Technical Development Document for the Final Regulations Addressing Cooling Water Intake Structures for New Facilities [W-00-03-DCN-3-0002]
Other documents for the same rulemaking
References: 257 extracted, 0 linked to papers
Burns, J. M. and W. C. Micheletti. November 2000. "Comparison of Wet and Dry Cooling Systems for Combined Cycle Power Plants." Submitted as Appendix F to the comments ofthe Utility Water Act Group on EPA's Proposed Regulations Addressing Cooling Water Intake Structures for New Facilities. [DCN No. 2-038B]
Burns, J. M and W. C. Micheletti. June 2001. "Technical Review of Tellus Institute Report." Submitted as Appendix A to the comments of the Utility Water Act Group on the Notice of Data Availability; Proposed Regulations Addressing Cooling Water Intake Structures for New Facilities.
Dougherty, B.T. and S. Bernow. November 2000. "Comments on the EPA's Proposed Regulations on Cooling Water Intake Structures for New Facilities." Tellus Institute. Boston, MA. [DCN No. 2-038A]
Elliott, T. C, Chen, K., and R. C. Swanekamp. 1998. Standard Handbook of Power Plant Engineering. 2.152 2.158. New York: McGraw Hill.
GEA Thermal and Energy Technology Division. 2000. Direct Air Cooled Condenser Installations. San Diego, CA:
GEA Power Cooling Systems, Inc. Hensley, J.C. Cooling Tower Fundamentals. 2nd Edition. The Mariey Cooling Tower Company (Mission, Kansas) 1985.
Weeks, EG. www.glencanyon.net/cooling.htm Accessed May 18, 2000.
Woodruff, E.B., Lammers, H.B., Lammers, T.F. Steam Plant Operation. Seventh Edition. McGraw-Hill. New York. 1998. • 4-14 P.41 Section 316(b) TDD Chapter 5 for New Facilities Efficacy of Cooling Water Intake Structure Technologies Chapter 5: Efficacy of Cooling Water Intake Structure Technologies
CK Environmental. June, 2000. Letter from Charles Kaplan, CK Environmental, to Martha Segall, Tetra Tech, Inc. June 26, 2000. Duke Energy, Inc. April, 2000. Moss Landing Power Plant Modernization Project. 316(b) Resource Assessment. Ecological Analysts, Inc. 1979. Evaluation ofthe Effectiveness ofa Continuously Operating Fine Mesh Traveling Screen for Reducing Ichthyoplankton Entrainment at the Indian Point Generating Station. Prepared for Consolidated Edison, Inc. Edison Electric Institute (EEI). 1993. EEI Power Statistics Database. Prepared by the Utility Data Institute for the Edison Electric Institute.
Ehrler, C. and Raifsnider, C. April, 1999. "Evaluation ofthe Effectiveness of Intake Wedgewire Screens." Presented at EPRI Power Generation Impacts on Aquatic Resources Conference. Electric Power Research Institute (EPRI). 1999. Fish Protection at Cooling Water Intakes: Status Report.
EPRI. March, 1989. Intake Technologies: Research Status. Publication GS-6293.
EPRI. 1985. Intake Research Facilities Manual.
ESSA Technologies, Ltd. June, 2000. Review of Portions of NJPDES Renewal Application for the PSE&G Salem Generating Station.
Fletcher, I. 1990. Flow Dynamics and Fish Recovery Experiments: Water Intake Systems. Florida Power and Light. August, 1995. Assessment ofthe Impacts ofthe St. Lucie Nuclear Generating Plant on Sea Turtle Species Found in the Inshore Waters of Florida.
Fritz, E.S. 1980. Cooling Water Intake Screening Devices Used to Reduce Entrainment and Impingement. Topical Briefs: Fish and Wildlife Resources and Electric Power Generation, No. 9.
Hadderingh, R.H. 1979. "Fish Intake Mortality at Power Stations, the Problem and its Remedy." In: Hydrological Bulletin, 13(2-3).
Jude, D.J. 1976. "Entrainment of Fish Larvae and Eggs on the Great Lakes, with Special Reference to the D.C. Cook Nuclear Plant, Southeastern Lake Michigan." In: Jensen, L.D. (Ed.), Third National Workshop on Entrainment & Impingement: Section 316(b) - Research and Compliance. 5-20 ~cW% P.61 Section 316(b) TDD Chapter 5 for New Facilities Efficacy of Cooling Water Intake Structure Technologies
Ketschke, B.A. 1981. "Field and Laboratory Evaluation of the Screening Ability of a Porous Dike." In: P.B. Dorn and Johnson (Eds.). Advanced Intake Technology for Power Plant Cooling Water Systems.
King, R.G. 1977. "Entrainment of Missouri River Fish Larvae through Fort Calhoun Station." In: Jensen, L.D. (Ed.), Fourth National Workshop on Entrainment and Impingement.
Lifton, W.S. Undated. Biological Aspects of .Screen Testing on the St. John's River. Palatka. Florida. Mariey Cooling Tower. August 2001. Electronic Mail from Robert Fleming, Mariey Cooling Tower to Ron
Rimelman, Tetra Tech, Inc. August 9, 2001.
Micheletti, W. September, 1987. "Fish Protection at Cooling Water Intake Systems." In: EPRI Journal.
Mussalli, Y.G., Taft, E.P., and Hofmann, P. February, 1978. "Biological and Engineering Considerations in the Fine Screening of Small Organisms from Cooling Water Intakes." In: Proceedings ofthe Workshop on Larval Exclusion Systems for Power Plant Cooling Water Intakes, Sponsored by Argonne National Laboratory (ANL Publication No. ANL/ES-66).
Mussalli, Y.G., Taft, E.P, and Larsen, J. November, 1980. "Offshore Water Intakes Designated to Protect Fish." In: Journal of me Hydraulics Division, Proceedings of the America Society of Civil Engineers. Vol. 106, NoHYll. Northeast Utilities Service Company. January, 1993. Feasibility Studv of Cooling Water System Alternatives to Reduce Winter Flounder Entrainment at Millstone Units 1-3. Orange and Rockland Utilities and Southern Energy Corp. 2000. Lovett Generating Station Gunderboom
Evaluation Program. 1999. PG&E. March 2000. Diablo Canyon Power Plant. 316(b) Demonstration Report.
Pagano, R. and Smith, W.H.B. November, 1977. Recent Developments in Techniques to Protect Aquatic Organisms at the Intakes Steam-Electric Power Plants. Pisces Conservation, Ltd. 2001. Technical Evaluation of USEPA's Proposed Cooling Water Intake Regulations for New Facilities. November 2000.
Richards, R.T. December, 1977. "Present Engineering Limitations to the Protection of Fish at Water Intakes". In: Fourth National Workshop on Entrainment and Impingement.
Ringger, T.J. April, 1999. "Baltimore Gas and Electric, Investigations of Impingement of Aquatic Organisms at the Calvert Cliffs Nuclear Power Plant, 1975-1999." Presented at EPRI Power Generation Impacts on Aquatic Resources Conference.
Sharma, R.K. February, 1978. "A Synthesis of Views Presented at the Workshop." In: Larval Exclusion Systems For Power Plant Cooling Water Intakes.
Taft, E.P. April, 1999. "Alden Research Laboratory, Fish Protection Technologies: A Status Report." Presented at EPRI Power Generation Impacts on Aquatic Resources Conference.
Taft, E.P. March, 1999. PSE&G Renewal Application. Appendix F. Salem Generation Station. 5-21 P.62 Section 316(b) TDD Chapter 5 for New Facilities Efficacy of Cooling Water Intake Structure Technologies
Taft, E.P. et. al. 1981. "Laboratory Evaluation ofthe Larval Fish Impingement and Diversion Systems." In: Proceedings of Advanced Intake Technology. Tennessee Valley Authority (TVA). 1976. A State ofthe Art Report on Intake Technologies. U.S. Environmental Protection Agency (EPA), Region 4. May, 1983. 316a and 316b Finding for Cape Canaveral/Orlando Utilities Plants at Canaveral Pool.
EPA, Region 4. September, 1979. Brunswick Nuclear Steam Electric Generating Plant. Historical Summary and Review of Section 316(b) Issues. University of Michigan. 1985. Impingement Losses at the D.C. Cook Nuclear Power Plant During 1975-1982 with a Discussion of Factors Responsible and Possible Impact on Local Populations.
Versar, Inc. April, 1990. Evaluation ofthe Section 316 Status of Delaware Facilities with Cooling Water Discharges. Prepared for State of Delaware Department of Natural Resources.
Weisberg, S.B., Jacobs, F., Burton, W.H., and Ross, R.N. 1983. Report on Preliminary Studies Using the Wedge Wire Screen Model Intake Facility. Prepared for State of Maryland, Power Plant Siting Program. 5-22 P.63
DESCRIPTION: The single-entry, single-exit vertical traveling screens (conventional traveling screens) consist of screen panels mounted on an endless belt; the belt rotates through the water vertically. The screen mechanism consists of the screen, the drive mechanism, and the spray cleaning system. Most of the conventional traveling screens are fitted with 3/8-inch mesh and are designed to screen out and prevent debris from clogging the pump and the condenser tubes. The screen mesh is usually supplied in individual removable panels referred to as " baskets" or "trays". The screen washing system consists of a line of spray nozzles operating at a relatively high pressure of 80 to 120 pounds per square inch (psi). The screens are usually designed to rotate at a single speed. The screens are rotated either at predetermined intervals or when a predetermined differential pressure is reached across the screens based on the amount of debris in the intake waters. Because of this intermittent operation of the conventional traveling screens, fish can become impinged against the screens during the extended period of time while the screens are stationary and eventually die. When the screens are rotated the fish are removed from the water and then subjected to a high pressure spray; the fish may fall back into the water and become re-impinged or they may be damaged (EPA, 1976, Pagano et al, 1977). Conventional Traveling Screen (EPA, 1976) P.65
TESTING FACILITIES AND/OR FACILITIES USING THE TECHNOLOGY: The conventional traveling screens are the most common screening device presently used at steam electric power plants. Sixty percent of all the facilities use this technology at their intake structure (EEI, 1993).
RESEARCH/OPERATION FINDINGS: The conventional single-entry single screen is the most common device resulting in impacts from entrainment and impingement (Fritz, 1980).
REFERENCES: ASCE. Design of Water TntaVe Structures for Fish Protection. Task Committee on Fish-Handling Capability of Intake Structures of the Committee on Hydraulic Structures of the Hydraulic Division of the American Society of Civil Engineers, New York, NY. 1982. F.F.T Power Statistics Database Prepared by the Utility Data Institute for the Edison Electric Institute.
Washington, D.C, 1993. Fritz, E.S. Cooling Water Intake Screening Devices TTseH to Reduce F.ntrainment and Impingement Topical Briefs: Fish and Wildlife Resources and Electric Power Generation. No. 9. 1980. Jl/7 P.66
Pagano R. and W.H.B. Smith. Recent Developments in Techniques to Protect Aquatic Organisms at the Tntakes of Steam-F.lectric Power Plants. MITRE Corporation Technical Report 7671. November 1977. U.S. EPA. Development Document for Best Technology Availahle for the T.ocationJ Design ;
Construction, and Capacity of Cooling Water TntaVe Structures for Minimizing Adverse F.nvirnnmental Impact. U.S. Environmental Protection Agency, Effluent Guidelines Division, Office of Water and Hazardous Materials. EPA 440/1-76/015-a. April 1976. o?/y P.67 Intake Screening Systems Fact Sheet No. 2: Modified Vertical Traveling Screens
DESCRIPTION: Modified vertical traveling screens are conventional traveling screens fitted with a collection "bucket" beneath the screen panel. This intake screening system is also called a bucket screen, Ristroph screen, or a Surry Type screen. The screens are modified to achieve maximum recovery of impinged fish by maintaining them in water while they are lifted to a release point. The buckets run along the entire width ofthe screen panels and retain water while in upward motion. At the uppermost point of travel, water drains from the bucket but impinged organisms and debris are retained in the screen panel by a deflector plate. Two material removal systems are often provided instead of the usual single high pressure one. The first uses low-pressure spray that gently washes fish into a recovery trough. The second system uses the typical high-pressure spray that blasts debris into a second trough. Typically, an essential feature of this screening device is continuous operation which keeps impingement times relatively short (Richards, 1977;
Mussalli, 1977; Pagano et al., 1977; EPA, 1976). Modified Vertical Traveling Screens (White et al, 1976) P.68
TESTING FACILITIES AND/OR FACILITIES USING THE TECHNOLOGY: Facilities which have tested the screens include: the Surry Power Station in Virginia (White et al, 1976) (the screens have been in operation since 1974), the Madgett Generating Station in ,
Wisconsin, the Indian Point Nuclear Generating Station Unit 2 in New York, the Kintigh (formerly Somerset) Generating Station in New Jersey, the Bowline Point Generating Station (King et al, 1977), the Roseton Generating Station in New York, the Danskammer Generating Station in New York (King et al, 1977), the Hanford Generating Plant on the Columbia River in Washington (Page et al, 1975; Fritz, 1980), the Salem Genereating on the Delaware River in New Jersey, and the Monroe Power Plant on the Raisin River in Michigan.
DESIGN CONSIDERATIONS: The same design considerations as for Fact Sheet No. 1: Conventional Vertical Traveling Screens apply (ASCE, 1982).
LIMITATIONS: The continuous operation can result in undesirable maintenance problems (Mussalli, 1977). Velocity distribution across the face ofthe screen is generally very poor. Latent mortality can be high, especially where fragile species are present.
REFERENCES: ASCE. Design nf Water TntaVe Stmctures fnr Fish Protection. Task Committee on Fish-Handling Capability of Intake Structures of the Committee on Hydraulic Structures of the Hydraulic Division of the American Society of Civil Engineers, New York, NY. 1982. Electric Power Research Institute (EPRI). Fish Protection at Cooling Water TntaVes- Status Repnrt 1999.
EPRI. TntaVe Technologies- Research Stanis Electric Power Research Institute GS-6293. March 1989. U.S. EPA. Development Document for Rest Technolngy Available fnr the T.ncation, design, Cnnsrrnctinn] and Capacity nf Cooling Water TntaVe Srmchires for Minimizing Adverse F.nvirnnmental Impact. Environmental Protection Agency, Effluent Guidelines Division, Office of Water and Hazardous