Ultraviolet Disinfection Guidance Manual. Part 5 of 6.
Other documents for the same rulemaking (all, by stage)
References
Bolton, J.R., M.I. Stefan, R.S. Cushing, and E. Mackey. 2001. Importance of water absorbance/transmittance on the efficiency of ultraviolet disinfection reactors. Proceedings of the IUVA 1st International Congress, June 14-16, Washington, D.C.
Christensen, J. and K. Linden. 2001. Ultraviolet disinfection of unfiltered drinking water: particle impacts. Proceedings of the IUVA 1st International Congress, June 14-16,
Washington, D.C. Christensen, J. and K. Linden. 2002. New findings regarding the impacts of suspended particles on UV disinfection of drinking water. Proceedings of the AWWA Annual Conference, June 16-20, New Orleans, L.A.
Cushing, R.S., E.D. Mackey, J.R. Bolton, and M.I. Stefan. 2001. Impact of common water treatment chemicals on UV disinfection. Proceedings of the AWWA Annual Conference and Exposition, June 17-21, Washington DC.
Malley, J.P. 2002. Historical perspective of UV use. Presented at the AWWA Water Quality Technology Conference, November 10-14, Seattle, W.A.
Oppenheimer J., T. Gillogly, G. Stolarik, and R. Ward. 2002. Comparing the efficiency of low and medium pressure UV light for inactivating Giardia muris and Cryptosporidium parvum in waters with low and high levels of turbidity. Proceedings of the AWWA Annual Conference, June 16-20, New Orleans, L.A.
Parker, J.A. and J.L. Darby. 1995. Particle-associated coliform in secondary effluents: shielding from ultraviolet light disinfection. Water Environment Research 67:1065-1075.
Passantino, L. and J.P. Malley. 2001. Impacts of turbidity and algal content of unfiltered drinking water supplies on the ultraviolet disinfection process. Proceedings of the
Womba P., W. Bellamy, J. Malley, and C. Douglas. 2002. UV disinfection and disinfection byproduct characteristics of an unfiltered water supply, Project 2747. Denver, C.O.: AwwaRF periodic report.
Appendix H. Issues for Ground Water Systems fouling is greater with medium pressure (MP) reactors than low pressure (LP) and low pressure high output (LPHO) reactors because MP lamps operate at higher temperatures (section 2.4.2). Mechanical wipers are often effective at removing fouling on the lamp sleeves. In situations where the ground water has detectable levels of iron and manganese, chlorination prior to the UV reactors may cause increased fouling or staining, necessitating chemical cleaning (Malley et al. 2001). A complete discussion of the relevant water quality parameters and the determination of their design values is presented in section 3.1.3.1. With ground water systems, it is common for one or more wells to be taken out of service for an extended period due to fluctuations in water demand, ground water quality, operational problems, or other planned and unplanned circumstances.
Toivanen (2000) reported that the lamp sleeves and internal surfaces of the UV reactors became fouled when the UV reactors were out-of-service and full of water. The amount of time it takes to foul the UV reactor while off-line is site-specific and depends on the water quality. At a minimum, it is recommended that the reactors be drained if the UV reactor is off-line for more than one week; however, the appropriate period for this could be shorter or longer depending on the water quality. If the UV reactor will be off-line for an extended period of time (longer than 30 days), it is recommended
First, off-specification can occur when the flow, UVT, or UV intensity is outside of the validated conditions. Second, UV lamps can lose arc if a voltage fluctuation, power quality anomaly, or a power interruption occurs. LP lamps generally can return to full operating status within 15 seconds after power is restored. However, LPHO and MP UV lamps exhibit restart times between 4 and 10 minutes if power is interrupted (Cotton et al. 2002). During these restart times, the water being distributed is inadequately disinfected and is considered off-specification. H.3.1 Power Quality Assessment A power quality assessment at each well site should be performed to determine if power quality might cause off-specification operation. In addition, the reliability of commercial power at remote sites may be less than that of more populated areas. Backup power or an uninterruptible power supply (UPS) may be needed, depending on the findings of the power
Cotton, C.A., R.S. Cushing, and D.M. Owen. 2002. The impact of the draft UV disinfection requirements on UV facility design and operation. Proceedings of the AWWA Annual
Conference, June 16-20, New Orleans, LA. Dinkloh, L. 2001. Wedeco-Ideal Horizons. Telephone conversations and email correspondence by Ben Hauck, Malcolm Pirnie Inc., regarding UV reactors. April 25 and August 10.
Malley, J.P., B.A. Petri, G.L. Hunter, D. Moran, M. Nadeau, and J. Leach. 2001. Full-scale implementation of UV in groundwater disinfection systems. Denver, CO: AwwaRF Final Report.
Miller, A. 2001. Trojan Technologies. Telephone conversation by Ben Hauck, Malcolm Pirnie Inc., regarding UV reactors. August 10.
Toivanen, E. 2000. Experiences with UV disinfection at Helsinki water. IUVA News 2, no.6: 4-8.
UV disinfection is applicable to small systems and may be attractive for the following reasons: It is a relatively low cost technology for the inactivation of Cryptosporidium (Cotton et al. 2001). Chemical use is little to none. Operation is relatively simple and maintenance is low. Space needs are small. Two types of UV reactors can potentially be used by small systems, conventional and point-of-entry (POE) devices. Conventional UV reactors are manufactured for a wide range of flows (e.g., from 20 gallons per minute (gpm) up to 40 mgd) and are described in section 2.4.
Cotton, C.A., D.M. Owen, G.C. Cline, and T.P. Brodeur. 2001. UV disinfection costs for inactivating Cryptosporidium. Journal of the American Water Works Association 93, no. 2: 67-74.
Lin, L.-S., C.T. Johnston, and E.R. Blatchley. 1999a. Inorganic fouling at Quartz: Water interfaces in ultraviolet photoreactors – I Chemical characterization. Wat. Res. 33, no 15: 3321-3329.
Lin, L.-S., C.T. Johnston, and E.R. Blatchley. 1999b. Inorganic fouling at Quartz: Water interfaces in ultraviolet photoreactors – II Temporal and spatial distribution. Wat. Res. 33, no 15: 3330-3338.
Mackey, E.D., R.S. Cushing, and G.F. Crozes. 2001. Practical aspects of UV disinfection.
Mackey, E.D. and R.S. Cushing. Publication anticipated in 2003. Bridging pilot-scale testing to full-scale design of UV disinfection systems. Denver, CO: AWWA Research Foundation and AWWA.
Phillips, R. 1983. Sources and application of ultraviolet radiation. Academic Press: New York.
UV Disinfection Guidance Manual Proposal Draft J-10 June 2003