Passive Samplers for Investigations of Air Quality Method Description, Implementation, and Comparison to Alternative
Other documents for the same rulemaking
References: 105 extracted, 0 linked to papers
Brown (1999), MDHS 80 (1995), ISO 16017-2 (2003), ASTM D6196-3 (2009b) http://www.perkinelmer.com/CMSResources/Images/4474181APP_IndustrialHygieneMonitoringbyTD.pdf; http://www.markes.com/; http://www.camsco.com/; http://www.sigmaaldrich.com/analyticalchromatography/air-monitoring.html
ISO 16200-2 (2000), Type B sampler; MDHS 88 (1997) http://www.shop3m.com/70070032142.html http://multimedia.3m.com/mws/mediawebserver?mwsId=SSSSSu7zK1fslxtU Mx_U4xmSev7qe17zHvTSevTSeSSSSSS—
Ultra, Ultra II, Ultra III (SKC) Badge with three different sorbent configurations (indoor: 7–11 mL/min; outdoor: 12–15 mL/min) Cassinelli et al. (1987), Guild et al. (1992) http://www.skcinc.com/prod/575-001.asp http://www.skcinc.com/prod/690-101.asp
GABIE (SKC) Badge Oury et al. (2006), Langlois (2008) http://www.skcsouthafrica.co.za/index.php?page=shop.product_details&flypa ge=&product_id=172&category_id=47&option=com_virtuemart&Itemid=60 575 (SKC) Badge with screen (9–18 mL/min)
ISO 16200-2 (2000), Type B sampler; MDHS 88 (1997) http://www.skcinc.com/reports.asp
MDHS 88 (1997) http://www.afcintl.com/industriesserved/industrial.aspx?txtSearch=*&catpageindex=8&CreatedByUser=1&Pro ductID=172 Waterloo Membrane Sampler (WMS; SiREM Labs)
PDMS (polydimethylsiloxane) membrane sampler (0.80–19 mL/min) Seethapathy and Górecki (2010a,b) http://www.siremlab.com/products/waterloo-membrane-sampler Radiello (Fondazione Salvatore Maugeri) Radial porous plastic diffusive barrier with cylinder sorbent insert (40–80 mL/min [solvent extraction diffusive body 120]; 20–30 mL/min [thermal desorption configuration, diffusive body 120-2]) Cocheo et al. (2009);
ISO 16200-2 (2000), Type D sampler; MDHS 88 (1997) http://www.radiello.com/english/index_en.html Summa canister sampling using TO-15 (U.S. EPA, 1999a) is considered by many to be a “standard” for
VI studies. Interlaboratory studies of TO-15 suggest variance in the reported values, ranging from about 30% to 300% (e.g., Lutes et al., 2012; Daugherty et al., 2004; Pearson, 2005). Studies comparing passive sampler results to TO-15 results show good agreement (30% to 90% variance) for chlorinated solvents and volatile aromatics, but poor agreement for polar compounds (e.g., Sweitzer et al., 2006; Odencrantz et al., 2008; Lutes et al., 2010; Allen et al., 2007; and Mukerjee, 2004). 3.7.3 Target Compounds Passive and conventional air sampling methods differ in the range of chemicals that can be collected and analyzed. The conventional EPA Method TO-15 is limited primarily to compounds that have sufficiently high vapor pressure to minimize condensation on the canister surface. This translates to an upper carbon range limit of approximately C12 or naphthalene. Using a multibed sorbent tube, the conventional method TO-17 can extend the compound range well beyond C12 and can be configured to collect VOCs Passive Samplers for Investigations of Air Quality Table 3. Comparison of Passive Sampler Method to Conventional Ambient Air Methods Field Ease of Analytical Sensitivity Target Compounds Sample Duration Passive single sorbent samplers Excellent Excellenta Depends on sorbent selected Hours to weeks
ASTM (American Society for Testing and Materials). 2011a. D7758 New Practice for Passive Soil Gas Sampling in the Vadose Zone for Source Identification, Spatial Variability Assessment, Monitoring and Vapor Intrusion Evaluations. ASTM International, West
Conshohocken, PA. Available at www.astm.org. 3M. 1996. 3MTM Diffusion Monitors 3500/3510/3520/3530 Storage and Recovery. Technical Data Bulletin #125. 3M Occupational Health and Environmental Safety Division. St.
ASTM (American Society for Testing and Materials). 2011b. D7663-11 Standard Practice for Active Soil Gas Sampling in the Vadose Zone for Vapor Intrusion Evaluations. ASTM International, West
Allen, M.K., D. Grande, and L. Pansch. 2007. Evaluation of passive sampling techniques for monitoring roadway and neighborhood exposures to benzene and other mobile source VOCs. Wisconsin Department of Natural Resources (WDNR) Publication AM-384 2007. WDNR,
ASTM (American Society for Testing and Materials). 2013. D6246-08 (reapproved 2013) Standard Practice for Evaluating the Performance of Diffusive Samplers. ASTM International, West
ANSI/ISEA (American National Standards Institute Inc./International Safety Equipment Association). 1998. Air Sampling Devices—Diffusive Types for Gases and Vapors in Working Environments. ANSI/ISEA 104-1998 (R2009). American National Standards
ASTM (American Society for Testing and Materials). 2009a. D4597-10 Standard Practice for Sampling Workplace Atmospheres to Collect Gases of Vapors with Solid Sorbent Diffusive Samplers. ASTM
ASTM (American Society for Testing and Materials). 2009b. D6196−03 (reapproved 2009) Standard Practice for Selection of Sorbents, Sampling, and Thermal Desorption Analysis Procedures for Volatile Organic Compounds in Air. ASTM International, West
ASTM (American Society for Testing and Materials). 2010. D6306-10 Standard Guide for Placement and Use of Diffusion Controlled Passive Monitors for Gaseous Pollutants in Indoor Air. ASTM International, West
Bartkow, M.E., J.N. Huckins, and J.F. Muller. 2004. Field-based evaluation of semipermeable membrane devices (SPMDs) as passive air samplers of polyaromatic hydrocarbons (PAHs). Atmospheric Environment 38(35):5983–5990. Available at http://www.sciencedirect.com/science/article/pii /S1352231004006454.
Begerow, J., E. Jermann, T. Keles, and L. Dunemann. 1999. Performance of two different types of passive samplers for the GC/ECD-FID determination of environmental VOC levels in air. Fresenius Journal of Analytical Chemistry 363:399–403. Available at http://link.springer.com/article/10.1007%2Fs00 2160051209.
Bohlin, P., K.C. Jones, and B. Strandberg. 2007. Occupational and indoor air exposure to persistent organic pollutants: a review of passive sampling techniques and needs. Journal of Environmental Monitoring 9:501–509. Available at http://pubs.rsc.org/en/content/articlelanding/2 007/em/b700627f/unauth.
Brown, J., and B. Shirey. 2001. A tool for selecting an adsorbent for thermal desorption applications. Supelco. Available at http://www.sigmaaldrich.com/etc/medialib/doc s/Supelco/General_Information/t402025.Par.000 1.File.tmp/t402025.pdf. Passive Samplers for Investigations of Air Quality
Brown, R.H. 1999. Environmental use of diffusive samplers: evaluation of reliable diffusive uptake rates for benzene, toluene and xylene. Journal of Environmental Monitoring 1:115–116. Available at http://pubs.rsc.org/en/content/articlepdf/1999/
Huckins. 2000. A passive integrative sampler for mercury vapor in air and neutral mercury species in water. Chemosphere: Global Change Science 2:1–9. Available at http://www.sciencedirect.com/science/article/pii /S1465997299000550. CalEPA (California Environmental Protection Agency). 2012. Advisory—Active Soil Gas Investigation. Department of Toxic Substances
Teass. 1987. Protocol for the evaluation of passive monitors, in Proceedings of Diffusive Sampling: An Alternative to Workplace Air Monitoring. Royal Society of Chemistry. London, A. Berlin, R.H. Brown and K.J. Saunders (eds.). NIOSH Protocol for the Evaluation of Passive Monitors, 190–202.
CEN (European Committee for Standardization). 1995. 838 Workplace atmospheres—Diffusive samplers for the determination of gases and vapours—Requirements and test methods. Comité Européen de
CEN (European Committee for Standardization). 2002a. EN 13528-1 Ambient air quality—Diffusive samplers for the determination of concentrations of gases and vapours—Requirements and test methods—Part 1: general requirements. European Standard. Available at http://www.bsria.co.uk/informationmembership/informationcentre/library/item/ambient-air-quality-diffusivesamplers-for-the-determination-of-conc-jan2002/.
CEN (European Committee for Standardization). 2002b. EN 13528-2 Ambient air quality— Diffusive samplers for the determination of concentrations of gases and vapours— requirements and test methods—Part 2: specific requirements and test methods. European Standard. Available at http://www.bsria.co.uk/informationmembership/informationcentre/library/item/ambient-air-quality-diffusivesamplers-for-the-determination-of-conc-jan2002-/.
CEN (European Committee for Standardization). 2003. EN 13528-3 Ambient air quality. Diffuse samplers for the determination of concentrations of gases and vapours, Part 3: guide to selection, use and maintenance. European Standard. Available at http://esearch.cen.eu/esearch/Details.aspx?id=1 0695537.
CEN (European Committee for Standardization). 2004. EN 14412 Indoor air quality. Diffusive samplers for the determination of concentrations of gases and vapours. Guide for selection, use and maintenance. British-Adopted European Standard. Available at http://shop.bsigroup.com/ProductDetail/?pid=0 00000000030075975.
CEN (European Committee for Standardization). 2005a. Ambient air quality. EN 14662-4 Standard method for measurement of benzene concentrations. Diffusive sampling followed by thermal desorption and gas chromatography. British-Adopted European Standard. Available at http://shop.bsigroup.com/ProductDetail/?pid=0 00000000030093662.
CEN (European Committee for Standardization). 2005b. Ambient air quality. EN 14662-5 Standard method for measurement of benzene concentrations. Diffusive sampling followed by solvent desorption and gas chromatography. British-Adopted European Standard. Available at http://shop.bsigroup.com/ProductDetail/?pid=0 00000000030093665. Passive Samplers for Investigations of Air Quality
Sacco, L. Zaratin, and D. Cottica. 2009. Field evaluation of thermal and chemical desorption
Crump, D., P. Harrison, and C. Walton. 2011. Aircraft Cabin Air Sampling Study: Part 1 of the Final Report. Cranfield University Institute of Environment and
Health, Bedfordshire, UK. Available at https://dspace.lib.cranfield.ac.uk/bitstream/1826 /5305/1/AircraftCabin AirSamplingStudyPart1FinalReport%2020110420. pdf.
Daughtrey, E.H., K.D. Oliver, H.H. Jacumin, and W.A. McClenny. 2004. Supplement to EPA Compendium Method TO-15—reduction of method detection limits to meet vapor intrusion monitoring needs. Presented at Symposium on Air Quality Measurement Methods and
Dietz, R.N., and E.A. Cote. 1982. Air infiltration measurements in a home using a convenient perfluorocarbon tracer technique. Environment International 8:419–433. Available at http://www.ecd.bnl.gov/pubs/BNL30797.pdf.
Feigley, C.E. and B.M. Lee. 1988. Determination of sampling rates of passive samplers for organic vapors based on estimated diffusion coefficients. American Industrial Hygiene Association 49(5):266– 269. Available at http://www.tandfonline.com/doi/abs/10.1080/ 15298668891379729?journalCode=aiha20#previe
Brinkman, M.K. O’Rourke, M.D. Lebowitz, and D.J. Moschandreas. 1999. Residential environmental measurements in the National Human Exposure Assessment Survey (NHEXAS) pilot study in Arizona: preliminary results for pesticides and VOCs. Journal of Exposure Analysis and Environmental Epidemiology 9(5):456–70. Available at http://www.nchh.org/Portals/0/Contents/ Article0173.pdf. Górecki, T., and J. Namieśnik. 2002. Passive sampling. Trends in Analytical Chemistry 21(4):276– 291. Available at http://www.sciencedirect.com/science/article/ pii/S0165993602004077.
Dietrich. 1992. Bi-level passive monitor validation: a reliable way of assuring sampling accuracy for a larger number of related chemical hazards. Applied Occupational Environmental Hygiene 7(5):310–317. Available at: http://www.tandfonline.com/doi/abs/10.1080/1 047322X.1992.10390161.
Harper, M. 2000. Sorbent trapping of volatile organic compounds from air. Journal of Chromatography A 885:29–151. Available at http://www.sciencedirect.com/science/article/pii /S0021967300003630.
Harper, M. and L.V. Guild. 1996. Experience in the use of the NIOSH diffusive sampler evaluation protocol. American Industrial Hygiene Association Journal 57(12):1115–1123. Available at http://www.ncbi.nlm.nih.gov/pubmed/8976586.
Hodny, J.W., J.E. Whetzel Jr., and H.S. Anderson II. 2009. Quantitative passive soil gas and air sampling in vapor intrusion investigations, in Proceedings of Vapor Intrusion 2009, Air & Waste Management Association, San Diego. January. Available at https://www.agisurveys.net/uploads/Quantitativ e_Passive_Sampling_for_VI.pdf. Passive Samplers for Investigations of Air Quality
ISO (International Standards Organization). 2000.
ISO (International Standards Organization). 2003.
ISO 16017-2:2003 Indoor Ambient and Workplace Air—Sampling and Analysis of Volatile Compounds by Sorbent Tube/Thermal Desorption/Capillary Gas Chromatography—Part 2: Diffusive Sampling. International Standards Organization. Available at http://www.iso.org/iso/catalogue_detail.htm?csn umber=29195.
ISO (International Standards Organization). 2007.
ISO 16000-5:2007 Indoor Air—Part 5: Sampling Strategy for Volatile Organic Compounds (VOCs). International Standards Organization. Available at http://www.iso.org/iso/catalogue_detail.htm?csn umber=37388.
Jaward, F.M., N.J. Farrar, T. Harner, A.J. Sweetman, and K.C. Jones. 2004a. Passive air sampling of
Jaward, F.M., N.J. Farrar, T. Harner, A.J. Sweetman, and K.C. Jones. 2004b. Passive air sampling of polycyclic aromatic hydrocarbons and polychlorinated naphthalenes across Europe. Environmental Toxicology and Chemistry 23(6):1355– 1364. Available at http://onlinelibrary.wiley.com/doi/10.1897/03420/abstract.