Ex. #136: Occupational Safety and Health Administration. (2009). Controlling silica exposures in construction (OSHA 3362-05 2009).
Other documents for the same rulemaking (all, by stage)
References: 208 extracted, 0 linked to papers
Orlando, FL. May 24, 2000. Zalk, D. 2001. Personal communication between D.
Arlington, VA. January 23, 2001. Zalk, D. 2002. Personal communication between D.
Long, Eastern Research Group, Inc., Arlington, VA. October 29, 2002. Technical Notes Laboratories have not used particle counting for crystalline silica analysis in many years and now Copper tubing, heavy rubber, plastic tubing, and even hydraulic line have been used. The more flexible the tubing, the easier it is to adjust the nozzle position when installing the system. Under many conditions, 1/8 gallon per minute water flow will generate little run-off. Requirements, however, vary greatly by location. Contact the municipal environmental quality department or other appropriate authority to see if there are any local requirements.
OSHA Case Files; Shields, 2000a [data of 8/13]. Although visible dust cannot be used to predict the amount of respirable-sized dust in the air, if the spray is not controlling the visible dust, it is probably not controlling respirable dust either. Based on the limit of detection, the employee’s respirable silica exposure was calculated to be less than or equal to 0.037 mg/m3. All sample durations were 1 to 3 hours. This level is higher than typical on indoor construction sites, probably because the enclosed shed used in the test was smaller and had less natural ventilation than the indoor spaces evaluated for
ACGIH. 2007. Industrial Ventilation, a Manual of Recommended Practice, 26th edition. American Conference of Governmental Industrial Hygienists,
Cincinnati, OH, 2001. ACGIH. 2008. Threshold limit values for chemical substances and physical agents and biological exposure indices. American Conference of Governmental Industrial Hygienists, Cincinnati. OH, 2008.
CS UNITEC. 2003. Air Rotary Hammer Drill. http://www.csunitec.com/ rotary/airrotary.html. Accessed January 13, 2003.
Hallin, N. 1983. Occurrence of quartz in the construction sector (Report 1983-04-01). Bygghälsan— The construction industry’s organization for working environment, safety and health. Stockholm, Sweden. April 1, 1983.
Heitbrink, W.A. and D.S. Watkins. 2001. The effect of exhaust flow rate upon the respirable dust emissions for tuckpointing operations. In: In-Depth Study Report: Control Technology for Crystalline Silica Exposures in Construction. U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health. ECTB No. 247-18, 2001.
LBL. Undated. Asbestos management program, appendix G, Bulk sampling procedure. Lawrence Berkeley National Laboratory. Berkeley, CA.: http://www.lbl.gov/ehs/ih/forms/AsbesProg.doc. Accessed January 13, 2003.
Lofgren, D.J. 1993. Silica exposure for concrete workers and masons. Appl. Occup. Environ. Hyg. 8(10):832-836, 1993.
NIOSH. 1996. Preventing silicosis and deaths in conCONTROLLING
NIOSH. 1999. Control technology and exposure assessment for occupational exposure to crystalline silica: Case 22 – rock drilling (ECTB 233-122c). National Institute for Occupational Safety and
Health, Cincinnati, OH. November 19, 1999.
NIOSH. 2002. Pocket guide to chemical hazards. Pub. No. 2002-140. National Institute for Occupational Safety and Health, Cincinnati, OH. June.
Organiscak, J.A. and S.J. Page. 1996. Assessment of airborne dust generated from small truck-mounted rock drills. Report of Investigation No. 9616. U.S. Department of the Interior, Bureau of Mines,
Pittsburgh, PA. OSHA Case Files (Special Emphasis Program Inspection Reports from 1996-1998).
Sam, K. 2000. Control measures for reducing employee exposure to concentrations of total and respirable silica in the ready-mix concrete industry during drum cleaning. Presentation at American Industrial Hygiene Conference & Exposition.
Orlando, FL. May 24, 2000. Shepherd, S., Woskie, S.R., Holcroft, C. and
Ellenbecker, M. 2009. Reducing Silica and Dust Exposures in Construction During Use of Powered Concrete-Cutting Hand Tools: Efficacy of Local Exhaust Ventilation on Hammer Drills. Journal of Occupational and Environmental Hygiene, 6:1,42-51, 2009. U.S. GSA. 2001. Standard operating procedure for asbestos operations and maintenance activities. Appendix B: Cleaning above a drop ceiling--minicontainment methods. U.S. General Services
Administration, Kansas City, MO. July. http://safety. gsa.gov/gsa/heartland/sops/acm_sop.pdf. Accessed January 13, 2003.
Woods, David T. 2000. A common sense approach to disturbing asbestos. Ind. Safety & Hyg. News Online. www.ishn.com/CDA/ArticleInformation/features/BNP___Features___Item/0,2162,2572,00.html. Accessed January 15, 2003.
Zalk, D. 2000. Presentation at American Industrial Hygiene Conference & Exposition. Orlando, FL. May 24, 2000.
Long, Eastern Research Group, Inc., Arlington, VA. October 29, 2002.
EXPOSURES CONSTRUCTION Technical Notes The three respirable crystalline silica results cited are 0.3, 0.26, and 0.11 mg/m3, collected as 457-, 110and 177-minute samples, respectively (Lofgren, 1993). Laboratories have not used particle counting for crystalline silica analysis in many years and now report exposure data gravimetrically. However,
OSHA’s general industry permissible exposure limit (PEL).1 Furthermore, the U.S. Bureau of Mines found that respirable silica concentrations averaged 2.13 mg/m3 in the immediate vicinity of small surface drilling operations (U.S. Bureau of Mines, 1995). Concentrations of respirable silica in soil and rock may vary widely depending on the type of underlying rock formation and history of volcanic eruptions. For example, the preliminary site investigation of the Department of Energy’s Yucca Mountain site indicated that soil concentrations of cristobalite (a form of silica) ranged from 18 to 28 percent, and many job tasks were associated with overexposure (CRWMS 1999). If a construction company will be doing substantial excavation at a site, then obtaining a profile of the silica content of soil and rock from bulk samples of the projected excavation represents good industrial hygiene practice. Many times this information can be obtained as part of the project design and provided to the contractor
CONTROLLING SILICA Earth drilling rigs operated without dust controls are capable of producing very high respirable silica levels (Photo courtesy of NIOSH, 1992.) Silica Dust Control Measures Dust Collection Systems Various types of dust collection systems are available for earth drills. Commonly used equipment incorporates a movable suction duct attached to a shroud (a flexible rubber skirt) that encloses the drill hole opening and captures the cuttings coming through the hole. Drilling equipment that does not include these controls can be retrofitted by the manufacturer or a mechanical shop. Dusty air pulled from the shroud enclosure usually passes through a flexible duct leading to a primary dust separator and a secondary filter system. The dust separator often includes a self-cleaning “back-pulse” feature that discharges the collected particles to the ground. Some secondary filter systems are also self-cleaning. Finally, the exhaust air is discharged to the atmosphere. Design Considerations Dust collection systems are commercially available and work well in all climates and with all drill types. If the systems are well designed, dust collectors offer substantial dust reduction. Some important design factors are described below. Drill Bit Shroud Design. Conventional shrouds are rectangular and constructed of four separate
ACGIH. 2001. Industrial Ventilation, A Manual of Recommended Practice. 24th Edition. American Conference of Governmental Industrial Hygienists.
Cincinnati, OH, 2001. ACGIH. 2008. Threshold limit values for chemical substances and physical agents and biological exposure indices. American Conference of Governmental Industrial Hygienists, Cincinnati, OH, 2008.
CRWMS. 1999. Engineering File – Subsurface Repository. Civilian Radioactive Waste Management System Management & Operating Contractor. BCA000000-01717-5705-00005 Rev 02, DCN 01. June, 1999.
ERG. 2003. Technological Feasibility Study and Cost Impact Analysis of the Draft Crystalline Silica Standard for Construction. Table 2, Ranking of dust control technology, ERG composite of available research on control technology. February, 2003.
NIOSH ALERT, 1992a. Preventing Silicosis and Deaths in Rock Drillers. No. 92-107.
NIOSH. 1992b. Environmental surveillance report: Breckinridge Construction Drilling, Westover, WV. National Institute for Occupational Safety and
Morgantown, WV, 1992. EXPOSURES CONSTRUCTION
NIOSH. 1997. Silica…it’s not just dust – What rockdrillers can do to protect their lungs from silica dust. U.S. Dept. of Health and Human Services (National Institute for Occupational Safety and Health, Publication No. 97-118), available at <http://www. cdc. gov/niosh/rock.html>. Accessed November 22, 2002.
NIOSH. 1998. New shroud design controls silica dust for surface mine and construction blast-hole drills. U.S. Dept. of Health and Human Services (National Institute for Occupational Safety and
Health, Publication No. 98-150), 1998. NIOSH. 2002. Pocket guide to chemical hazards. Pub. No. 2002-140. National Institute for Occupational Safety and Health, Cincinnati, OH.
June, 2002. Organiscak, J.A. 2002. Personal communication between J. Organiscak, National Institute for Occupational Safety and Health, Pittsburgh, PA, and W. Long of Eastern Research Group, Inc. November 21, 2002.
Organiscak, J.A. and S.J. Page. 1996. Assessment of airborne dust generated from small truck-mounted rock drills. Report of investigation No. 9616. U.S. Department of the Interior, Bureau of Mines,
Pittsburgh, PA, 1996. OSHA Case Files (Special Emphasis Program Inspection Reports from 1996-1998). (See Appendix E to OSHA’s National Emphasis Program for Crystalline Silica, CPL 03-00-007, for a detailed discussion of the conversion factor used to transform gravimetric measurements to particlecount values). In this guidance, OSHA is using 0.1 mg/m3 of respirable quartz as an 8-hour timeweighted average as a benchmark to describe the effectiveness of control measures. The benchmark is approximately equivalent to the general industry silica PEL. Other organizations suggest more stringent levels. For example, the National Institute for Occupational Safety and Health (NIOSH) recommends that respirable crystalline silica exposures be limited to 0.05 mg/m3 as a 10-hour time-weighted average (NIOSH, 2002). The American Conference of Governmental Industrial Hygienists (ACGIH) recommends that respirable crystalline silica exposures be limited to 0.025 mg/m3 as an 8-hour time-weighted average (ACGIH, 2008). To avoid clogging, ACGIH (2001) recommends 3,500 to 4,000 feet per minute (FPM) minimum air velocity through ducts carrying rock or concrete dust. Use a higher velocity of at least 4,500 FPM if dust is moist or contains small chips. Bit size, hole depth, substrate and weather all affect the amount of water needed to control dust. The usage rate must be adjusted for each individual operation, but typically will be about ½ to 1 gallon per minute.
Page, S.J. 1991. Respirable dust control on overburdened drills at surface mines. American Mining
Congress, Coal Convention. June 5, 1991. Page, S.J. and J.A. Organiscak. 1995. Taming the dust devil: an evaluation of improved dust controls for surface drills using Rotoclone collectors. Engineering and Mining Journal, pp. ww30 – ww31.
November, 1995. U.S. Bureau of Mines. 1995. Dust collector discharge shroud reduces dust exposure to drill operators at surface coal mines. Technology News. No. 447.
March, 1995. Zimmmer, A.T. 1997. Comparative evalution of dust control technologies on percussion rock-drilling rigs. Appl. Occup. Environ. Hyg. 12(12): 782-788.
December, 1997. Certain drill systems use large quantities of water, rather than air, to flush cuttings from the hole. The large volume of water in the hole usually controls dust completely and additional devices, such as dust collectors, offer very little extra benefit. High air velocity and turbulence in the flexible duct atomize the water drops to create a mist, which captures dust as it moves down the length of the duct (Organiscak, 2002). To measure water flow rate, adjust the flow as desired, then check how long it takes to fill a onegallon milk container. To better exclude dust, pressurize the cab interior by using a pressurization unit to introduce filtered outside air into the cab. Studies show that 100 cubic feet per minute (CFM) provides adequate pressure (0.2 inches of water gauge) to keep dust from leaking into a well-sealed 100 cubic foot cab. Bulk samples indicated the granite contained 30 to 40 percent crystalline silica. Technical Notes Laboratories have not used particle counting for crystalline silica analysis in many years and now report exposure data gravimetrically. However,
Nonetheless, drywall joint compounds may contain varying amounts of silica and drywall finishing employees can be overexposed in certain circumstances. For example, by using a joint compound containing just 3 percent silica, an employee could exceed the Occupational Safety and Health Administration’s (OSHA) benchmark of 0.1 mg/m³ (milligrams of silica per cubic meter of air) as an 8-hour time-weighted average (TWA), an exposure approximately equivalent to OSHA’s general industry permissible exposure limit (PEL), during intensive periods of uncontrolled drywall sanding on ceilings. One study of drywall sanding, in which a silica-containing joint compound was used, found that the respirable silica level exceeded 0.15 mg/m³ (NIOSH, 1997).1,2 The potential for silica exposure is also indicated by the results of NIOSH tests of settled drywall dust.
NIOSH found that dust generated during drywall sanding contained up to 6 percent silica (NIOSH, 1995). Other studies found that silica constituted up to 3.7 percent of the airborne respirable dust collected in drywall sanding employees’ breathing zones (NIOSH, 1997; Epling et al., 1999).3 Drywall sanding employees can also experience total dust exposures substantially above OSHA limits. In one study, employees using hand sanders without controls had exposures up to 143.1 mg/m³ of total dust. Similarly, employees using conventional pole-mounted sanders were exposed to up to 35.1 mg/m³ of total dust (CPWR, 1998).4 Although both of these exposures exceed regulatory limits, these results demonstrate that pole sander use can reduce dust exposures by increasing the distance between the employee and the point of work. An earlier NIOSH study also found lower exposures for employees using pole-mounted drywall sanders compared to handheld sanding (NIOSH, 1995).
Additionally, NIOSH (1997) found that some of the highest dust exposures occur when employees sand joint compound in enclosed spaces, such as closets or small rooms. Poor air exchange in these areas causes dust levels to build up when dust controls are not used. Increasing or decreasing dust dissipation (by increasing distance to the employee or decreasing air exchange) affects respirable dust levels as well as total dust levels. For example, concrete finishers using a long-angled jig to grind a ceiling had lower
EXPOSURES CONSTRUCTION silica exposures than employees grinding concrete with equipment attached to a short section of pipe and held directly overhead (OSHA Case Files). Employees grinding concrete indoors had higher respirable silica exposures than employees performing the same task outdoors, where dust could dissipate more quickly (Lofgren, 1993; NIOSH, 2001;
OSHA Case Files). percent when used during pole sanding and 95 percent for hand sanding. Both of the resulting exposure levels were well below regulatory limits for total dust (CPWR, 1998). Figure 1 shows the average reduction in airborne dust measured for four drywall sanding operations—pole-mounted sanding and hand sanding with and without vacuum dust control measures from the CPWR study.6 Silica-Free Joint Compounds Many manufacturers offer joint compounds that contain little or no silica. In a study of six brands of joint compound purchased at retail stores, no crystalline silica was detected in three brands (NIOSH, 1997). The silica present in a sample of one of the six products, however, was substantially different from the percentage listed on the material safety data sheet (MSDS) for that product.5 Nonetheless,