Energy Conservation Program: Energy Conservation Standards for Consumer Furnaces
Federal Register2022-07-07 · DEPARTMENT OF ENERGY · Proposed Rule · 2022-13108
Notice of proposed rulemaking and request for comment.
The Energy Policy and Conservation Act, as amended ("EPCA"), prescribes energy conservation standards for various consumer products and certain commercial and industrial equipment, including consumer furnaces. EPCA also requires the Department of Energy ("DOE" or "the Department") to periodically determine whether more-stringent, amended standards would be technologically feasible and economically justified, and would result in significant energy savings. In this notice of proposed rulemaking ("NOPR"), DOE proposes amended energy conservation standards for non-weatherized gas furnaces and mobile home gas furnaces, and also announces a public meeting webinar to receive comment on these proposed standards and associated analyses and results.
Original sourceXML (1.2 MB)PDF (1.6 MB)
Other documents for the same rulemaking
References: 42 extracted, 22 linked to papers
Page 1Download these results: CSV · JSON
Davis, L.W., and G.E. Metcalf (2016): “Does better information lead to better choices? Evidence from energy-efficiency labels,” Journal of the Association of Environmental and Resource Economists, 3(3), 589-625.
Davis and Metcalf \169\ conducted an experiment demonstrating that the nature of the information available to consumers from EnergyGuide labels posted on air conditioning equipment results in an inefficient allocation of energy efficiency across households with different usage levels.
Attari, S.Z., M.L. DeKay, C.I. Davidson, and W. Bruine de Bruin (2010): “Public perceptions of energy consumption and savings.” Proceedings of the National Academy of Sciences 107(37), 16054-16059
Attari, Krantz, and Weber \170\ show that consumers tend to underestimate the energy use of large energy-intensive appliances, but overestimate the energy use of small appliances.
Houde, S. (2018): “How Consumers Respond to Environmental Certification and the Value of Energy Information,” The RAND Journal of Economics, 49 (2), 453-477
A study by Houde \171\ indicates that there is a significant subset of consumers that appear to purchase appliances without taking into account their energy efficiency and operating costs at all. --------------------------------------------------------------------------- ---------------------------------------------------------------------------
Vernon, D., and Meier, A. (2012). “Identification and quantification of principal-agent problems affecting energy efficiency investments and use decisions in the trucking industry,” Energy Policy, 49, 266-273.
Blum, H. and Sathaye, J. (2010). “Quantitative Analysis of the Principal-Agent Problem in Commercial Buildings in the U.S.: Focus on Central Space Heating and Cooling,” Lawrence Berkeley National Laboratory, LBNL-3557E.
Prindle, B., Sathaye, J., Murtishaw, S., Crossley, D., Watt, G., Hughes, J., and de Visser, E. (2007). “Quantifying the effects of market failures in the end-use of energy,” Final Draft Report Prepared for International Energy Agency.
research reportNot linked to a paper · fn 174
International Energy Agency (IEA). (2007). Mind the Gap: Quantifying Principal-Agent Problems in Energy Efficiency. OECD Pub.
It is common to see conflicting goals across various actors within the same organization as well as information asymmetries between market actors in the energy efficiency context in commercial building construction.\176\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------
DeCanio, S.J. (1994). “Agency and control problems in US corporations: the case of energy-efficient investment projects,” Journal of the Economics of Business, 1(1), 105-124.
Second, the nature of the organizational structure and design can influence priorities for capital budgeting, resulting in choices that do not necessarily maximize profitability.\177\ Even factors as simple as unmotivated staff or lack of priority-setting and/or a lack of a long-term energy strategy can have a sizable effect on the likelihood that an energy efficient investment will be undertaken.\178\ U.S.
DeCanio, S.J. (1998). “The Efficiency Paradox: Bureaucratic and Organizational Barriers to Profitable Energy-Saving Investments,” Energy Policy, 26(5), 441-454.
One study in particular showed evidence of substantial gains in energy efficiency that could have been achieved without negative repercussions on profitability, but the investments had not been undertaken by firms.\188\ The study found that multiple organizational and institutional factors caused firms to require shorter payback periods and higher returns than the cost of capital for alternative investments of similar risk.
Andersen, S.T., and Newell, R.G. (2004). “Information programs for technology adoption: the case of energy-efficiency audits,” Resource and Energy Economics, 26, 27-50.
Another study demonstrated similar results with firms requiring very short payback periods of 1-2 years in order to adopt energy-saving projects, implying hurdle rates of 50 to 100 percent, despite the potential economic benefits.\189\ A number of other case studies similarly demonstrate the existence of market failures preventing the adoption of energy- efficient technologies in a variety of commercial sectors around the world, including office buildings,\190\ supermarkets,\191\ and the electric motor market.\192\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------
Klemick, H., Kopits, E., Wolverton, A. (2017). “Potential Barriers to Improving Energy Efficiency in Commercial Buildings: The Case of Supermarket Refrigeration,” Journal of Benefit-Cost Analysis, 8(1), 115-145.
Another study demonstrated similar results with firms requiring very short payback periods of 1-2 years in order to adopt energy-saving projects, implying hurdle rates of 50 to 100 percent, despite the potential economic benefits.\189\ A number of other case studies similarly demonstrate the existence of market failures preventing the adoption of energy- efficient technologies in a variety of commercial sectors around the world, including office buildings,\190\ supermarkets,\191\ and the electric motor market.\192\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------
Fujita, S., Estimating Price Elasticity using Market-Level Appliance Data. LBNL-188289 (August 2015)
A regression analysis estimated these terms separately from each other and found that the price elasticity of demand for several appliances is on average -0.45.\210\ Thus, for example, a price increase of 10 percent would result in a shipments decrease of 4.5 percent, all other factors held constant.
Scott Pigg, Electricity Use by New Furnaces: A Wisconsin Field Study, Seventh Wave (formerly Energy Center of Wisconsin) (2003)
research reportNot linked to a paper · fn 193
Livingston, O.V., S.R. Bender, M.J. Scott, and R.W. Schultz. ImSET 4.0: Impact of Sector Energy Technologies Model Description and User's Guide. 2015. Pacific Northwest National Laboratory: Richland, WA. PNNL-24563
research reportNot linked to a paper · fn 263
P.C. Reiss and M.W. White (2005), Household Electricity Demand, Revisited. The Review of Economic Studies, 72 (3), 853-883
However, DOE's current analysis does not explicitly control for heterogeneity in consumer preferences, preferences across subcategories of products or specific features, or consumer price sensitivity variation according to household income.\275\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------
U.S. Census Bureau's Annual Survey of Manufactures: 2018-2019 (Available at www.census.gov/programs-surveys/asm/data/tables.html) (Last accessed Oct. 19, 2021).
datasetNot linked to a paper · fn 266
U.S. Bureau of Labor Statistics, Employer Costs for Employee Compensation (June 17, 2021) (Available at: www.bls.gov/news.release/pdf/ecec.pdf)
datasetNot linked to a paper · fn 267
U.S. Office of Management and Budget, Circular A-4: Regulatory Analysis (September 17, 2003)
government reportNot linked to a paper · fn 270
U.S. Department of Energy Compliance Certification Management System ("CCMS"). (Available at: www.regulations.doe.gov/certification-data/)
datasetNot linked to a paper · fn 269
California Energy Commission's Modernized Appliance Efficiency Database System ("MAEDbS") (Available at: cacertappliances.energy.ca.gov/Pages/Search/AdvancedSearch.aspx)
datasetNot linked to a paper · fn 277
AHRI's Directory of Certified Product Performance (Available at: www.ahridirectory.org/Search/SearchHome)
datasetNot linked to a paper · fn 278
D&B Hoovers | Company Information | Industry Information | Lists, app.dnbhoovers.com/
datasetNot linked to a paper · fn 279
Gas Technology Institute (GTI), Technical Analysis of DOE Supplemental Notice of Proposed Rulemaking on Residential Furnace Minimum Efficiencies
research reportNot linked to a paper · fn 45
Taylor, M. and K.S. Fujita, Accounting for Technological Change in Regulatory Impact Analyses: The Learning Curve Technique, Lawrence Berkeley National Laboratory, Report No. LBNL-6195E (2013)
DOE's learning curve methodology was developed by examining the literature on accounting for technological change and empirical studies of energy technology learning rates.\88\ DOE utilized the most extensive time series data available specific to residential furnaces. --------------------------------------------------------------------------- ---------------------------------------------------------------------------
Lutz, J., A. Hopkins, V. Letschert, V. Franco, and A. Sturges, Using national survey data to estimate lifetimes of residential appliances, HVAC&R Research (2011) 17(5): pp. 28
DOE conducted an analysis of furnace lifetimes based on the methodology described in a recent journal paper.\143\ For this analysis, DOE relied on RECS 1990, 1993, 2001, 2005, 2009, and 2015.\144\ DOE also used the U.S.
Jakob, F.E., J.J. Crisafulli, et al., Assessment of Technology for Improving the Efficiency of Residential Gas Furnaces and Boilers, Volume I and II—Appendices (September 1994) Gas Research Institute, Report No. GRI-94/0175
research reportNot linked to a paper · fn 142
Sorrell, Steven, et al., Empirical Estimates of the Direct Rebound Effect: A Review, 37 Energy Policy 1356-71 (2009)
DOE examined a 2009 review of empirical estimates of the rebound effect for various energy-using products.\127\ This review concluded that the econometric and quasi-experimental studies suggest a mean value for the direct rebound effect for household heating of around 20 percent.
Steven Nadel, "The Rebound Effect: Large or Small?" ACEEE White Paper (August 2012)
research reportNot linked to a paper · fn 128
Brinda Thomas and Ines Azevedo, Estimating Direct and Indirect Rebound Effects for U.S. Households with Input-Output Analysis, Part 1: Theoretical Framework, 86 Ecological Econ. 199-201 (2013)
DOE also examined a 2012 ACEEE paper \128\ and a 2013 paper by Thomas and Azevedo.\129\ Both of these publications examined the same studies that were reviewed by Sorrell, as well as Greening et al.,\130\ and identified methodological problems with some of the studies.
Lorna A. Greening, et al., Energy Efficiency and Consumption—The Rebound Effect—A Survey, 28 Energy Policy 389-401 (2002)
DOE also examined a 2012 ACEEE paper \128\ and a 2013 paper by Thomas and Azevedo.\129\ Both of these publications examined the same studies that were reviewed by Sorrell, as well as Greening et al.,\130\ and identified methodological problems with some of the studies.
Lekov A., V. Franco, G. Wong-Parodi, J. McMahon, P. Chan, Economics of residential gas furnaces and water heaters in US new construction market, Energy Efficiency (September 2010) Volume 3, Issue 3, pp 203-222
(i) New Construction or New Owner Installations It is common practice in new construction, when possible, to avoid vertical venting in order to limit roof penetrations and reduce potential liability issues (e.g., water leakage through new roof penetrations).\118\ Condensing furnaces have the flexibility of being vented either horizontally or vertically.
Ward, D.O., Clark, C.D., Jensen, K.L., Yen, S.T., & Russell, C.S. (2011): Factors influencing willingness-to pay for the ENERGY STAR label, Energy Policy, 39 (3), 1450-1458.
There are consumers who are willing to pay a premium for more energy-efficient products because they are environmentally conscious.\165\ There are also several behavioral factors that can influence the purchasing decisions of complicated multi-attribute products, such as furnaces.
Thaler, R.H., and Bernartzi, S. (2004). Save More Tomorrow: Using Behavioral Economics in Increase Employee Savings, Journal of Political Economy 112(1), S164-S187.
Consumers or decision makers also face a variety of other behavioral phenomena including loss aversion, sensitivity to information salience, and other forms of bounded rationality.\167\ Thaler, who won the Nobel Prize in Economics in 2017 for his contributions to behavioral economics, and Sunstein point out that these behavioral factors are strongest when the decisions are complex and infrequent, when feedback on the decision is muted and slow, and when there is a high degree of information asymmetry.\168\ These characteristics describe almost all purchasing situations of appliances and equipment, including furnaces.
Thaler, R.H., and Sunstein, C.R. (2008). Nudge: Improving Decisions on Health, Wealth, and Happiness. New Haven, CT: Yale University Press.
bookNot linked to a paper · fn 168
Fujita, S., Commercial, Industrial, and Institutional Discount Rate Estimation for Efficiency Standards Analysis: Sector-Level Data 1998-2018
DOE's commercial discount rate approach is based on the methodology described in a LBNL report, and the distribution varies by business activity.\154\ The average rate for NWGFs used in commercial applications in this NOPR analysis, across all business activity, is 6.7 percent. --------------------------------------------------------------------------- ---------------------------------------------------------------------------
Oak Ridge National Laboratory, Condensing Furnace Venting Part 2: Evaluation of Same-Chimney Vent Systems for Condensing Furnaces and Natural Draft Water Heaters (February 2015)
Interagency Working Group on Social Cost of Greenhouse Gases, Technical Support Document: Social Cost of Carbon, Methane, and Nitrous Oxide. Interim Estimates Under Executive Order 13990, Washington, DC (February 2021)
government reportNot linked to a paper · fn 8
Richard Campbell, National Fire Protection Association Fire Analysis and Research Division, Home Heating Fires Supporting Tables (January 2021) p. 7
research reportNot linked to a paper · fn 42
FEMA, Heating Fires in Residential Buildings (2010-2012), Topical Fire Report Series (December 2014) p. 7
government reportNot linked to a paper · fn 44
AGA presented information ... HTR Engineering furnace sizing study
research reportNot linked to a paper · IV.F.1 Furnace Sizing Requirements Based on ACCA Manual J and Manual S
Energy Conservation Standards Rulemaking Peer Review Report (2007), available at www.energy.gov/eere/buildings/downloads/energy-conservation-standards-rulemaking-peer-review-report-0
research reportNot linked to a paper · fn 280
Review of Methods for Setting Building and Equipment Performance Standards, National Academies of Sciences, Engineering, and Medicine, www.nationalacademies.org/our-work/review-of-methods-for-setting-building-and-equipment-performance-standards
research reportNot linked to a paper · fn 281