Ex. #136: Occupational Safety and Health Administration. (2009). Controlling silica exposures in construction (OSHA 3362-05 2009).
Other documents for the same rulemaking (all, by stage)
References: 208 extracted, 0 linked to papers
ACGIH. 2007. Industrial Ventilation, A Manual of Recommended Practice, 26th Edition. American Conference of Governmental Industrial Hygienists,
Cincinnati, OH. ACGIH. 2008. Threshold limit values for chemical substances and physical agents and biological exposure indices. American Conference of Governmental Industrial Hygienists, Cincinnati, OH.
Croteau, G.A. 2000. The effect of local exhaust ventilation controls on dust exposures during masonry activities. MS Thesis. University of Washington. June, 2000.
Seixas, N.S. 2002. The effect of local exhaust ventilation controls on dust exposures during concrete cutting and grinding activities. Am Ind Hygiene
Assn J. 63:458-467. July/August. ERG. 2000. Site visit report - Masonry Training
VA. September, 2000. Heitbrink, W.A. and Watkins, D.S. 2001. The effect of exhaust flow rate upon the respirable dust emissions for tuckpointing operations. In: In-Depth Study Report: Control Technology for Crystalline Silica Exposures in Construction. U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health. ECTB No. 247-18.
Heitbrink, W. and Collingwood, S. 2005. Protecting Tuckpointing Workers from Silica Dust: Draft Recommendations for Ventilated Grinder. The Center to Protect Workers’ Rights (CPWR). www.cpwr.com
Lofgren, D.J. 1993. Silica exposure for concrete workers and masons. Appl Occup Environ Hygiene 8(10):832-836. October, 1993.
NIOSH. 1996. Preventing Silicosis and Deaths in Construction Workers. Publication No. 96-112. National Institute for Occupational Safety and Health.
EXPOSURES CONSTRUCTION NIOSH. 1999a. Control technology and exposure assessment for occupational exposure to crystalline silica: Case 16 - Wet Cutting of Concrete Masonry
October, 1999. Some employers use a hose connected to an external water source to provide a continuous flow of fresh water in place of recirculated water. This eliminates the need for pumps and filters, but requires substantially more water and produces more runoff.
NIOSH. 1999b. Control technology and exposure assessment for occupational exposure to crystalline silica: Case 18 - Cutting Brick and Concrete Masonry Units. ECTB 233-118c. National Institute for Occupational Safety and Health, Cincinnati, OH.
November, 1999. NIOSH. 2002. Pocket guide to chemical hazards. Pub.
No. 2002-140. National Institute for Occupational Safety and Health, Cincinnati, OH. June, 2002.
OSHA. 1996. Ground-fault protection on construction sites. Occupational Safety and Health Administration, Office of Training and Education. May, 1996.
OSHA Case Files (Special Emphasis Program Inspection Reports from 1996-1998).
Shields, C. 2000. Database: Silica dust exposures associated with construction activities (version date: September 14, 2000). Occupational Safety and Health Administration, North Aurora Office, IL. Technical Notes Laboratories have not used particle counting for crystalline silica analysis for many years. Exposure data is now reported gravimetrically. However,
ACGIH. 2001. Industrial Ventilation, A Manual of Recommended Practice, 24th Edition. American Conference of Governmental Industrial
Hygienists, Cincinnati, OH. ACGIH. 2008. Threshold limit values for chemical substances and physical agents and biological exposure indices. American Conference of Governmental Industrial Hygienists, Cincinnati, OH.
Seixas, N.S. 2002. The effect of local exhaust ventilation controls on dust exposures during concrete cutting and grinding activities. Am Ind Hygiene Assn J 63:458-467. July/August, 2002.
CONTROLLING SILICA Diamond Products. 2001. SpeediCut cut-off saws. http://diamondproducts.com. Accessed September 8, 2008.
Heitbrink, W.A. and Watkins, D.S. 2001. The effect of exhaust flow rate upon the respirable dust emissions for tuckpointing operations. In: InDepth Study Report: Control Technology for Crystalline Silica Exposures in Construction. U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health. ECTB No. 247-18.
NIOSH. 1995. Environmental surveillance report: Concrete Coring, Inc., Enon, OH. U.S. Department of Health and Human Services, Public Health
Studies, Morgantown, WV. NIOSH. 1996. Alert: request for assistance in preventing silicosis and deaths in construction workers. DHHS (NIOSH) Publication No. 96-112. U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control and
NIOSH. 1999a. Control technology and exposure assessment for occupational exposure to crystalline silica: Case 17 - dry cutting of concrete masonry units. U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, Division of Physical Sciences and Engineering,
Cincinnati, OH. ECTB 233-117c. NIOSH. 1999b. Control technology and exposure assessment for occupational exposure to crystalline silica: Case 18 - cutting brick and concrete masonry units. U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, Division of Physical Sciences and Engineering,
Cincinnati, OH. ECTB 233-118c. NIOSH. 1999c. Control technology and exposure assessment for occupational exposure to crys-
OH. ECTB 233-121c. NIOSH. 2002. Pocket guide to chemical hazards. Pub. No. 2002-140. National Institute for Occupational Safety and Health, Cincinnati, OH.
June, 2002. OSHA. 1996. Ground-fault protection on construction sites. Occupational Safety and Health
May, 1996. OSHA Case Files (Special Emphasis Program Inspection Reports from 1996-1998).
Partner Industrial Products. 2001. The Partner wet cutting system. http://www.partnerusa.com. Accessed September 8, 2008.
Shields, C. 2000. Database: Silica dust exposures associated with construction activities (version date: September 14, 2000). Occupational Safety and Health Administration, North Aurora Office,
Stihl. 2001. Cutquick cut-off machine accessories. http://www.stihlusa.com. Accessed September 8, 2008.
Thorpe, A., Ritchie, A.S., Gibson, M.J. and Brown, R.C. 1999. Measurements of the effectiveness of dust control on cut-off saws used in the construction industry. Annals of Occup Hygiene 43 (7) 1443-1456. July, 1999.
Trakumas, S., Willeke, K., Reponen, T., Grinshpun, S.A. and Freidman, W. 2001. Comparison of filter bag, cyclonic, and wet dust collection methods in vacuum cleaners. Am Ind Hygiene Assn J 62:573583.
USF Surface Preparation Group. 2000b. Sawtec
JS-90. www.surfacepreparation.com Accessed September 8, 2008.
USF Surface Preparation Group. 2002. Personal communication between USF and Laura Lewis of
ERG, Inc. January 28, 2002. Technical Notes Laboratories have not used particle counting for crystalline silica analysis for many years. Exposure data is now reported gravimetrically. However,
OSHA’s construction PEL for crystalline silica, established in 1971, is still listed as a particle-count value. (See Appendix E to OSHA’s National Emphasis Program for Crystalline Silica, CPL 03-00-007, for a detailed discussion of the conversion factor used to transform gravimetric measurements to particlecount values). In this guidance, OSHA is using 0.1 mg/m3 of respirable quartz as an 8-hour timeweighted average as a benchmark to describe the effectiveness of control measures. The benchmark is approximately equivalent to the general industry silica PEL. Other organizations suggest lower levels. For example, the National Institute for Occupational Safety and Health (NIOSH) recommends that respirable crystalline silica exposures be limited to 0.05 mg/m3 as a 10-hour time-weighted average (NIOSH, 2002). The American Conference of Governmental Industrial Hygienists (ACGIH) recommends that respirable crystalline silica exposures be limited to 0.025 mg/m3 as an 8-hour time-weighted average (ACGIH, 2008). Some saws come set up for both water-feed and vacuum dust collection for better employee protection in all situations. For the system tested by Croteau et al. (2002), an airflow of 90 cubic feet per minute (CFM) through the vacuum controlled respirable dust better than 70 CFM.
ACGIH (2001) recommends a still higher airflow of 25 CFM per inch of blade diameter (equivalent to 236 CFM for the saw tested). Low airflow can cause ducts to clog. For abrasive wheel saws with vacuum dust collection, ACGIH recommends a minimum airflow velocity of 4,000 feet per
Zalk, D. 2000. Exposure assessment strategy for the reduction of airborne silica during jackhammering activities. Presentation. American Industrial Hygiene Conference and Exposition,
ACGIH. 2001. Industrial Ventilation, A Manual of Recommended Practice, 24th Edition. American Conference of Governmental Industrial Hygienists,
Akbar-Khanzadeh, F. and Brillhart, R.L. 2002. Respirable crystalline silica dust exposure during concrete finishing (grinding) using handheld grinders in the construction industry. Ann Occup Hygiene 46(3):341-346.
Seixas, N.S. 2002. The effect of local exhaust venti- Occupational Safety and Health Administration lation controls on dust exposures during concrete cutting and grinding activities. Am Ind Hygiene
OH. February, 2000. Echt, A. and Sieber, W.K. 2002. Control of silica exposure from hand tools in construction: Grinding concrete. Appl Occup Environ Hygiene 17(7):457461. July, 2002.
NIOSH. 2000b. Control technology and exposure assessment for occupational exposure to crystalline silica: Case 25 – Concrete pipe manufacturing (ECTB 233-125c). National Institute for Occupational Safety and Health, Cincinnati, OH. March, 2000.
ERG. 2002. Site visit report: Precast concrete product manufacturer facility B. Eastern Research
Group, Inc. September 26, 2002. Flanagan, M.E., Seixas, N., Majar, M., Camp, J. and
Morgan, M. 2003. Silica dust exposures during selected construction activities. Am Ind Hygiene