{"document":{"doc_id":77139,"source":"fr_rule","org":"DEPARTMENT OF ENERGY","doc_type":"Proposed Rule","title":"Energy Conservation Program: Energy Conservation Standards for Consumer Furnaces","date":"2022-07-07","url":"https://www.federalregister.gov/documents/2022/07/07/2022-13108/energy-conservation-program-energy-conservation-standards-for-consumer-furnaces","source_native_id":"2022-13108","status":"fetched","abstract":"The Energy Policy and Conservation Act, as amended (\"EPCA\"), prescribes energy conservation standards for various consumer products and certain commercial and industrial equipment, including consumer furnaces. EPCA also requires the Department of Energy (\"DOE\" or \"the Department\") to periodically determine whether more-stringent, amended standards would be technologically feasible and economically justified, and would result in significant energy savings. In this notice of proposed rulemaking (\"NOPR\"), DOE proposes amended energy conservation standards for non-weatherized gas furnaces and mobile home gas furnaces, and also announces a public meeting webinar to receive comment on these proposed standards and associated analyses and results.","action":"Notice of proposed rulemaking and request for comment."},"dockets":["EERE-2014-BT-STD-0031"],"rins":["RIN 1904-AD20"],"related":[{"doc_id":83673,"source":"ria","org":"EERE","doc_type":"regulatory_impact_analysis","title":"2014-09-23  Ex parte communication record of the meeting between AGA and DOE representatives on September 12, 2014 and Correction to memorandum (includes email cover letters, memorandum, Furnace Standard Stakeholder Discussion Document, Copy of Fuel Switching Impact Analysis Model, and Corrected ex parte communication memorandum)","date":"2014-09-24"},{"doc_id":77311,"source":"fr_rule","org":"DEPARTMENT OF ENERGY","doc_type":"Proposed Rule","title":"Energy Conservation Program for Consumer Products: Energy Conservation Standards for Residential Furnaces","date":"2014-10-30"},{"doc_id":83733,"source":"ria","org":"EERE","doc_type":"technical_support_document","title":"2015-02-10  Technical Support Document:  Energy Efficiency Program for Consumer Products and Commercial and Industrial Equipment: Residential Furnaces","date":"2015-02-24"},{"doc_id":77306,"source":"fr_rule","org":"DEPARTMENT OF ENERGY","doc_type":"Proposed Rule","title":"Energy Conservation Program for Consumer Products: Energy Conservation Standards for Residential Furnaces","date":"2015-03-12"},{"doc_id":77303,"source":"fr_rule","org":"DEPARTMENT OF ENERGY","doc_type":"Proposed Rule","title":"Energy Conservation Program for Consumer Products: Energy Conservation Standards for Residential Furnaces","date":"2015-05-20"},{"doc_id":77291,"source":"fr_rule","org":"DEPARTMENT OF ENERGY","doc_type":"Proposed Rule","title":"Energy Conservation Program for Consumer Products: Energy Conservation Standards for Residential Furnaces","date":"2015-09-14"},{"doc_id":77294,"source":"fr_rule","org":"DEPARTMENT OF ENERGY","doc_type":"Proposed Rule","title":"Energy Conservation Program: Energy Conservation Standards for Residential Furnaces","date":"2015-10-23"},{"doc_id":83680,"source":"ria","org":"EERE","doc_type":"regulatory_impact_analysis","title":"2016-08-30 SNOPR Analytical Tools:  Residential Furnaces National Impact Analysis","date":"2016-09-02"},{"doc_id":83687,"source":"ria","org":"EERE","doc_type":"regulatory_impact_analysis","title":"2016-08-30 SNOPR Analytical Tools:  Residential Furnaces National Impact Analysis (NIA) - Plus Standby","date":"2016-09-02"},{"doc_id":83694,"source":"ria","org":"EERE","doc_type":"regulatory_impact_analysis","title":"2016-08-30 SNOPR Analytical Tools:  Residential Furnaces National Impact Analysis - Plus AFUE","date":"2016-09-02"},{"doc_id":83708,"source":"ria","org":"EERE","doc_type":"technical_support_document","title":"2016-08-30  SNOPR Technical Support Document:  Energy Efficiency Program for Consumer Products and Commercial and Industrial Equipment: Residential Furnaces","date":"2016-09-02"},{"doc_id":23057,"source":"ria","org":"Federal Motor Carrier Safety Administration","doc_type":"regulatory_impact_analysis","title":"RIA cited in FR 2016-20934: Federal Motor Vehicle Safety Standards; Federal Motor Carrier Safety Regulations; Parts and Accessories Necessary for Safe Operation; Speed Limiting Devices","date":"2016-09-07"},{"doc_id":130206,"source":"docket_item","org":"EERE","doc_type":"review_record","title":"2016-06-21 OMB Executive Order 12866 Meeting Record","date":"2016-09-22"},{"doc_id":77276,"source":"fr_rule","org":"DEPARTMENT OF ENERGY","doc_type":"Proposed Rule","title":"Energy Conservation Program: Energy Conservation Standards for Residential Furnaces","date":"2016-09-23"},{"doc_id":83727,"source":"ria","org":"EERE","doc_type":"technical_support_document","title":"2016-10-26  DOE response to AHRI questions regarding Table 7.3.2 in the SNOPR TSD","date":"2016-10-27"},{"doc_id":83722,"source":"ria","org":"EERE","doc_type":"technical_support_document","title":"2016-11-14  Rheem question regarding the SNOPR TSD and DOE response","date":"2016-11-14"},{"doc_id":77266,"source":"fr_rule","org":"DEPARTMENT OF ENERGY","doc_type":"Proposed Rule","title":"Energy Conservation Program: Energy Conservation Standards for Residential Furnaces","date":"2016-12-05"},{"doc_id":83701,"source":"ria","org":"EERE","doc_type":"regulatory_analysis","title":"2017-03-14  Executive correspondence from APGA, Spire Inc., ACCA, et al., to Secretary Perry requesting correction of regulatory analysis before final actions are taken.","date":"2017-04-03"},{"doc_id":22979,"source":"ria","org":"DEPARTMENT OF ENERGY","doc_type":"regulatory_impact_analysis","title":"RIA cited in FR 2017-14079: Energy Conservation Program: Energy Conservation Standards for Walk-In Cooler and Freezer Refrigeration Systems","date":"2017-07-10"},{"doc_id":22982,"source":"ria","org":"DEPARTMENT OF ENERGY","doc_type":"regulatory_impact_analysis","title":"RIA cited in FR 2017-14079: Energy Conservation Program: Energy Conservation Standards for Walk-In Cooler and Freezer Refrigeration Systems","date":"2017-07-10"},{"doc_id":22683,"source":"ria","org":"DEPARTMENT OF ENERGY","doc_type":"regulatory_impact_analysis","title":"RIA cited in FR 2019-26350: Energy Conservation Program: Energy Conservation Standards for Portable Air Conditioners","date":"2020-01-10"},{"doc_id":22685,"source":"ria","org":"DEPARTMENT OF ENERGY","doc_type":"regulatory_impact_analysis","title":"RIA cited in FR 2019-26350: Energy Conservation Program: Energy Conservation Standards for Portable Air Conditioners","date":"2020-01-10"},{"doc_id":83740,"source":"ria","org":"EERE","doc_type":"technical_support_document","title":"2022-06  Technical Support Document: Energy Efficiency Program For Consumer Products And Commercial And Industrial Equipment: Consumer Furnaces (including Supplemental Appendix 8N, attached)","date":"2022-06-13"},{"doc_id":77132,"source":"fr_rule","org":"DEPARTMENT OF ENERGY","doc_type":"Proposed Rule","title":"Energy Conservation Program: Energy Conservation Standards for Consumer Furnaces","date":"2022-08-30"},{"doc_id":22256,"source":"ria","org":"DEPARTMENT OF ENERGY","doc_type":"regulatory_impact_analysis","title":"RIA cited in FR 2023-03436: Energy Conservation Program: Energy Conservation Standards for Refrigerators, Refrigerator-Freezers, and Freezers","date":"2023-02-27"},{"doc_id":22266,"source":"ria","org":"DEPARTMENT OF ENERGY","doc_type":"regulatory_impact_analysis","title":"RIA cited in FR 2023-03436: Energy Conservation Program: Energy Conservation Standards for Refrigerators, Refrigerator-Freezers, and Freezers","date":"2023-02-27"},{"doc_id":22267,"source":"ria","org":"DEPARTMENT OF ENERGY","doc_type":"regulatory_impact_analysis","title":"RIA cited in FR 2023-03436: Energy Conservation Program: Energy Conservation Standards for Refrigerators, Refrigerator-Freezers, and Freezers","date":"2023-02-27"},{"doc_id":22270,"source":"ria","org":"DEPARTMENT OF ENERGY","doc_type":"regulatory_impact_analysis","title":"RIA cited in FR 2023-03436: Energy Conservation Program: Energy Conservation Standards for Refrigerators, Refrigerator-Freezers, and Freezers","date":"2023-02-27"},{"doc_id":22271,"source":"ria","org":"DEPARTMENT OF ENERGY","doc_type":"regulatory_impact_analysis","title":"RIA cited in FR 2023-06499: Energy Conservation Program: Energy Conservation Standards for Air Cleaners; Final Rule","date":"2023-04-11"},{"doc_id":83715,"source":"ria","org":"EERE","doc_type":"technical_support_document","title":"2023-09  Technical Support Document:  Energy Efficiency Program for Consumer Products and Commercial and Industrial Equipment:  Consumer Furnaces, September 2023","date":"2023-09-29"},{"doc_id":128057,"source":"docket_item","org":"EERE","doc_type":"review_record","title":"Documentation of Changes between the draft Final Rule submitted to the Office of Information and Regulatory Affairs (OIRA) and the issued Final Rule","date":"2023-09-29"},{"doc_id":77076,"source":"fr_rule","org":"DEPARTMENT OF ENERGY","doc_type":"Rule","title":"Energy Conservation Program: Energy Conservation Standards for Consumer Furnaces","date":"2023-12-18"}],"references":[{"citation_id":455463,"raw_reference":"Davis, L.W., and G.E. Metcalf (2016): “Does better information lead to better choices? Evidence from energy-efficiency labels,” Journal of the Association of Environmental and Resource Economists, 3(3), 589-625.","cited_authors":"Davis, L.W.; Metcalf, G.E.","cited_year":"2016","cited_title":"Does better information lead to better choices? Evidence from energy-efficiency labels","cited_venue":"Journal of the Association of Environmental and Resource Economists","cited_doi":"10.3386/w20720","cited_url":"www.journals.uchicago.edu/doi/full/10.1086/686252","ref_kind":"journal_article","section":"fn 169","page":null,"context_sentence":"Davis and Metcalf \\169\\ conducted an experiment demonstrating that the nature of the information available to consumers from EnergyGuide labels posted on air conditioning equipment results in an inefficient allocation of energy efficiency across households with different usage levels.","paper_id":6206,"paper_title":"Does Better Information Lead to Better Choices? Evidence from Energy-Efficiency Labels","paper_year":2014,"paper_doi":"10.3386/w20720"},{"citation_id":455464,"raw_reference":"Attari, S.Z., M.L. DeKay, C.I. Davidson, and W. Bruine de Bruin (2010): “Public perceptions of energy consumption and savings.” Proceedings of the National Academy of Sciences 107(37), 16054-16059","cited_authors":"Attari, S.Z.; DeKay, M.L.; Davidson, C.I.; Bruine de Bruin, W.","cited_year":"2010","cited_title":"Public perceptions of energy consumption and savings","cited_venue":"Proceedings of the National Academy of Sciences","cited_doi":"10.1073/pnas.1001509107","cited_url":"www.pnas.org/content/107/37/16054","ref_kind":"journal_article","section":"fn 170","page":null,"context_sentence":"Attari, Krantz, and Weber \\170\\ show that consumers tend to underestimate the energy use of large energy-intensive appliances, but overestimate the energy use of small appliances.","paper_id":51528,"paper_title":"Public perceptions of energy consumption and savings","paper_year":2010,"paper_doi":"10.1073/pnas.1001509107"},{"citation_id":455465,"raw_reference":"Houde, S. (2018): “How Consumers Respond to Environmental Certification and the Value of Energy Information,” The RAND Journal of Economics, 49 (2), 453-477","cited_authors":"Houde, S.","cited_year":"2018","cited_title":"How Consumers Respond to Environmental Certification and the Value of Energy Information","cited_venue":"The RAND Journal of Economics","cited_doi":"10.1111/1756-2171.12231","cited_url":"onlinelibrary.wiley.com/doi/full/10.1111/1756-2171.12231","ref_kind":"journal_article","section":"fn 171","page":null,"context_sentence":"A study by Houde \\171\\ indicates that there is a significant subset of consumers that appear to purchase appliances without taking into account their energy efficiency and operating costs at all. --------------------------------------------------------------------------- ---------------------------------------------------------------------------","paper_id":5710,"paper_title":"How consumers respond to product certification and the value of energy information","paper_year":2018,"paper_doi":"10.1111/1756-2171.12231"},{"citation_id":455466,"raw_reference":"Vernon, D., and Meier, A. (2012). “Identification and quantification of principal-agent problems affecting energy efficiency investments and use decisions in the trucking industry,” Energy Policy, 49, 266-273.","cited_authors":"Vernon, D.; Meier, A.","cited_year":"2012","cited_title":"Identification and quantification of principal-agent problems affecting energy efficiency investments and use decisions in the trucking industry","cited_venue":"Energy Policy","cited_doi":"10.1016/j.enpol.2012.06.016","cited_url":null,"ref_kind":"journal_article","section":"fn 172","page":null,"context_sentence":null,"paper_id":4467,"paper_title":"Identification and quantification of principal–agent problems affecting energy efficiency investments and use decisions in the trucking industry","paper_year":2012,"paper_doi":"10.1016/j.enpol.2012.06.016"},{"citation_id":455467,"raw_reference":"Blum, H. and Sathaye, J. (2010). “Quantitative Analysis of the Principal-Agent Problem in Commercial Buildings in the U.S.: Focus on Central Space Heating and Cooling,” Lawrence Berkeley National Laboratory, LBNL-3557E.","cited_authors":"Blum, H.; Sathaye, J.","cited_year":"2010","cited_title":"Quantitative Analysis of the Principal-Agent Problem in Commercial Buildings in the U.S.: Focus on Central Space Heating and Cooling","cited_venue":"Lawrence Berkeley National Laboratory, LBNL-3557E","cited_doi":"10.2172/983799","cited_url":"escholarship.org/uc/item/6p1525mg","ref_kind":"research_report","section":"fn 173","page":null,"context_sentence":null,"paper_id":4468,"paper_title":"Quantitative Analysis of the Principal-Agent Problem in Commercial Buildings in the U.S.: Focus on Central Space Heating and Cooling","paper_year":2010,"paper_doi":"10.2172/983799"},{"citation_id":455468,"raw_reference":"Prindle, B., Sathaye, J., Murtishaw, S., Crossley, D., Watt, G., Hughes, J., and de Visser, E. (2007). “Quantifying the effects of market failures in the end-use of energy,” Final Draft Report Prepared for International Energy Agency.","cited_authors":"Prindle, B.; Sathaye, J.; Murtishaw, S.; Crossley, D.; Watt, G.; Hughes, J.; de Visser, E.","cited_year":"2007","cited_title":"Quantifying the effects of market failures in the end-use of energy","cited_venue":"International Energy Agency","cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"fn 174","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":455469,"raw_reference":"International Energy Agency (IEA). (2007). Mind the Gap: Quantifying Principal-Agent Problems in Energy Efficiency. OECD Pub.","cited_authors":"International Energy Agency","cited_year":"2007","cited_title":"Mind the Gap: Quantifying Principal-Agent Problems in Energy Efficiency","cited_venue":"OECD Publishing","cited_doi":"10.1787/9789264038950-en","cited_url":"www.iea.org/reports/mind-the-gap","ref_kind":"research_report","section":"fn 176","page":null,"context_sentence":"It is common to see conflicting goals across various actors within the same organization as well as information asymmetries between market actors in the energy efficiency context in commercial building construction.\\176\\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------","paper_id":4471,"paper_title":"Mind the Gap: Quantifying Principal-Agent Problems in Energy Efficiency","paper_year":2007,"paper_doi":"10.1787/9789264038950-en"},{"citation_id":455470,"raw_reference":"DeCanio, S.J. (1994). “Agency and control problems in US corporations: the case of energy-efficient investment projects,” Journal of the Economics of Business, 1(1), 105-124.","cited_authors":"DeCanio, S.J.","cited_year":"1994","cited_title":"Agency and control problems in US corporations: the case of energy-efficient investment projects","cited_venue":"Journal of the Economics of Business","cited_doi":"10.1080/758540502","cited_url":null,"ref_kind":"journal_article","section":"fn 177","page":null,"context_sentence":"Second, the nature of the organizational structure and design can influence priorities for capital budgeting, resulting in choices that do not necessarily maximize profitability.\\177\\ Even factors as simple as unmotivated staff or lack of priority-setting and/or a lack of a long-term energy strategy can have a sizable effect on the likelihood that an energy efficient investment will be undertaken.\\178\\ U.S.","paper_id":4472,"paper_title":"Agency and Control Problems in US Corporations: The Case of Energy-efficient Investment Projects","paper_year":1994,"paper_doi":"10.1080/758540502"},{"citation_id":455471,"raw_reference":"DeCanio, S.J. (1998). “The Efficiency Paradox: Bureaucratic and Organizational Barriers to Profitable Energy-Saving Investments,” Energy Policy, 26(5), 441-454.","cited_authors":"DeCanio, S.J.","cited_year":"1998","cited_title":"The Efficiency Paradox: Bureaucratic and Organizational Barriers to Profitable Energy-Saving Investments","cited_venue":"Energy Policy","cited_doi":"10.1016/s0301-4215(97)00152-3","cited_url":null,"ref_kind":"journal_article","section":"fn 188","page":null,"context_sentence":"One study in particular showed evidence of substantial gains in energy efficiency that could have been achieved without negative repercussions on profitability, but the investments had not been undertaken by firms.\\188\\ The study found that multiple organizational and institutional factors caused firms to require shorter payback periods and higher returns than the cost of capital for alternative investments of similar risk.","paper_id":4483,"paper_title":"The efficiency paradox: bureaucratic and organizational barriers to profitable energy-saving investments","paper_year":1998,"paper_doi":"10.1016/s0301-4215(97)00152-3"},{"citation_id":455472,"raw_reference":"Andersen, S.T., and Newell, R.G. (2004). “Information programs for technology adoption: the case of energy-efficiency audits,” Resource and Energy Economics, 26, 27-50.","cited_authors":"Andersen, S.T.; Newell, R.G.","cited_year":"2004","cited_title":"Information programs for technology adoption: the case of energy-efficiency audits","cited_venue":"Resource and Energy Economics","cited_doi":"10.1016/j.reseneeco.2003.07.001","cited_url":null,"ref_kind":"journal_article","section":"fn 189","page":null,"context_sentence":"Another study demonstrated similar results with firms requiring very short payback periods of 1-2 years in order to adopt energy-saving projects, implying hurdle rates of 50 to 100 percent, despite the potential economic benefits.\\189\\ A number of other case studies similarly demonstrate the existence of market failures preventing the adoption of energy- efficient technologies in a variety of commercial sectors around the world, including office buildings,\\190\\ supermarkets,\\191\\ and the electric motor market.\\192\\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------","paper_id":4482,"paper_title":"Information programs for technology adoption: the case of energy-efficiency audits","paper_year":2003,"paper_doi":"10.1016/j.reseneeco.2003.07.001"},{"citation_id":455473,"raw_reference":"Klemick, H., Kopits, E., Wolverton, A. (2017). “Potential Barriers to Improving Energy Efficiency in Commercial Buildings: The Case of Supermarket Refrigeration,” Journal of Benefit-Cost Analysis, 8(1), 115-145.","cited_authors":"Klemick, H.; Kopits, E.; Wolverton, A.","cited_year":"2017","cited_title":"Potential Barriers to Improving Energy Efficiency in Commercial Buildings: The Case of Supermarket Refrigeration","cited_venue":"Journal of Benefit-Cost Analysis","cited_doi":"10.1017/bca.2017.4","cited_url":null,"ref_kind":"journal_article","section":"fn 191","page":null,"context_sentence":"Another study demonstrated similar results with firms requiring very short payback periods of 1-2 years in order to adopt energy-saving projects, implying hurdle rates of 50 to 100 percent, despite the potential economic benefits.\\189\\ A number of other case studies similarly demonstrate the existence of market failures preventing the adoption of energy- efficient technologies in a variety of commercial sectors around the world, including office buildings,\\190\\ supermarkets,\\191\\ and the electric motor market.\\192\\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------","paper_id":4339,"paper_title":"Potential Barriers to Improving Energy Efficiency in Commercial Buildings: The Case of Supermarket Refrigeration","paper_year":2017,"paper_doi":"10.1017/bca.2017.4"},{"citation_id":455474,"raw_reference":"Fujita, S., Estimating Price Elasticity using Market-Level Appliance Data. LBNL-188289 (August 2015)","cited_authors":"Fujita, S.","cited_year":"2015","cited_title":"Estimating Price Elasticity using Market-Level Appliance Data","cited_venue":"Lawrence Berkeley National Laboratory, LBNL-188289","cited_doi":"10.2172/1236368","cited_url":"eta-publications.lbl.gov/sites/default/files/lbnl-188289.pdf","ref_kind":"research_report","section":"fn 210","page":null,"context_sentence":"A regression analysis estimated these terms separately from each other and found that the price elasticity of demand for several appliances is on average -0.45.\\210\\ Thus, for example, a price increase of 10 percent would result in a shipments decrease of 4.5 percent, all other factors held constant.","paper_id":4956,"paper_title":"Estimating Price Elasticity using Market-Level Appliance Data","paper_year":2015,"paper_doi":"10.2172/1236368"},{"citation_id":455475,"raw_reference":"Scott Pigg, Electricity Use by New Furnaces: A Wisconsin Field Study, Seventh Wave (formerly Energy Center of Wisconsin) (2003)","cited_authors":"Pigg, Scott","cited_year":"2003","cited_title":"Electricity Use by New Furnaces: A Wisconsin Field Study","cited_venue":"Seventh Wave (formerly Energy Center of Wisconsin)","cited_doi":null,"cited_url":"www.proctoreng.com/dnld/WIDOE2013.pdf","ref_kind":"research_report","section":"fn 193","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":455476,"raw_reference":"Livingston, O.V., S.R. Bender, M.J. Scott, and R.W. Schultz. ImSET 4.0: Impact of Sector Energy Technologies Model Description and User's Guide. 2015. Pacific Northwest National Laboratory: Richland, WA. PNNL-24563","cited_authors":"Livingston, O.V.; Bender, S.R.; Scott, M.J.; Schultz, R.W.","cited_year":"2015","cited_title":"ImSET 4.0: Impact of Sector Energy Technologies Model Description and User's Guide","cited_venue":"Pacific Northwest National Laboratory, PNNL-24563","cited_doi":null,"cited_url":"www.pnnl.gov/main/publications/external/technical_reports/PNNL-24563.pdf","ref_kind":"research_report","section":"fn 263","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":455618,"raw_reference":"P.C. Reiss and M.W. White (2005), Household Electricity Demand, Revisited. The Review of Economic Studies, 72 (3), 853-883","cited_authors":"P.C. Reiss; M.W. White","cited_year":"2005","cited_title":"Household Electricity Demand, Revisited","cited_venue":"The Review of Economic Studies","cited_doi":"10.1111/0034-6527.00354","cited_url":"academic.oup.com/restud/article/72/3/853/1557538","ref_kind":"journal_article","section":"fn 275","page":null,"context_sentence":"However, DOE's current analysis does not explicitly control for heterogeneity in consumer preferences, preferences across subcategories of products or specific features, or consumer price sensitivity variation according to household income.\\275\\ --------------------------------------------------------------------------- ---------------------------------------------------------------------------","paper_id":407,"paper_title":"Household Electricity Demand, Revisited","paper_year":2005,"paper_doi":"10.1111/0034-6527.00354"},{"citation_id":455619,"raw_reference":"U.S. Census Bureau's Annual Survey of Manufactures: 2018-2019 (Available at www.census.gov/programs-surveys/asm/data/tables.html) (Last accessed Oct. 19, 2021).","cited_authors":"U.S. Census Bureau","cited_year":"2019","cited_title":"Annual Survey of Manufactures: 2018-2019","cited_venue":"U.S. Census Bureau","cited_doi":null,"cited_url":"www.census.gov/programs-surveys/asm/data/tables.html","ref_kind":"dataset","section":"fn 266","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":455620,"raw_reference":"U.S. Bureau of Labor Statistics, Employer Costs for Employee Compensation (June 17, 2021) (Available at: www.bls.gov/news.release/pdf/ecec.pdf)","cited_authors":"U.S. Bureau of Labor Statistics","cited_year":"2021","cited_title":"Employer Costs for Employee Compensation","cited_venue":"U.S. Bureau of Labor Statistics","cited_doi":null,"cited_url":"www.bls.gov/news.release/pdf/ecec.pdf","ref_kind":"dataset","section":"fn 267","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":455621,"raw_reference":"U.S. Office of Management and Budget, Circular A-4: Regulatory Analysis (September 17, 2003)","cited_authors":"U.S. Office of Management and Budget","cited_year":"2003","cited_title":"Circular A-4: Regulatory Analysis","cited_venue":"Office of Management and Budget","cited_doi":null,"cited_url":"www.whitehouse.gov/sites/whitehouse.gov/files/omb/circulars/A4/a-4.pdf","ref_kind":"government_report","section":"fn 270","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":455622,"raw_reference":"U.S. Department of Energy Compliance Certification Management System (\"CCMS\"). (Available at: www.regulations.doe.gov/certification-data/)","cited_authors":"U.S. Department of Energy","cited_year":"2021","cited_title":"Compliance Certification Management System","cited_venue":"U.S. Department of Energy","cited_doi":null,"cited_url":"www.regulations.doe.gov/certification-data/","ref_kind":"dataset","section":"fn 269","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":455623,"raw_reference":"California Energy Commission's Modernized Appliance Efficiency Database System (\"MAEDbS\") (Available at: cacertappliances.energy.ca.gov/Pages/Search/AdvancedSearch.aspx)","cited_authors":"California Energy Commission","cited_year":"2021","cited_title":"Modernized Appliance Efficiency Database System","cited_venue":"California Energy Commission","cited_doi":null,"cited_url":"cacertappliances.energy.ca.gov/Pages/Search/AdvancedSearch.aspx","ref_kind":"dataset","section":"fn 277","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":455624,"raw_reference":"AHRI's Directory of Certified Product Performance (Available at: www.ahridirectory.org/Search/SearchHome)","cited_authors":"Air Conditioning, Heating, and Refrigeration Institute","cited_year":"2021","cited_title":"Directory of Certified Product Performance","cited_venue":"AHRI","cited_doi":null,"cited_url":"www.ahridirectory.org/Search/SearchHome","ref_kind":"dataset","section":"fn 278","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":455625,"raw_reference":"D&B Hoovers | Company Information | Industry Information | Lists, app.dnbhoovers.com/","cited_authors":"Dun & Bradstreet","cited_year":"2021","cited_title":"D&B Hoovers","cited_venue":"Dun & Bradstreet","cited_doi":null,"cited_url":"app.dnbhoovers.com/","ref_kind":"dataset","section":"fn 279","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":457575,"raw_reference":"Gas Technology Institute (GTI), Technical Analysis of DOE Supplemental Notice of Proposed Rulemaking on Residential Furnace Minimum Efficiencies","cited_authors":"Gas Technology Institute","cited_year":null,"cited_title":"Technical Analysis of DOE Supplemental Notice of Proposed Rulemaking on Residential Furnace Minimum Efficiencies","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"fn 45","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":457576,"raw_reference":"Taylor, M. and K.S. Fujita, Accounting for Technological Change in Regulatory Impact Analyses: The Learning Curve Technique, Lawrence Berkeley National Laboratory, Report No. LBNL-6195E (2013)","cited_authors":"Taylor, M.; Fujita, K.S.","cited_year":"2013","cited_title":"Accounting for Technological Change in Regulatory Impact Analyses: The Learning Curve Technique","cited_venue":"Lawrence Berkeley National Laboratory, Report No. LBNL-6195E","cited_doi":"10.2172/1171549","cited_url":"eta-publications.lbl.gov/sites/default/files/lbnl-6195e_.pdf","ref_kind":"research_report","section":"fn 88","page":null,"context_sentence":"DOE's learning curve methodology was developed by examining the literature on accounting for technological change and empirical studies of energy technology learning rates.\\88\\ DOE utilized the most extensive time series data available specific to residential furnaces. --------------------------------------------------------------------------- ---------------------------------------------------------------------------","paper_id":3935,"paper_title":"Accounting for Technological Change in Regulatory Impact Analyses: The Learning Curve Technique","paper_year":2013,"paper_doi":"10.2172/1171549"},{"citation_id":457577,"raw_reference":"Lutz, J., A. Hopkins, V. Letschert, V. Franco, and A. Sturges, Using national survey data to estimate lifetimes of residential appliances, HVAC&R Research (2011) 17(5): pp. 28","cited_authors":"Lutz, J.; Hopkins, A.; Letschert, V.; Franco, V.; Sturges, A.","cited_year":"2011","cited_title":"Using national survey data to estimate lifetimes of residential appliances","cited_venue":"HVAC&R Research","cited_doi":"10.1080/10789669.2011.558166","cited_url":"www.tandfonline.com/doi/abs/10.1080/10789669.2011.558166","ref_kind":"journal_article","section":"fn 143","page":null,"context_sentence":"DOE conducted an analysis of furnace lifetimes based on the methodology described in a recent journal paper.\\143\\ For this analysis, DOE relied on RECS 1990, 1993, 2001, 2005, 2009, and 2015.\\144\\ DOE also used the U.S.","paper_id":15144,"paper_title":"Using national survey data to estimate lifetimes of residential appliances","paper_year":2011,"paper_doi":"10.1080/10789669.2011.558166"},{"citation_id":457578,"raw_reference":"Jakob, F.E., J.J. Crisafulli, et al., Assessment of Technology for Improving the Efficiency of Residential Gas Furnaces and Boilers, Volume I and II—Appendices (September 1994) Gas Research Institute, Report No. GRI-94/0175","cited_authors":"Jakob, F.E.; Crisafulli, J.J.; Menkedick, J.R.; Fischer, R.D.; Philips, D.B.; Osbone, R.L.; Cross, J.C.; Whitacre, G.R.; Murray, J.G.; Sheppard, W.J.; DeWirth, D.W.; Thrasher, W.H.","cited_year":"1994","cited_title":"Assessment of Technology for Improving the Efficiency of Residential Gas Furnaces and Boilers, Volume I and II—Appendices","cited_venue":"Gas Research Institute, Report No. GRI-94/0175","cited_doi":null,"cited_url":"www.gti.energy/software-and-reports/","ref_kind":"research_report","section":"fn 142","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":457579,"raw_reference":"Sorrell, Steven, et al., Empirical Estimates of the Direct Rebound Effect: A Review, 37 Energy Policy 1356-71 (2009)","cited_authors":"Sorrell, Steven et al.","cited_year":"2009","cited_title":"Empirical Estimates of the Direct Rebound Effect: A Review","cited_venue":"Energy Policy","cited_doi":"10.1016/j.enpol.2008.11.026","cited_url":"www.sciencedirect.com/science/article/pii/S0301421508007131","ref_kind":"journal_article","section":"fn 127","page":null,"context_sentence":"DOE examined a 2009 review of empirical estimates of the rebound effect for various energy-using products.\\127\\ This review concluded that the econometric and quasi-experimental studies suggest a mean value for the direct rebound effect for household heating of around 20 percent.","paper_id":4957,"paper_title":"Empirical estimates of the direct rebound effect: A review","paper_year":2009,"paper_doi":"10.1016/j.enpol.2008.11.026"},{"citation_id":457580,"raw_reference":"Steven Nadel, \"The Rebound Effect: Large or Small?\" ACEEE White Paper (August 2012)","cited_authors":"Steven Nadel","cited_year":"2012","cited_title":"The Rebound Effect: Large or Small?","cited_venue":"ACEEE White Paper","cited_doi":null,"cited_url":"www.aceee.org/files/pdf/white-paper/rebound-large-and-small.pdf","ref_kind":"research_report","section":"fn 128","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":457581,"raw_reference":"Brinda Thomas and Ines Azevedo, Estimating Direct and Indirect Rebound Effects for U.S. Households with Input-Output Analysis, Part 1: Theoretical Framework, 86 Ecological Econ. 199-201 (2013)","cited_authors":"Brinda Thomas; Ines Azevedo","cited_year":"2013","cited_title":"Estimating Direct and Indirect Rebound Effects for U.S. Households with Input-Output Analysis, Part 1: Theoretical Framework","cited_venue":"Ecological Economics","cited_doi":"10.1016/j.ecolecon.2012.12.003","cited_url":"www.sciencedirect.com/science/article/pii/S0921800912004764","ref_kind":"journal_article","section":"fn 129","page":null,"context_sentence":"DOE also examined a 2012 ACEEE paper \\128\\ and a 2013 paper by Thomas and Azevedo.\\129\\ Both of these publications examined the same studies that were reviewed by Sorrell, as well as Greening et al.,\\130\\ and identified methodological problems with some of the studies.","paper_id":7012,"paper_title":"Estimating direct and indirect rebound effects for U.S. households with input–output analysis Part 1: Theoretical framework","paper_year":2013,"paper_doi":"10.1016/j.ecolecon.2012.12.003"},{"citation_id":457582,"raw_reference":"Lorna A. Greening, et al., Energy Efficiency and Consumption—The Rebound Effect—A Survey, 28 Energy Policy 389-401 (2002)","cited_authors":"Lorna A. Greening et al.","cited_year":"2002","cited_title":"Energy Efficiency and Consumption—The Rebound Effect—A Survey","cited_venue":"Energy Policy","cited_doi":"10.1016/s0301-4215(00)00021-5","cited_url":"www.sciencedirect.com/science/article/pii/S0301421500000215","ref_kind":"journal_article","section":"fn 130","page":null,"context_sentence":"DOE also examined a 2012 ACEEE paper \\128\\ and a 2013 paper by Thomas and Azevedo.\\129\\ Both of these publications examined the same studies that were reviewed by Sorrell, as well as Greening et al.,\\130\\ and identified methodological problems with some of the studies.","paper_id":1486,"paper_title":"Energy efficiency and consumption — the rebound effect — a survey","paper_year":2000,"paper_doi":"10.1016/s0301-4215(00)00021-5"},{"citation_id":457583,"raw_reference":"Lekov A., V. Franco, G. Wong-Parodi, J. McMahon, P. Chan, Economics of residential gas furnaces and water heaters in US new construction market, Energy Efficiency (September 2010) Volume 3, Issue 3, pp 203-222","cited_authors":"Lekov A.; Franco, V.; Wong-Parodi, G.; McMahon, J.; Chan, P.","cited_year":"2010","cited_title":"Economics of residential gas furnaces and water heaters in US new construction market","cited_venue":"Energy Efficiency","cited_doi":"10.1007/s12053-009-9061-y","cited_url":"link.springer.com/article/10.1007/s12053-009-9061-y","ref_kind":"journal_article","section":"fn 118","page":null,"context_sentence":"(i) New Construction or New Owner Installations It is common practice in new construction, when possible, to avoid vertical venting in order to limit roof penetrations and reduce potential liability issues (e.g., water leakage through new roof penetrations).\\118\\ Condensing furnaces have the flexibility of being vented either horizontally or vertically.","paper_id":30755,"paper_title":"Economics of residential gas furnaces and water heaters in US new construction market","paper_year":2009,"paper_doi":"10.1007/s12053-009-9061-y"},{"citation_id":457584,"raw_reference":"Ward, D.O., Clark, C.D., Jensen, K.L., Yen, S.T., & Russell, C.S. (2011): Factors influencing willingness-to pay for the ENERGY STAR label, Energy Policy, 39 (3), 1450-1458.","cited_authors":"Ward, D.O.; Clark, C.D.; Jensen, K.L.; Yen, S.T.; Russell, C.S.","cited_year":"2011","cited_title":"Factors influencing willingness-to pay for the ENERGY STAR label","cited_venue":"Energy Policy","cited_doi":"10.1016/j.enpol.2010.12.017","cited_url":"www.sciencedirect.com/science/article/abs/pii/S0301421510009171","ref_kind":"journal_article","section":"fn 165","page":null,"context_sentence":"There are consumers who are willing to pay a premium for more energy-efficient products because they are environmentally conscious.\\165\\ There are also several behavioral factors that can influence the purchasing decisions of complicated multi-attribute products, such as furnaces.","paper_id":5708,"paper_title":"Factors influencing willingness-to-pay for the ENERGY STAR ® label","paper_year":2011,"paper_doi":"10.1016/j.enpol.2010.12.017"},{"citation_id":457585,"raw_reference":"Thaler, R.H., and Bernartzi, S. (2004). Save More Tomorrow: Using Behavioral Economics in Increase Employee Savings, Journal of Political Economy 112(1), S164-S187.","cited_authors":"Thaler, R.H.; Bernartzi, S.","cited_year":"2004","cited_title":"Save More Tomorrow: Using Behavioral Economics in Increase Employee Savings","cited_venue":"Journal of Political Economy","cited_doi":"10.1086/380085","cited_url":null,"ref_kind":"journal_article","section":"fn 167","page":null,"context_sentence":"Consumers or decision makers also face a variety of other behavioral phenomena including loss aversion, sensitivity to information salience, and other forms of bounded rationality.\\167\\ Thaler, who won the Nobel Prize in Economics in 2017 for his contributions to behavioral economics, and Sunstein point out that these behavioral factors are strongest when the decisions are complex and infrequent, when feedback on the decision is muted and slow, and when there is a high degree of information asymmetry.\\168\\ These characteristics describe almost all purchasing situations of appliances and equipment, including furnaces.","paper_id":586,"paper_title":"Save More Tomorrow™: Using Behavioral Economics to Increase Employee Saving","paper_year":2004,"paper_doi":"10.1086/380085"},{"citation_id":457586,"raw_reference":"Thaler, R.H., and Sunstein, C.R. (2008). Nudge: Improving Decisions on Health, Wealth, and Happiness. New Haven, CT: Yale University Press.","cited_authors":"Thaler, R.H.; Sunstein, C.R.","cited_year":"2008","cited_title":"Nudge: Improving Decisions on Health, Wealth, and Happiness","cited_venue":"Yale University Press","cited_doi":null,"cited_url":null,"ref_kind":"book","section":"fn 168","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":457587,"raw_reference":"Fujita, S., Commercial, Industrial, and Institutional Discount Rate Estimation for Efficiency Standards Analysis: Sector-Level Data 1998-2018","cited_authors":"Fujita, S.","cited_year":null,"cited_title":"Commercial, Industrial, and Institutional Discount Rate Estimation for Efficiency Standards Analysis: Sector-Level Data 1998-2018","cited_venue":"Lawrence Berkeley National Laboratory","cited_doi":"10.2172/1591858","cited_url":"ees.lbl.gov/publications/commercial-industrial-and","ref_kind":"research_report","section":"fn 154","page":null,"context_sentence":"DOE's commercial discount rate approach is based on the methodology described in a LBNL report, and the distribution varies by business activity.\\154\\ The average rate for NWGFs used in commercial applications in this NOPR analysis, across all business activity, is 6.7 percent. --------------------------------------------------------------------------- ---------------------------------------------------------------------------","paper_id":28738,"paper_title":"Commercial, Industrial, and Institutional Discount Rate Estimation for Efficiency Standards Analysis: Sector-Level Data 1998 – 2018","paper_year":2020,"paper_doi":"10.2172/1591858"},{"citation_id":457588,"raw_reference":"Oak Ridge National Laboratory, Condensing Furnace Venting Part 2: Evaluation of Same-Chimney Vent Systems for Condensing Furnaces and Natural Draft Water Heaters (February 2015)","cited_authors":"Oak Ridge National Laboratory","cited_year":"2015","cited_title":"Condensing Furnace Venting Part 2: Evaluation of Same-Chimney Vent Systems for Condensing Furnaces and Natural Draft Water Heaters","cited_venue":"Oak Ridge National Laboratory","cited_doi":null,"cited_url":"web.ornl.gov/sci/buildings/docs/Condensing-Furnace-Venting-Part2-Report.pdf","ref_kind":"research_report","section":"fn 100","page":null,"context_sentence":null,"paper_id":7205,"paper_title":"Condensing Furnace Venting Part 2: Evaluation of Same-Chimney Vent Systems for Condensing Furnaces and Natural Draft Water Heaters","paper_year":2015,"paper_doi":"10.2172/1187915"},{"citation_id":459294,"raw_reference":"Interagency Working Group on Social Cost of Greenhouse Gases, Technical Support Document: Social Cost of Carbon, Methane, and Nitrous Oxide. Interim Estimates Under Executive Order 13990, Washington, DC (February 2021)","cited_authors":"Interagency Working Group on Social Cost of Greenhouse Gases","cited_year":"2021","cited_title":"Technical Support Document: Social Cost of Carbon, Methane, and Nitrous Oxide. Interim Estimates Under Executive Order 13990","cited_venue":"Washington, DC","cited_doi":null,"cited_url":"www.whitehouse.gov/wp-content/uploads/2021/02/TechnicalSupportDocument_SocialCostofCarbonMethaneNitrousOxide.pdf","ref_kind":"government_report","section":"fn 8","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":459295,"raw_reference":"Richard Campbell, National Fire Protection Association Fire Analysis and Research Division, Home Heating Fires Supporting Tables (January 2021) p. 7","cited_authors":"Richard Campbell","cited_year":"2021","cited_title":"Home Heating Fires Supporting Tables","cited_venue":"National Fire Protection Association","cited_doi":null,"cited_url":"www.nfpa.org/news-and-research/fire-statistics-and-reports/fire-statistics/fire-causes/appliances-and-equipment/heating-equipment","ref_kind":"research_report","section":"fn 42","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":459296,"raw_reference":"FEMA, Heating Fires in Residential Buildings (2010-2012), Topical Fire Report Series (December 2014) p. 7","cited_authors":"FEMA","cited_year":"2014","cited_title":"Heating Fires in Residential Buildings (2010-2012)","cited_venue":"Topical Fire Report Series, Federal Emergency Management Agency","cited_doi":null,"cited_url":"www.usfa.fema.gov/downloads/pdf/statistics/v15i7.pdf","ref_kind":"government_report","section":"fn 44","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":459297,"raw_reference":"AGA presented information ... HTR Engineering furnace sizing study","cited_authors":"HTR Engineering","cited_year":"2016","cited_title":"HTR Furnace Sizing Study","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"IV.F.1 Furnace Sizing Requirements Based on ACCA Manual J and Manual S","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":461349,"raw_reference":"Energy Conservation Standards Rulemaking Peer Review Report (2007), available at www.energy.gov/eere/buildings/downloads/energy-conservation-standards-rulemaking-peer-review-report-0","cited_authors":"U.S. Department of Energy","cited_year":"2007","cited_title":"Energy Conservation Standards Rulemaking Peer Review Report","cited_venue":"U.S. Department of Energy","cited_doi":null,"cited_url":"www.energy.gov/eere/buildings/downloads/energy-conservation-standards-rulemaking-peer-review-report-0","ref_kind":"research_report","section":"fn 280","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":461350,"raw_reference":"Review of Methods for Setting Building and Equipment Performance Standards, National Academies of Sciences, Engineering, and Medicine, www.nationalacademies.org/our-work/review-of-methods-for-setting-building-and-equipment-performance-standards","cited_authors":"National Academies of Sciences, Engineering, and Medicine","cited_year":null,"cited_title":"Review of Methods for Setting Building and Equipment Performance Standards","cited_venue":"National Academies of Sciences, Engineering, and Medicine","cited_doi":null,"cited_url":"www.nationalacademies.org/our-work/review-of-methods-for-setting-building-and-equipment-performance-standards","ref_kind":"research_report","section":"fn 281","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null}]}