines to monitor and prevent overexposure to respirable coal mine dust (Volkwein et al., 2004, NIOSH RI 9663; Volkwein et al., 2006, NIOSH RI 9669). --------------------------------------------------------------------------- ---------------------------------------------------------------------------
Preliminary Regulatory Economic Analysis (PREA) for Proposed Rule Lowering Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors (2010)
Volkwein, J.C., Vinson R.P., McWilliams L.J., Tuchman D.P., and Mischler S.E. Performance of a New Personal Respirable Dust Monitor for Mine Use. CDC. NIOSH. RI 9663. June 2004.
Preliminary Regulatory Economic Analysis (PREA) for Proposed Rule Lowering Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors (2010)
Volkwein, J.C., Vinson R.P., McWilliams L.J., Tuchman D.P., and Mischler S.E. (2004). Performance of a New Personal Respirable Dust Monitor for Mine Use. RI9663. Centers for Disease Control (CDC). National Institute for Occupational Safety and Health (NIOSH). June. pp 25.
Coal Mine Dust Sampling Devices
Volkwein, J.C., R.P. Vinson, L.J. McWilliams, D.P. Tuchman, and S.E. Mischler, Performance of a New Personal Respirable Dust Monitor for Mine Use. CDC RI 9663. June 2004.
This information can be used to give early warnings of deteriorating dust controls to mine operators, allowing corrective action to be taken before the dust control system fails resulting in full-shift exposures exceeding regulatory limits.\2\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------
Coal Mine Dust Personal Monitors
Volkwein, J.C., R.P. Vinson, L.J. McWilliams, D.P. Tuchman, and S.E. Mischler, Performance of a New Personal Respirable Dust Monitor for Mine Use. CDC RI 9663. June 2004.
These projections can serve as a warning system to mine operators, assisting them in recognizing exposure levels that, if not reduced, would result in full-shift exposures exceeding regulatory limits.\2\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------