Policy Replication

Additional PortaCount® Quantitative Fit-Testing Protocols: Amendment to Respiratory Protection Standard

Federal Register2016-10-07 · DEPARTMENT OF LABOR; Occupational Safety and Health Administration · Proposed Rule · 2016-23928
Notice of proposed rulemaking; request for comments.

OSHA is proposing to add two modified PortaCount[supreg] quantitative fit-testing protocols to its Respiratory Protection Standard. The proposed protocols would apply to employers in general industry, shipyard employment, and the construction industry. Both proposed protocols are variations of the existing OSHA-accepted PortaCount[supreg] protocol, but differ from it by the exercise sets, exercise duration, and sampling sequence. If approved, the modified PortaCount[supreg] protocols would be alternatives to the existing quantitative fit-testing protocols already listed in an appendix of the Respiratory Protection Standard. In addition, OSHA is proposing to amend an appendix to clarify that PortaCount[supreg] fit test devices equipped with the N95-Companion<SUP>TM</SUP> Technology are covered by the approved PortaCount[supreg] protocols.

RIN 1218-AC94 · Docket OSHA-2015-0015

Other documents for the same rulemaking (all, by stage)

2016-06-14 Docket documentTSI. (2014b). TSI White Paper: Analysis of the talking exercise used for respirator fit testing, July 10, 2014.
2016-10-07 Docket document[NIOSH] National Institute for Occupational Safety and Health. (2001). Respirator Usage in Private Sector Firms, 2001. Bureau of Labor Statistics, National Institute for Occupational Safety and Health, September 2001.
2016-10-07 Docket document[BLS] Bureau of Labor Statistics. (2014). Employer Costs for Employee Compensation, December 2014. http://www.bls.gov/news.release/archives/ecec_03112015 [See Table A].
2018-10-10 Docket document[NIOSH] National Institute for Occupational Safety and Health. (September 2003). Respirator Usage in Private Sector Firms, 2001. Bureau of Labor Statistics, National Institute for Occupational Safety and Health.
2018-11-13 Docket documentCensus Bureau (2017). 2015 County Business Patterns.
2019-09-26 Federal RegisterAdditional Ambient Aerosol CNC Quantitative Fit Testing Protocols: Respiratory Protection Standard

References: 14 extracted, 4 linked to papers

Page 1Download these results: CSV · JSON
Richardson et al., 2013; Richardson et al., 2014a; Richardson et al., 2014b
Niccum included a copy of three peer-reviewed articles from the industrial-hygiene journal, entitled Journal of the International Society for Respiratory Protection, describing the accuracy and reliability of these proposed protocols (Richardson et al., 2013; Richardson et al., 2014a; Richardson et al., 2014b).
Richardson, AW, Hofacre, KC, Weed, J, Holm, R, and Remiarz, R. (2014a). Evaluation of a faster fit testing method for elastomeric half-mask respirators based on the TSI PortaCount®. Journal of the International Society for Respiratory Protection. 31(1): 9-22.
Niccum included a copy of three peer-reviewed articles from the industrial-hygiene journal, entitled Journal of the International Society for Respiratory Protection, describing the accuracy and reliability of these proposed protocols (Richardson et al., 2013; Richardson et al., 2014a; Richardson et al., 2014b).
Richardson, AW, Hofacre, KC, Weed, J, Holm, R, and Remiarz, R. (2014b). Evaluation of a faster fit testing method for filtering facepiece respirators based on the TSI PortaCount®. Journal of the International Society for Respiratory Protection. 31(1): 43-56.
Niccum included a copy of three peer-reviewed articles from the industrial-hygiene journal, entitled Journal of the International Society for Respiratory Protection, describing the accuracy and reliability of these proposed protocols (Richardson et al., 2013; Richardson et al., 2014a; Richardson et al., 2014b).
[ANSI/AIHA] American National Standards Institute, Inc./American Industrial Hygiene Association. (2010). ANSI/AIHA Z88.10-2010. American National Standard-Respirator Fit Testing Methods.
otherNot linked to a paper · V. References
Brosseau, LM and Jones RM. (2015). Evaluation of three new condensation nuclei counter (CNC) fit testing protocols. February 22, 2015.
research reportNot linked to a paper · Section II.B.2 Study Results
Zhuang, Z, Coffey, CC and Lawrence, RB. (2004). The effect of ambient aerosol concentration and exercise on PortaCount® quantitative fit factors. Journal of the International Society for Respiratory Protection 21: 11-20.
(Zhuang et al., 2004).
TSI. (2014b). TSI White Paper: Analysis of the talking exercise used for respirator fit testing, July 10, 2014b.
research reportNot linked to a paper · Section II.B.1 Study Methods
TSI. (2015a). Exercise Rational Cover Letter and Exercise Selection Rationale White Paper submitted to OSHA by Gregory Olson of TSI, February 6, 2015.
research reportNot linked to a paper · Section II.B.1 Study Methods
TSI. (2015b). Letter submitted to OSHA by TSI (Gregory Olson), April 2, 2015.
otherNot linked to a paper · Section II.D.1 Study Methods
TSI. (2015c). Phone conversation between TSI and Labor Department employees, April 6, 2015.
otherNot linked to a paper · Section IV.B Preliminary Economic Analysis
NIOSH. (2003). Respirator Usage in Private Sector Firms, 2001. Bureau of Labor Statistics, National Institute for Occupational Safety and Health, September 2003.
datasetNot linked to a paper · Section IV.B Preliminary Economic Analysis · cited link
Census Bureau. (2012). County Business Patterns. File downloaded 6/3/2014 http://www.census.gov/econ/cbp/download/
datasetNot linked to a paper · Section IV.B Preliminary Economic Analysis, fn 2-3 · cited link
Bureau of Labor Statistics. (2016a). News Release, March 30, 2016. Occupational Employment and Wages—May 2015.
government reportNot linked to a paper · Section IV.B Preliminary Economic Analysis, fn 4 · cited link
Bureau of Labor Statistics. (2016b). News Release, March 10, 2016. Employer Costs for Employee Compensation, December 2015.
government reportNot linked to a paper · Section IV.B Preliminary Economic Analysis, fn 4 · cited link