Damage Case Compendium, Volume III: Rejected Damage Cases - DCN SE04462
Other documents for the same rulemaking
References: 248 extracted, 0 linked to papers
U.S.C. 9604(e), August 27, 2009. Accessed Online March 2013. http://www.epa.gov/waste/nonhaz/industrial/special/fossil/surveys/basin-elect2.pdf
GEI (2011): Specific Site Assessment for Coal combustion Waste Impoundments at Basin Electric Antelope Valley Station, Beulah, North Dakota, GEI Project 092884, March 2011. Accessed Online March 2013. http://www.epa.gov/waste/nonhaz/industrial/special/fossil/surveys2/basin-antelope-final.pdf Croft (1973): Ground-Water Resources, Mercer and Oliver Counties, North Dakota, M.G. Croft, U.S. Geological Survey; County Ground Water Studies 15 – Part III, North Dakota State Water Commission, and Bulletin 56 – Part III, North Dakota Geological Survey. Accessed Online January 2013. http://www.swc.nd.gov/4dlink9/4dcgi/GetSubContentPDF/PB-301/MercerOliver_Part_3.pdf Carlson (1973): Geology of Mercer and Oliver Counties, North Dakota, C. G. Carlson, North Dakota Geological Survey, Grand Forks, North Dakota, 1973. Bulletin 56 — Part I, North Dakota Geological
Survey, County Ground Water Studies 15 — Part I, North Dakota State Water Commission. Accessed Online January 2013. http://www.swc.nd.gov/4dlink9/4dcgi/GetSubContentPDF/PB-297/MercerOliver_Part_1.pdf
EPA Minefill Site visit (2001): U.S. EPA Site Visit Report Coal Combustion Waste Minefill Management Practices - North Dakota - Draft Final Report, December 11, 2002. Accessed Online April 2013. http://www.epa.gov/waste/nonhaz/industrial/special/fossil/sites/nd-visit.pdf
IEL landfill is filled with coal ash from industrial boilers in the Akron/Canton area. This represents an estimated 450-acre feet of coal ash totaling up to about 1 million tons. According to EIP (2010a), USEPA’s remedial actions at the IEL landfill have focused almost exclusively on contamination by volatile organic chemicals (VOCs), and no mention is made in documents posted on USEPA Region 5’s website that CCR was a significant source of groundwater contamination by metals at the site (USEPA Region 5, 2010).
EIP (2010a) presents evidence, which supports the conclusion that coal ash at the IEL site is either exclusively or the predominant source of the extensive metals contamination documented at the site. According to Jackson et al., (1989) the till layer has an effective permeability of 1 x 10 -6 cm/sec. For the spatial relations among the three aquifers, see Jackson et al., (1989), Figure 9.
However, according to a July 29, 2004 report: Review of Hydrogeologic & Other Site Documentation Industrial Excess Landfill (IEL) Superfund Site, Uniontown, Ohio, P.E. LaMoreaux & Associates, Inc. (http://www.epa.gov/region5/cleanup/iel/pdfs/iel_ombudsman_report_20040929.pdf), following a revised interpretation of flow conditions by Sharp & Associates, Inc. after the elimination of several monitoring points, the area of mounding no longer existed and the flow pattern was consistently from east to west across the site, and then turning northwesterly in the area of the bedrock valley.
However, it is also important to recognize that groundwater flow and recharge conditions during the time of waste placement were likely much different than what occurs ‘today’ (namely, 2004). Before the final soil cover was added in 1980, the open pit landfill would have served as a local recharge area for the shallow groundwater system. At that time, it is possible that localized mounding of groundwater beneath the landfill was occurring due to increased infiltration of surface water into the aquifer. This recharge could have acted as a flushing mechanism to
EIP (2010a) claims that levels of antimony, arsenic, barium, beryllium,
ATSDR (1989). For a full list of chemicals detected in the site’s surface soils, see EPA ROD (1987), Tables 3, 4, and 5. According to EIP (2010a) and the EarthJustice comment to the proposed CCR rule’s docket (EPA-HQ-RCRA2009-0640-6315), metals where drinking water standards have been exceeded (maximum exceedances in parentheses) include: antimony (52 times the federal standard), arsenic (13 times the federal standard), beryllium (30 times the federal standard), cadmium (53 times the federal standard), chromium (17 times the federal standard), lead (47 times USEPA’s action level), thallium (6.5 times the federal standard), and nickel (12.4 times USEPA’s former
MCL). In 1987 USEPA required 100 homes west of the site to be provided with free public water. Yet despite the
OH EPA’s assertion that metal concentrations were rising in contaminant plumes from the site in the mid-1990s,
USEPA determined that this cleanup remedy was complete in 2005 without remediating contamination flowing from the landfill to the north and south into neighborhoods. EarthJustice (ibid) claims that wells located as far as 1,000 feet offsite to the north have had exceedances of MCLs for cadmium, chromium, lead, selenium, and thallium in samples collected from 1997 to 2001, yet 19 monitoring wells were decommissioned in 2004, including eight where exceedances have occurred in residential areas not provided with public water. In fact, analysis for metals was stopped at all remaining monitoring wells in 2004. Residents in these areas who cannot afford a hook-up fee continue to use private wells and face potentially daily exposure to high levels of toxic metals.
EPA (2004). III. CCR Rejected Damage Cases or other health-based standards measured in groundwater at sufficient distance from the waste management unit to indicate that hazardous constituents have migrated to the extent that they could cause human health concerns December 2014 Onsite groundwater exceeded primary MCLs for antimony, arsenic, barium, beryllium, chromium, lead, mercury, nickel, radium, and thallium. Criterion 2: Where a scientific study provides The surrounding neighborhoods have shown a high cancer incidence rate and one neighborhood has reported documented evidence of another type of cancer in nearly every home. damage to human health or the environment (e.g., ecological damage) The EPA added the site to the NPL as a Superfund site in 1986. administrative ruling or court decision with an
Environment, Thirty-nine New Damage Cases of Contamination from Improperly Disposed Coal Combustion Waste, Environmental Integrity Project, Earthjustice and Sierra Club, August 26, 2010. http://www.environmentalintegrity.org/news_reports/08_26_10.php
Appendix C, Case #25. ICF, October 2010. US EPA Region 5 (No date): US EPA Region 5 Cleanup Sites. Accessed Online March 2013. http://www.epa.gov/Region5/sites/iel/index.htm Jackson et al., (1989): Hardy Road Landfill and Industrial Excess Landfill, A Superfund Site, Jim L.
OH EPA comments to the CCR proposal (EPA-HQ-RCRA-2009-0640-8226) and the 2011 NODA (EPA-HQRCRA-2011-0392-0163) dockets.
USWAG’s comment to the 2011 NODA docket (EPA-HQ-RCRA-2011-0392-0211), November 14, 2011: “This case does not meet the criteria for a CCR damage case because the alleged environmental damage at the site was not tied to CCRs. The damage allegations are for a non‐utility, third‐party site containing mixed waste with an estimated one‐third of the landfill volume attributable to CCRs. The alleged damage was largely a result of other non‐CCR waste management activities. There are multiple responsible parties for the site including industrial facilities that utilized the IEL for disposal of millions of tons of mixed chemical and industrial waste. This site received mixed industrial wastes, fly ash, and general public wastes from multiple responsible parties. Industrial facilities utilized the landfill for disposal of millions of tons of mixed chemical and industrial waste. Off‐site impacts to groundwater have not been attributed by USEPA to any one waste source in the landfill. CCRs were from non‐utility company sources and constituted an estimated one‐third of landfill volume versus two‐thirds of volume being from chemical wastes, hospital wastes, and other sources. An on‐site lagoon for industrial organic chemical wastes also operated at the landfill site.”
Studies, The University of Akron. Ohio Journal of Science Vo. 89 (3), pages 45-55, 1989. Accessed Online March 2013. https://kb.osu.edu/dspace/bitstream/1811/23315/1/V089N3_045.pdf
ATSDR. 1989. Public Health Assessment for Industrial Excess Landfill Uniontown, Stark County, Ohio
CERCLIS No. ODD000377911, July 21, 1989. Accessed Online March 2013. http://www.atsdr.cdc.gov/HAC/pha/IndustrialExcessLandfillOhio/IndustrialExcessLandfill07211989.pdf
EPA (2010): Superfund Third Site Progress Profile: Industrial Excess Landfill. Accessed Online March 2013. http://cfpub.epa.gov/supercpad/cursites/csitinfo.cfm?id=0504014#ContamExp
USEPA Region 5 (2010): IEL Superfund Site. Accessed Online March 2013. http://www.epa.gov/Region5/sites/iel/index.htm.
EPA ROD (1987): EPA Superfund Record of Decision: Industrial Excess Landfill, EPA ID: OHD000377911, OU 02, Uniontown, OH, 09/30/1987. EPA/ROD/R05-87/056, 1987. Accessed Online March 2013. http://www.epa.gov/superfund/sites/rods/fulltext/r0587056.pdf
EPA ROD (1989): EPA Superfund Record of Decision: Industrial Excess Landfill, EPA ID: OHD000377911, OU 01, Uniontown, OH, 07/17/1989. EPA/ROD/R05-89/098, 1989. Accessed Online March 2013. http://www.epa.gov/superfund/sites/rods/fulltext/r0589098.pdf
EPA ROD Amendment (2000): EPA Superfund Record of Decision Amendment: Industrial Excess
Landfill, EPA ID: OHD000377911, OU 01, Uniontown, OH, 03/01/2000. EPA/AMD/R05-00/162, 2000. Accessed Online March 2013. http://www.epa.gov/superfund/sites/rods/fulltext/a0500162.pdf
EPA ROD Amendment (2002): EPA Proposes Amendment to the Cleanup Plan for Industrial excess
Landfill, Uniontown, Ohio, April 2002. Accessed Online March 2013. http://www.epa.gov/region5/cleanup/iel/pdfs/iel_fs_proposed_plan_200204.pdf
EPA (2004): Samples near IEL Site Show Only ‘Background’ Radiation. Industrial Excess Landfill Site,
Uniontown, Ohio, April 2004. Accessed Online March 2013. http://www.epa.gov/region5/cleanup/iel/pdfs/iel_fs_200404.pdf R11. Boardman Plant – Portland General Electric (PGE), Boardman, Morrow County, Oregon Type: Landfill, Cooling Water Reservoir and Wastewater Ponds. Background and Description: The Boardman Plant, located in Boardman, Oregon, has received CCRs from the Portland General Electric Company (PGE) since the mid-1970s.169 The site contains several The Boardman Power Plant (BPP) is a nominal 550-megawatt coal fired electric generating facility located on Tower Road in northern Morrow County. The original Site Certificate for the Boardman Power Plant was executed on March 24, 1975. The Boardman Plant was placed into service on August 3, 1980. The Plant uses annually over 2.5 million tons of low‐sulfur, sub‐bituminous coal from the Powder River Basin (Lewis et al., 2012).
III. CCR Rejected Damage Cases December 2014 reservoir are screened in this perched Pomona Basalt zone. Well 130, located at the industrial waste evaporation ponds to the north, is screened in the shallow Elephant Basalt formation above the Pomona Basalt and PGE reports that it is too dry to sample. The main groundwater aquifer occurs 350 feet below the plant in the Columbia River Basalt formation. The deepest well at the Boardman Plant is 108 feet deep, and the average depth of wells that produce water is 81 feet. Thus the deeper Columbia River Basalt regional aquifer is not monitored for any effect from the plant operations. Impact: EIP (2010a) indicates that levels of arsenic exceeded the primary EPA Maximum Contaminant Level (MCL) in onsite groundwater. Additionally, total dissolved solids (TDS) exceeded the secondary
Environment, Thirty-nine New Damage Cases of Contamination from Improperly Disposed Coal Combustion Waste, Environmental Integrity Project, EarthJustice and Sierra Club, August 26, 2010. http://www.environmentalintegrity.org/news_reports/08_26_10.php
ICF (2010). USWAG’s comment to the 2011 NODA docket (EPA-HQ-RCRA-2011-0392-0211), November 14, 2011: “This case does not meet the criteria for a damage case because the allegations do not contain any documented evidence of off‐site groundwater monitoring data or off‐site groundwater monitoring data showing exceedances of specified health‐based criteria.”
Appendix C, Case #28. ICF, October 2010.
ODOE (2010): Oregon Department of Energy, Energy Facility Site Certificate for Boardman Coal Plant, 2010. Accessed Online March 2013. http://www.oregon.gov/ENERGY/SITING/BCP.shtml Lewis et al., (2012): Using Closed-loop Biomass to Displace Coal at Portland General Electric’s Boardman Power Plant: Carbon Implications, Mark Lewis, Manuel Garcia-Perez, Bill Pan, Don Horneck, Don Wysocki, and Robert Bass, University of Washington, Washington State University, Oregon State
NOx, a dry scrubber to reduce SO2, and a new baghouse to improve particulate control) at the BSP within up to five years, to comply with regulations to limit air pollutants that cause haze in the Boundary Waters Canoe Area Wilderness (https://www.otpco.com/NewsInformation/NewsReleases/Pages/Notice201252115435.aspx). Immediately to the south of the BSP is Poet Biorefining - Big Stone. Poet Biorefining has been operating since June 2002 to produce annually (since 2007) 79 million gallons of ethanol (http://www.poetenergy.com/bigstone). BSP supplies the Poet plant with process steam as well as other support services including water for fire protection and process water and rail system. According to South Dakota Department of Environmental Resources’ (SD DENR) comment to the proposed
CCR Rule’s docket (http://www.uswag.org/pdf/2010/CCR%20Comments/SDDENR112010.pdf), the small boiler slag sluice pond, located west of the Existing Brine Pond, is used for the temporary storage of slag until the slag is removed and dried prior to being shipped offsite for recycling or hauled in dry form to the nearby dry tomb landfill. According to SD DENR (Undated), the two lime drying beds are located approximately 150 yards southwest of the power plant and southeast of the coal stockpile area. The lime sludge drying beds were constructed using clay soils, but not to any specific compaction or seepage requirement.
III. CCR Rejected Damage Cases December 2014 an under drain collection system,183, 184 and an inert construction/ demolition debris landfill. The following three process-water ponds, associated with the BSP’s closed-cycle cooling system:185 Cooling
III. CCR Rejected Damage Cases December 2014 The glacial till hosts the Veblen aquifer, which occurs in eastern Grant County, the northern and eastern portions of Roberts County, and Marshall County.191 The Veblen aquifer, under artesian conditions in most areas, shows a significant spatial variability concerning its thickness and hydraulic properties. In some areas close to the BSP, where the aquifer is at or near land surface, it is under water-table conditions. 192, 193 Recent exploratory drilling has encountered till variants with distinct hydraulic properties underneath a thick-clay till with lenses of gravel, sand and silt, which serves to confine the aquifer.194 The regional discharge is toward the Minnesota River/Big Stone Lake located east of the BSP and the Whetstone River to the south. However, the potentiometric map of the shallow Veblen aquifer demonstrates that the ESP’s extensive pond areas exert a large influence on local flow directions:195 the Cooling Pond is associated with 25 feet of shallow aquifer groundwater mounding, the Evaporation Pond – with 10 feet of mounding, and 20 feet of groundwater mounding occurs in the shallow aquifer south and southeast of the Holding Pond.
EIP (2010a) claims that the localized mounding invokes substantial leakage through the bottom of each pond. According to the Utility, 196 groundwater moves relatively slowly in the clay till and the overall potential for horizontal migration is relatively low. Groundwater levels show very little correlation with average monthly rainfall indicating that most precipitation results
TDS concentration averages 1,300 mg/L, and Hardness averages 860 mg/L.197 Impact and Damage Claims: EIP (2010a) indicates that a review of recent (2007-09) onsite monitoring records found groundwater contamination in 21 of 25 monitoring wells which screen the shallow and intermediate sub-aquifers.
EIP (2010a) indicates that arsenic and lead were both found in multiple wells above the primary EPA Maximum Contaminant Level (MCL), most commonly in wells near the brine ponds.
EIP (2010a) also notes boron above the EPA Lifetime Health Advisory in eight wells, and sulfate, chloride, and total dissolved solids (TDS) above the secondary EPA MCLs (SMCLs) Hansen (1990, Figure 16), and Gilbertson (1996). According to Hansen (1990), and as validated by recent hydrologic studies associated with the now abolished
BSP II Project (U.S. DOE EIS, 2009), the aquifer’s surface exposure takes place in T. 120 N., R. 47 W. and the southern part of T. 121 N., R. 46 and 47 W, near the North and South Forks of the Whetstone River. According to Hansen (ibid, Table 3), the Veblen aquifer has the following physical characteristics: average thickness: 28 feet; average depth below land: 52 feet (range: 1-210 feet); average groundwater level below land surface: 29 feet (range: 1-81 feet); and range of reported well discharge: 10-50 gallons/minute. According to U.S.
DOE EIS, (2009), groundwater monitoring conducted at the BSP site since 1971 indicates that groundwater occurs at the BSP’s area generally between 40 to 60 feet BGS. U.S. DOE SDEIS (2007, Figure 3.3-3) and U.S. DOE EIS (2009, Section 3.2.2.1). Two recently drilled wells encountered fine and medium sands associated with a ground moraine, with hydraulic conductivity of 21 feet/day, and gravely sand associated with a terminal moraine, with hydraulic conductivity of 157 feet/day.
Barr (2010): Figure 2 portrays an October 2009 potentiometric photo-map.
Ibid, narrative and Figures 2 and 3. Based on nine well data, additional constituents include sodium (65 mg/L on average), iron (2.6 mg/L), manganese (0.42 mg/L), bicarbonate (420 mg/L), and chloride (22 mg/L). For the full range of compositions, see Hansen (1990), Table 6.
III. CCR Rejected Damage Cases December 2014 in a number of wells. Strontium was also found in two wells above the EPA Lifetime Health Advisory.198,
EIP (2010a) notes that SD DENR officials insist contamination comes from water softener in the brine wastes.