Policy Replication

Lowering Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors

Federal Register2014-05-01 · DEPARTMENT OF LABOR; Mine Safety and Health Administration · Rule · 2014-09084
Final rule.

The Mine Safety and Health Administration (MSHA) is revising the Agency's existing standards on miners' occupational exposure to respirable coal mine dust in order to: Lower the existing exposure limits; provide for full-shift sampling; redefine the term "normal production shift"; and add reexamination and decertification requirements for persons certified to sample for dust, and maintain and calibrate sampling devices. In addition, the rule provides for single shift compliance sampling by MSHA inspectors, establishes sampling requirements for mine operators' use of the Continuous Personal Dust Monitor (CPDM), requires operator corrective action on a single, full- shift operator sample, changes the averaging method to determine compliance on operator samples, and expands requirements for medical surveillance of coal miners. Chronic exposure to respirable coal mine dust causes lung diseases that can lead to permanent disability and death. The final rule will greatly improve health protections for coal miners by reducing their occupational exposure to respirable coal mine dust and by lowering the risk that they will suffer material impairment of health or functional capacity over their working lives.

RIN 1219-AB64 · Docket MSHA-2010-0007

Other documents for the same rulemaking

2010-10-19 Federal RegisterLowering Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors
2010-10-19 Regulatory impact analysisRIA cited in FR 2010-25249: Lowering Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors
2010-11-15 Federal RegisterLowering Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors
2010-11-30 Federal RegisterLowering Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors
2011-01-14 Federal RegisterLowering Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors
2011-03-08 Federal RegisterLowering Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors
2011-04-18 Regulatory impact analysisPreliminary Regulatory Economic Analysis (PREA) for Proposed Rule Lowering Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors (2010)
2011-05-04 Federal RegisterLowering Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors
2011-05-27 Federal RegisterLowering Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors
2014-04-23 Regulatory impact analysisU.S. Environmental Protection Agency, Office of Air and Radiation. 2011. Regulatory Impact Analysis for the Federal Implementation Plans to Reduce Interstate Transport of Fine Particulate Matter and Ozone in 27 States; Correction of SIP Approvals for 22 States. Docket ID No. EPA-HQ-OAR-2009-0491. June 2011, http://www.epa.gov/airtransport/pdfs/FinalRIA.pdf.
2014-04-23 Regulatory impact analysisU.S. Department of Labor, Mine Safety and Health Administration (2014). Regulatory Economic Analysis (REA) for Lowering Miners’ Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors. March 2014.
2014-04-23 Regulatory impact analysisU.S. Department of Labor, Occupational Safety and Health Administration. 2006. Final Economic and Regulatory Flexibility Analysis for OSHA’s Final Standard for Occupational Exposure to Hexavalent Chromium (Docket H054A, Exhibit 49), Chapter VI: Benefits and Net Benefits. February 23, 2006.
2014-05-01 Regulatory impact analysisRIA cited in FR 2014-09084: Lowering Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors
2014-07-07 Federal RegisterLowering Miners' Exposure to Coal Mine Dust Including Continuous Personal Dust Monitors

References: 110 extracted, 46 linked to papers

Page 1Download these results: CSV · JSON
Ahmad, D., W.K.C. Morgan, N.L. Lapp, R. Reger, J.J. Renn III. 2002. Correspondence: Letter To the Editor, Meretricious Effects of Coal Dust, re: Beeckman, et al. (2001), Am J Respir Crit Care Med., 165(4):552-553.
journal articleNot linked to a paper · IX. References
Antao, V.C., E.L. Petsonk, L.Z. Sokolow, A.L. Wolfe, G.A. Pinheiro, J.M. Hale, and M.D. Attfield. 2005. Rapidly Progressive Coal Workers' Pneumoconiosis in the United States: Geographic Clustering and Other Factors. Occup Environ Med., 62(10):670-674.
who have been diagnosed with CWP 1/0+ that need to be studied to determine the reasons for the rapid progression (see Antao et al. 2005, 2006; Attfield and Petsonk, 2007). The Wade et al.
Attfield, M.D., and N.S. Seixas. 1995. Prevalence of Pneumoconiosis and Its Relationship to Dust Exposure in a Cohort of U.S. Bituminous Coal Miners and Ex-Miners. Am J Ind Med., 27:137-151.
The QRAs primarily relied on three epidemiologic studies: Attfield and Seixas (1995); Kuempel et al.
Attfield, M.D., and E.D. Kuempel. 2008. Mortality among U.S. Underground Coal Miners, A 23-Year Follow-Up. Am J Ind Med, 51(4):231-245.
(2009a); and Attfield and Kuempel (2008).
Attfield, M.D., K.M. Bang, E.L. Petsonk, P.L. Schleiff, and J.M. Mazurek. 2009. Trends in Pneumoconiosis Mortality and Morbidity for the United States, 1968-2005, and Relationship With Indicators of Extent of Exposure. Journal of Physics: Conference Series 151, 012051.
In response, MSHA notes the data show that there was a reduction in prevalence of CWP in the 1990s until continued surveillance indicated that many cases of CWP were missed or newly developed (Attfield et al., 2009).
Beeckman, L.A., M.L. Wang, E.L. Petsonk, and G.R. Wagner. 2001. Rapid Declines in FEV1 and Subsequent Respiratory Symptoms, Illnesses, and Mortality in Coal Miners in the United States. Am J Respir Crit Care Med, 163(3):633-639.
Colinet, J.F., J.P. Rider, J.M. Listak, J.A. Organiscak, and A.L. Wolfe. 2010. Best Practices for Dust Control in Coal Mining. DHHS (NIOSH) Publication No. 2010-110, Information Circular 9517.
(Colinet et al., 2010 NIOSH Information Circular 9517, Best Practices for Dust Control in Coal Mining, (``NIOSH IC 9517''), pp.
Cowie, H.A., B.G. Miller, and C.A. Soutar. 2006. Dust Related Risks Of Clinically Relevant Lung Functional Deficits. Occup Environ Med, 63(5):320-325.
Cohen, R.A., A. Patel, and F.H. Green. 2008. Lung Disease Caused By Exposure to Coal Mine and Silica Dust. Seminars in Respiratory and Critical Care Medicine, 29(6):651-661.
Cohen et al. (2008) reported that disease progression continues after exposures stop, increasing lung function impairment and pneumoconiosis levels in miners once they leave employment (i.e., ex-miners and retired miners).
Kogut, J., T.F. Tomb, P.S. Parobeck, A.J. Gero, and K.L. Suppers. 1997. Measurement Precision With The Coal Mine Dust Personal Sampler. App Occ Environ Hyg, 12:999-1006.
The data from these field experiments were used by NIOSH in its direct approach to determining whether MSHA's method meets the long-established NIOSH Accuracy Criterion (Kogut et al., 1997). The criterion requires that, with high confidence, measurements must consistently fall within a specified percentage of the true concentration being measured.
Kuempel, E.D., M. Wheeler, R.J. Smith, V. Vallyathan, and F.H.Y Green. 2009b. Contributions of Dust Exposure and Cigarette Smoking to Emphysema Severity in Coal Miners in the United States. Am J Respir Crit Care Med, 180(3): 257-264.
(See Section IV, Health Effects, in the preamble to the proposed rule (75 FR 64458), Green et al., 1998a, and Kuempel et al., 2009b.)
Laney, A., and M. Attfield. 2010. Coal Workers' Pneumoconiosis and Progressive Massive Fibrosis Are Increasingly More Prevalent Among Workers in Small Underground Coal Mines in the United States. Occup and Env Med, 67:428-431.
(2009) and Laney and Attfield (2010).
Magat, W., W. Viscusi, and J. Huber. 1996. A Reference Lottery Metric For Valuing Health. Management Science, 42(8): 1118-1130.
For these reasons MSHA concluded that the symptoms expressed in Magat et al. (1996) are more comparable to the disabling consequences and long-term health effects of PMF and severe emphysema. However, both studies are methodologically imperfect.
Page, S., J. Volkwein, R. Vinson, G. Joy, S. Mischler, D. Tuchman, and L. McWilliams. 2008. Equivalency of a Personal Dust Monitor To The Current United States Coal Mine Respirable Dust Sampler. Journal of Environmental Monitoring, 10(1):96-101.
health- based dust risks, benefits, and limits were based. As noted in the preamble to the proposed rule, NIOSH researchers (Page et al., 2008) determined that measurements of respirable dust concentrations using the CPDM and CMDPSU are comparable.
Peters, R.H., C. Vaught, E. Hall, and J. Volkwein. 2008. Miners' Views About Personal Dust Monitors. Information Circular 9501, NIOSH.
For example, a NIOSH study, Information Circular (IC) 9501- Miners' Views about Personal Dust Monitors (Peters et al., 2008), provided limited insight into ergonomic issues associated with wearing a CPDM.
Pollock, D., J. Potts, and G. Joy. 2010. Investigation into Dust Exposures And Mining Practices in the Southern Appalachian region. Mining Engineering, 62:44-9.
It was also noted that thin seam mining poses difficulties because the rock surrounding the coal seam often has to be cut to permit equipment to be employed effectively (also see Pollock et al., 2010).
Rider, J.P. and J.F. Colinet. 2011. Benchmarking Longwall Dust Technology And Practices. Min Eng, 63(9):74-80.
(Rider et al., 2011, pp.
Soutar, C.A., J.F. Hurley, B.G. Miller, H.A. Cowie, and D. Buchanan. 2004. Dust Concentrations and Respiratory Risks In Coalminers: Key Risk Estimates From the British Pneumoconiosis Field Research. Occup Environ Med, 61(6):477-481.
Suarthana, E., A.S. Laney, E. Storey, J.M. Hale, M.D. Attfield. 2011. Coal Workers' Pneumoconiosis In The United States: Regional Differences 40 Years after Implementation of the 1969 Federal Coal Mine Health and Safety Act. Occup Environ Med, doi: 10.1136/oem.2010.063594.
They presented various analyses of the NIOSH studies and submitted for the rulemaking record a NIOSH study that was published after the proposed rule (Suarthana et al., 2011).
State of West Virginia. 2011. Report to the Governor, Governor's Independent Investigation Panel, Upper Big Branch. The April 5, 2010, Explosion: A Failure Of Basic Coal Mine Safety Practices. May 2011.
government reportNot linked to a paper · IX. References
Taylor, D.G., R.E. Kupel, and J.M. Bryant. 1977. Documentation of the NIOSH Validation Tests. DHEW (NIOSH) Publication No. 77-185, April 1977.
research reportNot linked to a paper · IX. References
Kennedy, E.R., T.J. Fischbach, R. Song, P.M. Eller, and S.A. Shulman. 1995. Guidelines for Air Sampling and Analytical Method Development and Evaluation. DHHS (NIOSH) Publication No. 95-117, May 1995.
In its comments on the proposed rule, NIOSH stated that it questioned the commenters' interpretation of the data for three reasons. The analytical methodology used by the commenters was inappropriate for the conditions to which it was applied; several of the commenters inappropriately referred to their data by using a scientific term that could be interpreted in different ways; and none of the commenters' data included statistically representative samples that fully reflect the conditions observed nationwide in underground coal mines. Regarding the comments that the CPDM did not meet the NIOSH Accuracy Criterion (Kennedy et al., 1995), NIOSH commented that this criterion is designed primarily this criterion is designed primarily for evaluating the accuracy of a sampling and analytical method under controlled laboratory conditions.
Sunstein, C. 2004. Valuing Life: A Plea For Disaggregation. Duke Law Journal, 54: 385-445.
journal articleValuing life: a plea for disaggregation. (2004) · IX. References
U.S. DOE, EIA, Annual Coal Report 2010, Table 28.
datasetNot linked to a paper · fn 63 · cited link
DHHS (NIOSH) Publication No. 2008-143a, Work-Related Lung Disease Surveillance Report 2007, Vol. 1, Table 2-4. Coal workers' pneumoconiosis: Number of deaths by state, U.S. residents age 15 and over, 1995-2004, p. 34, September 2008.
research reportNot linked to a paper · fn 1 · cited link
U.S. Department of Labor, Division of Coal Mine Workers' Compensation. 2012. Black Lung Program Statistics.
datasetNot linked to a paper · I. Executive Summary, A. Purpose of the Regulatory Action
Volkwein et al., U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health (USDHHS, CDC, NIOSH) 2006), "Laboratory and Field Performance of a Continuously Measuring Personal Respirable Dust Monitor," NIOSH Report of Investigations 9669
This testing demonstrated that the CPDM is suitable for use in coal mines to monitor and prevent overexposure to respirable coal mine dust (Volkwein et al., 2004, NIOSH RI 9663; Volkwein et al., 2006, NIOSH RI 9669). --------------------------------------------------------------------------- ---------------------------------------------------------------------------
Mine Safety: Reports and Key Studies Support the Scientific Conclusions Underlying the Proposed Exposure Limit for Respirable Coal Mine Dust
government reportNot linked to a paper · II.G. Government Accountability Office Activities
Basis for Proposed Exposure Limit on Respirable Coal Mine Dust and Possible Approaches for Lowering Dust Levels
government reportNot linked to a paper · II.G. Government Accountability Office Activities
Current Intelligence Bulletin 64, Coal Mine Dust Exposure and Associated Health Outcomes, A Review of Information Published Since 1995 (NIOSH CIB 64) (USDHHS, CDC, NIOSH (2011a))
The comment period closed on December 14, 2009. On September 6, 2011, NIOSH approved a commercial CPDM as meeting the CPDM requirements of 30 CFR part 74 (USDHHS, CDC, NIOSH, 2011).
Suarthana et al., 2011
journal articleNot linked to a paper · III.A. Health Effects
Wade et al. (2010) retrospective chart review of 138 coal miners with PMF
journal articleNot linked to a paper · III.A. Health Effects
Antao et al. (2005) identified a total of 886 cases of CWP among 29,521 miners examined from 1996 to 2002 in the CWXSP
who have been diagnosed with CWP 1/0+ that need to be studied to determine the reasons for the rapid progression (see Antao et al. 2005, 2006; Attfield and Petsonk, 2007). The Wade et al.
Laney and Attfield (2010) examined NIOSH CWXSP data collected between 1970 and 2009 and evaluated the effect of mine size on the development of CWP and PMF
journal articleNot linked to a paper · III.A. Health Effects
Laney et al., 2009
journal articleNot linked to a paper · III.A. Health Effects
Attfield and Petsonk, 2007
journal articleNot linked to a paper · III.A. Health Effects
Huang et al., 2005
journal articleNot linked to a paper · III.A. Health Effects
Miller et al. (2007) mortality of a cohort of 17,820 British coal miners followed 1970 through 2006
journal articleNot linked to a paper · III.A. Health Effects
Cohen et al. (2008) reported that disease progression continues after exposures stop
journal articleNot linked to a paper · III.A. Health Effects
Kuempel et al. (2009a) emphysema severity exposure-response model
journal articleNot linked to a paper · III.B. Quantitative Risk Assessment (QRA)
Kuempel et al. (2009b) autopsy study of 722 miners and non-miners
journal articleNot linked to a paper · III.B. Quantitative Risk Assessment (QRA)
Attfield and Kuempel (2008) proportional hazards analysis of NMRD mortality by coal rank region
journal articleNot linked to a paper · III.B. Quantitative Risk Assessment (QRA)
Attfield and Seixas (1995)
journal articleNot linked to a paper · III.B. Quantitative Risk Assessment (QRA)
Treaftis, H.N. and T.F. Tomb. 1974. Effect of Orientation On Cyclone Penetration Characteristics. Am Ind Hyg Assoc J, 35(10):598-602.
In fiscal year 2011, only 26 of the 54,809 inspector and 42 of the 46,846 operator samples processed were found to contain an excessive number of oversize particles and thus were voided. While rough handling of the CMDPSU or an accidental mishap could conceivably cause a sample with a weight gain less than 6 mg to become contaminated, short-term accidental inclinations of the cyclone will not affect respirable mass measurements made with CMDPSU (Treaftis and Tomb, 1974).
Vallyathan, V., F. Green, P. Brower, and M. Attfield. 1997. The Role of Coal Mine Dust Exposure in the Development of Pulmonary Emphysema. Ann Occup Hyg 41(Suppl 1): 352-357.
Viscusi, W. and J. Aldy. 2003. The Value Of A Statistical Life: A Critical Review Of Market Estimates Throughout The World. Journal of Risk and Uncertainty, 27(1):5-76.
At a 7 percent discount rate, the total net benefit is -$114.7 million and the annualized net benefit is -$8.1 million. For the proposed rule, MSHA monetized the reduction in the number of deaths from NMRD using a study by Viscusi and Aldy (2003).
Viscusi, W.K., W.A. Magat, and J. Huber. 1991. Pricing Environmental Health Risks: Survey Assessments of Risk—Risk and Risk—Dollar Trade-Offs for Chronic Bronchitis. Journal of Environmental Economics and Management. 21: 32-51.
The health implications of chronic bronchitis identified by Viscusi et al. (1991) also did not include premature death, a well-known outcome of PMF and severe emphysema.
Volkwein, J.C. 2008. Analysis of Particulate Contamination In Personal Dust Monitor Sampling. Proceedings of the 12th U.S./North American Mine Ventilation Symposium, Reno, Nevada, June 9-11, 2008.
Volkwein, J.C., R.P. Vinson, L.J. McWilliams, D.P. Tuchman, and S.E. Mischler. June 2004. Performance of a New Personal Respirable Dust Monitor For Mine Use. CDC Report of Investigation 9663.
This testing demonstrated that the CPDM is suitable for use in coal mines to monitor and prevent overexposure to respirable coal mine dust (Volkwein et al., 2004, NIOSH RI 9663; Volkwein et al., 2006, NIOSH RI 9669). --------------------------------------------------------------------------- ---------------------------------------------------------------------------
Volkwein, J.C., V.P. Vinson, S.J. Page, L.J. McWilliams, G.J. Joy, S.E. Mischler, and D.P. Tuchman. September 2006. Laboratory and Field Performance Of A Continuously Measuring Personal Respirable Dust Monitor. DHHS (NIOSH) Publication No. 2006-145, CDC Report of Investigations 9669.
This testing demonstrated that the CPDM is suitable for use in coal mines to monitor and prevent overexposure to respirable coal mine dust (Volkwein et al., 2004, NIOSH RI 9663; Volkwein et al., 2006, NIOSH RI 9669). --------------------------------------------------------------------------- ---------------------------------------------------------------------------