TESTING FACILITIES AND/OR FACILITIES USING THE TECHNOLOGY: Louver barrier devices have been tested and/or are in use at the following facilities: the California Department of Water Resource's Tracy Pumping Plant; the California Department of Fish and Game's Delta Fish Protective Facility in Bryon; the Conte Anadromous Fish Research Center in Massachusetts, and the San Onofre Nuclear Generating Station in California (EPA, 1976; EPRI, 1985; EPRI, 1999). In addition, three other plants also have louvers at their facilities: the Ruth Falls Power Plant in Nova Scotia, the Nine Mile Point Nuclear Power Station on Lake Erie, and T.W. Sullivan Hydroelectric Plant in Oregon. Louvers have also been tested at the Ontario Hydro Laboratories in Ontario, Canada (Ray et al, 1976). A-25 .23? P.88
California, testing was performed from 1993 and 1995 to determine the guidance efficiency of a system with primary and secondary louvers. The results for green and white sturgeon, American shad, splittail, white catfish, delta smelt, Chinook salmon, and striped bass showed mean diversion efficiencies ranging from 63 (splittail) to 89 percent (white catfish) (EPRI, 1999). A-26 P.89 In 1984 at the San Onofre Station, a total of 196,978 fish entered the louver system with 188,583 returned to the waterbody and 8,395 impinged. In 1985,407,755 entered the louver system with 306,200 returned and 101,555 impinged. Therefore, the guidance efficiencies in 1984 and 1985 were 96 and 75 percent, respectively.
However, 96-hour survival rates for some species, i.e., anchovies and croakers, were 50 percent or less. Louvers were originally considered for use at San Onofre because of 1970s pilot testing at the Redondo Beach Station in California where maximum guidance efficiencies of 96-100 percent were observed. (EPRI, 1999) At the Maxwell Irrigation Canal in Oregon, louver spacing was 5.0 cm with a 98 percent efficiency of deflecting immature steelhead and above 90 percent efficiency for the same species with a louver spacing of 10.8 cm. At the Ruth Falls Power Plant in Nova Scotia, the results of a five-year evaluation for guiding salmon smelts showed that the optimum spacing was to have wide bar spacing at the widest part of the louver with a gradual reduction in the spacing approaching the bypass. The site used a bypass:approach velocity ratio of 1.0 : 1.5 (Ray et al, 1976). Coastal species in California were deflected optimally (Schuler and Larson, 1974 in Ray et al, 1976) with 2.5 cm spacing ofthe louvers, 20 degree louver array to the direction of flow and approach velocities of 0.6 cm per second. At the T.W. Sullivan Hydroelectric Plant along the Williamette River in Oregon, the louver system is estimated to be 92 percent effective in diverting spring Chinook, 82 percent for all Chinook, and 85 percent for steelhead. The system has been optimized to reduce fish injuries such that the average injury occurrence is only 0.44 percent (EPRI, 1999).
DESIGN CONSIDERATIONS: The most important parameters ofthe design of louver barriers include the following: The angle ofthe louver vanes in relation to the channel velocity, The spacing between the louvers which is related to the size ofthe fish, Ratio of bypass velocity to channel velocity, Shape of guide walls, Louver array angles, and Approach velocities. A-27 P.90 Site-specific modeling may be needed to take into account species-specific considerations and optimize the design efficiency (EPA, 1976; O'Keefe, 1978).
ADVANTAGES: Louver designs have been shown to be very effective in diverting fish (EPA, 1976).
LIMITATIONS: The costs of installing intakes with louvers may be substantially higher than other technologies due to design costs and the precision required during construction. Extensive species-specific field testing may be required. The shallow angles required for the efficient design ofa louver system require a long line of louvers increasing the cost as compared to other systems (Ray et al, 1976). Water level changes must be kept to a minimum to maintain the most efficient flow velocity. Fish handling devices are needed to take fish away from the louver barrier. Louver barriers may, or may not, require additional screening devices for removing solids from the intake waters. If such devices are required, they may add a substantial cost to the system (EPA, 1976). Louvers may not be appropriate for offshore intakes (Mussalli, 1980).
REFERENCES: Chow, W., I.P. Murarka, R.W. Broksen. "Entrainment and Impingement in Power Plant Cooling Systems." Literature Review. Journal Water Pollntinn Cnntrnl Federation 53 (6)(1981):965-973. U.S. EPA. Development Dncnment fnr Best Technnlngy Available for the T.ncatinn, Design,
Construction, and Capacity of Cnnling Water TntaVe Struchires fnr Minimizing Adverse Environmental Impact. U.S. Environmental Protection Agency, Effluent Guidelines Division, Office of Water and Hazardous Materials. April 1976. Electric Power Research Institute (EPRI). Fish Prntectinn at Cnnling Water TntaVes- Stafris Repnrt 1999.
EPRI. TntaVe Research Facilities Manual. Prepared by Lawler, Matusky & Skelly Engineers, Pearl River, New York for Electric Power Research Institute. EPRI CS-3976. May 1985. Hadderingh. R.H. "Fish Intake Mortality at Power Stations, the Problem and its Remedy." N.V. Kema. A-2R P.91
Arnheem, Netherlands. Hydrological Bulletin 13(2-3) (1979): 83-93.
Mussalli, Y.G., E.P. Taft, and P. Hoffman. "Engineering Implications of New Fish Screening Concepts," In Fourth National WnrVshnp nn F.ntrainment and impingement, L.D. Jensen (Ed.), Ecological Analysts, Inc. Melville, NY. Chicago, Dec. 1977.
Mussalli, Y.G., E.P Taft UI and J. Larson. "Offshore Water Intakes Designed to Protect Fish." Journal of the Hydraulics Division Proceedings ofthe American Society of Civil Engineers. Vol. 1 0 6 H y l l (1980): 1885-1901.
O'Keefe, W., Intake Technology Moves Ahead. Power January 1978.
Ray, S.S. and R.L. Snipes and D.A. Tomljanovich. A State-of-fhe-Art Repnrt nn Intake Technnlngies Prepared for Office of Energy, Minerals, and Industry, Office of Research and Development. U.S. Environmental Protection Agency, Washington, D.C. by the Tennessee Valley Authority. EPA 600/7-76020. October 1976.
Uziel, Mary S. "Entrainment and Impingement at Cooling Water Intakes." Literature Review. Tnumal Water Pollution Cnntrnl Federation 52 (6) (1980): 1616-1630.
Bates, D.W. and R. Vinsonhaler, "The Use of Louvers for Guiding Fish." Trans Am Fish Snc 86 (1956):39-57.
Bates, D.W., and S.G., Jewett Jr., "Louver Efficiency in Deflecting Downstream Migrant Steelhead, " Trans Am Fish Snc 90(3)(1961):336-337.
Cada, G.G., and A.T. Szluha. "A Biological Evaluation of Devices Used for Reducing Entrainment and Impingement Losses at Thermal Power Plants." In Tnternatinnal Sympnsinm nn the Environmental Effects nf Hydraulic Engineering Works Environmental Sciences Division, Publication No. 1276. Oak Ridge Nat'l. Lab., Oak Ridge TN (1978).
ORAL/TM-6473. Oak Ridge Nat'l. Lab. Oak Ridge, TN (1979).
Ducharme, L.J.A. "An Application of Louver Deflectors for Guiding Atlantic Salmon (Salmo salar) Smolts from Power Turbines." Journal Fisheries Research Rnard of Canada 29 (1974): 1397-1404. A-29 P.92
Screen, 1966-67" Marine Resources Branch, California Department of Fish and Game (1968).
Katapodis, C. et al. A Study nf Mndel and Prntntype Culvert Baffling fnr Fish Passage Marine Service, Tech. Report No. 828. Winnipeg, Manitoba (1978). Fisheries and
Kerr, J.E., "Studies on Fish Preservation at the Contra Costa Steam Plant ofthe Pacific Gas and Electric Co," California Fish and Game Rnlletin No. 92 (1953).
NUS Corporation. Pittsburgh, PA (1978). NUS Corp., "Review of Best Technology Available for Cooling Water Intakes." Los Angeles Dept of Water & Pnwer Repnrt, Los Angeles CA (1978).
Schuler, V.J., "Experimental Studies In Guiding Marine Fishes of Southern California with Screens and I Olivers," Tchthyol Assoc , Rnlletin 8 (1973)
Baltimore, Maryland. February 5-9, 1973. pp 225-249 (Edison Electric Institute and Electric Power Research Institute, EPRI Publication No. 74-049-00-5 (1974). Stone and Webster Engineering Corporation, Smdies tn Alleviate Pntential Fish Entrapment Prnhlems Final Report, Nine Mile Pnint Nuclear Statinn - Unit 2. Prepared for Niagara Mohawk Power
Corporation, Syracuse, New York, May 1972. Stone and Webster Engineering Corporation. Final Report, Indian Point Flume Smdy Consolidated Edison Company of New York, IN. July 1976. Prepared for
Taft, E.P., and Y.G. Mussalli, "Angled Screens and Louvers for Diverting Fish at Power Plants," Proceedings of the American Society of Civil Engineers, Journal of Hydraulics Division. Vol 104 (1978):623-634.
Olympia, Washington (1967). Watts, F.J., "Design of Culvert Fishways." University of Tdaho Water Resources Research Institute
Repnrt, Moscow, Idaho (1974). A-30 P.93 Fish Diversion or Avoidance Systems Fact Sheet No. 9: Velocity Cap
DESCRIPTION: A velocity cap is a device that is placed over vertical inlets at offshore intakes (see figure below). This cover converts vertical flow into horizontal flow at the entrance into the intake. The device works on the premise that fish will avoid rapid changes in horizontal flow. Fish do not exhibit this same avoidance behavior to the vertical flow that occurs without the use of such a device. Velocity caps have been implemented at many offshore intakes and have been successful in decreasing the impingement offish. Typical Offshore Coling Water Intake Structure with Velocity Caps (Helrey, 1985; ASCE, 1982)
TESTING FACILITIES AND/OR FACILITIES USING THE TECHNOLOGY: The available literature (EPA, 1976; Hanson, 1979; and Pagano et al, 1977) states that velocity caps have been installed at offshore intakes in Southern California, the Great Lakes Region, the Pacific Coast, the Caribbean and overseas; however, exact locations are not specified. Velocity caps are known to have been installed at the El Segundo, Redondo Beach, and Huntington Beach Steam Electric Stations and the San Onofre Nuclear Generation Station in Southern California (Mussalli, 1980; Pagano et al, 1977; EPRI, 1985). Model tests have been conducted by a New York State Utility (ASCE, 1982) and several facilities have installed velocity caps in the New York State /Great Lakes Area including the Nine Mile Point Nuclear Station, the Oswego Steam Electric Station, and the Kintigh Generating Station (EPRI, 1985). Additional known facilities with velocity caps include the Edgewater Generation Station in
Wisconsin, the Seabrook Power Plant in New Hampshire, and the Nanticoke Thermal Generating Station in Ontario, Canada (EPRI, 1985). A-31 P.94
RESEARCH/OPERATION FINDINGS: Horizontal velocities within a range of 0.5 to 1.5 feet per second (ft/sec) did not significantly affect the efficiency ofa velocity cap tested at a New York facility; however, this design velocity may be specific to the species present at that site (ASCE, 1982). Preliminary decreases in fish entrapment averaging 80 to 90 percent were seen at the El Segundo and Huntington Beach Steam Electric Plants (Mussalli, 1980). Performance ofthe velocity cap may be associated with cap design and the total volumes of water flowing into the cap rather than to the critical velocity threshold ofthe cap (Mussalli, 1980).
DESIGN CONSIDERATIONS: Designs with rims around the cap edge prevent water from sweeping around the edge causing turbulence and high velocities, thereby providing more uniform horizontal flows (EPA, 1976; Mussalli, 1980). Site-specific testing should be conducted to determine appropriate velocities to minimize entrainment of particular species in the intake (ASCE, 1982). Most structures are sized to achieve a low intake velocity between 0.5 and 1.5 ft/sec to lessen the chances of entrainment (ASCE, 1982). Design criteria developed for a model test conducted by Southem California Edison Company used a velocity through the cap of 0.5 to 1.5 ft/sec; the ratio ofthe dimension ofthe rim to the height ofthe intake areas was 1.5 to 1 (ASCE, 1982; Schuler, 1975).
ADVANTAGES: Efficiencies of velocity caps on West Coast offshore intakes have exceeded 90 percent (ASCE, 1982).
LIMITATIONS: Velocity caps are difficult to inspect due to their location under water (EPA, 1976). In some studies, the velocity cap only minimized the entrainment of fish and did not eliminate it. Therefore, additional fish recovery devices are be needed in when using such systems (ASCE, 1982; Mussalli, 1980). Velocity caps are ineffective in preventing passage of non-motile organisms and early life stage fish (Mussalli, 1980). A-32 P.95
REFERENCES: ASCE. Design of Water Intake Structures for Fish Protection. American Society of Civil Engineers, New York, NY. 1982.
River, New York for Electric Power Research Institute. EPRI CS-3976. May 1985.
Hanson, C.H., et al. "Entrapment and Impingement of Fishes by Power Plant Cooling Water Intakes: An Overview." Marine Fisheries Review October 1977.
Mussalli, Y.G., E.P Taft IU and J. Larson. "Offshore Water Intakes Designed to Protect Fish." Journal of the Hydraulics Division Proceedings of the American Society of Civil Engineers, Vol. 106 Hyl 1 (1980): 1885-1901.
Pagano R. and W.H.B. Smith. Recent Pevelnpment in Techniques tn Prntect Aquatic Organisms at the Water Intakes nf Steam Electric Power Plants. Prepared for Electricite' de France. MTTRE Technical Report 7671. November 1977.
Ray, S.S. and R.L. Snipes and D.A. Tomljanovich. A State-of-the-Art Repnrt on Intake Technologies Prepared for Office of Energy, Minerals, and Industry, Office of Research and Development. U.S. Environmental Protection Agency, Washington, D.C. by the Tennessee Valley Authority. EPA 600/7-76020. October 1976. U.S. EPA. Development Document for Best Technology Available for the Locatinn, Design,
Tmpact U.S. Environmental Protection Agency, Effluent Guidelines Division, Office of Water and Hazardous Materials. April 1976.
ADDITIONAL REFERENCES: Maxwell, W.A. Fish Diversion for Electrical Generating Station Cooling Systems a State nf the Art Report. Southern Nuclear Engineering, Inc. Report SNE-123, NUS Corporation, Dunedin, FL. (1973) 78p.
Weight, R.H. "Ocean Cooling Water System for 800 MW Power Station." J. Power Div., Prnc Am Snc Civil Engr 84(6)(1958): 1888-1 to 1888-222. Stone and Webster Engineering Corporation. Smdies tn Alleviate Fish Entrapment at Pnwer Plant Cnnling Water TntaVes, Final Repnrt Prepared for Niagara Mohawk Power Corporation and Rochester Gas and Electric Corporation, November 1976.
Richards, R.T. "Power Plant Circulating Water Systems - A Case Study." Short Course on the Hydraulics of Cooling Water Systems for Thermal Power Plants. Colorado State University. June 1978. A-33 P.96 Fish Diversion or Avoidance Systems Fact Sheet No. 10: Fish Barrier Nets
DESCRIPTION: Fish barrier nets are wide mesh nets, which are placed in front of the entrance to an intake structure (see figure below). The size of the mesh needed is a function of the species that are present at a particular site. Fish barrier nets have been used at numerous facilities and lend themselves to intakes where the seasonal migration of fish and other organisms require fish diversion facilities for only specific times ofthe year. V-Arrangement of Fish Barrier Net (ASCE, 1982)
TESTING FACILITIES AND/OR FACILITIES USING THE TECHNOLOGY: The Bowline Point Generating Station, the J.P. Pulliam Power Plant in Wisconsin, the Ludington Storage Plant in Michigan, and the Nanticoke Thermal Generating Station in Ontario use barrier nets (EPRI, 1999). Barrier Nets have been tested at the Detroit Edison Monroe Plant on Lake Erie and the Chalk Point Station on the Patuxent River in Maryland (ASCE, 1982; EPRI, 1985). The Chalk Point Station now uses barrier nets seasonally to reduce fish and Blue Crab entry into the intake canal (EPRI, 1985). The Pickering Generation Station in Ontario evaluated rope nets in 1981 illuminated by strobe lights (EPRI, 1985).
RESEARCH/OPERATION FINDINGS: At the Bowline Point Generating Station in New York, good results (91 percent impingement reductions) have been realized with a net placed in a V arrangement around the intake structure (ASCE, 1982; EPRI, 1999). In 1980, a barrier net was installed at the J.R. Whiting Plant (Michigan) to protect Maumee Bay. Prior to net installation, 17,378,518 fish were impinged on conventional traveling screens. With the net, sampling in 1983 and 84 showed 421,978 fish impinged (97 percent effective), sampling in 1987 showed 82,872 fish impinged (99 percent effective), and sampling in 1991 showed 316,575 fish impinged (98 percent effective) (EPRI, 1999). A-34 P.97 Nets tested with high intake velocities (greater than 1.3 feet per second) at the Monroe Plant have clogged and subsequentially collapsed. This has not occurred at facilities where the velocities are 0.4 to 0.5 feet per second (ASCE, 1982). Barrier nets at the Nanticoke Thermal Generating Station in Ontario reduced intake of fish by 50 percent (EPRI, 1985).