Ex. #136: Occupational Safety and Health Administration. (2009). Controlling silica exposures in construction (OSHA 3362-05 2009).
Other documents for the same rulemaking (all, by stage)
References: 208 extracted, 0 linked to papers
OSHA recommends that employers rely on manufacturers’ information and use proper methods to minimize employees’ dust exposures, rather than testing joint compounds themselves. Regardless of a compound’s silica content, the high levels of dust that drywall finishing may generate also poses a health hazard. Thus, OSHA recommends that employees always use dust control measures when drywall sanding. The two principal methods for controlling dust are (1) vacuum dust collection systems and (2) wet sponging. Either method is easy to implement. Silica-Free Joint Compounds • Check the label and the MSDS to identify the product’s ingredients (usually listed in Section 3 on the MSDS). • Avoid using joint compounds that contain crystalline silica or quartz (another common term for crystalline silica). • Always use dust control methods, regardless of the joint compound’s silica content. Vacuum Dust Collection Systems Vacuum dust collection (VDC) systems for drywall sanding equipment are commercially available, and studies show that they significantly reduce total dust concentrations. A NIOSH study of the effectiveness of several vacuum dust collection systems showed reductions in total dust exposures ranging from 80 to 97 percent, depending on the system used (NIOSH, 1995).
ACGIH. 2001. Threshold limit values for chemical substances and physical agents and biological exposure indices. American Conference of Governmental Industrial Hygienists, Cincinnati, OH. Center to Protect Workers’ Rights (CPWR). 1998. Drywall Dust Engineering Controls. Video VI-98. Produced jointly with National Institute for Occupational Safety and Health (NIOSH) Engineering and Work Practices Controls Work Group.
Epling, C., Gitelman, A., Desai, T. and J. Dement. 1999. Airborne exposures and ambulatory peak expiratory flow in drywall finishers. Report OSH298. Center to Protect Workers’ Rights.
Lofgren, D.J. 1993. Case studies: Silica exposure for concrete workers and masons. Appl. Occup. Environ. Hyg. 8(10):832-836. October, 1993.
Murray J. and Nadel J., Editors. Textbook of Respiratory Medicine, 2nd Ed., 1994, Airway
Pharmacology, pp. 285-311. NIOSH. 1984. Health Hazard Evaluation Report. Grand Gulf Nuclear Power Plant, Port Gibson, MI. Dept. of Health and Human Services (HETA 83-1321508). Cincinnati, OH.
NIOSH. 1995. In-depth survey report: a laboratory comparison of conventional drywall sanding techniques versus commercially available control. ECTB 208-11a. National Institute for Occupational Safety and Health.
NIOSH. 1997. Health Hazard Evaluation Report. Center to Protect Workers’ Rights. Washington, DC, Dept. of Health and Human Services Report (HETA94-0078-2660). Cincinnati, OH.
NIOSH 2001. In-depth survey report for four sites: exposure to silica from hand tools in construction chipping, grinding, and hand demolition at Frank Messer and Sons Construction Company, Lexington and Newport, KY, and Columbus and Springfield, OH (EPHB 247-15). National Institute for Occupational Safety and Health, Cincinnati, OH. April, 2001. Occupational Safety and Health Administration Occupational Safety and Health (NIOSH) recommends that respirable crystalline silica exposures be limited to 0.05 mg/m3 as a 10-hour time-weighted average (NIOSH, 2002). The American Conference of Governmental Industrial Hygienists (ACGIH) recommends that respirable crystalline silica exposures be limited to 0.025 mg/m3 as an 8-hour time-weighted average (ACGIH, 2008).
June, 2002. OSHA Case Files (Special Emphasis Program Inspection Reports from 1996-1998).
USG. 2002. Finishing and Decorating Gypsum Panels/Wet Sanding. J-610/12-87. http://www.usg.com. (Accessed November 16, 2002.) A 382-minute sample resulted in a respirable dust exposure level of 7.0 mg/m3 and a silica level concentration of 0.21 mg/m3.
Epling (1999) collected 8-hour respirable crystalline silica samples at two construction sites using a 10millimeter cyclone at 2.6 liters/minute (LPM) airflow to achieve a 4-micrometer cut-point. Crystalline silica was quantifiable at 1.1 to 3.7 percent in four of the six samples.
NIOSH (1997) used Dorr-Oliver cyclones at 1.7 LPM to collect 22 samples, of which 15 (68 percent) contained silica amounts between the level of quantification (LOQ) and limit of detection (LOD). In the same report, NIOSH described two additional respirable crystalline silica results from another site as 0.04 and 0.08 mg/m3 for samples of 443 and 435 minutes duration.
Young-Corbett, D.E. and Nussbaum, M.A. (2009). Dust Control Effectiveness of Drywall Sanding Tools. Journal of Occupational and Environmental
OSHA’s construction PEL for crystalline silica, established in 1971, is still listed as a particle-count value. (See Appendix E to OSHA’s National Emphasis Program for Crystalline Silica, CPL 03-00-007, for a detailed discussion of the conversion factor used to transform gravimetric measurements to particlecount values). In this guidance, OSHA is using 0.1 mg/m3 of respirable quartz as an 8-hour timeweighted average as a benchmark to describe the effectiveness of control measures. The benchmark is approximately equivalent to the general industry silica PEL. Other organizations suggest more stringent levels. For example, the National Institute for
CONTROLLING SILICA These values were those reported in the CPWR video, which may not have shown all measurements taken during the study. Respirable dust levels were not reported (CPWR, 1998). When the silica percentage is in doubt, some laboratories that specialize in environmental testing can analyze a sample of the product to determine the actual silica content. OSHA recommends, however, that employers minimize employee exposure by relying on manufacturers’ information and using dust control methods rather than by testing joint compounds themselves. Data values were averaged from those presented in the CPWR video, which may not include all values measured during the actual study.
ACGIH. 2001. Industrial Ventilation, a Manual of Recommended Practice, 25th edition. American Conference of Governmental Industrial Hygienists,
Addo, J.Q. and Sanders, T.J. 1995. Effectiveness and environmental impact of road dust suppressants. Mountain-Plains Consortium Report No. 95-28A.
Beardwood, J. 2001. Dust gets in your eyes…lungs, wallet, and other wear parts. Grading and Excavation Contractor. www.forester.net/gx_0106_ dust.html. Bureau of Mines. 1985. Adding steam to control dust in mineral processing. Report of Investigation No. 8935, 1985.
Drenner, J., and T. Trumbull. 2003. Preliminary report on used fryer oil as a dust suppressant. P² Highlight. (January) www.iwrc/org/p2highlt/p2current.cfm.
Echt, A., and W.K. Sieber. 2002. Case Studies: Control of silica exposure from hand tools in construction: Grinding concrete. Appl. Occup. Environ. Hygiene. 17(7):457-461. July, 2002.
Flanagan, M.E., N. Seixas, M. Majar, J. Camp, and M. Morgan. 2003. Silica dust exposures during selected construction activities. Am. Ind. Hygiene Assn. J 64(3):319-28. May-June, 2003.
Grenier, M.G. and Bigu, J. 1988. Suppression of airborne dust in hard rock mines by means of electrostatic water sprays. Appl. Ind. Hygiene. 3:251-257.
September, 1988. Heckel, C.L., A. Quraishi, N.G. Carlson, and A.J.
Streifel. 2000. Evaluation of vacuum cleaners: A method to evaluate the cleaning effectiveness and airborne particle generation of vacuum cleaners. Poster presented at 2000 American Industrial Hygiene Conference and Exposition.
Hogan, T.J. 1996. Selected particulates: silica. In
Plog, B.A., J. Niland, and P.J. Quinlan, eds. Fundamentals of Industrial Hygiene, 4th ed. National Safety Council. Itasca, IL, pp. 180-182, 1996.
Johnston, A.M., J.H. Vincent, and A.D. Jones. 1985. Measurement of electric charge for workplace aerosols. Ann. Occup. Hygiene. 29:2, 1985.
McKernan, J. 2000. Personal communication between J. McKernan of National Institute for Occupational Safety and Health and L. Lewis of Eastern Research Group, January 28, 2000.
NIOSH. 1998. Evaluation of substitute materials for silica sand in abrasive blasting. Report prepared under contract 200-95-2946. National Institute for Occupational Safety and Health. Pittsburgh, PA.
September, 1998. NIOSH. 1999a. Control technology and exposure assessment for occupational exposure to crystalline silica: case 04 -- a concrete finishing operation. Report # ECTB 233-104c. National Institute for Occupational Safety and Health, Cincinnati, OH.
April, 1999. NIOSH. 1999b. Control technology and exposure assessment for occupational exposure to crystalline silica: case 15 – concrete cutting. Report # ECTB 233-115c. National Institute for Occupational Safety and Health, Cincinnati, OH. November, 1999.
NIOSH. 2000. In-depth survey report: Control technology for environmental enclosures – an evaluation of in-use enclosures at San Joaquin Helicopter. National Institute for Occupational Safety and
Health, Cincinnati, OH, 1999. NIOSH. 2001a. Technology news: Sweeping compound application reduces dust from soiled floors within enclosed operator cabs (No. 487). National Institute for Occupational Safety and Health,
Pittsburgh, PA. March, 2001. NIOSH. 2001b. In-depth survey report of exposure to silica from hand tools in construction chipping, Occupational Safety and Health Administration grinding, and hand demolition at Frank Messer and Sons Construction Company: Lexington and
Newport, KY, Columbus and Springfield, OH. Report # 247-15. National Institute for Occupational Safety and Health, Cincinnati, OH, April, 2001.
NIOSH. 2002a. In-depth survey report of exposure to silica from demolition of plaster ceilings at Frank Messer and Sons Construction Company: Columbus,
OH. Report # 247-15b. National Institute for Occupational Safety and Health, Cincinnati, OH, January, 2002.
NIOSH. 2002b. Pocket guide to chemical hazards. Pub. No. 2002-140. National Institute for Occupational Safety and Health, Cincinnati, OH.
Plinke, M.A.E., Maus, R. and Leith, D. 1992. Experimental examination of factors that affect dust generation by using Heubach and MRI testers. Am. Ind. Hygiene. Assn. J. 53(5):325-330. May, 1992.
Riala, R. 1988. Dust and quartz exposure of Finnish construction site cleaners. Ann. Occup. Hygiene 32(2):215-220, 1988.
Saunders, Mark. 2000. Just say ‘No’ to dust…maybe. Grading and Excavation Contractor. May/June. www.forester.net/gec_0005_just.html.
Skorseth, K. and Selim, A.. 2000. Gravel Roads Maintenance and Design Manual. USDOT, Federal Highway Administration. November, 2000.
Smandych, R.S., Thomson, M. and Goodfellow, H. 1998. Dust control for material handling operations: a systematic approach. Am. Ind. Hygiene Assn. J. 58:139-146. February, 1998.
Trakumas, S., Willeke, K., Ginshpun, S.A., Reponen, T., Mainelis, G. and Freidman, W. 2001. Particle emission characteristics of filter-equipped vacuum cleaners. Am. Ind. Hygiene Assn. J. 62:482-493. July/August, 2001.
Westbrook, T. 1999. Managing fugitive dust. Presentation made at the Pollution Prevention Seminar for the Mining and Mineral Industries, Options for Reducing Dust Emissions, held in Mesa,
AZ, on September 16, 1999. References: Flanagan et al., 2003; NIOSH, 2002a, 1999a, 1999b; OSHA Case Files; Riala, 1988.
NIOSH conducted video and real-time respirable dust monitoring in the employee’s breathing zone and simultaneously captured respirable dust on a cassette for gravimetric and X-ray diffraction analysis. Results indicated the respirable dust on the filter was 14.5 percent silica. This percentage was used to calculate the approximate silica exposure associated with the videotaped activities. NIOSH also sampled the employee’s full shift using traditional methods. Results indicated an 8-hour time-weighted average respirable silica exposure of 0.155 mg/m3 (0.182 mg/m3 for the 410-minute period sampled) (NIOSH, 2001b). Laboratories have not used particle counting for crystalline silica analysis for many years. Exposure data is now reported gravimetrically. However,
ACGIH recommends 3,500 to 4,000 feet per minute (FPM) velocity (within the hose/duct) to keep concrete dust and particles released from grinding from settling in the hose (ACGIH, 2001). For a typical 2-
EXPOSURES CONSTRUCTION inch diameter vacuum hose, 75 to 90 cubic feet per minute (CFM) will achieve that duct velocity (ACGIH, 2001). However, for maximum collection efficiency, the shroud may require higher CFM.