Coal Mine Dust Sampling Devices
This final rule revises requirements that the Mine Safety and Health Administration (MSHA) and the National Institute for Occupational Safety and Health (NIOSH) use to approve sampling devices that monitor miner exposure to respirable coal mine dust. The final rule updates approval requirements for the existing "coal mine dust personal sampler unit" to reflect improvements in this sampler over the past 15 years. The final rule also establishes criteria for approval of a new type of technology, the "continuous personal dust monitor," which is worn by the miner and will report dust exposure levels continuously during the shift.
Original sourceXML (168 KB)PDF (211 KB)
Other documents for the same rulemaking
References: 9 extracted, 6 linked to papers
Volkwein, J.C., Vinson, R.P., S.J. Page, L.J. McWilliams, G.J. Joy, S.E. Mischler, and D.P. Tuchman. Laboratory and field performance of a continuously measuring personal respirable dust monitor. CDC RI 9669. September 2006. 47 pp.
This information can be used to give early warnings of deteriorating dust controls to mine operators, allowing corrective action to be taken before the dust control system fails resulting in full-shift exposures exceeding regulatory limits.\2\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------
Volkwein, J.C., R.P. Vinson, L.J. McWilliams, D.P. Tuchman, and S.E. Mischler, Performance of a New Personal Respirable Dust Monitor for Mine Use. CDC RI 9663. June 2004.
This information can be used to give early warnings of deteriorating dust controls to mine operators, allowing corrective action to be taken before the dust control system fails resulting in full-shift exposures exceeding regulatory limits.\2\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------
Kennedy, E. R., T.J. Fischbach, R. Song, P.M. Eller, and S.A. Shulman, 1995. Guidelines for air sampling and analytical method development and evaluation, DHHS (NIOSH) Publication No. 95-117.
These methods have been summarized and issued as general guidelines by NIOSH in ``Components for the Evaluation of Direct-Reading Monitors for Gases and Vapors''.\6\ The requirements also reflect the state-of-the-art technology of the CPDM prototype.
Guffy, S.E., M.E. Flanagan, G. VanBelle. Air Sampling at the chest and ear as representative of the breathing zone. AIHAJ, 62:416-427, 2001
Current industrial hygiene principles accept breathing zone samples as most representative of the atmosphere to which workers are exposed.\8\ MSHA did not receive any comments on the proposal. --------------------------------------------------------------------------- ---------------------------------------------------------------------------
Vinson, R.P. and J. C. Volkwein, Determining the Spatial Variability of Personal Sampler Inlet Locations (in press) JOEH, 2007.
Current industrial hygiene principles accept breathing zone samples as most representative of the atmosphere to which workers are exposed.\8\ MSHA did not receive any comments on the proposal. --------------------------------------------------------------------------- ---------------------------------------------------------------------------
NIOSH Manual of Analytic Methods, Method 0600, Issue 3, Fourth Edition, January 15, 1998.
Components for the Evaluation of Direct-Reading Monitors for Gases and Vapors
Continuous Personal Dust Monitor Accuracy Testing, June 23, 2008
ISO Q9001:2000 Quality management systems—Requirements, 3rd edition, approved on December 15, 2000