MW (1985). 11,600 tons of washed-coal (11,700 BTU/lb) are rail-delivered daily, primarily from mines in western Kentucky and southern Illinois. The Seminole Generating Station is permitted to burn up to 30 percent of its fuel as petroleum coke (petcoke). Actual amounts burned depend on the price and availability of petcoke, and plant conditions (http://www.seminole-electric.com/pdf/seminole_generating_station_1.pdf). On September 5, 2008, the
FDEP issued final air construction Permit to install the 750 MW, coal and petcoke-fired Unit 3 adjacent to existing Units 1 and 2 (FDEP Division of Air Resource Management (2009). However, in mid-December 2009, Seminole Electric Cooperative announced that it was canceling the 750 MW coal fired power plant project “because of regulatory and legal uncertainties over the future of coal“. Roughly 550,000 tons per year of synthetic gypsum from SGS’ wet scrubber are delivered annually by conveyor to Lafarge’s drywall manufacturing plant, opened in 2001 adjacent to SGS. Lafarge uses the synthetic gypsum to produce about 900 million square feet of wallboard each year (http://www.powermag.com/coal/Top-PlantsSeminole-Generating-Station-Palatka-Florida_2181_p2.html). According to FDEP’s comment to the October 2011 NODA docket: EPA-HQ-RCRA-2011-0392-0285, the process water ponds and stormwater ponds in the landfill area are lined with a geomembrane liner to stop the leakage to groundwater. A liner has been installed over an expanded portion of the FGD landfill “and is expected to be put into operation soon.” For description of the SGS site’s geology and subsurface hydrology, see Seminole Electric Cooperative (2006), Vol. 1, Section 2, particularly pp. 2-15 to 2-18.
EIP (2010). Cited in EarthJustice’s comment to the 2007 NODA: EPA-HQ-RCRA-2006-0796-0446. Also, FDEP (2012). IIb Potential CCR Damage Cases
PART I (Cases 1-32) December 2014 these constituents (including chloride, sulfate, total dissolved solids - TDS, boron, and iron) were detected up to one mile from the FGD landfill at concentrations exceeding FDEP Groundwater CTLs. Surface water data showed boron at over x1000 its guidance concentration. Surface water data also revealed exceedances for aluminum at x 4,100 the Class III fresh surface water Cleanup Target Levels (CTLs). In addition, there are SMCL exceedances in surface water for chlorine (over x30), sodium (over x3), sulfate (over x3) and TDS (over x8.5), and historical surface water data also exceeded s for boron and arsenic.
FDEP’s comment to the proposed CCR rule docket: EPA-HQ-RCRA-2006-0796-0460 and FDEP’s comment to the October 2011 NODA docket: EPA-HQ-RCRA-2011-0392-0285. Also, Florida Electronic Power Coordinating
Group, Inc. (FCG), EPA-HQ-RCRA-2009-0640-10498 and Seminole Electric Cooperative, Inc., EPA-HQ-RCRA2009-0640-10497. These arguments were seconded by FDEP in its comment to the proposed Rule docket: EPA-HQRCRA-2009-0640-6846.
Namely, Florida Statutes Chapter 403 and the groundwater protection standards provided in Chapter 62-520 Florida Administrative Code. The RAP requires the collection of groundwater from the surficial aquifer near the FGD landfill that is fed back into the power plant process. Comment to the proposed CCR rule docket: EPA-HQ-RCRA-2009-0640-10497. IIb Potential CCR Damage Cases
PART I (Cases 1-32) December 2014 wetland impacts were limited to stressed vegetation located on Seminole property. Ongoing monitoring activities demonstrate that the on-site vegetation diversity and density is improving due to a number of
EIP (2010): Out of Control: Mounting Damages from Coal Ash Waste Sites, Thirty-one New Damage Cases of Contamination from Improperly Disposed Coal Combustion Waste, Case #3. Environmental Integrity Project and Earthjustice. February 24, 2010.
PART I (Cases 1-32) December 2014 http://www.environmentalintegrity.org/news_reports/news_02_24_10.php
Appendix B, Case #3. ICF, 10/2010.
FDEP (2012): Solid Waste Enforcement and Compliance Documents, Monitoring Plans and Documents
Related, Seminole Electric Cooperative, Florida DEP web site. Accessed Online November 2012. http://appprod.dep.state.fl.us/WWW_WACS/REPORTS/SW_Facility_Docs.asp?wacsid=94790
FDEP Division of Air Resource Management (2009): Technical Evaluation and Preliminary
Management, Bureau of Air Regulation, New Source Review Section, June 12, 2009. Accessed Online November 2012. http://www.dep.state.fl.us/air/emission/construction/seminole/TechnicalMACT.pdf Seminole Electric Cooperative (2006): Site Certification Application, Seminole Generating Station Unit 3, Palatka, Florida, Volumes I to III. Golder Associates, Inc., Tampa, Florida, March 2006. Accessed Online November 2012 (No-longer accessible). http://www.usda.gov/rus/water/ees/pdf/seminole_sitecert_vol1_0306.pdf http://www.usda.gov/rus/water/ees/pdf/seminole_sitecert_vol2_0306.pdf http://www.usda.gov/rus/water/ees/pdf/seminole_sitecert_vol3_0306.pdf PTb09. Joliet Generating Station 9 – Lincoln Stone Quarry Landfill, Midwest Generation,
Joliet, Will County, Illinois145 Type: ‘Landfill’ (Actually, a Slurried CCR Receptacle and a Settling Pond in a Former Quarry) and Two Surface Impoundments. Background and Description: Midwest Generation (under parent company Edison International) operates the Joliet 9 and Joliet 29 generating stations,146 which have been disposing of coal combustion residual (CCR) in the Lincoln Stone Quarry (LSQ) landfill since 1962. The quarry operates under a landfill permit;147 however, the site also includes two below-grade surface impoundments for the slurry In March 2014, a federal bankruptcy court judge approved the sale of all assets and operating companies of Edison Mission Energy -- parent of Midwest Generation, to NRG Energy Inc.: http://www.chicagotribune.com/business/breaking/chi-midwest-generation-nrg-energy-20140311-story.html Both plants are located approximately 40 miles southwest of Chicago. Based on Midwest Generation’s 2008 Annual report (http://www.sec.gov/Archives/edgar/data/1134016/000104746909002059/a2190917z10-k.htm), the operating units comprising the Joliet Station are referred to as Units 6, 7 and 8. Units 6, 7 and 8 came on line in 1959, 1965 and 1966, respectively. Joliet Unit 6 (also known as Joliet Generating Station 9) is a 290 MW coal-fired unit located southeast of and across the Des Plaines River from Joliet Units 7 and 8 (1601 South Patterson Rd.,
However, in areas where its top has been affected by erosion, the thickness is variable, and frequently, much less. According to Figure 22 in Visocky et al., (1985), the thickness of the glacial deposits in the Plant’s area is less than 200 feet. Visocky et al., (ibid). IIb Potential CCR Damage Cases
PART I (Cases 1-32) December 2014 Boyd Quarry immediately east of the LSQ landfill raised concerns that groundwater would also begin flowing east, to this quarry and northeast, toward a residential area.153 This concern led IEPA to deny
BRP’s application for an NPDES permit. Impact and Damage Claims: According to EIP (2011a) and Stant and Barkley (2011), CCR from Joliet 9 and Joliet 29 Stations has been placed in standing water in the bottom of the LSQ landfill for many years. IEPA has known of contamination of surrounding groundwater by coal ash since 1994. Since 1996, MG has been granted an adjusted standard allowing continued degradation of onsite groundwater. IEPA has approved applicable groundwater quality standards at levels exceeding Illinois Class I standards for boron, cadmium, and selenium by 5.9 times, 52 times, and 6.5 times, respectively.
EIP (2010a) also notes that MG undertook sampling of 18 private wells near the LSQ landfill. The only ash-related contaminant examined in the wells was boron, which was found up to five times above background concentrations in eight of the wells south of the landfill (the other wells were to the east or “up-gradient”).
EIP (2010a) claims that this would indicate that other contamination from the LSQ landfill would likely affect these down-gradient wells. After the sampling, MG offered to either buy out the properties or drill new, deeper wells for these residences south of the LSQ landfill.
EIP (2010a) also identified a number of instances of groundwater contamination in the monitoring wells around the LSQ landfill, noting reports from 2007, 2008, and 2009.
EIP (2010a) notes a total of 50 different exceedances of the IEPA AGQSs154 at 10 different wells, eight of which are over 150 feet from the LSQ landfill. The AGQSs are generally at or above the Illinois Class I Groundwater standard, which often matches the EPA Maximum Contaminant Level (MCL). The contamination indicated includes arsenic (up to 0.1 mg/L), above the primary EPA MCL at two wells located to the southeast, as well as sulfate (up to 690 mg/L), total dissolved solids (TDS: up to 1,300 mg/L), and pH (up to 9.98), above secondary EPA MCLs (SMCLs) in various wells. There is also contamination of ammonia (up to 5.3 mg/L), above the AGQS, boron (up to 10 mg/L) above the AGQS and EPA Child Health Advisory, and molybdenum (up to 2.9 mg/L) above the AGQS and EPA Lifetime Health Advisory. Exceedances of selenium (up to 0.325 mg/L) and cadmium (up to 0.264 mg/L), above the corresponding primary EPA
EIP (2010a) also notes that the NPDES permit issued by IEPA for the LSQ landfill in 2000 identifies Outfall No. 5 as “quarry (ash pond) discharge.” Still, this permit requires only testing for pH and total suspended solids.156 The latest (August 2009) IEPA Inspection Report available at that time indicates that
MG contends in its comment to the docket (EPA-HQ-RCRA-2009-0640-8244) that MG was actually the party who brought these concerns to the attention of IEPA, BRP and to the community and proposed alternatives to prevent any such risk from occurring.
Namely, the relaxed standards imposed by the IEPA in 1996. In its comment to the proposed CCR rule docket (EPA-HQ-RCRA-2009-0640-9765) EPRI claims that the calculated limits for cadmium and selenium (based on statistical analysis of background data) in EIP (2010a) appear to have been misinterpreted to represent maximum observed concentrations at the Joliet 9 site. However, these concentrations appear to actually be calculated Applicable Groundwater Quality Standards (AGQS) for the site. The current NPDES permit (IL0002216), for which the public notice ended on November 13, 2012, does require monitoring of a rather wide array of metals (As, Ba, Cd, Cr – hexavalent and total, Cu, Fe, Pb, Mn, Hg, Ni, Se, Ag, and Zn), in addition to cyanide, fluoride, oil, and phenols (IEPA, 2011). IIb Potential CCR Damage Cases
PART I (Cases 1-32) December 2014 MG is in compliance with the permit.157 MG concedes158 that limited amounts of collected leachate discharge into the Des Plaines River: in accordance with the AGQS granted by the IPCB for the LSQ,
MG concedes that the LSQ had been granted six waivers from Class I standards.159 However, MG denies that a Notice of Violation (NOV) has been issued for non-compliance in the landfill;160 and that MG’s proposal to provide alternative wells to residences south of the LSQ landfill was due to detected groundwater exceedances. MG states that in 2006, it sampled 18 residential wells located immediately to the south and southeast of the LSQ landfill, establishing that these wells were not degraded. Boron was used merely as an indicator parameter in this sampling of residential wells to search for potential Quarryrelated effects.161 Furthermore, MG claims that it did not “buy out” any residents, but rather made an unconditional offer to provide new, deeper wells for these residents. Also, groundwater modeling done at that time did not show that any excursion of a groundwater standard would affect these residential wells in the future.162
However, according to EIP (2010a), based on that report, from January 2008 to May 2009, pH exceeded the
EPA-HQ-RCRA-2009-0640-8244. MG’s comment to the proposed CCR rule docket: EPA-HQ-RCRA-2009-0640-8244, states that the LSQ landfill was required to install a-26 groundwater monitoring well network, three of which are off-site. Eighteen of the 24 parameters monitored at the landfill have AGQS values that are equal to or stricter than the corresponding Illinois Class I Groundwater standards. By inference, this suggests that the remaining six parameters monitored at the LSQ site have AGQS values that are less strict than the corresponding Illinois Class I groundwater standards. See also a preceding footnote for further clarification about the legal circumstances under which IEPA grants AGQSs.
MG’s comment to the proposed CCR rule docket: EPA-HQ-RCRA-2009-0640-8244 and Edison Mission Energy’s comment to the October 2011 NODA docket: EPA-HQ-RCRA-2011-0392-0237. MG claims that a draft
Environment, Thirty-Nine New Damage Cases of Contamination from Improperly Disposed Coal Combustion Waste, Case #8, Environmental Integrity Project, Earthjustice and Sierra Club, August 26, 2010. http://www.environmentalintegrity.org/news_reports/08_26_10.php
Appendix C, Case #8. ICF, 10/2010. Hood, Joel. Report Alleges Contamination of Private Wells in Joliet. Chicago Breaking News, August 26, 2010. Accessed Online October 2010. http://www.chicagobreakingnews.com/2010/08/report-alleges-contamination-of-private-wells-injoliet.html (No longer accessible)
US EPA, Facility Registry System, Facility Detail Report, Midwest Generation, Joliet 9 Accessed Online October 2010. http://iaspub.epa.gov/enviro/fii_query_dtl.disp_program_facility?p_registry_id=110000432773 (No longer accessible)
IEPA (2011): Illinois EPA’s Ash Impoundment Strategy Progress Report, October 2011. Accessed Online June 2012. http://www.epa.state.il.us/water/ash-impoundment/documents/ash-impoundment-progress-102511.pdf Stant and Barkley (2011): Illinois at Risk. Lax safeguards and no enforcement endanger the water, air & lives of residents near coal ash dumps, Jeff Stant and Traci Barkley, Environmental Integrity Project and Prairie Rivers Network, August 17th, 2011. Accessed Online June 2012. http://www.environmentalintegrity.org/documents/IllinoisatRisk.pdf Accessed June 2012 Visocky et al., (1985): Geology, Hydrology, and Water Quality of the Cambrian and Ordovician Systems in Northern Illinois. Adrian P. Visocky, Marvin G. Sherrill, and Keros Cartwright, 1985, State of Illinois Department of Energy and Natural Resources Cooperative Groundwater Report 10. Illinois State Geological Survey, Illinois State Water Survey, in cooperation with United States Geological Survey. Accessed Online June 2012. http://isws.illinois.edu/pubdoc/COOP/ISWSCOOP-10.pdf
IEPA (2011): Draft Reissued NPDES Permit to Discharge into Waters of the State, NPDES Permit No. IL0002216, Notice No. JAR: 11011701.ajo, Illinois Environmental Protection Agency Bureau of Water, Division of Water Pollution Control Permit Section, October 13, 2012. www.epa.state.il.us/...joliet-9/h. IIb Potential CCR Damage Cases
BTU/lb. Major CCR types are coal fly ash, bottom ash, and (since the late 1970s) flue gas desulfurization (FGD) sludge. According to SIPC (2012) and Sourcewatch (2010), SIPC’s Baseload capacity is provided by two coal-fired boilers. In 2003, SIPC replaced three aging small boilers (Units 1-3: 1963 vintage, 33 MW each) with one 120 MW circulating fluidized bed boiler. Capable of burning a variety of fuels, it is currently fueled with locally available mine waste. The second unit (originally, Unit 4) comprises a 173 MW coal-fired unit, which came online in 1978. This unit has been equipped from the outset with a wet scrubber, and since 2003, also with a selective catalytic reduction technology. According to Marion Plant’s Response to EPA’s Information Request (2011), there are actually 11 discrete, active surface impoundments, with a total capacity of 411 acre-feet: seven were commissioned in 1976, one – in 1988, one- in 1992, and three – in 1996. They range from the large South Fly Ash Dam and Pond S-1 (103 acre-feet and 71 acre-feet, respectively), to the small Pond S-6 and Pond 1 (16 acre-feet and 9 acre-feet, respectively). Most ponds are designated for the disposal of fly ash and/or flue gas emission control residuals, whereas Ponds 1 and 2 are designated for the storage of bottom ash/boiler slag, ultimately removed for beneficial use.
Kleinfelder (2013) inspected the bottom ash Ponds 1, 2, and 4, claiming that (i) all were commissioned in 1963, (ii) the presence of a liner is ‘unknown’, (iii) their pool areas are 1.75 acre, 2 acre, and 4.2 acre, respectively,
SIPC created the Lake of Egypt in 1962, by damming the South fork of the Saline River, a tributary of the Ohio
PART I (Cases 1-32) December 2014 recently found in two of the wells, which the SIPC attributes to rusting well covers.
EIP (2010a) also notes that sulfate occasionally exceeded the EPA SMCL and boron occasional exceeded the Illinois Class I Groundwater Standard (2.0 mg/L) since monitoring began. There are three wells within a one-mile radius of the CCR disposal areas, but their exact locations – including how many wells are down-gradient of the site, are unknown. According to the Illinois Environmental Protection Agency (IEPA),182 The Agency has groundwater monitoring well sampling data from eight sampling events ranging from January 2007 to November 2008 that indicate elevated cadmium and iron concentrations. SIPC renovated (repaired and cleaned out) their monitoring wells in 2010 and replaced two monitoring wells. Groundwater sampling reports at their monitoring wells from five sampling events ranging from June 2010 through June 2011 confirmed elevated levels of boron and iron with one detection of cadmium that has not been confirmed since well renovation. Elevated iron may also be due to a nearby coal mined area.
EIP (2010a) notes that the wells with the most significant contamination are those which lie between the
EIP (2010a) concedes that there does not appear to be any sampling to determine actual impacts of the discharges on Saline Creek. According to EIP (2010a), USEPA’s boron surface-water criteria for the protection of sensitive crops by longterm irrigation is 0.75 mg/L. Feedback from Richard P. Cobb, ibid. Feedback from Richard P. Cobb, ibid.
Environment, Thirty-Nine New Damage Cases of Contamination from Improperly Disposed Coal Combustion Waste, Case #9, Environmental Integrity Project, Earthjustice and Sierra Club, August 26, 2010. http://www.environmentalintegrity.org/news_reports/08_26_10.php
Appendix C, Case #9. ICF, 10/2010. US EPA, Facility Registry System, Facility Detail Report, Southern Illinois Power – Marion. Accessed Online October 2010. http://iaspub.epa.gov/enviro/fii_query_dtl.disp_program_facility?p_registry_id=110017420049
IEPA’s Ash Impoundments Strategy Progress Report (October 2011). Accessed Online December 2012. http://www.epa.state.il.us/water/ash-impoundment/documents/ash-impoundment-progress-102511.pdf
SIPC (2012): Southern Illinois Power Cooperative. Accessed Online December 2012. http://www.sipower.org/p/aboutsipc_history.php Sourcewatch (2010): Marion Plant. Accessed Online December 2012. http://www.sourcewatch.org/index.php?title=Marion_Plant Leonard Hopkins/SIPC (2011): Testimony before the House Energy & Commerce Committee, Subcommittee on Environment and the Economy, “Environmental Regulations, the Economy, and Jobs”, Leonard Hopkins, Fuel & Compliance Manager for Southern Illinois Power Cooperative - – February 15, 2011. Accessed Online December 2012. http://www.nreca.coop/press/Testimony/Documents/TestimonyLeonardHopkinsHouseEnergyCommerce Subcommittee.pdf
DCEO (2010): The Illinois Coal Industry, Report of the Department of Commerce and Economic Opportunity Office of Coal Development, June 2010. Accessed Online December 2012. http://www.ildceo.net/nr/rdonlyres/8e622cbc-2a9e-428a-9a0eefa1ec8a7ae2/0/coalindustry2010outline.pdf Marion Plant’s Response to EPA’s Information Request (2011): Information Request Regarding Surface Impoundments at the Marion Plant, January 5, 2011. Accessed Online December 2012. ponds, which is regulated by an NPDES Permit and have no bearing on actual surface water quality in Saline Creek.” Based on a telephone Conversation with Bill Buscher, Illinois Environmental Protection Agency, Bureau of
Water, October 21, 2010. IIb Potential CCR Damage Cases
PART I (Cases 1-32) December 2014 http://www.epa.gov/osw/nonhaz/industrial/special/fossil/surveys/soil-power-coop-marion-plant.pdf Nelson (2007): Bedrock Geology of Marion Quadrangle, Williamson County, Illinois, W. John Nelson, Illinois State Geological Survey, Illinois Geologic Quadrangle Map IGQ Marion-BG, 2007, 1:24,000. Accessed Online December 2012. http://www.isgs.illinois.edu/maps-data-pub/isgs-quads/m/pdf-files/marion-bg.pdf Jacobson et al., (1991): Geologic Map of the Goreville Quadrangle, Johnson and Williamson Counties,