EPA. Existing Chemical Exposure Limit (ECEL) (Autoimmunity) for Occupational Use of Trichloroethylene (2021)
Other documents for the same rulemaking
References
EPA conducted a search to identify relevant NIOSH/OSHA/EPA analytical methods used to monitor for the presence of trichloroethylene in air (see Table 1). The sources used for the search included the following: 1) NIOSH Manual of Analytical Methods (NMAM); 5th Edition - URL: https://www.cdc.gov/niosh/nmam/default.html 2) NIOSH NMAM 4th Edition - URL: https://www.cdc.gov/niosh/docs/2003-154/default.html 3) OSHA Index of Sampling and Analytical Methods - URL: https://www.osha.gov/dts/sltc/methods/ 4) EPA Environmental Test Method and Monitoring Information - https://www.epa.gov/emc/epa-websites-environmental-test-method-and-monitoringinformation Table 1: Limit of detection (LOD) summary for air sampling analytical methods identified. Air Sampling Analytical Year LODa Notes Source Methods Published
NIOSH Method 8300 2016 0.43 ppm Method reports
NIOSH Method 1022, Issue 1994 60 ppb Method reports
NIOSH NMAM 4th Edition estimated LOD as 0.01 https://www.cdc.gov/niosh/d https://www.cdc.gov/niosh/d mg per sample, with a ocs/2003-154/default.html ocs/2003-154/pdfs/1022.pdf maximum sample of 30
NIOSH Method 3701, Issue 1994 0.1 ppm Method reports
NIOSH NMAM 4th Edition estimated LOD as 0.1 https://www.cdc.gov/niosh/d https://www.cdc.gov/niosh/d ppm for a 1 mL ocs/2003-154/default.html ocs/2003-154/pdfs/3701.pdf injection.
OSHA Method 1001 1999 3.7 or 18 Method reports LOD of OSHA Index of Sampling https://www.osha.gov/dts/slt overall procedure as 3.7 and Analytical Methods c/methods/mdt/mdt1001/100 ppb for charcoal tubes https://www.osha.gov/dts/slt 1.html and 18 ppb for SKC c/methods/ 575-002 Samplers.
EPA Method TO-14A 1999 14 ppb Estimated LOD based
EPA Method TO-15 1999 ≤0.5 ppb To qualify under
EPA Method TO-17 Year Published 1999 LODa Notes consistency, the LOD for this method is listed as ≤0.5 ppb. To qualify under Compendium Method