Policy Replication

Technical Development Document for the Final Regulations Addressing Cooling Water Intake Structures for New Facilities [W-00-03-DCN-3-0002]

Docket document2025-12-29 · EPA · publication · EPA-HQ-OW-2002-0052-0402
RIN 2040-AC34, RIN 2040-AC23 · Docket EPA-HQ-OW-2002-0052

Other documents for the same rulemaking

1998-06-25 Federal RegisterEffluent Limitations Guidelines, Pretreatment Standards, and New Source Performance Standards for the Transportation Equipment Cleaning Point Source Category
2000-08-10 Federal RegisterNational Pollutant Discharge Elimination System-Regulations Addressing Cooling Water Intake Structures for New Facilities
2001-12-18 Federal RegisterNational Pollutant Discharge Elimination System: Regulations Addressing Cooling Water Intake Structures for New Facilities
2007-06-08 Regulatory impact analysisIdentification of NEWGen Facilities for the Economic Analysis of the Proposed 316(b) New Facility Rule-[DCN 1-6001 AD] [W-00-03]
2007-06-08 Regulatory impact analysisMemo from Abt Associates, Inc. entitled" Identification of NEWGen Facilities for the Economic Analysis of the 316(b) New Facility Rule" [DCN 2-006] [W-00-03]
2025-04-10 Docket documentLegacy Index for Docket W-00-03. See attachments for the Comments' Indexes
2025-04-17 Docket documentFederal Register of December 18, 2001 [65255 FR 66] [FRL-7105-4] - Copy
2025-06-27 Docket documentRenewal Application for Salem Generating Station Permit No. NJ00005622. Appendix F, Attachments 1 & 2. Baywide and In Plant Sampling Programs and Sampling Methods; and Model Methodologies and Common Input Parameters [W-00-03-CN-2-013C]
2025-06-27 Docket documentPreliminary Regulatory Development Section 316 (b) of the Clean Water Act Background Paper Number 3: Cooling Water Intake Technologies [W-00-03-DCN-1-5069-PR]
2025-06-27 Docket documentPatterns of Life History. Diversification in North American Fishes: Implications for Population Regulation [W-00-03-DCN-2-13B]
2025-06-27 Docket documentBrunswick Nuclear Steam Electric Generating Plant of Carolina Power and Light Company, Historical Summary and Review of Section 316(b) Issues [W-00-03-DCN-1-5065-PR]
2025-06-27 Docket documentPercentages of In-Scope Facilities Using Various Proportions of Their Int ake Water for Cooling Purposes [W-00-03-DCN-2-002]
2025-06-27 Docket documentPreliminary Regulatory Development Section 316(B) of the Clean Water Act Background Paper Number 1: Legislative. Regulatory, and Legal History of Section 316(b) and Information on Federal and State Implementation of Cooling Water Intake Structure Technology Requirements [W-00-03-DCN-1-6002-AD]
2025-06-27 Docket documentPercentages of In-Scope Facilities Meeting Various Design Intake Flow Thresholds [W-00-03-DCN-2-003]
2025-06-27 Docket documentMemo RE: Notes from April 4, 2001 Meeting with US Coast Guard [W-00-03-DCN-2-012A]
2025-06-27 Docket documentSection 316(b) Public Meeting Notes [W-00-03-DCN-1-7001-EF]
2025-06-27 Docket documentIndustry Meeting Summaries [W-00-03-DCN-1-5068-PR]
2025-06-27 Docket documentSection 316(b) Public Meeting Notes [W-00-03-DCN-1-7000-EF]
2025-06-27 Docket documentEnvironmental Group Summaries [W-00-03-DCN-1-5073-PR]
2025-06-27 Docket documentMemo RE: Cooling Water Intake Structures, Mobile Offshore Drilling Units [W-00-03-DCN-2-012D]
2025-07-16 Regulatory impact analysisElectric Power Annual 1995, Volume I, US Department of Energy, Energy Information Administration (EIA), Economic Analysis, DOE /EIA-03 48(9 5)/1 [W-00-03-DCN-1-2112-EA]
2025-07-16 Regulatory impact analysisThe Struggle to Compete, Metal Center News Online, Economic Analysis, http://www.metalcenter.co m/metalistribution/md mill. htm [W-00-03-DCN-1-2104-EA]
2025-07-16 Regulatory impact analysisPetroleum Industry Environmental Performance: 6th Annual Report (STEP Report), Economic Analysis, American Petroleum Institute [W-00-03-DCN-1-2120-EA]
2025-07-16 Regulatory impact analysisEstimated Use of Water in the United States in 1995, USGS Circular 1200, US Geological Survey, Economic Analysis [W-00-03-DCN-1-2116-EA]
2025-07-16 Regulatory impact analysisImpacts of Electric Power Industry Restructuring on the Coal Industry, US Department of Energy, Energy Information Administration (EIA), Economic Analysis [W-00-03-DCN-1-2111-EA]
2025-07-16 Regulatory impact analysisU.S. pulp, paper, board capacity growth, ultra slow, Pulp and Paper Online, Economic Analysis, http://www.pp online.com/d b_area/ archive/ pponews/ 19 99/wk 12.06.1999/38 .htm [W-00-03-DCN-1-2105-EA]
2025-07-16 Regulatory impact analysisSupporting Analysis for the Comprehensive Electricity Competition Act, US Department of Energy, Economic Analysis, DOE/PO-0059 [W-00-03-DCN-1-2106-EA]
2025-07-16 Regulatory impact analysisFinancial Developments in 96-97: How the U.S. Majors Survived the 1998 Crude Oil Price Storm, Economic Analysis, http://www.eia.doe.gov/eme u/finan ce/highlite 7/sld0 01.htm [W-00-03-DCN-1-2124-EA]
2025-07-16 Regulatory impact analysisStandard Industrial Classification Manual, 1987, Executive Office of the President, Office of Management and Budget, OMB, Economic Analysis [W-00-03-DCN-1-2121-EA]
2025-07-16 Regulatory impact analysisAluminum: An American Industry Profile, http://www.aluminum.org, The Aluminum Association, Economic Analysis [W-00-03-DCN-1-2129-EA]
2025-07-16 Regulatory impact analysisCompetitive Electricity Prices: An Update, Issues in Mid term Ana lysis and Forecasting 1998, Economic Analysis [W-00-03-DCN-1-2110-EA]
2025-07-16 Regulatory impact analysisRestructuring, Competition and Regulatory Reform in the U.S. Electricity Sector, Journal of Economic Perspectives, Volume 11, Number 3, Summer 1997, Economic Analysis [W-00-03-DCN-1-2118-EA]
2025-07-16 Regulatory impact analysisElectric Power Annual 1995, Volume II, DOE /EIA-03 48(9 5)/2, US Department of Energy, Energy Information Administration (EIA) Economic Analysis [W-00-03-DCN-1-2113-EA]
2025-07-16 Regulatory impact analysisElectric Power Industry Overview,US Department of Energy, Energy Information Administration (EIA, Economic Analysis, http://www.eia.doe.gov/cne af/electricity/page/prim2.html [W-00-03-DCN-1-2115-EA]
2025-07-16 Regulatory impact analysisEconomic State of the US Petroleum Industry, American Petroleum Institute Policy Analysis and Strategic Planning Department, Economic Analysis [W-00-03-DCN-1-2119-EA]
2025-07-16 Regulatory impact analysisAssumptions to the AEO 2000 with Projections to 2020, US Department of Energy, Energy Information Administration (EIA, Economic Analysis, DOE/EIA-0554(2000) [W-00-03-DCN-1-2103-EA]
2025-07-16 Regulatory impact analysisSIC Dvision Structure, Occupational Safety and Health Administration (OSHA), Economic Analysis, http://www.osh a.gov/cgi- bin/sic/sicser5 [W-00-03-DCN-1-2108-EA]
2025-07-16 Docket documentStatistics of U.S. Businesses, http://www.sba.gov/advo /stats/int data. html [W-00-03-DCN-1-2125-EA]
2025-07-16 Docket documentPetroleum 1996: Issues and Trends, DOE/EIA-0615, 09/1997 [W-00-03-DCN-1-2131-EA]
2025-07-16 Docket documentEconomic Analysis Abt Associates, Inc. Number of Nonutil, Plants, Units, & Cap.xls [W-00-03-DCN-1-2312N-EA]
2025-07-16 Docket documentDraft for Inform al Interagency Review by OMB: Section 316(b) New Facility Preamble and Proposed Rule, Federal Agency Input, USEPA [W-00-03-DCN-1-1058-TC]
2025-07-16 Docket documentDraft for Formal OMB Review: Section 316(b) New Facility Preamble and Proposed Rule, Economic and Engineering Analyses, and Information Collection Request, Federal Agency Input, USEPA [W-00-03-DCN-1-1059-TC]
2025-07-16 Docket documentApplicability of Proposed and Final Rule, Stakeholder Meeting/Correspondence, Utility Water Act Group (UWAG) [W-00-03-DCN-1-1071-TC]
2025-07-16 Docket documentPossible Problems with Application of New Source Section 316 (b) Standards to Cogeneration, Stakeholder Meeting/Correspondence, American Forest and Paper Association, [W-00-03-DCN-1-1002-TC]
2025-07-16 Docket documentSubject: Response to Legal Argument Opposing Adoption of Draft Cease and Desist Order 00-032 for Diablo Canyon Nuclear Power Plan, California Regional l Water Quality Control Board, Central Coast Region, Environmental Impact [W-00-03-DCN-1-1035-TC]
2025-07-16 Docket documentFig % Cap by Ownership.xls [W-00-03-DCN-1-2315N-EA]
2025-07-16 Docket documentCen a sm29.x ls [W-00-03-DCN-1-2321N-EA]
2025-07-16 Docket documentSusb29 11.xls [W-00-03-DCN-1-2323N-EA]
2025-07-16 Docket documentByCw sSrc.xls [W-00-03-DCN-1-2331N-EA]
2025-07-16 Docket documentEffects of Impingement/Entrainment at the Kanaw ha River Plant on the F ish Comm unity Structure of the Kanawha River: Reflections on the 20 Year Study [W-00-03-DCN-1-3007-BE]
2025-07-16 Docket documentSupplemental Assessment in Support of the 316 Demonstration, Pilgrim Nuclear Power Station Units 1 and 2 [W-00-03-DCN-1-3072-BE]
2025-07-16 Docket documentBiological Effects of Once-Through Cooling Part I, Volume 2: The Marine Environment [W-00-03-DCN-1-3084-BE]
2025-07-16 Docket documentFinal Report of the Marine Review Commttee to the California Coastal Commission [W-00-03-DCN-1-5013-PR]
2025-07-16 Docket documentTechnical Support Document for Water Quality-based Toxics Control [W-00-03-DCN-1-5055-PR]
2025-07-16 Docket documentDiablo Canyon Power Plant: 31 6(b) Demonstration Report, Pacific Gas and Electric Co., Environmental Impact [W-00-03-DCN-1-1023-TC]
2025-07-16 Docket documentDesign Intake Flows of Top 1/3 Riverine Facilities (excluding nuclear), USEPA [W-00-03-DCN-1-1055-TC]
2025-07-16 Docket documentDraft, Section 316(b) Regulatory Development Project Data for Use in Evaluating Options for De Minimus Flow, Tetra Tech, Inc., USEPA, BTA-Flow [W-00-03-DCN-1-1049-TC]
2025-07-16 Docket documentCapability & Generation by Fuel [W-00-03-DCN-1-2314F-EA]
2025-07-16 Docket documentCen A sm33.x ls [W-00-03-DCN-1-2325N-EA]
2025-07-16 Docket documentInspuse1.xls [W-00-03-DCN-1-2330F-EA]

References: 257 extracted, 0 linked to papers

Page 3Download these results: CSV · JSON
Fritz, E.S. Conling Water TntaVe Screening Devices Used to Reduce F.ntrainment and Impingement Topical Briefs: Fish and Wildlife Resources and Electric Power Generation, No. 9, 1980. c22/ P.70
research reportNot linked to a paper · refsec
King, L.R., J.B. Hutchinson, Jr. and T.G. Huggins. "Impingement Survival Studies on White Perch, Striped Bass, and Atlantic Tomcod at Three Hudson Power Plants". In Fnnrfh National Workshop on F.ntrainment and Impingement, L.D. Jensen (Editor) Ecological Analysts, Inc., Melville, NY. Chicago, December 1977.
research reportNot linked to a paper · refsec
Mussalli, Y.G., "Engineering Implications of New Fish Screening Concepts". In Fourth National WorVshop nn F.ntrainment and Impingement, L.D. Jensen (Editor). Ecological Analysts, Inc., Melville, N.Y. Chicago, December 1977, pp 367-376.
research reportNot linked to a paper · refsec
Pagano, R. and W.H.B. Smith. Recent Developments in Techniques tn Protect Agnatic Organisms at the IntaVes Steam-Flecrric Power Plants MITRE Technical Report 7671. November 1977.
research reportNot linked to a paper · refsec
Analysts, Inc., Melville, N.Y. Chicago, December 1977.
research reportNot linked to a paper · refsec
White, J.C. and M.L. Brehmer. "Eighteen-Month Evaluation ofthe Ristroph Traveling Fish Screens". In Third National WnrVshnp nn F.ntrainment and Impingement L.D. Jensen (Editor). Ecological Analysts, Inc., Melville, N.Y. 1976. P.71 Intake Screening Systems Fact Sheet No. 3: Inclined Single-Entrv, SingleExit Traveling Screens (Angled Screens)
research reportNot linked to a paper · refsec
DESCRIPTION: Inclined traveling screens utilize standard through-flow traveling screens where the screens are set at an angle to the incoming flow as shown in thefigurebelow. Angling the screens improves thefishprotection effectiveness ofthe flush mounted vertical screens since thefishtend to avoid the screen face and move toward the end of the screen line, assisted by a component of the inflow velocity. A fish bypass facility with independently induced flow must be provided. The fish have to be lifted by fish pump, elevator, or conveyor and discharged to a point of safety away from the main water intake (Richards, 1977). fig : Richards, 4 page 419 Inclined Traveling Screens (Richards, 1977)
research reportNot linked to a paper · refsec
TESTING FACILITIES AND/OR FACILITIES USING THE TECHNOLOGY: Angled screens have been tested/used at the following facilities: the Brayton Point Station Unit 4 in Massachusetts; the San Onofre Station in California; and at power plants on Lake Ontario and the Hudson River (ASCE, 1982; EPRI, 1999). P.72
research reportNot linked to a paper · refsec
RESEARCH/OPERATION FINDINGS: Angled traveling screens with a fish return system have been used on the intake for Brayton Point Unit 4. Studies from 1984 through 1986 that evaluated the angled screens showed a diversion efficiency of 76 percent with latent survival of 63 percent. Much higher results were observed excluding bay anchovy. Survival efficiency for the major taxa exhibited an extremely wide range, from 0.1 percent for bay anchovy to 97 percent for tautog. Generally, the taxa fell into two groups: a hardy group with efficiency greater than 65 percent and a sensitive group with efficiency less than 25 percent (EPRI, 1999). Southern California Edison at its San Onofre steam power plant had more success with angled louvers than with angled screens. The angled screen was rejected for full-scale use because of the large bypass flow required to yield good guidance efficiencies in the test facility.
research reportNot linked to a paper · refsec
DESIGN CONSIDERATIONS: Many variables influence the performance of angled screens. The following recommended preliminary design criteria were developed in the studies for the Lake Ontario and Hudson River intakes (ASCE, 1982): Angle of screen to the waterway: 25 degrees Average velocity of approach in the waterway upstream ofthe screens: 1 foot per second Ratio of screen velocity to bypass velocity: 1:1 Minimum width of bypass opening: 6 inches
research reportNot linked to a paper · refsec
LIMITATIONS: Higher cost than the conventional traveling screen Angled screens need a stable water elevation. Angled screens require fish handling devices with independently induced flow (Richards, 1977). A-10 P.73
research reportNot linked to a paper · refsec
REFERENCES: ASCE. Design of Water TntaVe Structures for Fish Protection. Task Committee on Fish-Handling Capability of Intake Structures of the Committee on Hydraulic Structures of the Hydraulic Division of the American Society of Civil Engineers, New York, NY. 1982. Electric Power Research Institute (EPRI). Fish Protection at Cnnling Water Intakes: Stahis Report 1999. U.S. EPA. Development Document for Best Technology Availahle fnr the Tocatinn, Design,.
research reportNot linked to a paper · refsec
Construction, and Capacity of Cooling Water TntaVe Stnicnires fnr Minimizing Adverse Environmental Tmpact. U.S. Environmental Protection Agency, Effluent Guidelines Division, Office of Water and Hazardous Materials. EPA 440/1-76/015-a. April 1976.
research reportNot linked to a paper · refsec
Melville, N.Y. Chicago. December 1977. pp 415-424. A-11 P.74 Intake Screening Systems Fact Sheet No.4: Fine Mesh Screens Mounted on Traveling Screens
research reportNot linked to a paper · refsec
DESCRIPTION: Fine mesh screens are used for screening eggs, larvae, and juvenile fish from cooling water intake systems. The concept of using fine mesh screens for exclusion of larvae relies on gentle impingement on the screen surface or retention of larvae within the screening basket, washing of screen panels or baskets to transfer organisms into a sluiceway, and then sluicing the organisms back to the source waterbody (Sharma, 1978). Fine mesh with openings as small as 0.5 millimeters (mm) has been used depending on the size of the organisms to be protected. Fine mesh screens have been used on conventional traveling screens and single-entry, double-exit screens. The ultimate success of an installation using fine mesh screens is contingent on the application of satisfactory handling and recovery facilities to allow the safe return of impinged organisms to the aquatic environment (Pagano et al, 1977).
research reportNot linked to a paper · refsec
DESIGN CONSIDERATIONS: Biological effectiveness for the whole cycle, from impingement to survival in the source water body, should be investigated thoroughly prior to implementation ofthis option. This includes: The intake velocity should be very low so that if there is any impingement of larvae on the screens, it is gentle enough not to result in damage or mortality. The wash spray for the screen panels or the baskets should be low-pressure so as not to result in mortality. The sluiceway should provide smooth flow so that there are no areas of high turbulence; enough flow should be maintained so that the sluiceway is not dry at any time. A-13 P.76 The species life stage, size and body shape and the ability ofthe organisms to withstand impingement should be considered with time and flow velocities. The type of screen mesh material used is important. For instance, synthetic meshes may be smooth and have a low coefficient of friction, features that might help to minimize abrasion of small organisms. However, they also may be more susceptible to puncture than metallic meshes (Mussalli, 1977).
research reportNot linked to a paper · refsec
REFERENCES: Bruggemeyer, V., D. Condrick, K. Durrel, S. Mahadevan, and D. Brizck. "Full Scale Operational Demonstration of Fine Mesh Screens at Power Plant Intakes". In Fish Prntectinn at Steam and Hydrnelectric Power Plants EPRI CS/EA/AP-5664-SR, March 1988, pp 251-265. Electric Power Research Institute (EPRI). Fish Prntectinn at Cnnling Water Intakes: Status Repnrt 1999.
research reportNot linked to a paper · refsec
EPRI. TntaVe Technnlngies- Research Stanis Electrical Power Research Institute, EPRI GS-6293. March 1989.
research reportNot linked to a paper · refsec
Pagano, R., and W.H.B. Smith. Recent Developments in Techniques tn Prntect Agnatic Organisms at the TntaVes Steam-F.lectric Pnwer Plants MITRE Corporation Technical Report 7671. November 1977.
research reportNot linked to a paper · refsec
Sharma, R.K., "A Synthesis of Views Presented at the Workshop". In Larval F.yclusion Systems For Power Plant Cooling Water Intakes San-Diego, California, February 1978, pp 235-237. Tennessee Valley Authority (TVA). A State ofthe Art Report on TntaVe Technnlngies 1976. A-15 P.78 Passive Intake Systems Fact Sheet No. 5: Wedgewire Screens
research reportNot linked to a paper · refsec
DESCRIPTION: Wedgewire screens are designed to reduce entrainment by physical exclusion and by exploiting hydrodynamics. Physical exclusion occurs when the mesh size of the screen is smaller than the organisms susceptible to entrainment. Hydrodynamic exclusion results from maintenance of a low through-slot velocity, which, because of the screen's cylindrical configuration, is quickly dissipated, thereby allowing organisms to escape the flow field (Weisberd et al, 1984). The screens can be fine or wide mesh. The name of these screens arise from the triangular or "wedge" cross section of the wire that makes up the screen. The screen is composed of wedgewire loops welded at the apex of their triangular cross section to supporting axial rods presenting the base ofthe cross section to the incoming flow (Pagano et al, 1977). A cylindrical wedgewire screen is shown in the figure below. Wedgewire screens are also called profile screens or Johnson screens. mitre report Schematic of Cylindrical Wedgewire Screen (Pagano et al, 1977) A-16
research reportNot linked to a paper · refsec
TESTING FACILITIES AND/OR FACILITIES USING THE TECHNOLOGY: Wide mesh wedgewire screens are used at two large power plants, Eddystone and Campbell. Smaller facilities with wedgewire screens include Logan and Cope with fine mesh and Jeffrey with wide mesh (EPRI 1999).
research reportNot linked to a paper · refsec
DESIGN CONSIDERATIONS: To minimize clogging, the screen should be located in an ambient current of at least 1 feet per second (ft/sec). A uniform velocity distribution along the screen face is required to minimize the entrapment of motile organisms and to minimize the need of debris backflushing. A-17 P.80 In northern latitudes, provisions for the prevention of frazil ice formation on the screens must be considered. Allowance should be provided below the screens for silt accumulation to avoid blockage ofthe water flow (Mussalli et al, 1980).
research reportNot linked to a paper · refsec
LIMITATIONS: The physical size of the screening device is limiting in most passive systems, thus, requiring the clustering of a number of screening units. Siltation, biofouling and frazil ice also limit areas where passive screens such as wedgewire can be utilized. Because of these limitations, wedgewire screens may be more suitable for closed-cycle make-up intakes than once-through systems. Closed-cycle systems require less flow and fewer screens than once-through intakes; back-up conventional screens can therefore be used during maintenance work on the wedge-wire screens (Mussalli et al, 1980).
research reportNot linked to a paper · refsec
REFERENCES: Delmarva Ecological Laboratory. Ecological Smdies ofthe Nanticoke River and Nearby Area Vnl TT Profile Wire Smdies. Report to Delmarva Power and Light Company. 1980.
research reportNot linked to a paper · refsec
Washington, D.C, 1993. Electric Power Research Institute (EPRI). Fish Protection at Conling Water TntaVes- Status Report 1999.
research reportNot linked to a paper · refsec
Hanson, B.N., W.H. Bason, B.E. Beitz and K.E. Charles. "A Practical Intake Screen which Substantially Reduces the Entrainment and Impingement of Early Life stages of Fish". Tn Fourth Natinnal Wnrkshnp nn F.ntrainment and Impingement, L.D. Jensen (Editor). Ecological Analysts, Inc., Melville, NY. Chicago, December 1977, pp 393-407. Heuer, J.H. and D.A. Tomljanovitch. "A Study on the Protection of Fish Larvae at Water Intakes Using Wedge-Wire Screening". In Larval Exclusion Systems For Pnwer Plant Cnnling Water TntaVes R.K. Sharmer and J.B. Palmer, eds, Argonne National Lab., Argonne, IL. February 1978, pp 169-194.
research reportNot linked to a paper · refsec
Lifton, W.S. "Biological Aspects of Screen Testing on the St. Johns River, Palatka, Florida". In Passive Screen TntaVe WnrVshnp, Johnson Division UOP Inc., St. Paul, MN. 1979. A-18 P.81
research reportNot linked to a paper · refsec
Mussalli, Y.G., E.P. Taft IU, and J. Larsen. "Offshore Water Intakes Designated to Protect Fish". Journal ofthe Hydraulics Division, Proceedings ofthe America Society nf Civil Engineers. Vol. 106, No HY11, November 1980, pp 1885-1901.
journal articleNot linked to a paper · refsec
Pagano R. and W.H.B. Smith. Recent Developments in Techniques to Prntect Agnatic Organisms at the; TntaVes Steam-Electric Pnwer Plants MITRE Corporation Technical Report 7671. November 1977.
research reportNot linked to a paper · refsec
Weisberg, S.B., F. Jacobs, W.H. Burton, and R.N. Ross. Report on Preliminary Smdies Using the Wedge Wire Screen Mndel TntaVe Facility Prepared for State of Maryland, Power Plant Siting Program. Prepared by Martin Marietta Environmental Center, Baltimore, MD. 1983.
research reportNot linked to a paper · refsec
Diameter, and Thrnngh-Slnt Velncity nn F.ntrainment nf Estuarine TchthynplanVtnn Through Wedge-Wire Screens Martin Marrietta Environmental Studies, Columbia MD. August 1984. A-19 P.82 Passive Intake Systems Fact Sheet No. 6: Perforated Pipes
research reportNot linked to a paper · refsec
DESCRIPTION: Perforated pipes draw water through perforations or slots in a cylindrical section placed in the waterway. The term "perforated" is applied to round perforations and elongated slots as shown in the figure below. The early technology was not efficient: velocity distribution was poor, it served specifically to screen out detritus, and was not used for fish protection (ASCE, 1982). Inner sleeves have been added to perforated pipes to equalize the velocities entering the outer perforations. Water entering a single perforated pipe intake without an internal sleeve will have a wide range of entrance velocities and the highest will be concentrated at the supply pipe end. These systems have been used at locations requiring small amounts of water such as make-up water. However, experience at steam electric plants is very limited (Sharma, 1978). (Figure ASCE page 79). Perforations and Slots in Perforated Pipe (ASCE, 1982)
research reportNot linked to a paper · refsec
TESTING FACILITIES AND/OR FACILITIES USING THE TECHNOLOGY: Nine steam electric units in the U.S. use perforated pipes. Each of these units uses closed-cycle cooling systems with relatively low make-up intake flow ranging from 7 to 36 MGD (EEI, 1993).
research reportNot linked to a paper · refsec
RESEARCH/OPERATION FINDINGS: Maintenance of perforated pipe systems requires control of biofouling and removal of debris from clogged screens. A-20 P.83 For withdrawal of relatively small quantities of water, up to 50,000 gpm, the perforated pipe inlet with an internal perforated sleeve offers substantial protection for fish. This particular design serves the Washington Public Power Supply System on the Columbia River (Richards, 1977). No information is available on the fate ofthe organisms impinged at the face of such screens.
research reportNot linked to a paper · refsec
DESIGN CONSIDERATIONS: The design of these systems is fairly well established for various water intakes (ASCE, 1982).
research reportNot linked to a paper · refsec
York, N.Y. 1982. EFT Power Statistics Database Prepared by the Utility Data Institute for the Edison Electric Institute.
datasetNot linked to a paper · refsec
Washington, D.C, 1993. Richards, R.T. 1977. "Present Engineering Limitations to the Protection of Fish at Water Intakes". In Fourth National Workshop on F.ntrainment and Impingement, L.D. Jensen Editor, Chicago, December 1977, pp 415-424.
research reportNot linked to a paper · refsec
Sharma, R.K. "A Synthesis of Views Presented at the Workshop". In Larval Exclusion Systems For Power Plant Cooling Water Intakes San-Diego, California, February 1978, pp 235-237. A-21 P.84 Passive intake Systems Fact Sheet No. 7: Porous Dikes/Leaky Dams
research reportNot linked to a paper · refsec
DESCRIPTION: Porous dikes, also known as leaky dams or leaky dikes, are filters resembling a breakwater surrounding a cooling water intake. The core of the dike consists of cobble or gravel, which permits free passage of water. The dike acts both as a physical and a behavioral barrier to aquatic organisms and is depicted in the figure below. The filtering mechanism includes a breakwater or some other type of barrier and the filtering core (Fritz, 1980). Tests conducted to date have indicated that the technology is effective in excluding juvenile and adult fish.
research reportNot linked to a paper · refsec
However, its effectiveness in screening fish eggs and larvae is not established (ASCE, 1982). Porous Dike (Schrader and Ketschke, 1978)
research reportNot linked to a paper · refsec
TESTING FACILITIES AND/OR FACILITIES USING THE TECHNOLOGY: Two facilities which are both testing facilities and have used the technology are: the Point Beach Nuclear Plant in Wisconsin and the Baily Generating Station in Indiana (EPRI, 1985). The Brayton Point Generating Station in Massachusetts has also tested the technology. A-22 P.85
research reportNot linked to a paper · refsec
RESEARCH/OPERATION FINDINGS: Schrader and Ketschke (1978) studied a porous dike system at the Lakeside Plant on Lake Michigan and found that numerous fish penetrated large void spaces, but for most fish accessibility was limited. The biological effectiveness of screening of fish larvae and the engineering practicability have not been established (ASCE, 1982). The size of the pores in the dike dictates the degree of maintenance due to biofouling and clogging by debris. Ice build-up and frazil ice may create problems as evidenced at the Point Beach Nuclear Plant (EPRI, 1985).
research reportNot linked to a paper · refsec
DESIGN CONSIDERATIONS: The presence of currents past the dike is an important factor which may probably increase biological effectiveness. The size of pores in the dike determines the extent of biofouling and clogging by debris (Sharma, 1978). Filtering material must be of a size that permits free passage of water but still prevents entrainment and impingement.
research reportNot linked to a paper · refsec
Backflushing, which is often used by other systems for debris removal, is not feasible at a dike installation. Predation of organisms screened at these dikes may offset any biological effectiveness (Sharma, 1978). A-23 P.86
research reportNot linked to a paper · refsec
York, N.Y. 1982. EPRI. Intake Research Facilities Manual Prepared by Lawler, Matusky & Skelly Engineers, Pearl River, New York for Electric Power Research Institute. EPRI CS-3976. May 1985.
research reportNot linked to a paper · refsec
Fritz, E.S. Cooling Water TntaVe Screening Devices Used tn Reduce F.ntrainment and Impingement. Fish and Wildlife Service, Topical Briefs: Fish and Wildlife Resources and Electric Power Generation, No 9. July 1980.
research reportNot linked to a paper · refsec
Schrader, B.P. and B.A. Ketschke. "Biological Aspects of Porous-Dike Intake Structures". In Larval Exclusion Systems For Power Plant Cooling Water Intakes, San-Diego, California, August 1978, pp 5163.
research reportNot linked to a paper · refsec
Sharma, R.K. "A Synthesis of Views Presented at the Workshop". Tn Larval Exclusion Systems For Pnwer Plant Cnnling Water Intakes. San-Diego, California, February 1978, pp 235-237. A-24 P.87 Fish Diversion or Avoidance Systems Fact Sheet No. 8: Louver Systems
research reportNot linked to a paper · refsec
DESCRIPTION: Louver systems are comprised of a series of vertical panels placed at an angle to the direction of the flow (typically 15 to 20 degrees). Each panel is placed at an angle of 90 degrees to the direction of the flow (Hadderingh, 1979). The louver panels provide an abrupt change in both the flow direction and velocity (see figure below). This creates a barrier, which fish can immediately sense and will avoid. Once the change in flow/velocity is sensed by fish, they typically align with the direction of the current and move away laterally from the turbulence. This behavior further guides fish into a current created by the system, which is parallel to the face ofthe louvers. This current pulls the fish along the line ofthe louvers until they enter a fish bypass or other fish handling device at the end of the louver line. The louvers may be either fixed or rotated similar to a traveling screen. Flow straighteners are frequently placed behind the louver systems. These types of barriers have been very successful and have been installed at numerous irrigation intakes, water diversion projects, and steam electric and hydroelectric facilities. It appears that this technology has, in general, become accepted as a viable option to divert juvenile and adult fish. Top view of a Louver Barrier with Fish By-Pass (Hadderingh, 1979)
research reportNot linked to a paper · refsec