Preliminary Information on Manufacturing, Processing, Distribution, Use, and Disposal: Tetrachloroethylene (perchloroethylene)
Other documents for the same rulemaking
References
NETRATING%20LUBRICANT%20AEROSO L-BA180.pdf http://ckeinc.com/wpcontent/uploads/2016/08/CK-Punch-ItSDS-6901-A20.pdf http://ckeinc.com/wpcontent/uploads/2016/08/C-KPreserve-SDS-6869-A16.pdf http://canberracorp.com/sites/files/ms ds/husky_1229_vndlsm_stn_rmvr.pdf https://www.certifiedlabs.in/MSDS/SAF -SOL.pdf http://www.staffelectric.com/wpcontent/uploads/2012/02/11-SAF-SOL20-20.pdf http://championbrands.com/MSDS/412 6.pdf http://championbrands.com/MSDS/412 6AN-D%20SDS.pdf http://www.chaseproducts.com/msds/ 4385159.pdf http://cdn.chemservice.com/product/ msdsnew/External/English/N13532%20English%20SDS%20US.pdf http://cdn.chemservice.com/product/ msdsnew/External/English/MCLPVOL3M5%20English%20SDS%20US. http://www.chemaxmil.com/TXMAS/M
SDS/MSDS-A114-Blast-It.pdf Trade Name Use of the Product % by weight of chemical Dielectric Encapsulator Moisture and condensation displacer Safety Lube 2000
DS/MSDSheets/MIscellaneous/SDS%20 DC%20GRADE%20PERC.pdf https://pass.partsmaster.com/MSDS/62 28.pdf https://www.perkinelmer.com/Content /MSDSDatabase/MSDS_N9307036_AU_ (EN).pdf http://www.neverseezproducts.com/m sds/81082.pdf http://www.piercechemical.com/wpcontent/uploads/2016/05/ChlorasanSDS-PW0418500.pdf http://www.piercechemical.com/wpcontent/uploads/2016/05/Dry-HairCleaner-SDS-PW0410500.pdf http://www.piercechemical.com/wpcontent/uploads/2016/05/SaniSpraySDS-PW0417000.pdf http://www.ppe.com/msds/BMR016_01_00_MSDS_English.pdf http://www.ppe.com/msds/MCB01.PDF http://www.plewsedelmann.com/assets/1/7/12092TF_SD S.pdf http://www.plusco.com/products_safety_data_sheet/pl usco004-industrial-productssafetysolvent-spray.pdf http://www.plusco.com/products_safety_data_sheet/pl usco009-industrial-products-piercepenetrating-lubricant.pdf https://www.menards.com/msds/1035 51_001.pdf https://www.grandandtoy.com/corpora tepages/PlayVendorMSDS.aspx?sku=76 0007701 http://procheminc.com/proddocs/KNO
VAN-MRK-RMR-ACS.pdf http://www.seymourpaint.com/wpcontent/uploads/2014/02/6201526.pdf http://www.officedepot.com/pdf/msds /292039.pdf http://plating.sifcoasc.com/Asset/MSD S-TUFF-MASK.pdf http://www.spexcertiprep.com/MSDS/
TS-VLR Vinyl letter remover 4-12% Cera Fluida Classic Brightener wax for natural stones 11/5/2011 B900, Berkebile Electric Contact Cleaner Electrical cleaner >95% Berkebile 2+2 Clean Brake Automotive - Brake cleaner 100% Berkebile Oil 2+2 Tire Inflator Instantly inflate and seal tires 30-40% Hypalon Coating Cableguard walk surface topcoat San Veino Spray Embalming and preserving mixture 67.90% E1009 Restore Black Battery Reconditioner Coating Penray Electric Motor Cleaner Electrical cleaner 60-100% Service Pro Chlorinated Brake
US&C003=E&C013=1001620&C123=SD http://steinsinc.com/MSDS/Misty/ICS% 20Energized%20Electrical%20Cleaner.p http://webfiles.acuitysp.com/msds/030 7_1_EN1_CDN.PDF http://associatedfuelsystems.com/wpcontent/uploads/2014/05/PartsCleaner-SDS-003601.pdf http://zep45.com/wpcontent/uploads/2014/06/Zep45_MSD S_ENG.pdf Trade Name Use of the Product % by weight of chemical A00391 MST MOISTURE GUARD 16net15 Lubricant >70-<90%
US&C003=E&C013=1047961&C123=SD http://www.cityofmenashawi.gov/COM/Health/MSDS/Zep%20XOut%20ll%20Carpet%20Cleaner.pdf http://associatedfuelsystems.com/wpcontent/uploads/2014/04/Formula300-SDS.pdf https://sds.zepinc.com/ehswww/zep/re sult/direct_link.jsp?P_LANGU=E&P_SYS =2&P_SSN=11337&C001=MSDS&C002=
US&C003=E&C013=1040604&C123=SD http://associatedfuelsystems.com/wpcontent/uploads/2014/05/Zep-EraseAerosol-SDS.pdf https://sds.zepinc.com/ehswww/zep/re sult/direct_link.jsp?P_LANGU=E&P_SYS =2&P_SSN=11337&C001=MSDS&C002=
Flexament, furniture polish, gasket remover, shoe waterproofing, gun oil, shoe adhesive, spray snow, windshield cleaner. http://events.awma.org/education/Presentations/Session%208/3_AF_AWMA_IA_09272010_EMD. Fabric protector spray (discontinued). http://webforms.sgs.com/v4/corp/safeguards/pdf/PRODUCT%20RECALLS-Consumer%20ProductsOctober-16-31.pdf Used in the coal industry to determine the specific gravity of the various fractions of a sample provided by the /coal/ mine. In Australia, an estimated 26 tonnes of perchloroethylene per year is used in the coal industry. http://tools.niehs.nih.gov/cebs3/ntpviews/index.cfm?action=testarticle.properties&cas_number=1 27-18-4; https://www.nicnas.gov.au/__data/assets/word_doc/0019/34822/PEC15tetrachloroethylene.docx Formerly used, but no longer approved, in mixtures with grain protectants and certain liquid grain fumigants. [Farm Chemicals Handbook 87. Willoughby, Ohio: Meister Publishing Co., 1987., p. C-248] (From
HSDB database) Page 32 of 38 6. Disposal of Waste and Recycling/Recovery Recycling and Recovery The following recycling and recovery information is from a 1985 EPA risk assessment. The figure below is a process flow diagram for the solvent recovery of perchloroethylene. Solvents are stored both before and after reclamation in containers ranging in size from 55-gallon drums to 20,000-gallon tanks. Waste solvent can be piped or leaded manually into process equipment. Initial treatment includes vapor recovery or mechanical separation. Vapor recovery operations include condensation, adsorption, and absorption. Mechanical recovery operations include decanting, filtering, draining, settling, and centrifuging. Distillation methods include batch, continuous, or steam distillation. After distillation, the solvent is purified. During purification, water is removed by decanting or salting. During purification, special additives are added to renew the solvent. Waste materials are disposed of by incineration, landfilling, or deep well injection. Emission points for perchloroethylene include storage tank vents, condenser vents, incinerator stacks, and fugitive losses.
EPA, Occupation Exposure and Environmental Release Assessment of Tetrachloroethylene. Figure 1. Process flow diagram for the solvent recovery of perchloroethylene (1985).
TRI includes on-site solvent recovery (including distillation, evaporation, fractionation or extraction) and other recovery or reclamation for reuse. http://www.epa.gov/tri Page 33 of 38 Disposal of Waste Under the Resource Conservation and Recovery Act (RCRA), perchloroethylene is a listed hazardous waste. See 40 CFR 261.33 - Discarded commercial chemical products, off-specification species, container residues, and spill residues thereof. One method of disposing perchloroethylene involves absorption in vermiculite, dry sand, earth, or a similar material and then burial in a secured sanitary landfill (HSDB 2013). A second method involves incineration after mixing with another combustible fuel. With the latter method, combustion must be complete to prevent the formation of phosgene, and an acid scrubber must be used to remove the haloacids produced. The gas-fired type of incinerator is optimal for the total destruction of perchloroethylene (HSDB 2013). https://www.atsdr.cdc.gov/toxprofiles/tp18-c5.pdf
HSDB. 2013. Tetrachloroethylene. Hazardous Substances Data Bank. National Library of
Medicine, http://toxnet.nlm.nih.gov. May 09, 2013. Perchloroethylene is also a potential candidate for fluidized bed incineration at 450–980°C, rotary kiln incineration at 820–1,600°C, and liquid injection incineration at 650–1,600°C (HSDB 2013). Federal regulations prohibit land disposal of various chlorinated solvent materials that may contain perchloroethylene. Any solid waste containing perchloroethylene must be listed as a hazardous waste unless the waste is shown not to endanger the health of humans or the environment (EPA 1985b, 1988). Destruction and removal efficiency of perchloroethylene that is designated as a principal organic hazardous constituent must be 99.99%. https://www.atsdr.cdc.gov/toxprofiles/tp18-c5.pdf
WHO. 1987. Tetrachloroethylene health and safety guide. World Health Organization, Distribution and Sales 1211 Geneva 27, Switzerland, 32.
Medicine, http://toxnet.nlm.nih.gov. May 09, 2013. According to TRI, in 2015, 1,170,581 pounds of perchloroethylene were transferred offsite to landfills and/or other treatment/disposal facilities and 791,156 pounds were released to air, water, or land.