Policy Replication

2022-06 Technical Support Document: Energy Efficiency Program For Consumer Products And Commercial And Industrial Equipment: Consumer Furnaces (including Supplemental Appendix 8N, attached)

Regulatory impact analysis2022-06-13 · EERE · technical_support_document · EERE-2014-BT-STD-0031-0320
RIN 1904-AD20 · Docket EERE-2014-BT-STD-0031

Other documents for the same rulemaking (all, by stage)

2014-09-24 Regulatory impact analysis2014-09-23 Ex parte communication record of the meeting between AGA and DOE representatives on September 12, 2014 and Correction to memorandum (includes email cover letters, memorandum, Furnace Standard Stakeholder Discussion Document, Copy of Fuel Switching Impact Analysis Model, and Corrected ex parte communication memorandum)
2014-10-30 Federal RegisterEnergy Conservation Program for Consumer Products: Energy Conservation Standards for Residential Furnaces
2015-02-24 Regulatory impact analysis2015-02-10 Technical Support Document: Energy Efficiency Program for Consumer Products and Commercial and Industrial Equipment: Residential Furnaces
2015-03-12 Federal RegisterEnergy Conservation Program for Consumer Products: Energy Conservation Standards for Residential Furnaces
2015-05-20 Federal RegisterEnergy Conservation Program for Consumer Products: Energy Conservation Standards for Residential Furnaces
2015-09-14 Federal RegisterEnergy Conservation Program for Consumer Products: Energy Conservation Standards for Residential Furnaces
2015-10-23 Federal RegisterEnergy Conservation Program: Energy Conservation Standards for Residential Furnaces
2016-09-02 Regulatory impact analysis2016-08-30 SNOPR Analytical Tools: Residential Furnaces National Impact Analysis
2016-09-02 Regulatory impact analysis2016-08-30 SNOPR Analytical Tools: Residential Furnaces National Impact Analysis (NIA) - Plus Standby
2016-09-02 Regulatory impact analysis2016-08-30 SNOPR Analytical Tools: Residential Furnaces National Impact Analysis - Plus AFUE
2016-09-02 Regulatory impact analysis2016-08-30 SNOPR Technical Support Document: Energy Efficiency Program for Consumer Products and Commercial and Industrial Equipment: Residential Furnaces
2016-09-07 Regulatory impact analysisRIA cited in FR 2016-20934: Federal Motor Vehicle Safety Standards; Federal Motor Carrier Safety Regulations; Parts and Accessories Necessary for Safe Operation; Speed Limiting Devices
2016-09-22 Docket document2016-06-21 OMB Executive Order 12866 Meeting Record
2016-09-23 Federal RegisterEnergy Conservation Program: Energy Conservation Standards for Residential Furnaces
2016-10-27 Regulatory impact analysis2016-10-26 DOE response to AHRI questions regarding Table 7.3.2 in the SNOPR TSD
2016-11-14 Regulatory impact analysis2016-11-14 Rheem question regarding the SNOPR TSD and DOE response
2016-12-05 Federal RegisterEnergy Conservation Program: Energy Conservation Standards for Residential Furnaces
2017-04-03 Regulatory impact analysis2017-03-14 Executive correspondence from APGA, Spire Inc., ACCA, et al., to Secretary Perry requesting correction of regulatory analysis before final actions are taken.
2017-07-10 Regulatory impact analysisRIA cited in FR 2017-14079: Energy Conservation Program: Energy Conservation Standards for Walk-In Cooler and Freezer Refrigeration Systems
2017-07-10 Regulatory impact analysisRIA cited in FR 2017-14079: Energy Conservation Program: Energy Conservation Standards for Walk-In Cooler and Freezer Refrigeration Systems
2020-01-10 Regulatory impact analysisRIA cited in FR 2019-26350: Energy Conservation Program: Energy Conservation Standards for Portable Air Conditioners
2020-01-10 Regulatory impact analysisRIA cited in FR 2019-26350: Energy Conservation Program: Energy Conservation Standards for Portable Air Conditioners
2022-07-07 Federal RegisterEnergy Conservation Program: Energy Conservation Standards for Consumer Furnaces
2022-08-30 Federal RegisterEnergy Conservation Program: Energy Conservation Standards for Consumer Furnaces
2023-02-27 Regulatory impact analysisRIA cited in FR 2023-03436: Energy Conservation Program: Energy Conservation Standards for Refrigerators, Refrigerator-Freezers, and Freezers
2023-02-27 Regulatory impact analysisRIA cited in FR 2023-03436: Energy Conservation Program: Energy Conservation Standards for Refrigerators, Refrigerator-Freezers, and Freezers
2023-02-27 Regulatory impact analysisRIA cited in FR 2023-03436: Energy Conservation Program: Energy Conservation Standards for Refrigerators, Refrigerator-Freezers, and Freezers
2023-02-27 Regulatory impact analysisRIA cited in FR 2023-03436: Energy Conservation Program: Energy Conservation Standards for Refrigerators, Refrigerator-Freezers, and Freezers
2023-04-11 Regulatory impact analysisRIA cited in FR 2023-06499: Energy Conservation Program: Energy Conservation Standards for Air Cleaners; Final Rule
2023-09-29 Regulatory impact analysis2023-09 Technical Support Document: Energy Efficiency Program for Consumer Products and Commercial and Industrial Equipment: Consumer Furnaces, September 2023
2023-09-29 Docket documentDocumentation of Changes between the draft Final Rule submitted to the Office of Information and Regulatory Affairs (OIRA) and the issued Final Rule
2023-12-18 Federal RegisterEnergy Conservation Program: Energy Conservation Standards for Consumer Furnaces

References: 330 extracted, 10 linked to papers

Page 5Download these results: CSV · JSON
Publications, Inc.: Belmont, CA. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. 1997
research reportNot linked to a paper · refsec
ASHRAE Handbook: Fundamentals. 1997. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.: Atlanta, GA.
journal articleNot linked to a paper · refsec
Proctor, J. and D. Parker. Hidden Power Drains: Residential Heating and Cooling Fan Power Demand. In 2000. American Council for an Energy-Efficient Economy. 1: pp. 225–234. (Last accessed February 1, 2022.) http://aceee.org/files/proceedings/2000/data/papers/SS00_Panel1_Paper19.pdf.
research reportNot linked to a paper · refsec · cited link
Pigg, S. Electricity Use by New Furnaces: A Wisconsin Field Study. 2003. Energy Center of Wisconsin: Madison, Wisconsin. Report No. 230–1. Center for Energy and Environment (CEE). Comment #22 from CEE On Preliminary Analysis for Energy Conservation Program for Consumer Products: Energy Conservation Standards for Residential Furnace Fans (Docket number EERE-2010-BTSTD-0011, RIN 1904-AC22). 2010. (Last accessed February 1, 2022.) https://www.regulations.gov/comment/EERE-2010-BT-STD-0011-0022. 7B-35
research reportNot linked to a paper · refsec · cited link
LIST OF TABLES Table 7C.3.1 Weather Station Mapping Statistics, Heating and Cooling ODT, and Average Outdoor Temperature ..........................................................................7C-2 Table 7C.3.2 Weather Station Monthly Heating Degree Day Data (10-Year Average, 2011-2020) .........................................................................................................7C-9 Table 7C.3.3 Weather Station Monthly Cooling Degree Day Data (10-Year Average, 2011-2020) .......................................................................................................7C-15 Table 7C.3.4 Weather Station Monthly Heating Degree Day Data Fractions (10-Year
datasetNot linked to a paper · refsec
Average, 2011-2020) .......................................................................................7C-20 Table 7C.3.5 Weather Station Monthly Cooling Degree Day Data Fractions (10-Year
research reportNot linked to a paper · refsec
Average, 2011-2020) .......................................................................................7C-26 Table 7C.3.6 Weather Station Monthly Average Outdoor Temperature (1971-2000)..........7C-32 7C-i
research reportNot linked to a paper · refsec
BUILDINGS 7C.1 INTRODUCTION The Energy Information Administration’s (EIA) 2015 Residential Energy Consumption Survey (RECS 2015)1 and EIA’s 2012 Commercial Building Energy Consumption Survey (CBECS 2012)2 provide annual data on heating and cooling degree-days but not on other weather parameters needed for the analysis such as heating and cooling outdoor design temperature (ODT), monthly heating degree days (HDD) and monthly cooling degree days (CDD), and average outdoor temperature. ODTs are used for sizing consumer furnaces as described in appendix 7B. Energy price data used in this analysis are available on a monthly basis. Monthly HDD are used to disaggregate the annual energy use provided by RECS and
research reportNot linked to a paper · refsec
1. DOE assembled monthly weather data from 360 weather stations from the National Oceanic and Atmospheric Administration (NOAA) that provide the heating and cooling degree-days at base temperature 65oF for year 2015 (for the RECS sample) and year 2012 (for the CBECS sample), for these weather stations.3 The 2015 and 2012 heating and cooling degree days match the period used to determine the degree-days in RECS 2015 and in CBECS 2012, respectively.
research reportNot linked to a paper · refsec
2. RECS 2015 and CBECS 2012 report both HDD and CDD to base temperature 65oF for each building record. DOE assigned each building to one of the 360 weather stations by calculating which weather station (within the appropriate region) was the closest using the best linear least squares fit of the RECS 2015 and CBECS 2012 data to the weather data for each region in the RECS 2015 and CBECS 2012 data. To differential between the heating and cooling degree days is normalized using the maximum heating and cooling degree days by region from the weather station data. 3. To make sure that the final weighting of RECS households by state matches the U.S. Census housing data,b DOE added a state weighting correction factor. DOE does not have any comparable state level data for commercial buildings, so no correction factor was added to CBECS 2012 weather station matching. For confidentiality, heating and cooling degree day values were altered slightly by EIA to mask the exact geographic location of the housing unit or building. U.S. Census Bureau, Population Division. Annual Estimates of Housing Units for the United States, Regions, and States: April 1, 2010 to July 1, 2019 (NST-EST2019-ANNHU). May 2020 7C-1 Eq. 7C.1 calculates the U.S. weather station closest (or with minimum “distance”) to the
research reportNot linked to a paper · refsec
Washington, D.C. U.S. Department of Energy - Energy Efficiency & Renewable Energy. Energy Conservation Program for Consumer Products: Technical Support Document: Energy Efficiency Standards for Consumer Products: Residential Furnaces and Boilers. 2007.
research reportNot linked to a paper · refsec
Washington, D.C. Report No. EERE-2011-BT-STD-0011-0012. U.S. Department of Energy–Office of Energy Efficiency and Renewable Energy. Energy Conservation Program for Consumer Products: Technical Support Document: Energy Efficiency Standards for Consumer Products: Residential Furnace Fans. July 2014.
research reportNot linked to a paper · refsec
Washington, D.C. (Last accessed February 1, 2022.) https://www.regulations.gov/document/EERE-2010-BT-STD-0011-0111. 7D-13
research reportNot linked to a paper · refsec · cited link
LCC Results spreadsheet summarizes the LCC results as well as provides the LCC outputs for the NIA spreadsheet. The three spreadsheets are independent. The main LCC spreadsheet can be downloaded and run separately. To change the input of the main LCC based or updated data from the Analysis Input spreadsheet, the user will need to manually copy/paste the data that was modified in the Analysis Input spreadsheet into the main LCC spreadsheet. Finally, to populate the results in the LCC Results spreadsheet, the user will need to manually copy/paste the updated extracted forecast cells from the main LCC spreadsheet into the LCC Results spreadsheet. To examine the spreadsheets, DOE assumes that the user has access to a personal computer with hardware capable of running Windows XP or later. All spreadsheets require Microsoft Excel 2003 or later installed under the Windows operating system. Crystal Ball a (a commercially available Excel add-on program) is also needed to regenerate the LCC results and to view the statistical distributions that are used to define certain variables inside the spreadsheets. 8A.3
research reportNot linked to a paper · refsec
LCC&PB Calcs* The LCC&PB Calcs worksheet shows LCC calculation results for different efficiency levels for a single RECS 2015 household or CBECS 2012 building. During a Crystal Ball simulation, the spreadsheet records the LCC and PBP values for every sampled household or building. Rebuttable Payback The Rebuttable Payback worksheet contains the total and incremental manufacturer costs, retail prices, installation costs, repair and maintenance costs, energy use calculations, and the simple PBP calculations for each efficiency level. DOE’s consumer furnace and furnace test procedure is used to calculate parameters used in energy use calculations. Prod Price* The Prod Price worksheet calculates retail price values used as inputs in the
research reportNot linked to a paper · refsec
Barreto, H. and F. Howland. Introductory Econometrics: Using Monte Carlo Simulation with Microsoft Excel. 2006. Cambridge University Press: New York, NY. U.S. Department of Energy–Energy Information Administration. 2015 Residential Energy Consumption Survey (RECS). 2015. (Last accessed February 1, 2022.) https://www.eia.gov/consumption/residential/data/2015/. U.S. Department of Energy–Energy Information Administration. 2012 Commercial Buildings Energy Consumption Survey (CBECS). 2012. (Last accessed February 1, 2022.) https://www.eia.gov/consumption/commercial/data/2012/.
journal articleNot linked to a paper · refsec · cited link
Furnaces. 2010. Dallas, TX. D.D. Paul et al. Assessment of Technology for Improving the Efficiency of Residential
research reportNot linked to a paper · refsec
Gas Water Heaters. 1991. Battelle: Columbus, OH.
research reportNot linked to a paper · refsec
Jakob, F. E., J. J. Crisafulli, J. R. Menkedick, R. D. Fischer, D. B. Philips, R. L. Osbone, J. C. Cross, G. R. Whitacre, J. G. Murray, W. J. Sheppard, D. W. DeWirth, and W. H. Thrasher. Assessment of Technology for Improving the Efficiency of Residential Gas Furnaces and Boilers, Volume I and II - Appendices. 1994. Gas Research Institute: AGA
research reportNot linked to a paper · refsec
Decision Analysts. 2008 American Home Comfort Study. 2008. Arlington, Texas. (Last accessed February 1, 2022.) http://www.decisionanalyst.com/Syndicated/HomeComfort.dai. 8B-30
research reportNot linked to a paper · refsec · cited link
LIST OF FIGURES Figure 8C.3.1 Figure 8C.3.2 Figure 8C.3.3 Nominal and Deflated Warm Air Furnaces PPI from 1990 to 2020............8C-3
research reportNot linked to a paper · refsec
Extrapolated, Historical and Projected Shipments of Warm Air Furnaces .......................................................................................................8C-4 Relative Price versus Cumulative Shipments of Warm Air Furnaces from 1990 to 2020, with Power Law Fit ......................................................8C-5 8C-i Figure 8C.4.1 Figure 8C.5.2
research reportNot linked to a paper · refsec
Air-Conditioning, Heating, and Refrigeration Institute. Furnaces Historical Data. (Last accessed February 1, 2022.) https://www.ahrinet.org/resources/statistics/historicaldata/furnaces-historical-data. 8C-22
research reportNot linked to a paper · refsec · cited link
RSMEANS 2021 REGIONAL LABOR COSTS ................................................. 8D-38
research reportNot linked to a paper · refsec
LIST OF TABLES Example Installation Cost Table ................................................................. 8D-1 Furnace Installation Location Data (2011 Decision Analysts, Inc. Survey) ........................................................................................................ 8D-7 Furnace Installation Location Data (GRI 1992 Study) ............................... 8D-7 Comparison of Furnace Installation Location Fractions............................. 8D-7 Basic Installation Cost Example Using National Labor Costs: New Construction and New Owner ..................................................................... 8D-8 Basic Installation Cost Example Using National Labor Costs: Replacement ................................................................................................ 8D-9 Basic Installation Costs for Non-Weatherized Gas Furnaces by Market . 8D-10 Fraction of Existing Masonry Chimney and Metal Vent Installations ..... 8D-14 Fraction of Commonly-Vented Furnace and Water Heater Installations . 8D-15 Replacement Venting Situations for Non-Weatherized Gas Furnaces ..... 8D-19 Non-Condensing to Non-Condensing Venting Issues, Fraction
research reportNot linked to a paper · refsec
Pumps, and Furnaces. 2011. no. EERE-2011-BT-STD-0011-0012: (Last accessed February 1, 2022.) https://www.regulations.gov/document/EERE-2011-BT-STD-00110012. U.S. Department of Energy–Office of Energy Efficiency and Renewable Energy. Energy Conservation Program for Consumer Products: Direct Final Rule Technical Support Document: Energy Efficiency Standards for Consumer Products and Certain Commercial and Industrial Equipment: Central Air Conditioners, Heat Pumps, and Furnaces. October 2011. Washington, D.C. (Last accessed February 1, 2022.) https://www.regulations.gov/document/EERE-2011-BT-STD-0011-0012. U.S. Department of Energy–Office of Energy Efficiency and Renewable Energy. Energy Conservation Program for Consumer Products: Final Rule Technical Support Document: Energy Efficiency Standards for Consumer Products and Commercial and Industrial Equipment: Pool Heaters, Direct Heating Equipment, and Water Heaters. April 2010. (Last accessed February 1, 2022.) https://www.regulations.gov/document?D=EERE2006-STD-0129-0149.
research reportNot linked to a paper · refsec · cited link
Smith, C. D. Consultant Report - Water Heater Installation Costs. 2008. Florence, SC.
research reportNot linked to a paper · refsec
Laboratories, Chicago, IL. Report No. GRI-94/0175. Decision Analysts. Homeowner “Spotlight” Report: Equipment Switching, Repair Profile and Energy Efficiency. 2011. Arlington, Texas. (Last accessed February 1, 2022.) http://www.decisionanalyst.com/Syndicated/HomeComfort.dai.
research reportNot linked to a paper · refsec · cited link
Furnaces. 2010. Dallas, TX. Momen, A. M., J. Munk, K. Biswas, and P. Hughes. Condensing Furnace Venting Part 1: The Issue, Prospective Solutions, and Facility for Experimental Evaluation,. 2014. Oak Ridge National Laboratory: Oak Ridge, TN. Report No. ORNL/TM-2014/624. (Last 8D-41 accessed February 1, 2022.) http://web.ornl.gov/sci/buildings/docs/Condensing-FurnaceVenting-Part1-Report.pdf.
research reportNot linked to a paper · refsec · cited link
Draft Water Heaters. 2015. Oak Ridge National Laboratory: Oak Ridge, TN. Report No.
research reportNot linked to a paper · refsec
ORNL/TM-2014/656. (Last accessed February 1, 2022.) http://web.ornl.gov/sci/buildings/docs/Condensing-Furnace-Venting-Part2-Report.pdf. D.D. Paul et al. Assessment of Technology for Improving the Efficiency of Residential
research reportNot linked to a paper · refsec · cited link
Gas Water Heaters. 1991. Battelle: Columbus, OH. National Association of Home Builders (NAHB). What 21st Century Home Buyers Want?. 2001. National Association of Home Builders Economics Group. National Fire Protection Association and American Gas Association. National Fuel Gas
research reportNot linked to a paper · refsec
Code. 2002. (Last accessed February 1, 2022.) http://catalog.nfpa.org/NFPA-54National-Fuel-Gas-Code-Prior-Years-P4125.aspx. Gas Appliance Manufacturers Association. Updated Shipment Data for Residential Furnaces and Boilers. 2005.
research reportNot linked to a paper · refsec · cited link
Air-Conditioning, Heating, and Refrigeration Institute. Data Submittal to DOE: Regional Furnace Shipments. July 20, 2010. 8D-42
research reportNot linked to a paper · refsec
LIST OF TABLES Table 8E.2.1 Table 8E.2.2 Table 8E.2.3 Table 8E.2.4 Table 8E.2.5 Table 8E.2.6 Table 8E.3.1 Table 8E.3.2 Table 8E.3.3 Table 8E.3.4 Table 8E.3.5 Table 8E.3.6 2020 Monthly Residential Electricity Prices by State (2020¢/kWh) ........... 8E-3 2020 Monthly Commercial Electricity Prices by State (2020¢/kWh) ......... 8E-4 2020 Monthly Residential Natural Gas Prices by State (2020$/MMBtu) ........................................................................................... 8E-5 2020 Monthly Commercial Natural Gas Prices by State (2020$/MMBtu) ........................................................................................... 8E-6 2020 AEO LPG Excalation Factors from 2019 to 2020 (2020$/MMBtu) ........................................................................................... 8E-7 2020 Average Annual LPG Prices by State (2020$/MMBtu) ..................... 8E-7 2001-2020 Average Residential Electricity Prices for New York from
research reportNot linked to a paper · refsec
DOE used Energy Information Administration (EIA) data by state to determine average annual prices for the 2020 base year (section 8E.2), monthly price factors (section 8E.3), and seasonal marginal price factors (section 8E.4). To match the state energy price data to the building sample developed using EIA’s 2015 Residential Energy Consumption Survey (RECS 2015)1 and 2012 Commercial Building Energy Consumption Survey (CBECS 2012),2 the Department of Energy (DOE) used weather data to assign a state to each sampled housing unit or building (see appendix 7-C for more details). Energy prices were then escalated by the EIA’s 2021 Annual Energy Outlook (AEO 2021) forecasts to estimate future energy prices at the census division level (see section 8E.7). 8E.2
research reportNot linked to a paper · refsec
DOE derived 2020 annual electricity prices from EIA’s Form 861M.4 The EIA Form 861M data include residential and commercial energy prices by state. Table 8E.2.1 and Table 8E.2.2 show the monthly residential and commercial electricity prices for each state. DOE calculated annual electricity prices by averaging monthly electricity prices by state. 8E-1
research reportNot linked to a paper · refsec
DOE obtained the data for natural gas prices from EIA’s Natural Gas Navigator,5 which includes monthly natural gas prices by state for residential, commercial, and industrial customers. Table 8E.2.3 shows the monthly residential natural gas prices for each state. Table 8E.2.4 shows the monthly commercial natural gas prices for each state. DOE calculated both residential and commercial annual natural gas prices by averaging monthly natural gas prices by state. DOE used a conversion factor (1.037) to convert cubic feet of natural gas to MMBtu.a www.eia.gov/tools/faqs/faq.cfm?id=45&t=7 8E-2 Table 8E.2.1 2020 Monthly Residential Electricity Prices by State (2020¢/kWh) State Alabama 12.31 Alaska 22.33 Arizona 11.55 Arkansas 9.84 California 19.91 Colorado 11.73 Connecticut 22.40 Delaware 12.05 District of Columbia 12.38 Florida 11.34 Georgia 11.05 Hawaii 31.69 Idaho 9.86 Illinois 12.84 Indiana 12.22 Iowa 11.21 Kansas 12.10 Kentucky 10.68 Louisiana 9.24 Maine 16.82 Maryland 13.41 Massachusetts 22.88 Michigan 15.58 Minnesota 12.23 Mississippi 11.27 Missouri 9.82 Montana 10.89 Nebraska 9.41 Nevada 11.93 New Hampshire
research reportNot linked to a paper · refsec
Consumption, Price, and Expenditure Estimates (SEDS). 2019. Washington, D.C. (Last accessed February 1, 2022.) http://www.eia.gov/state/seds/. U.S. Department of Energy–Energy Information Administration. Annual Energy Outlook 2020 with Projections to 2050. 2020. Washington, D.C. Report No. AEO2020. (Last accessed February 1, 2022.) https://www.eia.gov/outlooks/aeo/pdf/aeo2020.pdf. U.S. Department of Energy-Office of Codes and Standards. Marginal Energy Prices
research reportNot linked to a paper · refsec · cited link
Report. 1999. Lawrence Berkeley National Laboratory: Berkeley, CA. Report No.
research reportNot linked to a paper · refsec
LBNL-46625. (Last accessed February 1, 2022.) https://ees.lbl.gov/publications/marginal-energy-prices.
research reportNot linked to a paper · refsec · cited link
Chaitkin, S. and J. E. McMahon. Marginal Energy Prices - RECS97 Update. 2000. (Last accessed February 1, 2022.) https://www.energy.gov/eere/buildings/downloads/marginalenergy-prices-recs97-update.
research reportNot linked to a paper · refsec · cited link
Chaitkin, S., J. E. McMahon, C. Dunham, R. Van Buskirk, and J. Lutz. Estimating Marginal Residential Energy Prices in the Analysis of Proposed Appliance Energy Efficiency Standards. In ACEEE Summer Study on Energy Efficiency in Buildings. 2000.p. (Last accessed February 1, 2022.) https://www.aceee.org/files/proceedings/2000/data/papers/SS00_Panel9_Paper03.pdf.
research reportNot linked to a paper · refsec · cited link
Dunham, C., V. Franco, A. Lekov, and J. Lutz. Development of the Household Sample for Furnace and Boiler Life-Cycle Cost Analysis. 2005. (Last accessed February 1, 2022.) https://eta.lbl.gov/publications/development-household-sample-furnace. 8E-43 American Gas Association. Natural Gas – Marginal Cost Analysis. 2014. (Last accessed February 1, 2022.) https://www.aga.org/research/reports/natural-gas--marginal-costanalysis---june-2014/.
research reportNot linked to a paper · refsec · cited link
Lavappa, P. D. and J. D. Kneifel. Energy Price Indices and Discount Factors for LifeCycle Cost Analysis – 2021 Annual Supplement to NIST Handbook 135. 2021. National Institute of Standards and Technology (NIST). Report No. NISTIR 85-3273-36. (Last accessed February 1, 2022.) https://nvlpubs.nist.gov/nistpubs/ir/2020/NIST.IR.85-327335.pdf. 8E-44
journal articleNot linked to a paper · refsec · cited link
LIST OF TABLES Table 8F.1.1 Table 8F.2.1 Table 8F.3.1 Table 8F.3.2 Table 8F.4.1 Table 8F.4.2 Example Cost Table ........................................................................................ 8F-1 Maintenance Fractions based on 2008 American Home Comfort Survey ..... 8F-2 Furnace Repair Rates ...................................................................................... 8F-2 Furnace Repair Costs ...................................................................................... 8F-3
research reportNot linked to a paper · refsec
RS Means 2021 National Average Labor Costs by Crew............................... 8F-3
research reportNot linked to a paper · refsec
REPAIR COST FOR CONSUMER FURNACES The repair cost is the cost to the consumer for replacing or repairing components in the furnace that have failed. DOE estimated repair costs at each considered efficiency level using a variety of sources, including 2021 RSMeans Facilities Repair and Maintenance Data,2 manufacturer literature, and information from expert consultants. DOE accounts for regional differences in labor costs, as discussed in appendix 8D. Table 8F.3.1 and Table 8F.3.2 show repair rate and cost assumptions that DOE used in its analysis. The failure year distribution was assumed to be a Weibull function for each component. Table 8F.3.1 Furnace Repair Rates Repair Description
research reportNot linked to a paper · refsec
Ignition, Controls, Gas Valve (Baseline) Ignition, Controls, Gas Valve (Condensing) Fan Blower Bare Material Cost (2020$)* Total Labor Hours $227.99 2.25 $289.61 2.75 $268.11 3.43 *Does not include sales tax or markups by trade from RS Means. 8F.4
research reportNot linked to a paper · refsec
REGIONAL MATERIAL AND LABOR COSTS DOE used regional material and labor costs to more accurately estimate installation, maintenance, and repair costs by region. RSMeans provides average national labor costs for different trade groups. DOE used the residential repair and remodeling labor cost from RSMeans crew type Q1 (1 Plumber, 1 Plumber Apprentice) for all repair and maintenance labor cost calculations, as shown in Table 8F.4.1.1 Bare costs are given in RSMeans, while labor costs including overhead and profit (O&P) are the bare costs multiplied by the RS Means markups by trade shown in Table 8F.4.2. Table 8F.4.1 RS Means 2021 National Average Labor Costs by Crew Cost per Labor-Hour Crew Laborers Crew Description Type per Crew Bare Costs Incl. O&P* 2021 RS Means Labor Costs Data (Residential, Repair/Remodeling) 1 Plumber, 1 Plumber Apprentice $52.83 $82.40 * O&P includes markups in Table 8F.4.2 Table 8F.4.2 RS Means Labor Cost Markups by Trade Trade Plumber (Repair/Remodel) Workers Comp. Aver Fixed Overhead Overhead Profit Total 7.0% 18.0 16.0% 15.0% 56.0 RSMeans also provides material and labor cost factors for 295 cities and towns in the U.S. To derive average labor cost values by state, DOE weighted the price factors by city or town population size using 2020 census data. DOE used the material and labor cost factors for cost associated with fire suppression, plumbing, and HVAC. See appendix 8D for more details. 8F-3
research reportNot linked to a paper · refsec
← PreviousNext →