{"document":{"doc_id":285638,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #136: Occupational Safety and Health Administration. (2009). Controlling silica exposures in construction (OSHA 3362-05 2009).","date":"2014-10-10","url":"https://www.regulations.gov/document/OSHA-2012-0023-0053","source_native_id":"OSHA-2012-0023-0053","status":"fetched","abstract":null,"action":null},"dockets":["OSHA-2012-0023"],"rins":["RIN 1218-AC74"],"related":[{"doc_id":11249,"source":"fr_rule","org":"DEPARTMENT OF LABOR; Occupational Safety and Health Administration","doc_type":"Proposed Rule","title":"Chemical Management and Permissible Exposure Limits (PELs)","date":"2014-10-10"},{"doc_id":54120,"source":"ria","org":"OSHA","doc_type":"regulatory_flexibility_analysis","title":"Ex. #101: Occupational Safety and Health Administration. (2006a). Final economic and regulatory flexibility analysis for OSHA’s final standard for occupational exposure to hexavalent chromium.","date":"2014-10-10"},{"doc_id":54495,"source":"ria","org":"OSHA","doc_type":"regulatory_flexibility_analysis","title":"Ex. #103: Occupational Safety and Health Administration. (1984). Regulatory impact and regulatory flexibility analysis of the final standard for ethylene oxide.","date":"2014-10-10"},{"doc_id":54502,"source":"ria","org":"OSHA","doc_type":"regulatory_flexibility_analysis","title":"Ex. #100: Occupational Safety and Health Administration. (1996). Final economic and regulatory flexibility analysis for OSHA’s standard for occupational exposure to methylene chloride.","date":"2014-10-10"},{"doc_id":54514,"source":"ria","org":"OSHA","doc_type":"regulatory_flexibility_analysis","title":"Ex. #102: Occupational Safety and Health Administration. (1987). Regulatory impact and regulatory flexibility analysis of the formaldehyde standard.","date":"2014-10-10"},{"doc_id":246492,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #135: National Institute for Occupational Safety and Health (NIOSH). (2009). Qualitative risk characterization and management of occupational hazards: control banding (CB), a literature review and critical analysis (DHHS (NIOSH) Publication No. 2009-152).","date":"2014-10-10"},{"doc_id":246494,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #34: Presidential/Congressional Commission on Risk Assessment and Risk Management (PCRARM). (1997). Risk assessment and risk management in regulatory decision-making. Retrieved from: http://cfpub.epa.gov/ncea/cfm/pcrarm.cfm","date":"2014-10-10"},{"doc_id":246495,"source":"docket_item","org":"OSHA","doc_type":"report","title":"Ex. #145: Federal Advisory Committee on Occupational Safety and Health (FACOSH). (2012). Recommendations for Consideration by the U.S. Secretary of Labor on the Adoption and Use of Occupational Exposure Limits by Federal Agencies.","date":"2014-10-10"},{"doc_id":246498,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #90: Institut für Arbeitsschutz der Deutschen Gesetzlichen Unfallversicherung (IFA). (2011). The GHS Column Model:  An aid to substitute assessment. Berlin, Germany: Deutsche Gesetzliche Unfallversicheung e.V. (DGUV).","date":"2014-10-10"},{"doc_id":246499,"source":"docket_item","org":"OSHA","doc_type":"report","title":"Ex. #91: Netherlands Ministry of Infrastructure and the Environment. (2002). Implementation strategy on management of substances:  2nd progress report. Retrieved from: http://www.subsport.eu/images/stories/pdf_archive/substitution_tools/15_quick_scan_en.pdf.","date":"2014-10-10"},{"doc_id":246503,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #123: Washington Department of Ecology. (2012). Ecology Quick Chemical Assessment Tool 1.2 Methodology.  Retrieved from:  http://www.ecy.wa.gov/programs/hwtr/ChemAlternatives/documents/QCAT2012-03-20final.pdf","date":"2014-10-10"},{"doc_id":246504,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #32: U.S. Environmental Protection Agency. (2005).  Guidelines for carcinogen risk assessment (EPA/630/P-03/001F).","date":"2014-10-10"},{"doc_id":246505,"source":"docket_item","org":"OSHA","doc_type":"data","title":"European Chemicals Agency (ECHA). (2012). Information Requirements.  Retrieved from:  http://echa.europa.eu/web/guest/regulations/reach/substance-registration/information-requirements.  Information Requirements","date":"2014-10-10"},{"doc_id":246507,"source":"docket_item","org":"OSHA","doc_type":"report","title":"Ex. #105: Occupational Safety and Health Administration. (2010). Regulatory Review of 29 CFR 1910.1052:  Methylene chloride.","date":"2014-10-10"},{"doc_id":246510,"source":"docket_item","org":"OSHA","doc_type":"report","title":"GAO Report 12-330 - Multiple Challenges Lengthen OSHA’s Standard Setting.  U.S. Government Accountability Office. (2012).","date":"2014-10-10"},{"doc_id":246512,"source":"docket_item","org":"OSHA","doc_type":"data","title":"Ex. #72:  European Chemicals Agency (ECHA). (2012). Information on Chemicals.  Retrieved from:  http://echa.europa.eu/web/guest/information-on-chemicals","date":"2014-10-10"},{"doc_id":246513,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #120: U.S. Environmental Protection Agency. (2012c). Alternatives assessments. Retrieved from: http://www.epa.gov/dfe/alternative_assessments.html.","date":"2014-10-10"},{"doc_id":246516,"source":"docket_item","org":"OSHA","doc_type":"data","title":"Ex. #74:  European Chemicals Agency (ECHA). (2012). Evaluation.  Retrieved from:  http://echa.europa.eu/regulations/reach/evaluation.  Evaluation","date":"2014-10-10"},{"doc_id":246519,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #41: U.S. Environmental Protection Agency. (2013b). NexGen: Advancing the Next Generation of Risk Assessment. Retrieved from: http://www.epa.gov/risk/nexgen","date":"2014-10-10"},{"doc_id":246522,"source":"docket_item","org":"OSHA","doc_type":"report","title":"Ex. #104: Occupational Safety and Health Administration. (2005). Regulatory Review of the Occupational Safety and Health Administration’s Ethylene Oxide Standard [29 CFR 1910.1047].","date":"2014-10-10"},{"doc_id":285613,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #7:  Air Contaminants, 54 Federal Register 2332 (Jan. 19, 1989) - Part 1.  2332 Federal Register / Vol. 54, No. 12 / Thursday, January 19, 1989 / Rules and Regulations  DEPARTMENT OF LABOR\r\nOccupational Safety and Health\r\nAdministration\r\n29 CFR Part 1910\r\nAir Contaminants\r\nAGENCY: Occupational Safety and\r\nHealth Administration, Labor.\r\nACTION: Final rule","date":"2014-10-10"},{"doc_id":285615,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #115: German Federal Institute for Occupational Safety and Health (BAuA), Technical Rule on Hazardous Substances (TRGS) 600 (Aug. 2008).","date":"2014-10-10"},{"doc_id":285616,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #92: Identification, Classification, and Regulation of Potential Occupational Carcinogens, 45 Fed. Reg. 5258 (Jan. 22, 1980).","date":"2014-10-10"},{"doc_id":285618,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #111: Safe Alternatives Policy, 42 U.S.C. 7671K (2011).","date":"2014-10-10"},{"doc_id":285619,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #89: U.S. Environmental Protection Agency. (2011a). DfE’s standard and criteria for safer chemical ingredients. Retrieved from: http://www.epa.gov/dfe/pubs/projects/gfcp/index.htm#.","date":"2014-10-10"},{"doc_id":285620,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #1:  U.S. Environmental Protection Agency. (2013a). 2012 Chemical Data Reporting Results. Retrieved from: http://epa.gov/cdr/pubs/guidance/cdr_factsheets.html","date":"2014-10-10"},{"doc_id":285621,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #43: National Institute for Occupational Safety and Health. (2011a). Experimental and Numerical Research on the Performance of Exposure Control Measures for Aircraft Painting Operations, Part I (EPHB Report No. 329-12a).","date":"2014-10-10"},{"doc_id":285622,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #4:  Air Contaminants, Tables Z-1, Z-2, and Z3, 29 C.F.R. PT. 1910.1000 (2012).  Pages 9-19.","date":"2014-10-10"},{"doc_id":285623,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #11:  Occupational Exposure to Formaldehyde Final Rule, 52 Fed. Reg. 46168 (December 4, 1987)","date":"2014-10-10"},{"doc_id":285624,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #116: German Environment Agency (Umweltbundesamt). (2011). Guide on sustainable chemicals:  A decision tool for substance manufacturers, formulators, and end users of chemicals.  Retrieved from:  http://www.umweltdaten.de/publikationen/fpdf-l/4169.pdf.","date":"2014-10-10"},{"doc_id":285625,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #106: Occupational Safety and Health Administration. (2006b). Best practices for the safe use of glutaraldehyde in health care (OSHA 3254-08N 2006).","date":"2014-10-10"},{"doc_id":285627,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #119:  SUBSPORT.  (2012). Substitution Support Portal. Retrieved from: http://www.subsport.eu/about-the-project","date":"2014-10-10"},{"doc_id":285628,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #65: U.S. Government Accountability Office (GAO). (2007). Chemical regulation:  comparison of U.S. and recently enacted European Union approaches to protect against the risks of toxic chemicals (GAO-07-825).","date":"2014-10-10"},{"doc_id":285630,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #45: National Institute for Occupational Safety and Health. (2011b). NORA Manufacturing Sector Strategic Goals. Retrieved from: http://www.cdc.gov/niosh/programs/manuf/noragoals/projects/921Z6KR.html","date":"2014-10-10"},{"doc_id":285632,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #6:  Gases, vapors, fumes, dusts, and mists, 29 C.F.R. § 1926.55 (2012).","date":"2014-10-10"},{"doc_id":285633,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #20:  Unified Agenda, The Regulatory Plan, DOL-OSHA, Permissible Exposure Limits (PELS) for Air Contaminants, 60 Fed. Reg. 59628 (Nov. 28, 1995).","date":"2014-10-10"},{"doc_id":285636,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #118: Institute of Work, Environment, and Health (ISTAS). (2012). RISCTOX. Retrieved from: http://www.istas.net/risctox/en/.","date":"2014-10-10"},{"doc_id":285637,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #99: Occupational Exposure to Hexavalent Chromium, 71 Fed. Reg. 10099 (Feb. 28, 2006).","date":"2014-10-10"},{"doc_id":285640,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #62: Toxic Substances Control Act, 15 U.S.C. §§ 2601-2629 (2011).","date":"2014-10-10"},{"doc_id":285642,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #67: U.S. Environmental Protection Agency. (2012b). Ecological Structure Activity Relationships (ECOSAR). Retrieved from: http://www.epa.gov/oppt/newchems/tools/21ecosar.htm","date":"2014-10-10"},{"doc_id":285643,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #50: National Institute of Standards and Technology(NIST). (1997). Use of Computational Fluid Dynamics to Analyze Indoor Air Quality Issues (NISTIR 5997).","date":"2014-10-10"},{"doc_id":285644,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #31: Environmental Protection Agency –Integrated Risk Information System (1994) Methods for derivation of inhalation reference concentrations and applications of inhalation dosimetry. Washington, DC (EPA/600/8-90/066f).","date":"2014-10-10"},{"doc_id":285646,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #22:  Unified Agenda, The Regulatory Plan, DOL-OSHA, Permissible Exposure Limits (PELS) for Air Contaminants, 66 Fed. Reg. 61882 (Dec. 3, 2001).","date":"2014-10-10"},{"doc_id":285649,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #98: Occupational Exposure to Methylene Chloride, 62 Fed. Reg. 1494 (Jan. 10, 1997).","date":"2014-10-10"},{"doc_id":285651,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #70: Regulation of the European Parliament and of the Council Concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH), EC No. 1907/2006 (2006).","date":"2014-10-10"},{"doc_id":285652,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #56: U.S. Environmental Protection Agency. (2012a). High Production Volume Information System (HPVIS).  Retrieved from: http://www.epa.gov/chemrtk/hpvis/index.html.","date":"2014-10-10"},{"doc_id":285654,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #35: U.S. Environmental Protection Agency. (2002). A review of the reference dose and reference concentration processes (EPA/630/P-02-002F).","date":"2014-10-10"},{"doc_id":285655,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #51: National Institute of Standards and Technology (NIST). (2009). NIST Technical Note 1637: Modeling the Effects of Outdoor Gasoline Powered Generator Use on Indoor Carbon Monoxide Exposures.","date":"2014-10-10"},{"doc_id":285656,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #5:  Air Contaminants, 29 C.F.R. § 1915.1000 (2012).","date":"2014-10-10"},{"doc_id":285657,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #143: Longshore and Harbor Workers’ Compensation, 33 U.S.C. §§ 901-950 (2006).","date":"2014-10-10"},{"doc_id":285659,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #124:  Hazard Communication: 29 CFR 1910.1200(2012).","date":"2014-10-10"},{"doc_id":285661,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #96: Respiratory Protection, 29 C.F.R. pt. 1910.134(a) (2011).","date":"2014-10-10"},{"doc_id":285664,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #38: U.S. Environmental Protection Agency. (2011). Guidance for applying quantitative data to develop data-derived extrapolation factors for interspecies and intraspecies extrapolation (EPA/100/J-11/001). Retrieved from: http://www.epa.gov/raf/files/ddef-external-review-draft05-11-11.pdf","date":"2014-10-10"},{"doc_id":285666,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #19:  Air Contaminants Final Rule, 58 Fed. Reg. 35338 (Jun. 30, 1993).","date":"2014-10-10"},{"doc_id":285667,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Marine Terminals, 29 C.F.R. §§ 1917.2, 1917.22, 1917.23, 1917.25 (2012)","date":"2014-10-10"},{"doc_id":285669,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #131: Health and Safety Executive. (2009). The technical basis for COSHH essentials: easy steps to control chemicals. Retrieved from: http://coshh-essentials.org.uk/assets/live/CETB.pdf.","date":"2014-10-10"},{"doc_id":285670,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #93:  29 CFR 1910.111(k): OSHA Cancer Policy  (2011).","date":"2014-10-10"},{"doc_id":285673,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #122: U.S. Environmental Protection Agency. (2012d). Overview of National Research Council toxicity testing strategy. Retrieved from: http://www.epa.gov/pesticides/science/nrc-toxtesting.html","date":"2014-10-10"},{"doc_id":285674,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #40: National Toxicology Program (NTP). (2013). High Throughput Screening Initiative. Retrieved from: http://ntp.niehs.nih.gov/go/28213","date":"2014-10-10"},{"doc_id":285676,"source":"docket_item","org":"OSHA","doc_type":"publication","title":"Ex. #18:  Air Contaminants Proposed Rule, 53 Fed. Reg. 20960 (Jun. 7, 1988).","date":"2014-10-10"}],"references":[{"citation_id":3743095,"raw_reference":"ACGIH. 2007. Industrial Ventilation, A Manual of Recommended Practice, 26th Edition. American Conference of Governmental Industrial Hygienists,","cited_authors":"ACGIH","cited_year":"2007","cited_title":"Industrial Ventilation, A Manual of Recommended Practice, 26th Edition","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743096,"raw_reference":"Cincinnati, OH. ACGIH. 2008. Threshold limit values for chemical substances and physical agents and biological exposure indices. American Conference of Governmental Industrial Hygienists, Cincinnati, OH.","cited_authors":"Cincinnati, OH. ACGIH","cited_year":"2008","cited_title":"Threshold limit values for chemical substances and physical agents and biological exposure indices","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743097,"raw_reference":"Croteau, G.A. 2000. The effect of local exhaust ventilation controls on dust exposures during masonry activities. MS Thesis. University of Washington. June, 2000.","cited_authors":"Croteau, G.A","cited_year":"2000","cited_title":"The effect of local exhaust ventilation controls on dust exposures during masonry activities","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743098,"raw_reference":"Seixas, N.S. 2002. The effect of local exhaust ventilation controls on dust exposures during concrete cutting and grinding activities. Am Ind Hygiene","cited_authors":"Seixas, N.S","cited_year":"2002","cited_title":"The effect of local exhaust ventilation controls on dust exposures during concrete cutting and grinding activities","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743099,"raw_reference":"Assn J. 63:458-467. July/August. ERG. 2000. Site visit report - Masonry Training","cited_authors":"Assn J. 63:458-467. July/August. ERG","cited_year":"2000","cited_title":"Site visit report - Masonry Training","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743100,"raw_reference":"VA. September, 2000. Heitbrink, W.A. and Watkins, D.S. 2001. The effect of exhaust flow rate upon the respirable dust emissions for tuckpointing operations. In: In-Depth Study Report: Control Technology for Crystalline Silica Exposures in Construction. U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health. ECTB No. 247-18.","cited_authors":"VA. September","cited_year":"2000","cited_title":"Heitbrink, W.A. and Watkins, D.S. 2001","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743101,"raw_reference":"Heitbrink, W. and Collingwood, S. 2005. Protecting Tuckpointing Workers from Silica Dust: Draft Recommendations for Ventilated Grinder. The Center to Protect Workers’ Rights (CPWR). www.cpwr.com","cited_authors":"Heitbrink, W. and Collingwood, S","cited_year":"2005","cited_title":"Protecting Tuckpointing Workers from Silica Dust: Draft Recommendations for Ventilated Grinder","cited_venue":null,"cited_doi":null,"cited_url":"www.cpwr.com","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743102,"raw_reference":"Lofgren, D.J. 1993. Silica exposure for concrete workers and masons. Appl Occup Environ Hygiene 8(10):832-836. October, 1993.","cited_authors":"Lofgren, D.J","cited_year":"1993","cited_title":"Silica exposure for concrete workers and masons","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743103,"raw_reference":"NIOSH. 1996. Preventing Silicosis and Deaths in Construction Workers. Publication No. 96-112. National Institute for Occupational Safety and Health.","cited_authors":"NIOSH","cited_year":"1996","cited_title":"Preventing Silicosis and Deaths in Construction Workers","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743104,"raw_reference":"EXPOSURES CONSTRUCTION NIOSH. 1999a. Control technology and exposure assessment for occupational exposure to crystalline silica: Case 16 - Wet Cutting of Concrete Masonry","cited_authors":"EXPOSURES CONSTRUCTION NIOSH","cited_year":"1999a","cited_title":"Control technology and exposure assessment for occupational exposure to crystalline silica: Case 16 - Wet Cutting of Concrete Masonry","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743105,"raw_reference":"October, 1999. Some employers use a hose connected to an external water source to provide a continuous flow of fresh water in place of recirculated water. This eliminates the need for pumps and filters, but requires substantially more water and produces more runoff.","cited_authors":"October","cited_year":"1999","cited_title":"Some employers use a hose connected to an external water source to provide a continuous flow of fresh water in place of recirculated water","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743106,"raw_reference":"NIOSH. 1999b. Control technology and exposure assessment for occupational exposure to crystalline silica: Case 18 - Cutting Brick and Concrete Masonry Units. ECTB 233-118c. National Institute for Occupational Safety and Health, Cincinnati, OH.","cited_authors":"NIOSH","cited_year":"1999b","cited_title":"Control technology and exposure assessment for occupational exposure to crystalline silica: Case 18 - Cutting Brick and Concrete Masonry Units","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743107,"raw_reference":"November, 1999. NIOSH. 2002. Pocket guide to chemical hazards. Pub.","cited_authors":"November","cited_year":"1999","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743108,"raw_reference":"No. 2002-140. National Institute for Occupational Safety and Health, Cincinnati, OH. June, 2002.","cited_authors":"No","cited_year":"2002-140","cited_title":"National Institute for Occupational Safety and Health, Cincinnati, OH. June, 2002","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743109,"raw_reference":"OSHA. 1996. Ground-fault protection on construction sites. Occupational Safety and Health Administration, Office of Training and Education. May, 1996.","cited_authors":"OSHA","cited_year":"1996","cited_title":"Ground-fault protection on construction sites","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743110,"raw_reference":"OSHA Case Files (Special Emphasis Program Inspection Reports from 1996-1998).","cited_authors":"OSHA Case Files (Special Emphasis Program Inspection Reports from","cited_year":"1996-1998","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743111,"raw_reference":"Shields, C. 2000. Database: Silica dust exposures associated with construction activities (version date: September 14, 2000). Occupational Safety and Health Administration, North Aurora Office, IL. Technical Notes Laboratories have not used particle counting for crystalline silica analysis for many years. Exposure data is now reported gravimetrically. However,","cited_authors":"Shields, C","cited_year":"2000","cited_title":"Database: Silica dust exposures associated with construction activities (version date: September 14, 2000)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743112,"raw_reference":"ACGIH. 2001. Industrial Ventilation, A Manual of Recommended Practice, 24th Edition. American Conference of Governmental Industrial","cited_authors":"ACGIH","cited_year":"2001","cited_title":"Industrial Ventilation, A Manual of Recommended Practice, 24th Edition","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743113,"raw_reference":"Hygienists, Cincinnati, OH. ACGIH. 2008. Threshold limit values for chemical substances and physical agents and biological exposure indices. American Conference of Governmental Industrial Hygienists, Cincinnati, OH.","cited_authors":"Hygienists, Cincinnati, OH. ACGIH","cited_year":"2008","cited_title":"Threshold limit values for chemical substances and physical agents and biological exposure indices","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743114,"raw_reference":"Seixas, N.S. 2002. The effect of local exhaust ventilation controls on dust exposures during concrete cutting and grinding activities. Am Ind Hygiene Assn J 63:458-467. July/August, 2002.","cited_authors":"Seixas, N.S","cited_year":"2002","cited_title":"The effect of local exhaust ventilation controls on dust exposures during concrete cutting and grinding activities","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743115,"raw_reference":"CONTROLLING SILICA Diamond Products. 2001. SpeediCut cut-off saws. http://diamondproducts.com. Accessed September 8, 2008.","cited_authors":"CONTROLLING SILICA Diamond Products","cited_year":"2001","cited_title":"SpeediCut cut-off saws","cited_venue":null,"cited_doi":null,"cited_url":"http://diamondproducts.com","ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743116,"raw_reference":"Heitbrink, W.A. and Watkins, D.S. 2001. The effect of exhaust flow rate upon the respirable dust emissions for tuckpointing operations. In: InDepth Study Report: Control Technology for Crystalline Silica Exposures in Construction. U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health. ECTB No. 247-18.","cited_authors":"Heitbrink, W.A. and Watkins, D.S","cited_year":"2001","cited_title":"The effect of exhaust flow rate upon the respirable dust emissions for tuckpointing operations","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743117,"raw_reference":"NIOSH. 1995. Environmental surveillance report: Concrete Coring, Inc., Enon, OH. U.S. Department of Health and Human Services, Public Health","cited_authors":"NIOSH","cited_year":"1995","cited_title":"Environmental surveillance report: Concrete Coring, Inc., Enon, OH. U.S. Department of Health and Human Services, Public Health","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743118,"raw_reference":"Studies, Morgantown, WV. NIOSH. 1996. Alert: request for assistance in preventing silicosis and deaths in construction workers. DHHS (NIOSH) Publication No. 96-112. U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control and","cited_authors":"Studies, Morgantown, WV. NIOSH","cited_year":"1996","cited_title":"Alert: request for assistance in preventing silicosis and deaths in construction workers","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743119,"raw_reference":"NIOSH. 1999a. Control technology and exposure assessment for occupational exposure to crystalline silica: Case 17 - dry cutting of concrete masonry units. U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, Division of Physical Sciences and Engineering,","cited_authors":"NIOSH","cited_year":"1999a","cited_title":"Control technology and exposure assessment for occupational exposure to crystalline silica: Case 17 - dry cutting of concrete masonry units","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743120,"raw_reference":"Cincinnati, OH. ECTB 233-117c. NIOSH. 1999b. Control technology and exposure assessment for occupational exposure to crystalline silica: Case 18 - cutting brick and concrete masonry units. U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, Division of Physical Sciences and Engineering,","cited_authors":"Cincinnati, OH. ECTB 233-117c. NIOSH","cited_year":"1999b","cited_title":"Control technology and exposure assessment for occupational exposure to crystalline silica: Case 18 - cutting brick and concrete masonry units","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743121,"raw_reference":"Cincinnati, OH. ECTB 233-118c. NIOSH. 1999c. Control technology and exposure assessment for occupational exposure to crys-","cited_authors":"Cincinnati, OH. ECTB 233-118c. NIOSH","cited_year":"1999c","cited_title":"Control technology and exposure assessment for occupational exposure to crys-","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743122,"raw_reference":"OH. ECTB 233-121c. NIOSH. 2002. Pocket guide to chemical hazards. Pub. No. 2002-140. National Institute for Occupational Safety and Health, Cincinnati, OH.","cited_authors":"OH. ECTB 233-121c. NIOSH","cited_year":"2002","cited_title":"Pocket guide to chemical hazards","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743123,"raw_reference":"June, 2002. OSHA. 1996. Ground-fault protection on construction sites. Occupational Safety and Health","cited_authors":"June","cited_year":"2002","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743124,"raw_reference":"May, 1996. OSHA Case Files (Special Emphasis Program Inspection Reports from 1996-1998).","cited_authors":"May","cited_year":"1996","cited_title":"OSHA Case Files (Special Emphasis Program Inspection Reports from 1996-1998)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743125,"raw_reference":"Partner Industrial Products. 2001. The Partner wet cutting system. http://www.partnerusa.com. Accessed September 8, 2008.","cited_authors":"Partner Industrial Products","cited_year":"2001","cited_title":"The Partner wet cutting system","cited_venue":null,"cited_doi":null,"cited_url":"http://www.partnerusa.com","ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743126,"raw_reference":"Shields, C. 2000. Database: Silica dust exposures associated with construction activities (version date: September 14, 2000). Occupational Safety and Health Administration, North Aurora Office,","cited_authors":"Shields, C","cited_year":"2000","cited_title":"Database: Silica dust exposures associated with construction activities (version date: September 14, 2000)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743127,"raw_reference":"Stihl. 2001. Cutquick cut-off machine accessories. http://www.stihlusa.com. Accessed September 8, 2008.","cited_authors":"Stihl","cited_year":"2001","cited_title":"Cutquick cut-off machine accessories","cited_venue":null,"cited_doi":null,"cited_url":"http://www.stihlusa.com","ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743128,"raw_reference":"Thorpe, A., Ritchie, A.S., Gibson, M.J. and Brown, R.C. 1999. Measurements of the effectiveness of dust control on cut-off saws used in the construction industry. Annals of Occup Hygiene 43 (7) 1443-1456. July, 1999.","cited_authors":"Thorpe, A., Ritchie, A.S., Gibson, M.J. and Brown, R.C","cited_year":"1999","cited_title":"Measurements of the effectiveness of dust control on cut-off saws used in the construction industry","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743129,"raw_reference":"Trakumas, S., Willeke, K., Reponen, T., Grinshpun, S.A. and Freidman, W. 2001. Comparison of filter bag, cyclonic, and wet dust collection methods in vacuum cleaners. Am Ind Hygiene Assn J 62:573583.","cited_authors":"Trakumas, S., Willeke, K., Reponen, T., Grinshpun, S.A. and Freidman, W","cited_year":"2001","cited_title":"Comparison of filter bag, cyclonic, and wet dust collection methods in vacuum cleaners","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743130,"raw_reference":"USF Surface Preparation Group. 2000b. Sawtec","cited_authors":"USF Surface Preparation Group","cited_year":"2000b","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743131,"raw_reference":"JS-90. www.surfacepreparation.com Accessed September 8, 2008.","cited_authors":"JS-90. www.surfacepreparation.com Accessed September 8","cited_year":"2008","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":"www.surfacepreparation.com","ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743132,"raw_reference":"USF Surface Preparation Group. 2002. Personal communication between USF and Laura Lewis of","cited_authors":"USF Surface Preparation Group","cited_year":"2002","cited_title":"Personal communication between USF and Laura Lewis of","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743133,"raw_reference":"ERG, Inc. January 28, 2002. Technical Notes Laboratories have not used particle counting for crystalline silica analysis for many years. Exposure data is now reported gravimetrically. However,","cited_authors":"ERG, Inc. January 28","cited_year":"2002","cited_title":"Technical Notes Laboratories have not used particle counting for crystalline silica analysis for many years","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743134,"raw_reference":"OSHA’s construction PEL for crystalline silica, established in 1971, is still listed as a particle-count value. (See Appendix E to OSHA’s National Emphasis Program for Crystalline Silica, CPL 03-00-007, for a detailed discussion of the conversion factor used to transform gravimetric measurements to particlecount values). In this guidance, OSHA is using 0.1 mg/m3 of respirable quartz as an 8-hour timeweighted average as a benchmark to describe the effectiveness of control measures. The benchmark is approximately equivalent to the general industry silica PEL. Other organizations suggest lower levels. For example, the National Institute for Occupational Safety and Health (NIOSH) recommends that respirable crystalline silica exposures be limited to 0.05 mg/m3 as a 10-hour time-weighted average (NIOSH, 2002). The American Conference of Governmental Industrial Hygienists (ACGIH) recommends that respirable crystalline silica exposures be limited to 0.025 mg/m3 as an 8-hour time-weighted average (ACGIH, 2008). Some saws come set up for both water-feed and vacuum dust collection for better employee protection in all situations. For the system tested by Croteau et al. (2002), an airflow of 90 cubic feet per minute (CFM) through the vacuum controlled respirable dust better than 70 CFM.","cited_authors":"OSHA’s construction PEL for crystalline silica, established in","cited_year":"1971","cited_title":"is still listed as a particle-count value","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743135,"raw_reference":"ACGIH (2001) recommends a still higher airflow of 25 CFM per inch of blade diameter (equivalent to 236 CFM for the saw tested). Low airflow can cause ducts to clog. For abrasive wheel saws with vacuum dust collection, ACGIH recommends a minimum airflow velocity of 4,000 feet per","cited_authors":"ACGIH","cited_year":"2001","cited_title":"recommends a still higher airflow of 25 CFM per inch of blade diameter (equivalent to 236 CFM for the saw tested)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743136,"raw_reference":"Zalk, D. 2000. Exposure assessment strategy for the reduction of airborne silica during jackhammering activities. Presentation. American Industrial Hygiene Conference and Exposition,","cited_authors":"Zalk, D","cited_year":"2000","cited_title":"Exposure assessment strategy for the reduction of airborne silica during jackhammering activities","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743137,"raw_reference":"ACGIH. 2001. Industrial Ventilation, A Manual of Recommended Practice, 24th Edition. American Conference of Governmental Industrial Hygienists,","cited_authors":"ACGIH","cited_year":"2001","cited_title":"Industrial Ventilation, A Manual of Recommended Practice, 24th Edition","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743138,"raw_reference":"Akbar-Khanzadeh, F. and Brillhart, R.L. 2002. Respirable crystalline silica dust exposure during concrete finishing (grinding) using handheld grinders in the construction industry. Ann Occup Hygiene 46(3):341-346.","cited_authors":"Akbar-Khanzadeh, F. and Brillhart, R.L","cited_year":"2002","cited_title":"Respirable crystalline silica dust exposure during concrete finishing (grinding) using handheld grinders in the construction industry","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743139,"raw_reference":"Seixas, N.S. 2002. The effect of local exhaust venti- Occupational Safety and Health Administration lation controls on dust exposures during concrete cutting and grinding activities. Am Ind Hygiene","cited_authors":"Seixas, N.S","cited_year":"2002","cited_title":"The effect of local exhaust venti- Occupational Safety and Health Administration lation controls on dust exposures during concrete cutting and grinding activities","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743140,"raw_reference":"OH. February, 2000. Echt, A. and Sieber, W.K. 2002. Control of silica exposure from hand tools in construction: Grinding concrete. Appl Occup Environ Hygiene 17(7):457461. July, 2002.","cited_authors":"OH. February","cited_year":"2000","cited_title":"Echt, A. and Sieber, W.K. 2002","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743141,"raw_reference":"NIOSH. 2000b. Control technology and exposure assessment for occupational exposure to crystalline silica: Case 25 – Concrete pipe manufacturing (ECTB 233-125c). National Institute for Occupational Safety and Health, Cincinnati, OH. March, 2000.","cited_authors":"NIOSH","cited_year":"2000b","cited_title":"Control technology and exposure assessment for occupational exposure to crystalline silica: Case 25 – Concrete pipe manufacturing (ECTB 233-125c)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743142,"raw_reference":"ERG. 2002. Site visit report: Precast concrete product manufacturer facility B. Eastern Research","cited_authors":"ERG","cited_year":"2002","cited_title":"Site visit report: Precast concrete product manufacturer facility B. Eastern Research","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743143,"raw_reference":"Group, Inc. September 26, 2002. Flanagan, M.E., Seixas, N., Majar, M., Camp, J. and","cited_authors":"Group, Inc. September 26","cited_year":"2002","cited_title":"Flanagan, M.E., Seixas, N., Majar, M., Camp, J. and","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743144,"raw_reference":"Morgan, M. 2003. Silica dust exposures during selected construction activities. Am Ind Hygiene","cited_authors":"Morgan, M","cited_year":"2003","cited_title":"Silica dust exposures during selected construction activities","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743145,"raw_reference":"Assn J. 64(3):319-28. May-June, 2003. Heitbrink, W.A. and Watkins, D.S. 2001. The effect of exhaust flow rate upon the respirable dust emissions for tuckpointing operations. In: In-Depth Study Report: Control Technology for Crystalline Silica Exposures in Construction. U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health. ECTB No. 247-18.","cited_authors":"Assn J. 64(3):319-28. May-June","cited_year":"2003","cited_title":"Heitbrink, W.A. and Watkins, D.S. 2001","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743146,"raw_reference":"Lofgren, D.J. 1993. Silica exposure for concrete workers and masons. Appl. Occup. Environ. Hygiene 8(10):832-836. October, 1993.","cited_authors":"Lofgren, D.J","cited_year":"1993","cited_title":"Silica exposure for concrete workers and masons","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743147,"raw_reference":"NIOSH. 1995. In-depth survey report: A Laboratory Comparison of Conventional Drywall Sanding Techniques versus Commercially Available Control (ECTB 208-11a). National Institute for Occupational Safety and Health.","cited_authors":"NIOSH","cited_year":"1995","cited_title":"In-depth survey report: A Laboratory Comparison of Conventional Drywall Sanding Techniques versus Commercially Available Control (ECTB 208-11a)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743148,"raw_reference":"NIOSH. 1996. Preventing Silicosis and Deaths in Construction Workers. Dept. of Health and Human Services (National Institute for Occupational Safety and Health, Publication No. 96-112).","cited_authors":"NIOSH","cited_year":"1996","cited_title":"Preventing Silicosis and Deaths in Construction Workers","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743149,"raw_reference":"NIOSH. 1998. Environmental surveillance report: Construction site #16, Covington, KY. National Institute for Occupational Safety and Health,","cited_authors":"NIOSH","cited_year":"1998","cited_title":"Environmental surveillance report: Construction site #16, Covington, KY. National Institute for Occupational Safety and Health","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743150,"raw_reference":"Morgantown, WV. June, 1998. NIOSH. 1999. Control technology and exposure assessment for occupational exposure to crystalline silica: Case 16 - Wet Cutting of Concrete Masonry","cited_authors":"Morgantown, WV. June","cited_year":"1998","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743151,"raw_reference":"Units, File No. ECTB 233-116c. National Institute for Occupational Safety and Health, October, 1999.","cited_authors":"Units, File No. ECTB 233-116c. National Institute for Occupational Safety and Health, October","cited_year":"1999","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743152,"raw_reference":"NIOSH. 2000a. In-depth survey report: Control technology for crystalline silica exposures in construction: Exposures and preliminary control evaluation at various sites for Bricklayers Local #9,","cited_authors":"NIOSH","cited_year":"2000a","cited_title":"In-depth survey report: Control technology for crystalline silica exposures in construction: Exposures and preliminary control evaluation at various sites for Bricklayers Local #9","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743153,"raw_reference":"CONTROLLING SILICA NIOSH. 2000c. Control technology and exposure assessment for occupational exposure to crystalline silica: Case 27 – Pre-cast concrete shape manufacturing (ECTB 233-127c). National Institute for Occupational Safety and Health, Cincinnati, OH.","cited_authors":"CONTROLLING SILICA NIOSH","cited_year":"2000c","cited_title":"Control technology and exposure assessment for occupational exposure to crystalline silica: Case 27 – Pre-cast concrete shape manufacturing (ECTB 233-127c)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743154,"raw_reference":"March, 2000. NIOSH 2000d. Control technology and exposure assessment for occupational exposure to crystalline silica: Case - 31 – A granite shed. (ECTB 233-131c). National Institute for Occupational Safety and","cited_authors":"March","cited_year":"2000","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743155,"raw_reference":"Health, Cincinnati, OH, August, 2000. NIOSH 2000e. Control technology and exposure assessment for occupational exposure to crystalline silica: Case-32 – A granite shed. (ECTB 233-132c). National Institute for Occupational Safety and","cited_authors":"Health, Cincinnati, OH, August","cited_year":"2000","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743156,"raw_reference":"Health, Cincinnati OH. August, 2000. NIOSH. 2001. In-depth survey report for four sites: Exposure to silica from hand tools in construction chipping, grinding and hand demolition at Frank Messer and Sons Construction Company, Lexington and Newport, KY, and Columbus and Springfield, OH (EPHB 247-15). National Institute for Occupational Safety and Health, Cincinnati, OH. April, 2001.","cited_authors":"Health, Cincinnati OH. August","cited_year":"2000","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743157,"raw_reference":"NIOSH. 2002a. In-depth survey report: Control of respirable dust and crystalline silica from grinding concrete at Frank Messer & Sons Construction,","cited_authors":"NIOSH","cited_year":"2002a","cited_title":"In-depth survey report: Control of respirable dust and crystalline silica from grinding concrete at Frank Messer & Sons Construction","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743158,"raw_reference":"May, 2002. NIOSH. 2002b. In-depth survey report: Control of silica exposure from hand tools in construction grinding concrete at Frank Messer and Sons Construction Company, Newport, KY (EPHB 24715c). National Institute for Occupational Safety and","cited_authors":"May","cited_year":"2002","cited_title":"NIOSH. 2002b","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743159,"raw_reference":"Health, Cincinnati, OH. January, 2002. NIOSH. 2002c. Pocket guide to chemical hazards. Pub. No. 2002-140. National Institute for Occupational Safety and Health, Cincinnati, OH.","cited_authors":"Health, Cincinnati, OH. January","cited_year":"2002","cited_title":"NIOSH. 2002c","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743160,"raw_reference":"OSHA. 1996. Ground-fault protection on construction sites. Occupational Safety and Health Administration, Office of Training and Education. May.","cited_authors":"OSHA","cited_year":"1996","cited_title":"Ground-fault protection on construction sites","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743161,"raw_reference":"EXPOSURES CONSTRUCTION Simcox, N., Lofgren, D., Leons, J. and J. Camp. 1999. Case Studies: Silica Exposure During Granite Countertop Fabrication. Appl. Occup. Environ Hygiene 14(9):577-582. Technical Notes Results for the period evaluated were 0.39, 0.78, and 1.2 mg/m3. If no additional exposure had occurred, the associated 8-hour time-weighted average (TWA) would have been 0.16, 0.31, and 0.34 mg/m3 for samples of 191 to 135 minutes duration. However, it is not uncommon for grinder operators to work at the same task for a full shift. Laboratories have not used particle counting for crystalline silica analysis for many years. Exposure data is now reported gravimetrically. However,","cited_authors":"EXPOSURES CONSTRUCTION Simcox, N., Lofgren, D., Leons, J. and J. Camp","cited_year":"1999","cited_title":"Case Studies: Silica Exposure During Granite Countertop Fabrication","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743162,"raw_reference":"Collingwood, S. and Heitbrink, W.A. 2007. Field evaluation of an engineering control for respirable crystalline silica exposures during mortar removal. J Occup Environ Hygiene 4:875-887.","cited_authors":"Collingwood, S. and Heitbrink, W.A","cited_year":"2007","cited_title":"Field evaluation of an engineering control for respirable crystalline silica exposures during mortar removal","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743163,"raw_reference":"Seixas, N.S. 2002. The effects of local exhaust ventilation controls on dust exposures during concrete cutting and grinding activities. Am Ind Hygiene Assoc J 63(4): 458-467.","cited_authors":"Seixas, N.S","cited_year":"2002","cited_title":"The effects of local exhaust ventilation controls on dust exposures during concrete cutting and grinding activities","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743164,"raw_reference":"Morgan, M. 2003. Silica dust exposures during selected construction activities. Am Ind Hygiene Assn J 64(3):319-28. May-June, 2003.","cited_authors":"Morgan, M","cited_year":"2003","cited_title":"Silica dust exposures during selected construction activities","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743165,"raw_reference":"Heitbrink, W.A. and Watkins, D.S. 2001. The effect of exhaust flow rate upon the respirable dust emissions for tuckpointing operations. In: In-Depth Study Report: Control Technology for Crystalline Silica Exposures in Construction. U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health. ECTB No. 247-18.","cited_authors":"Heitbrink, W.A. and Watkins, D.S","cited_year":"2001","cited_title":"The effect of exhaust flow rate upon the respirable dust emissions for tuckpointing operations","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743166,"raw_reference":"Beckett, W.S. 2007. A breathless builder. Breathe 3:386-390.","cited_authors":"Beckett, W.S","cited_year":"2007","cited_title":"A breathless builder","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743167,"raw_reference":"Nash, N.T. and Williams, D.R. 2000. Occupational exposure to crystalline silica during tuckpointing and the use of engineering controls. Appl Occup Environ Hygiene 15(1):8-10. January, 2000.","cited_authors":"Nash, N.T. and Williams, D.R","cited_year":"2000","cited_title":"Occupational exposure to crystalline silica during tuckpointing and the use of engineering controls","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743168,"raw_reference":"CONTROLLING SILICA NIOSH. 1996. Preventing silicosis and deaths in construction workers. Dept. of Health and Human","cited_authors":"CONTROLLING SILICA NIOSH","cited_year":"1996","cited_title":"Preventing silicosis and deaths in construction workers","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743169,"raw_reference":"NIOSH, 1998. Environmental surveillance report: Construction site #16, Covington, KY. National Institute for Occupational Safety and Health,","cited_authors":"NIOSH","cited_year":"1998","cited_title":"Environmental surveillance report: Construction site #16, Covington, KY. National Institute for Occupational Safety and Health","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743170,"raw_reference":"Morgantown, WV. June, 1998. NIOSH. 1999. Control technology and exposure assessment for occupational exposure to crystalline silica: Case 23―Masonry Tuckpointing (ECTB 233123c). National Institute for Occupational Safety and","cited_authors":"Morgantown, WV. June","cited_year":"1998","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743171,"raw_reference":"Health, Cincinnati, OH. NIOSH, 2000. In-depth survey report: Control technology for crystalline silica exposures in construction: Exposures and preliminary control evaluation at various sites for Bricklayers Local #9, Pittsburgh, Pennsylvania (ECTB 247-12). National Institute for Occupational Safety and Health, Cincinnati, OH.","cited_authors":"Health, Cincinnati, OH. NIOSH","cited_year":"2000","cited_title":"In-depth survey report: Control technology for crystalline silica exposures in construction: Exposures and preliminary control evaluation at various sites for Bricklayers Local #9, Pittsburgh, Pennsylvania (ECTB 247-12)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743172,"raw_reference":"February, 2000. NIOSH. 2002. Pocket guide to chemical hazards. Pub. No. 2002-140. National Institute for Occupational Safety and Health, Cincinnati, OH. June, 2002.","cited_authors":"February","cited_year":"2000","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743173,"raw_reference":"Shields, C. 1999. Silica dust exposures from OSHA construction inspections in the Chicago area 19961998. Occupational Safety and Health Administration. Aurora, IL, Area Office. Slide Presentation.","cited_authors":"Shields, C","cited_year":"1999","cited_title":"Silica dust exposures from OSHA construction inspections in the Chicago area 19961998","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743174,"raw_reference":"Zalk, D. 2002. Personal communication between D.","cited_authors":"Zalk, D","cited_year":"2002","cited_title":"Personal communication between D","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743175,"raw_reference":"Long, Eastern Research Group, Inc., Arlington, VA. October 29, 2002. Technical Notes These employees performed a variety of activities involving silica-containing materials, including abrasive blasting and work with fire brick (NIOSH, 1996). Laboratories have not used particle counting for crystalline silica analysis for many years. Exposure data is now reported gravimetrically. However,","cited_authors":"Long, Eastern Research Group, Inc., Arlington, VA. October 29","cited_year":"2002","cited_title":"Technical Notes These employees performed a variety of activities involving silica-containing materials, including abrasive blasting and work with fire brick (NIOSH, 1996)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743176,"raw_reference":"OSHA’s construction PEL for crystalline silica, established in 1971, is still listed as a particle-count value. (See Appendix E to OSHA’s National","cited_authors":"OSHA’s construction PEL for crystalline silica, established in","cited_year":"1971","cited_title":"is still listed as a particle-count value","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743177,"raw_reference":"ACGIH. 2001. Threshold limit values for chemical substances and physical agents and biological exposure indices. American Conference of Governmental Industrial Hygienists, Cincinnati, OH.","cited_authors":"ACGIH","cited_year":"2001","cited_title":"Threshold limit values for chemical substances and physical agents and biological exposure indices","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743178,"raw_reference":"Brouwer, D.H., Spee, T., Huijbers, R.F., Lurvink, M.W.M., Fritjers, A.C.P. 2004. Effectiveness of dust control by atomisation of water sprays on handheld demolition and soil compacting equipment. Tijdschrift voor toegepaste Arbowetenschap 4:68-74, 2004.","cited_authors":"Brouwer, D.H., Spee, T., Huijbers, R.F., Lurvink, M.W.M., Fritjers, A.C.P","cited_year":"2004","cited_title":"Effectiveness of dust control by atomisation of water sprays on handheld demolition and soil compacting equipment","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743179,"raw_reference":"Seixas, N.S. 2002. The effects of local exhaust ventilation controls on dust exposures during concrete cutting and grinding activities. Am Ind Hygiene Assoc. J 63(4): 458-467, 2002.","cited_authors":"Seixas, N.S","cited_year":"2002","cited_title":"The effects of local exhaust ventilation controls on dust exposures during concrete cutting and grinding activities","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743180,"raw_reference":"Echt, A., Sieber, K., Jones, E., Schill, D., Lefkowitz, D., Sugar, J., Hoffner, K. 2003. Control respirable dust and crystalline silica from breaking concrete with a jackhammer. Appl Occup Environ Hygiene 18(7): 491-495, 2003.","cited_authors":"Echt, A., Sieber, K., Jones, E., Schill, D., Lefkowitz, D., Sugar, J., Hoffner, K","cited_year":"2003","cited_title":"Control respirable dust and crystalline silica from breaking concrete with a jackhammer","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743181,"raw_reference":"Echt, A., Sieber, K., Williams, D., Cantrell, A., Schill, D.P., Lefkowitz, D., Sugar, J., Hoffner, K. 2004. Indepth survey report of a water spray device for suppressing respirable and crystalline silica dust from jackhammers at E.E. Cruz Co., South Plainfield, NJ.","cited_authors":"Echt, A., Sieber, K., Williams, D., Cantrell, A., Schill, D.P., Lefkowitz, D., Sugar, J., Hoffner, K","cited_year":"2004","cited_title":"Indepth survey report of a water spray device for suppressing respirable and crystalline silica dust from jackhammers at E.E. Cruz Co., South Plainfield, NJ","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743182,"raw_reference":"Camp, J. 2006. Silica exposure on construction sites: results of an exposure monitoring data compilation project. J Occup Environ Hygiene. 3(3):14452.","cited_authors":"Camp, J","cited_year":"2006","cited_title":"Silica exposure on construction sites: results of an exposure monitoring data compilation project","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743183,"raw_reference":"NIOSH. 1983. Health hazard evaluation report: Grand Gulf Nuclear Power Plant, Gibson, Mississippi. HETA 83-132-1508. U.S. Dept. of Health and Human Services, National Institute for Occupational Safety and Health.","cited_authors":"NIOSH","cited_year":"1983","cited_title":"Health hazard evaluation report: Grand Gulf Nuclear Power Plant, Gibson, Mississippi","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743184,"raw_reference":"EXPOSURES CONSTRUCTION NIOSH. 1996. Preventing silicosis and deaths in construction workers. U.S. Dept. of Health and Human Services, National Institute for Occupational Safety and Health, Publication No. 96-112.","cited_authors":"EXPOSURES CONSTRUCTION NIOSH","cited_year":"1996","cited_title":"Preventing silicosis and deaths in construction workers","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743185,"raw_reference":"NIOSH. 2002. Pocket guide to chemical hazards. Pub. No. 2002-140. National Institute for Occupational Safety and Health, Cincinnati, OH.","cited_authors":"NIOSH","cited_year":"2002","cited_title":"Pocket guide to chemical hazards","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743186,"raw_reference":"June, 2002. NIOSH. 2008. Water Spray Control of Hazardous Dust When Breaking Concrete with a Jackhammer.","cited_authors":"June","cited_year":"2002","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743187,"raw_reference":"May, 2008. http://www.cdc.gov/niosh/docs/wpsolutions/ 2008-127.","cited_authors":"May","cited_year":"2008","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":"http://www.cdc.gov/niosh/docs/wpsolutions/","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743188,"raw_reference":"OSHA. 1996. Ground-fault protection on construction sites. Occupational Safety and Health","cited_authors":"OSHA","cited_year":"1996","cited_title":"Ground-fault protection on construction sites","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743189,"raw_reference":"May, 1996. OSHA Case Files (Special Emphasis Program","cited_authors":"May","cited_year":"1996","cited_title":"OSHA Case Files (Special Emphasis Program","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743190,"raw_reference":"Inspection Reports, 1996-1998). Shields, C. 2000a. Database: Silica dust exposures associated with construction activities. Occupational Safety and Health Administration, North Aurora, IL. September 14, 2000. report exposure data gravimetrically. However,","cited_authors":"Inspection Reports","cited_year":"1996-1998","cited_title":"Shields, C. 2000a","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743191,"raw_reference":"OSHA’s construction PEL for crystalline silica, established in 1971, is still listed as a particle-count value. (See Appendix E to OSHA’s National Emphasis Program for Crystalline Silica, CPL 03-00007, for a detailed discussion of the conversion factor used to transform gravimetric measurements to particle-count values). In this guidance, OSHA is using 0.1 mg/m3 of respirable quartz as an 8-hour time-weighted average as a benchmark to describe the effectiveness of control measures. The benchmark is approximately equivalent to the general industry silica PEL. Other organizations suggest more stringent levels. For example, the National Institute for Occupational Safety and Health (NIOSH) recommends that respirable crystalline silica exposures be limited to 0.05 mg/m3 as a 10-hour timeweighted average (NIOSH, 2002). The American Conference of Governmental Industrial Hygienists (ACGIH) recommends that respirable crystalline silica exposures be limited to 0.025 mg/m3 as an 8hour time-weighted average (ACGIH, 2008). References: OSHA Case Files; Shields, 2000a [data of 3/29, 5/1, 5/11, 7/8, 8/13, and 10/1/99].","cited_authors":"OSHA’s construction PEL for crystalline silica, established in","cited_year":"1971","cited_title":"is still listed as a particle-count value","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743192,"raw_reference":"Shields, C. 2000b. Silica dust exposures from OSHA construction inspections in the Chicago area 19961999. Occupational Safety and Health","cited_authors":"Shields, C","cited_year":"2000b","cited_title":"Silica dust exposures from OSHA construction inspections in the Chicago area 19961999","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743193,"raw_reference":"Administration, Aurora, IL, Area Office Slide Presentation. WorkSafe Western Australia. 1996. Silica dust on construction sites. www.wt.com/au/safetyline/ d_pubs/silica.htm. March, accessed 04/15/97.","cited_authors":"Administration, Aurora, IL, Area Office Slide Presentation. WorkSafe Western Australia","cited_year":"1996","cited_title":"Silica dust on construction sites","cited_venue":null,"cited_doi":null,"cited_url":"www.wt.com/au/safetyline/","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743194,"raw_reference":"Zalk, D. 2000. Presentation at the American Industrial Hygiene Conference and Exposition,","cited_authors":"Zalk, D","cited_year":"2000","cited_title":"Presentation at the American Industrial Hygiene Conference and Exposition","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743195,"raw_reference":"Orlando, FL. May 24, 2000. Zalk, D. 2001. Personal communication between D.","cited_authors":"Orlando, FL. May 24","cited_year":"2000","cited_title":"Zalk, D. 2001","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743196,"raw_reference":"Arlington, VA. January 23, 2001. Zalk, D. 2002. Personal communication between D.","cited_authors":"Arlington, VA. January 23","cited_year":"2001","cited_title":"Zalk, D. 2002","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743197,"raw_reference":"Long, Eastern Research Group, Inc., Arlington, VA. October 29, 2002. Technical Notes Laboratories have not used particle counting for crystalline silica analysis in many years and now Copper tubing, heavy rubber, plastic tubing, and even hydraulic line have been used. The more flexible the tubing, the easier it is to adjust the nozzle position when installing the system. Under many conditions, 1/8 gallon per minute water flow will generate little run-off. Requirements, however, vary greatly by location. Contact the municipal environmental quality department or other appropriate authority to see if there are any local requirements.","cited_authors":"Long, Eastern Research Group, Inc., Arlington, VA. October 29","cited_year":"2002","cited_title":"Technical Notes Laboratories have not used particle counting for crystalline silica analysis in many years and now Copper tubing, heavy rubber, plastic tubing, and even hydraulic line have been used","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743198,"raw_reference":"OSHA Case Files; Shields, 2000a [data of 8/13]. Although visible dust cannot be used to predict the amount of respirable-sized dust in the air, if the spray is not controlling the visible dust, it is probably not controlling respirable dust either. Based on the limit of detection, the employee’s respirable silica exposure was calculated to be less than or equal to 0.037 mg/m3. All sample durations were 1 to 3 hours. This level is higher than typical on indoor construction sites, probably because the enclosed shed used in the test was smaller and had less natural ventilation than the indoor spaces evaluated for","cited_authors":null,"cited_year":null,"cited_title":"OSHA Case Files; Shields, 2000a [data of 8/13]. Although visible dust cannot be used to predict the amount of respirable-sized dust in the air, if the spray is not controlling the visible dust, it is probably not controlling respirable dust either","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743199,"raw_reference":"ACGIH. 2007. Industrial Ventilation, a Manual of Recommended Practice, 26th edition. American Conference of Governmental Industrial Hygienists,","cited_authors":"ACGIH","cited_year":"2007","cited_title":"Industrial Ventilation, a Manual of Recommended Practice, 26th edition","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743200,"raw_reference":"Cincinnati, OH, 2001. ACGIH. 2008. Threshold limit values for chemical substances and physical agents and biological exposure indices. American Conference of Governmental Industrial Hygienists, Cincinnati. OH, 2008.","cited_authors":"Cincinnati, OH","cited_year":"2001","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743201,"raw_reference":"CS UNITEC. 2003. Air Rotary Hammer Drill. http://www.csunitec.com/ rotary/airrotary.html. Accessed January 13, 2003.","cited_authors":"CS UNITEC","cited_year":"2003","cited_title":"Air Rotary Hammer Drill","cited_venue":null,"cited_doi":null,"cited_url":"http://www.csunitec.com/","ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743202,"raw_reference":"Hallin, N. 1983. Occurrence of quartz in the construction sector (Report 1983-04-01). Bygghälsan— The construction industry’s organization for working environment, safety and health. Stockholm, Sweden. April 1, 1983.","cited_authors":"Hallin, N","cited_year":"1983","cited_title":"Occurrence of quartz in the construction sector (Report 1983-04-01)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743203,"raw_reference":"Heitbrink, W.A. and D.S. Watkins. 2001. The effect of exhaust flow rate upon the respirable dust emissions for tuckpointing operations. In: In-Depth Study Report: Control Technology for Crystalline Silica Exposures in Construction. U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health. ECTB No. 247-18, 2001.","cited_authors":"Heitbrink, W.A. and D.S. Watkins","cited_year":"2001","cited_title":"The effect of exhaust flow rate upon the respirable dust emissions for tuckpointing operations","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743204,"raw_reference":"LBL. Undated. Asbestos management program, appendix G, Bulk sampling procedure. Lawrence Berkeley National Laboratory. Berkeley, CA.: http://www.lbl.gov/ehs/ih/forms/AsbesProg.doc. Accessed January 13, 2003.","cited_authors":"LBL. Undated. Asbestos management program, appendix G, Bulk sampling procedure. Lawrence Berkeley National Laboratory. Berkeley, CA.: http://www.lbl.gov/ehs/ih/forms/AsbesProg.doc. Accessed January 13","cited_year":"2003","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":"http://www.lbl.gov/ehs/ih/forms/AsbesProg.doc","ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743205,"raw_reference":"Lofgren, D.J. 1993. Silica exposure for concrete workers and masons. Appl. Occup. Environ. Hyg. 8(10):832-836, 1993.","cited_authors":"Lofgren, D.J","cited_year":"1993","cited_title":"Silica exposure for concrete workers and masons","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743206,"raw_reference":"NIOSH. 1996. Preventing silicosis and deaths in conCONTROLLING","cited_authors":"NIOSH","cited_year":"1996","cited_title":"Preventing silicosis and deaths in conCONTROLLING","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743207,"raw_reference":"NIOSH. 1999. Control technology and exposure assessment for occupational exposure to crystalline silica: Case 22 – rock drilling (ECTB 233-122c). National Institute for Occupational Safety and","cited_authors":"NIOSH","cited_year":"1999","cited_title":"Control technology and exposure assessment for occupational exposure to crystalline silica: Case 22 – rock drilling (ECTB 233-122c)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743208,"raw_reference":"Health, Cincinnati, OH. November 19, 1999.","cited_authors":"Health, Cincinnati, OH. November 19","cited_year":"1999","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743209,"raw_reference":"NIOSH. 2002. Pocket guide to chemical hazards. Pub. No. 2002-140. National Institute for Occupational Safety and Health, Cincinnati, OH. June.","cited_authors":"NIOSH","cited_year":"2002","cited_title":"Pocket guide to chemical hazards","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743210,"raw_reference":"Organiscak, J.A. and S.J. Page. 1996. Assessment of airborne dust generated from small truck-mounted rock drills. Report of Investigation No. 9616. U.S. Department of the Interior, Bureau of Mines,","cited_authors":"Organiscak, J.A. and S.J. Page","cited_year":"1996","cited_title":"Assessment of airborne dust generated from small truck-mounted rock drills","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743211,"raw_reference":"Pittsburgh, PA. OSHA Case Files (Special Emphasis Program Inspection Reports from 1996-1998).","cited_authors":"Pittsburgh, PA. OSHA Case Files (Special Emphasis Program Inspection Reports from","cited_year":"1996-1998","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743212,"raw_reference":"Sam, K. 2000. Control measures for reducing employee exposure to concentrations of total and respirable silica in the ready-mix concrete industry during drum cleaning. Presentation at American Industrial Hygiene Conference & Exposition.","cited_authors":"Sam, K","cited_year":"2000","cited_title":"Control measures for reducing employee exposure to concentrations of total and respirable silica in the ready-mix concrete industry during drum cleaning","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743213,"raw_reference":"Orlando, FL. May 24, 2000. Shepherd, S., Woskie, S.R., Holcroft, C. and","cited_authors":"Orlando, FL. May 24","cited_year":"2000","cited_title":"Shepherd, S., Woskie, S.R., Holcroft, C. and","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743214,"raw_reference":"Ellenbecker, M. 2009. Reducing Silica and Dust Exposures in Construction During Use of Powered Concrete-Cutting Hand Tools: Efficacy of Local Exhaust Ventilation on Hammer Drills. Journal of Occupational and Environmental Hygiene, 6:1,42-51, 2009. U.S. GSA. 2001. Standard operating procedure for asbestos operations and maintenance activities. Appendix B: Cleaning above a drop ceiling--minicontainment methods. U.S. General Services","cited_authors":"Ellenbecker, M","cited_year":"2009","cited_title":"Reducing Silica and Dust Exposures in Construction During Use of Powered Concrete-Cutting Hand Tools: Efficacy of Local Exhaust Ventilation on Hammer Drills","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743215,"raw_reference":"Administration, Kansas City, MO. July. http://safety. gsa.gov/gsa/heartland/sops/acm_sop.pdf. Accessed January 13, 2003.","cited_authors":"Administration, Kansas City, MO. July. http://safety. gsa.gov/gsa/heartland/sops/acm_sop.pdf. Accessed January 13","cited_year":"2003","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":"http://safety","ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743216,"raw_reference":"Woods, David T. 2000. A common sense approach to disturbing asbestos. Ind. Safety & Hyg. News Online. www.ishn.com/CDA/ArticleInformation/features/BNP___Features___Item/0,2162,2572,00.html. Accessed January 15, 2003.","cited_authors":"Woods, David T","cited_year":"2000","cited_title":"A common sense approach to disturbing asbestos","cited_venue":null,"cited_doi":null,"cited_url":"www.ishn.com/CDA/ArticleInformation/features/BNP___Features___Item/0,2162,2572,00.html","ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743217,"raw_reference":"Zalk, D. 2000. Presentation at American Industrial Hygiene Conference & Exposition. Orlando, FL. May 24, 2000.","cited_authors":"Zalk, D","cited_year":"2000","cited_title":"Presentation at American Industrial Hygiene Conference & Exposition","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743218,"raw_reference":"Long, Eastern Research Group, Inc., Arlington, VA. October 29, 2002.","cited_authors":"Long, Eastern Research Group, Inc., Arlington, VA. October 29","cited_year":"2002","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743219,"raw_reference":"EXPOSURES CONSTRUCTION Technical Notes The three respirable crystalline silica results cited are 0.3, 0.26, and 0.11 mg/m3, collected as 457-, 110and 177-minute samples, respectively (Lofgren, 1993). Laboratories have not used particle counting for crystalline silica analysis in many years and now report exposure data gravimetrically. However,","cited_authors":"EXPOSURES CONSTRUCTION Technical Notes The three respirable crystalline silica results cited are 0.3, 0.26, and 0.11 mg/m3, collected as 457-, 110and 177-minute samples, respectively (Lofgren","cited_year":"1993","cited_title":"Laboratories have not used particle counting for crystalline silica analysis in many years and now report exposure data gravimetrically","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743220,"raw_reference":"OSHA’s general industry permissible exposure limit (PEL).1 Furthermore, the U.S. Bureau of Mines found that respirable silica concentrations averaged 2.13 mg/m3 in the immediate vicinity of small surface drilling operations (U.S. Bureau of Mines, 1995). Concentrations of respirable silica in soil and rock may vary widely depending on the type of underlying rock formation and history of volcanic eruptions. For example, the preliminary site investigation of the Department of Energy’s Yucca Mountain site indicated that soil concentrations of cristobalite (a form of silica) ranged from 18 to 28 percent, and many job tasks were associated with overexposure (CRWMS 1999). If a construction company will be doing substantial excavation at a site, then obtaining a profile of the silica content of soil and rock from bulk samples of the projected excavation represents good industrial hygiene practice. Many times this information can be obtained as part of the project design and provided to the contractor","cited_authors":"OSHA’s general industry permissible exposure limit (PEL).1 Furthermore, the U.S. Bureau of Mines found that respirable silica concentrations averaged 2.13 mg/m3 in the immediate vicinity of small surface drilling operations (U.S. Bureau of Mines","cited_year":"1995","cited_title":"Concentrations of respirable silica in soil and rock may vary widely depending on the type of underlying rock formation and history of volcanic eruptions","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743221,"raw_reference":"CONTROLLING SILICA Earth drilling rigs operated without dust controls are capable of producing very high respirable silica levels (Photo courtesy of NIOSH, 1992.) Silica Dust Control Measures Dust Collection Systems Various types of dust collection systems are available for earth drills. Commonly used equipment incorporates a movable suction duct attached to a shroud (a flexible rubber skirt) that encloses the drill hole opening and captures the cuttings coming through the hole. Drilling equipment that does not include these controls can be retrofitted by the manufacturer or a mechanical shop. Dusty air pulled from the shroud enclosure usually passes through a flexible duct leading to a primary dust separator and a secondary filter system. The dust separator often includes a self-cleaning “back-pulse” feature that discharges the collected particles to the ground. Some secondary filter systems are also self-cleaning. Finally, the exhaust air is discharged to the atmosphere. Design Considerations Dust collection systems are commercially available and work well in all climates and with all drill types. If the systems are well designed, dust collectors offer substantial dust reduction. Some important design factors are described below. Drill Bit Shroud Design. Conventional shrouds are rectangular and constructed of four separate","cited_authors":"CONTROLLING SILICA Earth drilling rigs operated without dust controls are capable of producing very high respirable silica levels (Photo courtesy of NIOSH","cited_year":"1992","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743222,"raw_reference":"ACGIH. 2001. Industrial Ventilation, A Manual of Recommended Practice. 24th Edition. American Conference of Governmental Industrial Hygienists.","cited_authors":"ACGIH","cited_year":"2001","cited_title":"Industrial Ventilation, A Manual of Recommended Practice","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743223,"raw_reference":"Cincinnati, OH, 2001. ACGIH. 2008. Threshold limit values for chemical substances and physical agents and biological exposure indices. American Conference of Governmental Industrial Hygienists, Cincinnati, OH, 2008.","cited_authors":"Cincinnati, OH","cited_year":"2001","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743224,"raw_reference":"CRWMS. 1999. Engineering File – Subsurface Repository. Civilian Radioactive Waste Management System Management & Operating Contractor. BCA000000-01717-5705-00005 Rev 02, DCN 01. June, 1999.","cited_authors":"CRWMS","cited_year":"1999","cited_title":"Engineering File – Subsurface Repository","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743225,"raw_reference":"ERG. 2003. Technological Feasibility Study and Cost Impact Analysis of the Draft Crystalline Silica Standard for Construction. Table 2, Ranking of dust control technology, ERG composite of available research on control technology. February, 2003.","cited_authors":"ERG","cited_year":"2003","cited_title":"Technological Feasibility Study and Cost Impact Analysis of the Draft Crystalline Silica Standard for Construction","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743226,"raw_reference":"NIOSH ALERT, 1992a. Preventing Silicosis and Deaths in Rock Drillers. No. 92-107.","cited_authors":"NIOSH ALERT","cited_year":"1992a","cited_title":"Preventing Silicosis and Deaths in Rock Drillers","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743227,"raw_reference":"NIOSH. 1992b. Environmental surveillance report: Breckinridge Construction Drilling, Westover, WV. National Institute for Occupational Safety and","cited_authors":"NIOSH","cited_year":"1992b","cited_title":"Environmental surveillance report: Breckinridge Construction Drilling, Westover, WV. National Institute for Occupational Safety and","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743228,"raw_reference":"Morgantown, WV, 1992. EXPOSURES CONSTRUCTION","cited_authors":"Morgantown, WV","cited_year":"1992","cited_title":"EXPOSURES CONSTRUCTION","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743229,"raw_reference":"NIOSH. 1997. Silica…it’s not just dust – What rockdrillers can do to protect their lungs from silica dust. U.S. Dept. of Health and Human Services (National Institute for Occupational Safety and Health, Publication No. 97-118), available at <http://www. cdc. gov/niosh/rock.html>. Accessed November 22, 2002.","cited_authors":"NIOSH","cited_year":"1997","cited_title":"Silica…it’s not just dust – What rockdrillers can do to protect their lungs from silica dust","cited_venue":null,"cited_doi":null,"cited_url":"http://www","ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743230,"raw_reference":"NIOSH. 1998. New shroud design controls silica dust for surface mine and construction blast-hole drills. U.S. Dept. of Health and Human Services (National Institute for Occupational Safety and","cited_authors":"NIOSH","cited_year":"1998","cited_title":"New shroud design controls silica dust for surface mine and construction blast-hole drills","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743231,"raw_reference":"Health, Publication No. 98-150), 1998. NIOSH. 2002. Pocket guide to chemical hazards. Pub. No. 2002-140. National Institute for Occupational Safety and Health, Cincinnati, OH.","cited_authors":"Health, Publication No. 98-150)","cited_year":"1998","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743232,"raw_reference":"June, 2002. Organiscak, J.A. 2002. Personal communication between J. Organiscak, National Institute for Occupational Safety and Health, Pittsburgh, PA, and W. Long of Eastern Research Group, Inc. November 21, 2002.","cited_authors":"June","cited_year":"2002","cited_title":"Organiscak, J.A. 2002","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743233,"raw_reference":"Organiscak, J.A. and S.J. Page. 1996. Assessment of airborne dust generated from small truck-mounted rock drills. Report of investigation No. 9616. U.S. Department of the Interior, Bureau of Mines,","cited_authors":"Organiscak, J.A. and S.J. Page","cited_year":"1996","cited_title":"Assessment of airborne dust generated from small truck-mounted rock drills","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743234,"raw_reference":"Pittsburgh, PA, 1996. OSHA Case Files (Special Emphasis Program Inspection Reports from 1996-1998). (See Appendix E to OSHA’s National Emphasis Program for Crystalline Silica, CPL 03-00-007, for a detailed discussion of the conversion factor used to transform gravimetric measurements to particlecount values). In this guidance, OSHA is using 0.1 mg/m3 of respirable quartz as an 8-hour timeweighted average as a benchmark to describe the effectiveness of control measures. The benchmark is approximately equivalent to the general industry silica PEL. Other organizations suggest more stringent levels. For example, the National Institute for Occupational Safety and Health (NIOSH) recommends that respirable crystalline silica exposures be limited to 0.05 mg/m3 as a 10-hour time-weighted average (NIOSH, 2002). The American Conference of Governmental Industrial Hygienists (ACGIH) recommends that respirable crystalline silica exposures be limited to 0.025 mg/m3 as an 8-hour time-weighted average (ACGIH, 2008). To avoid clogging, ACGIH (2001) recommends 3,500 to 4,000 feet per minute (FPM) minimum air velocity through ducts carrying rock or concrete dust. Use a higher velocity of at least 4,500 FPM if dust is moist or contains small chips. Bit size, hole depth, substrate and weather all affect the amount of water needed to control dust. The usage rate must be adjusted for each individual operation, but typically will be about ½ to 1 gallon per minute.","cited_authors":"Pittsburgh, PA","cited_year":"1996","cited_title":"OSHA Case Files (Special Emphasis Program Inspection Reports from 1996-1998)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743235,"raw_reference":"Page, S.J. 1991. Respirable dust control on overburdened drills at surface mines. American Mining","cited_authors":"Page, S.J","cited_year":"1991","cited_title":"Respirable dust control on overburdened drills at surface mines","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743236,"raw_reference":"Congress, Coal Convention. June 5, 1991. Page, S.J. and J.A. Organiscak. 1995. Taming the dust devil: an evaluation of improved dust controls for surface drills using Rotoclone collectors. Engineering and Mining Journal, pp. ww30 – ww31.","cited_authors":"Congress, Coal Convention. June 5","cited_year":"1991","cited_title":"Page, S.J. and J.A. Organiscak","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743237,"raw_reference":"November, 1995. U.S. Bureau of Mines. 1995. Dust collector discharge shroud reduces dust exposure to drill operators at surface coal mines. Technology News. No. 447.","cited_authors":"November","cited_year":"1995","cited_title":"U.S. Bureau of Mines","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743238,"raw_reference":"March, 1995. Zimmmer, A.T. 1997. Comparative evalution of dust control technologies on percussion rock-drilling rigs. Appl. Occup. Environ. Hyg. 12(12): 782-788.","cited_authors":"March","cited_year":"1995","cited_title":"Zimmmer, A.T. 1997","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743239,"raw_reference":"December, 1997. Certain drill systems use large quantities of water, rather than air, to flush cuttings from the hole. The large volume of water in the hole usually controls dust completely and additional devices, such as dust collectors, offer very little extra benefit. High air velocity and turbulence in the flexible duct atomize the water drops to create a mist, which captures dust as it moves down the length of the duct (Organiscak, 2002). To measure water flow rate, adjust the flow as desired, then check how long it takes to fill a onegallon milk container. To better exclude dust, pressurize the cab interior by using a pressurization unit to introduce filtered outside air into the cab. Studies show that 100 cubic feet per minute (CFM) provides adequate pressure (0.2 inches of water gauge) to keep dust from leaking into a well-sealed 100 cubic foot cab. Bulk samples indicated the granite contained 30 to 40 percent crystalline silica. Technical Notes Laboratories have not used particle counting for crystalline silica analysis in many years and now report exposure data gravimetrically. However,","cited_authors":"December","cited_year":"1997","cited_title":"Certain drill systems use large quantities of water, rather than air, to flush cuttings from the hole","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743240,"raw_reference":"Nonetheless, drywall joint compounds may contain varying amounts of silica and drywall finishing employees can be overexposed in certain circumstances. For example, by using a joint compound containing just 3 percent silica, an employee could exceed the Occupational Safety and Health Administration’s (OSHA) benchmark of 0.1 mg/m³ (milligrams of silica per cubic meter of air) as an 8-hour time-weighted average (TWA), an exposure approximately equivalent to OSHA’s general industry permissible exposure limit (PEL), during intensive periods of uncontrolled drywall sanding on ceilings. One study of drywall sanding, in which a silica-containing joint compound was used, found that the respirable silica level exceeded 0.15 mg/m³ (NIOSH, 1997).1,2 The potential for silica exposure is also indicated by the results of NIOSH tests of settled drywall dust.","cited_authors":"Nonetheless, drywall joint compounds may contain varying amounts of silica and drywall finishing employees can be overexposed in certain circumstances. For example, by using a joint compound containing just 3 percent silica, an employee could exceed the Occupational Safety and Health Administration’s (OSHA) benchmark of 0.1 mg/m³ (milligrams of silica per cubic meter of air) as an 8-hour time-weighted average (TWA), an exposure approximately equivalent to OSHA’s general industry permissible exposure limit (PEL), during intensive periods of uncontrolled drywall sanding on ceilings. One study of drywall sanding, in which a silica-containing joint compound was used, found that the respirable silica level exceeded 0.15 mg/m³ (NIOSH","cited_year":"1997","cited_title":"1,2 The potential for silica exposure is also indicated by the results of NIOSH tests of settled drywall dust","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743241,"raw_reference":"NIOSH found that dust generated during drywall sanding contained up to 6 percent silica (NIOSH, 1995). Other studies found that silica constituted up to 3.7 percent of the airborne respirable dust collected in drywall sanding employees’ breathing zones (NIOSH, 1997; Epling et al., 1999).3 Drywall sanding employees can also experience total dust exposures substantially above OSHA limits. In one study, employees using hand sanders without controls had exposures up to 143.1 mg/m³ of total dust. Similarly, employees using conventional pole-mounted sanders were exposed to up to 35.1 mg/m³ of total dust (CPWR, 1998).4 Although both of these exposures exceed regulatory limits, these results demonstrate that pole sander use can reduce dust exposures by increasing the distance between the employee and the point of work. An earlier NIOSH study also found lower exposures for employees using pole-mounted drywall sanders compared to handheld sanding (NIOSH, 1995).","cited_authors":"NIOSH found that dust generated during drywall sanding contained up to 6 percent silica (NIOSH","cited_year":"1995","cited_title":"Other studies found that silica constituted up to 3.7 percent of the airborne respirable dust collected in drywall sanding employees’ breathing zones (NIOSH, 1997; Epling et al., 1999).3 Drywall sanding employees can also experience total dust exposures substantially above OSHA limits","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743242,"raw_reference":"Additionally, NIOSH (1997) found that some of the highest dust exposures occur when employees sand joint compound in enclosed spaces, such as closets or small rooms. Poor air exchange in these areas causes dust levels to build up when dust controls are not used. Increasing or decreasing dust dissipation (by increasing distance to the employee or decreasing air exchange) affects respirable dust levels as well as total dust levels. For example, concrete finishers using a long-angled jig to grind a ceiling had lower","cited_authors":"Additionally, NIOSH","cited_year":"1997","cited_title":"found that some of the highest dust exposures occur when employees sand joint compound in enclosed spaces, such as closets or small rooms","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743243,"raw_reference":"EXPOSURES CONSTRUCTION silica exposures than employees grinding concrete with equipment attached to a short section of pipe and held directly overhead (OSHA Case Files). Employees grinding concrete indoors had higher respirable silica exposures than employees performing the same task outdoors, where dust could dissipate more quickly (Lofgren, 1993; NIOSH, 2001;","cited_authors":null,"cited_year":null,"cited_title":"EXPOSURES CONSTRUCTION silica exposures than employees grinding concrete with equipment attached to a short section of pipe and held directly overhead (OSHA Case Files)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743244,"raw_reference":"OSHA Case Files). percent when used during pole sanding and 95 percent for hand sanding. Both of the resulting exposure levels were well below regulatory limits for total dust (CPWR, 1998). Figure 1 shows the average reduction in airborne dust measured for four drywall sanding operations—pole-mounted sanding and hand sanding with and without vacuum dust control measures from the CPWR study.6 Silica-Free Joint Compounds Many manufacturers offer joint compounds that contain little or no silica. In a study of six brands of joint compound purchased at retail stores, no crystalline silica was detected in three brands (NIOSH, 1997). The silica present in a sample of one of the six products, however, was substantially different from the percentage listed on the material safety data sheet (MSDS) for that product.5 Nonetheless,","cited_authors":"OSHA Case Files). percent when used during pole sanding and 95 percent for hand sanding. Both of the resulting exposure levels were well below regulatory limits for total dust (CPWR","cited_year":"1998","cited_title":"Figure 1 shows the average reduction in airborne dust measured for four drywall sanding operations—pole-mounted sanding and hand sanding with and without vacuum dust control measures from the CPWR study.6 Silica-Free Joint Compounds Many manufacturers offer joint compounds that contain little or no silica","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743245,"raw_reference":"OSHA recommends that employers rely on manufacturers’ information and use proper methods to minimize employees’ dust exposures, rather than testing joint compounds themselves. Regardless of a compound’s silica content, the high levels of dust that drywall finishing may generate also poses a health hazard. Thus, OSHA recommends that employees always use dust control measures when drywall sanding. The two principal methods for controlling dust are (1) vacuum dust collection systems and (2) wet sponging. Either method is easy to implement. Silica-Free Joint Compounds • Check the label and the MSDS to identify the product’s ingredients (usually listed in Section 3 on the MSDS). • Avoid using joint compounds that contain crystalline silica or quartz (another common term for crystalline silica). • Always use dust control methods, regardless of the joint compound’s silica content. Vacuum Dust Collection Systems Vacuum dust collection (VDC) systems for drywall sanding equipment are commercially available, and studies show that they significantly reduce total dust concentrations. A NIOSH study of the effectiveness of several vacuum dust collection systems showed reductions in total dust exposures ranging from 80 to 97 percent, depending on the system used (NIOSH, 1995).","cited_authors":"OSHA recommends that employers rely on manufacturers’ information and use proper methods to minimize employees’ dust exposures, rather than testing joint compounds themselves. Regardless of a compound’s silica content, the high levels of dust that drywall finishing may generate also poses a health hazard. Thus, OSHA recommends that employees always use dust control measures when drywall sanding. The two principal methods for controlling dust are (1) vacuum dust collection systems and (2) wet sponging. Either method is easy to implement. Silica-Free Joint Compounds • Check the label and the MSDS to identify the product’s ingredients (usually listed in Section 3 on the MSDS). • Avoid using joint compounds that contain crystalline silica or quartz (another common term for crystalline silica). • Always use dust control methods, regardless of the joint compound’s silica content. Vacuum Dust Collection Systems Vacuum dust collection (VDC) systems for drywall sanding equipment are commercially available, and studies show that they significantly reduce total dust concentrations. A NIOSH study of the effectiveness of several vacuum dust collection systems showed reductions in total dust exposures ranging from 80 to 97 percent, depending on the system used (NIOSH","cited_year":"1995","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743246,"raw_reference":"ACGIH. 2001. Threshold limit values for chemical substances and physical agents and biological exposure indices. American Conference of Governmental Industrial Hygienists, Cincinnati, OH. Center to Protect Workers’ Rights (CPWR). 1998. Drywall Dust Engineering Controls. Video VI-98. Produced jointly with National Institute for Occupational Safety and Health (NIOSH) Engineering and Work Practices Controls Work Group.","cited_authors":"ACGIH","cited_year":"2001","cited_title":"Threshold limit values for chemical substances and physical agents and biological exposure indices","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743247,"raw_reference":"Epling, C., Gitelman, A., Desai, T. and J. Dement. 1999. Airborne exposures and ambulatory peak expiratory flow in drywall finishers. Report OSH298. Center to Protect Workers’ Rights.","cited_authors":"Epling, C., Gitelman, A., Desai, T. and J. Dement","cited_year":"1999","cited_title":"Airborne exposures and ambulatory peak expiratory flow in drywall finishers","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743248,"raw_reference":"Lofgren, D.J. 1993. Case studies: Silica exposure for concrete workers and masons. Appl. Occup. Environ. Hyg. 8(10):832-836. October, 1993.","cited_authors":"Lofgren, D.J","cited_year":"1993","cited_title":"Case studies: Silica exposure for concrete workers and masons","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743249,"raw_reference":"Murray J. and Nadel J., Editors. Textbook of Respiratory Medicine, 2nd Ed., 1994, Airway","cited_authors":"Murray J. and Nadel J., Editors. Textbook of Respiratory Medicine, 2nd Ed","cited_year":"1994","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743250,"raw_reference":"Pharmacology, pp. 285-311. NIOSH. 1984. Health Hazard Evaluation Report. Grand Gulf Nuclear Power Plant, Port Gibson, MI. Dept. of Health and Human Services (HETA 83-1321508). Cincinnati, OH.","cited_authors":"Pharmacology, pp. 285-311. NIOSH","cited_year":"1984","cited_title":"Health Hazard Evaluation Report","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743251,"raw_reference":"NIOSH. 1995. In-depth survey report: a laboratory comparison of conventional drywall sanding techniques versus commercially available control. ECTB 208-11a. National Institute for Occupational Safety and Health.","cited_authors":"NIOSH","cited_year":"1995","cited_title":"In-depth survey report: a laboratory comparison of conventional drywall sanding techniques versus commercially available control","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743252,"raw_reference":"NIOSH. 1997. Health Hazard Evaluation Report. Center to Protect Workers’ Rights. Washington, DC, Dept. of Health and Human Services Report (HETA94-0078-2660). Cincinnati, OH.","cited_authors":"NIOSH","cited_year":"1997","cited_title":"Health Hazard Evaluation Report","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743253,"raw_reference":"NIOSH 2001. In-depth survey report for four sites: exposure to silica from hand tools in construction chipping, grinding, and hand demolition at Frank Messer and Sons Construction Company, Lexington and Newport, KY, and Columbus and Springfield, OH (EPHB 247-15). National Institute for Occupational Safety and Health, Cincinnati, OH. April, 2001. Occupational Safety and Health Administration Occupational Safety and Health (NIOSH) recommends that respirable crystalline silica exposures be limited to 0.05 mg/m3 as a 10-hour time-weighted average (NIOSH, 2002). The American Conference of Governmental Industrial Hygienists (ACGIH) recommends that respirable crystalline silica exposures be limited to 0.025 mg/m3 as an 8-hour time-weighted average (ACGIH, 2008).","cited_authors":"NIOSH","cited_year":"2001","cited_title":"In-depth survey report for four sites: exposure to silica from hand tools in construction chipping, grinding, and hand demolition at Frank Messer and Sons Construction Company, Lexington and Newport, KY, and Columbus and Springfield, OH (EPHB 247-15)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743254,"raw_reference":"June, 2002. OSHA Case Files (Special Emphasis Program Inspection Reports from 1996-1998).","cited_authors":"June","cited_year":"2002","cited_title":"OSHA Case Files (Special Emphasis Program Inspection Reports from 1996-1998)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743255,"raw_reference":"USG. 2002. Finishing and Decorating Gypsum Panels/Wet Sanding. J-610/12-87. http://www.usg.com. (Accessed November 16, 2002.) A 382-minute sample resulted in a respirable dust exposure level of 7.0 mg/m3 and a silica level concentration of 0.21 mg/m3.","cited_authors":"USG","cited_year":"2002","cited_title":"Finishing and Decorating Gypsum Panels/Wet Sanding","cited_venue":null,"cited_doi":null,"cited_url":"http://www.usg.com","ref_kind":"dataset","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743256,"raw_reference":"Epling (1999) collected 8-hour respirable crystalline silica samples at two construction sites using a 10millimeter cyclone at 2.6 liters/minute (LPM) airflow to achieve a 4-micrometer cut-point. Crystalline silica was quantifiable at 1.1 to 3.7 percent in four of the six samples.","cited_authors":"Epling","cited_year":"1999","cited_title":"collected 8-hour respirable crystalline silica samples at two construction sites using a 10millimeter cyclone at 2.6 liters/minute (LPM) airflow to achieve a 4-micrometer cut-point","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743257,"raw_reference":"NIOSH (1997) used Dorr-Oliver cyclones at 1.7 LPM to collect 22 samples, of which 15 (68 percent) contained silica amounts between the level of quantification (LOQ) and limit of detection (LOD). In the same report, NIOSH described two additional respirable crystalline silica results from another site as 0.04 and 0.08 mg/m3 for samples of 443 and 435 minutes duration.","cited_authors":"NIOSH","cited_year":"1997","cited_title":"used Dorr-Oliver cyclones at 1.7 LPM to collect 22 samples, of which 15 (68 percent) contained silica amounts between the level of quantification (LOQ) and limit of detection (LOD)","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743258,"raw_reference":"Young-Corbett, D.E. and Nussbaum, M.A. (2009). Dust Control Effectiveness of Drywall Sanding Tools. Journal of Occupational and Environmental","cited_authors":"Young-Corbett, D.E. and Nussbaum, M.A","cited_year":"2009","cited_title":"Dust Control Effectiveness of Drywall Sanding Tools","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743259,"raw_reference":"OSHA’s construction PEL for crystalline silica, established in 1971, is still listed as a particle-count value. (See Appendix E to OSHA’s National Emphasis Program for Crystalline Silica, CPL 03-00-007, for a detailed discussion of the conversion factor used to transform gravimetric measurements to particlecount values). In this guidance, OSHA is using 0.1 mg/m3 of respirable quartz as an 8-hour timeweighted average as a benchmark to describe the effectiveness of control measures. The benchmark is approximately equivalent to the general industry silica PEL. Other organizations suggest more stringent levels. For example, the National Institute for","cited_authors":"OSHA’s construction PEL for crystalline silica, established in","cited_year":"1971","cited_title":"is still listed as a particle-count value","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743260,"raw_reference":"CONTROLLING SILICA These values were those reported in the CPWR video, which may not have shown all measurements taken during the study. Respirable dust levels were not reported (CPWR, 1998). When the silica percentage is in doubt, some laboratories that specialize in environmental testing can analyze a sample of the product to determine the actual silica content. OSHA recommends, however, that employers minimize employee exposure by relying on manufacturers’ information and using dust control methods rather than by testing joint compounds themselves. Data values were averaged from those presented in the CPWR video, which may not include all values measured during the actual study.","cited_authors":"CONTROLLING SILICA These values were those reported in the CPWR video, which may not have shown all measurements taken during the study. Respirable dust levels were not reported (CPWR","cited_year":"1998","cited_title":"When the silica percentage is in doubt, some laboratories that specialize in environmental testing can analyze a sample of the product to determine the actual silica content","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743261,"raw_reference":"ACGIH. 2001. Industrial Ventilation, a Manual of Recommended Practice, 25th edition. American Conference of Governmental Industrial Hygienists,","cited_authors":"ACGIH","cited_year":"2001","cited_title":"Industrial Ventilation, a Manual of Recommended Practice, 25th edition","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743262,"raw_reference":"Addo, J.Q. and Sanders, T.J. 1995. Effectiveness and environmental impact of road dust suppressants. Mountain-Plains Consortium Report No. 95-28A.","cited_authors":"Addo, J.Q. and Sanders, T.J","cited_year":"1995","cited_title":"Effectiveness and environmental impact of road dust suppressants","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743263,"raw_reference":"Beardwood, J. 2001. Dust gets in your eyes…lungs, wallet, and other wear parts. Grading and Excavation Contractor. www.forester.net/gx_0106_ dust.html. Bureau of Mines. 1985. Adding steam to control dust in mineral processing. Report of Investigation No. 8935, 1985.","cited_authors":"Beardwood, J","cited_year":"2001","cited_title":"Dust gets in your eyes…lungs, wallet, and other wear parts","cited_venue":null,"cited_doi":null,"cited_url":"www.forester.net/gx_0106_","ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743264,"raw_reference":"Drenner, J., and T. Trumbull. 2003. Preliminary report on used fryer oil as a dust suppressant. P² Highlight. (January) www.iwrc/org/p2highlt/p2current.cfm.","cited_authors":"Drenner, J., and T. Trumbull","cited_year":"2003","cited_title":"Preliminary report on used fryer oil as a dust suppressant","cited_venue":null,"cited_doi":null,"cited_url":"www.iwrc/org/p2highlt/p2current.cfm","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743265,"raw_reference":"Echt, A., and W.K. Sieber. 2002. Case Studies: Control of silica exposure from hand tools in construction: Grinding concrete. Appl. Occup. Environ. Hygiene. 17(7):457-461. July, 2002.","cited_authors":"Echt, A., and W.K. Sieber","cited_year":"2002","cited_title":"Case Studies: Control of silica exposure from hand tools in construction: Grinding concrete","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743266,"raw_reference":"Flanagan, M.E., N. Seixas, M. Majar, J. Camp, and M. Morgan. 2003. Silica dust exposures during selected construction activities. Am. Ind. Hygiene Assn. J 64(3):319-28. May-June, 2003.","cited_authors":"Flanagan, M.E., N. Seixas, M. Majar, J. Camp, and M. Morgan","cited_year":"2003","cited_title":"Silica dust exposures during selected construction activities","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743267,"raw_reference":"Grenier, M.G. and Bigu, J. 1988. Suppression of airborne dust in hard rock mines by means of electrostatic water sprays. Appl. Ind. Hygiene. 3:251-257.","cited_authors":"Grenier, M.G. and Bigu, J","cited_year":"1988","cited_title":"Suppression of airborne dust in hard rock mines by means of electrostatic water sprays","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743268,"raw_reference":"September, 1988. Heckel, C.L., A. Quraishi, N.G. Carlson, and A.J.","cited_authors":"September","cited_year":"1988","cited_title":"Heckel, C.L., A. Quraishi, N.G. Carlson, and A.J","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743269,"raw_reference":"Streifel. 2000. Evaluation of vacuum cleaners: A method to evaluate the cleaning effectiveness and airborne particle generation of vacuum cleaners. Poster presented at 2000 American Industrial Hygiene Conference and Exposition.","cited_authors":"Streifel","cited_year":"2000","cited_title":"Evaluation of vacuum cleaners: A method to evaluate the cleaning effectiveness and airborne particle generation of vacuum cleaners","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743270,"raw_reference":"Hogan, T.J. 1996. Selected particulates: silica. In","cited_authors":"Hogan, T.J","cited_year":"1996","cited_title":"Selected particulates: silica","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743271,"raw_reference":"Plog, B.A., J. Niland, and P.J. Quinlan, eds. Fundamentals of Industrial Hygiene, 4th ed. National Safety Council. Itasca, IL, pp. 180-182, 1996.","cited_authors":"Plog, B.A., J. Niland, and P.J. Quinlan, eds. Fundamentals of Industrial Hygiene, 4th ed. National Safety Council. Itasca, IL, pp. 180-182","cited_year":"1996","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743272,"raw_reference":"Johnston, A.M., J.H. Vincent, and A.D. Jones. 1985. Measurement of electric charge for workplace aerosols. Ann. Occup. Hygiene. 29:2, 1985.","cited_authors":"Johnston, A.M., J.H. Vincent, and A.D. Jones","cited_year":"1985","cited_title":"Measurement of electric charge for workplace aerosols","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743273,"raw_reference":"McKernan, J. 2000. Personal communication between J. McKernan of National Institute for Occupational Safety and Health and L. Lewis of Eastern Research Group, January 28, 2000.","cited_authors":"McKernan, J","cited_year":"2000","cited_title":"Personal communication between J. McKernan of National Institute for Occupational Safety and Health and L. Lewis of Eastern Research Group, January 28, 2000","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743274,"raw_reference":"NIOSH. 1998. Evaluation of substitute materials for silica sand in abrasive blasting. Report prepared under contract 200-95-2946. National Institute for Occupational Safety and Health. Pittsburgh, PA.","cited_authors":"NIOSH","cited_year":"1998","cited_title":"Evaluation of substitute materials for silica sand in abrasive blasting","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743275,"raw_reference":"September, 1998. NIOSH. 1999a. Control technology and exposure assessment for occupational exposure to crystalline silica: case 04 -- a concrete finishing operation. Report # ECTB 233-104c. National Institute for Occupational Safety and Health, Cincinnati, OH.","cited_authors":"September","cited_year":"1998","cited_title":"NIOSH. 1999a","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743276,"raw_reference":"April, 1999. NIOSH. 1999b. Control technology and exposure assessment for occupational exposure to crystalline silica: case 15 – concrete cutting. Report # ECTB 233-115c. National Institute for Occupational Safety and Health, Cincinnati, OH. November, 1999.","cited_authors":"April","cited_year":"1999","cited_title":"NIOSH. 1999b","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743277,"raw_reference":"NIOSH. 2000. In-depth survey report: Control technology for environmental enclosures – an evaluation of in-use enclosures at San Joaquin Helicopter. National Institute for Occupational Safety and","cited_authors":"NIOSH","cited_year":"2000","cited_title":"In-depth survey report: Control technology for environmental enclosures – an evaluation of in-use enclosures at San Joaquin Helicopter","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743278,"raw_reference":"Health, Cincinnati, OH, 1999. NIOSH. 2001a. Technology news: Sweeping compound application reduces dust from soiled floors within enclosed operator cabs (No. 487). National Institute for Occupational Safety and Health,","cited_authors":"Health, Cincinnati, OH","cited_year":"1999","cited_title":"NIOSH. 2001a","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743279,"raw_reference":"Pittsburgh, PA. March, 2001. NIOSH. 2001b. In-depth survey report of exposure to silica from hand tools in construction chipping, Occupational Safety and Health Administration grinding, and hand demolition at Frank Messer and Sons Construction Company: Lexington and","cited_authors":"Pittsburgh, PA. March","cited_year":"2001","cited_title":"NIOSH. 2001b","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743280,"raw_reference":"Newport, KY, Columbus and Springfield, OH. Report # 247-15. National Institute for Occupational Safety and Health, Cincinnati, OH, April, 2001.","cited_authors":"Newport, KY, Columbus and Springfield, OH. Report # 247-15. National Institute for Occupational Safety and Health, Cincinnati, OH, April","cited_year":"2001","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743281,"raw_reference":"NIOSH. 2002a. In-depth survey report of exposure to silica from demolition of plaster ceilings at Frank Messer and Sons Construction Company: Columbus,","cited_authors":"NIOSH","cited_year":"2002a","cited_title":"In-depth survey report of exposure to silica from demolition of plaster ceilings at Frank Messer and Sons Construction Company: Columbus","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743282,"raw_reference":"OH. Report # 247-15b. National Institute for Occupational Safety and Health, Cincinnati, OH, January, 2002.","cited_authors":"OH. Report # 247-15b. National Institute for Occupational Safety and Health, Cincinnati, OH, January","cited_year":"2002","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743283,"raw_reference":"NIOSH. 2002b. Pocket guide to chemical hazards. Pub. No. 2002-140. National Institute for Occupational Safety and Health, Cincinnati, OH.","cited_authors":"NIOSH","cited_year":"2002b","cited_title":"Pocket guide to chemical hazards","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743284,"raw_reference":"Plinke, M.A.E., Maus, R. and Leith, D. 1992. Experimental examination of factors that affect dust generation by using Heubach and MRI testers. Am. Ind. Hygiene. Assn. J. 53(5):325-330. May, 1992.","cited_authors":"Plinke, M.A.E., Maus, R. and Leith, D","cited_year":"1992","cited_title":"Experimental examination of factors that affect dust generation by using Heubach and MRI testers","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743285,"raw_reference":"Riala, R. 1988. Dust and quartz exposure of Finnish construction site cleaners. Ann. Occup. Hygiene 32(2):215-220, 1988.","cited_authors":"Riala, R","cited_year":"1988","cited_title":"Dust and quartz exposure of Finnish construction site cleaners","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743286,"raw_reference":"Saunders, Mark. 2000. Just say ‘No’ to dust…maybe. Grading and Excavation Contractor. May/June. www.forester.net/gec_0005_just.html.","cited_authors":"Saunders, Mark","cited_year":"2000","cited_title":"Just say ‘No’ to dust…maybe","cited_venue":null,"cited_doi":null,"cited_url":"www.forester.net/gec_0005_just.html","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743287,"raw_reference":"Skorseth, K. and Selim, A.. 2000. Gravel Roads Maintenance and Design Manual. USDOT, Federal Highway Administration. November, 2000.","cited_authors":"Skorseth, K. and Selim, A","cited_year":"2000","cited_title":"Gravel Roads Maintenance and Design Manual","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743288,"raw_reference":"Smandych, R.S., Thomson, M. and Goodfellow, H. 1998. Dust control for material handling operations: a systematic approach. Am. Ind. Hygiene Assn. J. 58:139-146. February, 1998.","cited_authors":"Smandych, R.S., Thomson, M. and Goodfellow, H","cited_year":"1998","cited_title":"Dust control for material handling operations: a systematic approach","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743289,"raw_reference":"Trakumas, S., Willeke, K., Ginshpun, S.A., Reponen, T., Mainelis, G. and Freidman, W. 2001. Particle emission characteristics of filter-equipped vacuum cleaners. Am. Ind. Hygiene Assn. J. 62:482-493. July/August, 2001.","cited_authors":"Trakumas, S., Willeke, K., Ginshpun, S.A., Reponen, T., Mainelis, G. and Freidman, W","cited_year":"2001","cited_title":"Particle emission characteristics of filter-equipped vacuum cleaners","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"journal_article","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743290,"raw_reference":"Westbrook, T. 1999. Managing fugitive dust. Presentation made at the Pollution Prevention Seminar for the Mining and Mineral Industries, Options for Reducing Dust Emissions, held in Mesa,","cited_authors":"Westbrook, T","cited_year":"1999","cited_title":"Managing fugitive dust","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743291,"raw_reference":"AZ, on September 16, 1999. References: Flanagan et al., 2003; NIOSH, 2002a, 1999a, 1999b; OSHA Case Files; Riala, 1988.","cited_authors":"AZ, on September 16","cited_year":"1999","cited_title":"References: Flanagan et al., 2003; NIOSH, 2002a, 1999a, 1999b; OSHA Case Files; Riala, 1988","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743292,"raw_reference":"NIOSH conducted video and real-time respirable dust monitoring in the employee’s breathing zone and simultaneously captured respirable dust on a cassette for gravimetric and X-ray diffraction analysis. Results indicated the respirable dust on the filter was 14.5 percent silica. This percentage was used to calculate the approximate silica exposure associated with the videotaped activities. NIOSH also sampled the employee’s full shift using traditional methods. Results indicated an 8-hour time-weighted average respirable silica exposure of 0.155 mg/m3 (0.182 mg/m3 for the 410-minute period sampled) (NIOSH, 2001b). Laboratories have not used particle counting for crystalline silica analysis for many years. Exposure data is now reported gravimetrically. However,","cited_authors":"NIOSH conducted video and real-time respirable dust monitoring in the employee’s breathing zone and simultaneously captured respirable dust on a cassette for gravimetric and X-ray diffraction analysis. Results indicated the respirable dust on the filter was 14.5 percent silica. This percentage was used to calculate the approximate silica exposure associated with the videotaped activities. NIOSH also sampled the employee’s full shift using traditional methods. Results indicated an 8-hour time-weighted average respirable silica exposure of 0.155 mg/m3 (0.182 mg/m3 for the 410-minute period sampled) (NIOSH","cited_year":"2001b","cited_title":"Laboratories have not used particle counting for crystalline silica analysis for many years","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743293,"raw_reference":"ACGIH recommends 3,500 to 4,000 feet per minute (FPM) velocity (within the hose/duct) to keep concrete dust and particles released from grinding from settling in the hose (ACGIH, 2001). For a typical 2-","cited_authors":"ACGIH recommends 3,500 to 4,000 feet per minute (FPM) velocity (within the hose/duct) to keep concrete dust and particles released from grinding from settling in the hose (ACGIH","cited_year":"2001","cited_title":"For a typical 2-","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743294,"raw_reference":"EXPOSURES CONSTRUCTION inch diameter vacuum hose, 75 to 90 cubic feet per minute (CFM) will achieve that duct velocity (ACGIH, 2001). However, for maximum collection efficiency, the shroud may require higher CFM.","cited_authors":"EXPOSURES CONSTRUCTION inch diameter vacuum hose, 75 to 90 cubic feet per minute (CFM) will achieve that duct velocity (ACGIH","cited_year":"2001","cited_title":"However, for maximum collection efficiency, the shroud may require higher CFM","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743295,"raw_reference":"NIOSH (2001b) showed that airflow through a vacuum dropped by two-thirds (from 87 to 31 CFM) as the vacuum bag filled. The lower airflow was not adequate to prevent dust from settling in the hose. For some small vacuums, “pleated” filters with large surface areas can help solve the problem of low suction power. Controlled tests of aerosol penetration into agricultural tractor cabs have shown that a retrofitted cabin can filter out 99.6 percent of particles 0.3 µm to 0.4 µm in diameter (NIOSH, 2000). Flanagan et al., 2003, evaluated peak and average respirable dust exposure using personal dust monitors to record multiple one-minute average results during various phases of a task. Observers recorded work variables for each minute. Eleven crystalline silica samples associated with employees performing cleanup were collected using nylon cyclones and air sampling pumps. Results were reported by major activity group (cleanup) as geometric mean and as percent exceeding the","cited_authors":"NIOSH","cited_year":"2001b","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743296,"raw_reference":"ACGIH TLV (0.05 mg/m3). Employees recorded their own activities during the period sampled (sample durations were not reported, but were less than fullshift) (Flanagan et al., 2003).","cited_authors":"ACGIH TLV (0.05 mg/m3). Employees recorded their own activities during the period sampled (sample durations were not reported, but were less than fullshift) (Flanagan et al","cited_year":"2003","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743297,"raw_reference":"Riala (1988) analyzed respirable quartz using sedimentation to separate particles less than 5 µm from total dust samples, rather than by sampling with a cyclone. Additionally, respirable quartz was analyzed in 9 of 110 samples and estimated for the remainder. The average breathing zone silica results were 0.530 mg/m3 for dry sweeping, 0.33 mg/m3 when squeegees were used, and 0.06 to 0.10 mg/m3 during vacuum cleaning. Mean sample durations were approximately 90 minutes. Cleanup worker exposures were notably higher than reported by Flanagan et al., 2003. Occupational Safety and Health Administration","cited_authors":"Riala","cited_year":"1988","cited_title":"analyzed respirable quartz using sedimentation to separate particles less than 5 µm from total dust samples, rather than by sampling with a cyclone","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743298,"raw_reference":"OSHA published recommended Safety and Health Program Management Guidelines (54 Federal Register (16): 3904-3916, January 26, 1989). These voluntary guidelines can be applied to all places of employment covered by OSHA. The guidelines identify four general elements critical to the development of a successful safety and health management system: • Management leadership and worker involvement, • Worksite analysis, • Hazard prevention and control, and • Safety and health training. The guidelines recommend specific actions, under each of these general elements, to achieve an effective safety and health management system. The Federal Register notice is available online at www.osha.gov. State Programs The Occupational Safety and Health Act of 1970 (OSH Act) encourages states to develop and operate their own job safety and health plans. OSHA approves and monitors these plans. Twenty-four states, Puerto Rico and the Virgin Islands currently operate approved state plans: 22 cover both private and public (state and local government) employment; Connecticut, New","cited_authors":"OSHA published recommended Safety and Health Program Management Guidelines (54 Federal Register (16): 3904-3916, January 26","cited_year":"1989","cited_title":"These voluntary guidelines can be applied to all places of employment covered by OSHA. The guidelines identify four general elements critical to the development of a successful safety and health management system: • Management leadership and worker involvement, • Worksite analysis, • Hazard prevention and control, and • Safety and health training","cited_venue":null,"cited_doi":null,"cited_url":"www.osha.gov","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743299,"raw_reference":"EXPOSURES CONSTRUCTION For more information on grants, training and education, contact the OSHA Training Institute, Directorate of Training and Education, 2020 South Arlington Heights Road, Arlington Heights, IL 60005, (847) 2974810, or see Training on OSHA’s website at www.osha.gov. For further information on any OSHA program, contact your nearest OSHA regional office listed at the end of this publication. Information Available Electronically","cited_authors":null,"cited_year":null,"cited_title":"EXPOSURES CONSTRUCTION For more information on grants, training and education, contact the OSHA Training Institute, Directorate of Training and Education, 2020 South Arlington Heights Road, Arlington Heights, IL 60005, (847) 2974810, or see Training on OSHA’s website at www.osha.gov","cited_venue":null,"cited_doi":null,"cited_url":"www.osha.gov","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743300,"raw_reference":"Avenue, NW, N-3101, Washington, DC 20210; telephone (202) 693-1888 or fax to (202) 693-2498. Contacting OSHA To report an emergency, file a complaint, or seek","cited_authors":null,"cited_year":null,"cited_title":"Avenue, NW, N-3101, Washington, DC 20210; telephone (202) 693-1888 or fax to (202) 693-2498","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743301,"raw_reference":"Washington, DC 20210. By visiting OSHA’s website at www.osha.gov, you can also: • File a complaint online, • Submit general inquiries about workplace safety and health electronically, and • Find more information about OSHA and occupational safety and health. (OOC 5/2009) Occupational Safety and Health Administration","cited_authors":null,"cited_year":null,"cited_title":"Washington, DC 20210","cited_venue":null,"cited_doi":null,"cited_url":"www.osha.gov","ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":3743302,"raw_reference":"JFK Federal Building, Room E340 Boston, MA 02203 (617) 565-9860 Region VIII (CO, MT, ND, SD, UT,* WY*) 1999 Broadway, Suite 1690","cited_authors":null,"cited_year":null,"cited_title":"JFK Federal Building, Room E340 Boston, MA 02203 (617) 565-9860 Region VIII (CO, MT, ND, SD, UT,* WY*) 1999 Broadway, Suite 1690","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null}]}