NAP 2018 Monitoring and Sampling Approaches to Assess Underground Coal Mine Dust Exposures
Other documents for the same rulemaking (all, by stage)
References
Tomb, T. F., H. N. Treaftis, R. L. Mundell, and P. S. Parobeck. 1973. Comparison of Respirable Dust Concentrations Measured with MRE and Modified Personal Gravimetric Sampling Equipment. Report of Investigations 7772. U.S. Department of Interior, Bureau of Mines, Washington, DC.
Tuchman, D. P., J. C. Volkwein, and R. P. Vinson. 2008. Implementing infrared determination of quartz particulates on novel filters for a prototype dust monitor. Journal of Environmental Monitoring 10(5):671-678.
NIOSH, 2008; Suarthana et al., 2011; Vallyathan et al., 2011). However, recent and unexpected observations of many new and severe cases of coal mine dust lung disease suggest the importance of other characteristics of RCMD particles, which had not been monitored widely in the past. In essence, those recent observations have raised a question about whether the important aspects of exposure are being monitored.
CPDM and use its data more willingly if they perceive the monitor is helping to save their lives and the lives of their co-workers (Lindell, 1994). How education and training are conducted is also important. Adults learn best when education is hands-on, interactive, based on using newly acquired knowledge to solve problems, and preferably in small groups (OSHA, 2010, 2015; ILO, 2012). Too often, safety and health instruction is delivered through lectures, videos, and slide presentations without accounting for how adults learn best. As one of the objectives of the program is providing exposure information to the miner wearing the CPDM, that individual miner may be able to move to a less dusty location or otherwise adjust work practices. However, such an action only protects that one miner. CPDM readings could be used to identify the areas and operations where RCMD concentrations are highest, for permanently reducing those concentrations through engineering and work practice controls. Proper education empowers miners to take action, not just for themselves, but also for their fellow miners (Weinstock and Slatin, 2012).
Additionally, data related to environmental and operational conditions during RCMD sampling and other periods may be available. These may include measurements related to ventilation (for example, velocity at the mining face or in other locations, curtain positioning), dust control (for example, spray volumes and pressures, loading rate of dust collectors), and mining conditions (for example, total mining height, coal seam thickness, roof rock characteristics, production or advance rate, bit replacement rate); and, again, these data may be collected on range of time bases (that is, from continuously to intermittently) and in various locations. Especially important for continuous measurements, data transmission in coal mines has been a topic of much research, including for personnel tracking and communications and for atmospheric gas monitoring applications (for example, see Dubaniewicz and Chilton, 1995; Novak et al., 2009; Griffin et al., 2011; Sunderman and Waynert, 2012; Damiano et al., 2014; Zhang, 2014; Rowland et al., 2018)—and an optimal RCMD sampling and monitoring program would take advantage of existing data transmission capabilities or develop further capabilities. For RCMD metrics, data availability is generally related to the sample analysis method. Where continuous measurements are possible, and the user has immediate access to the data, relatively quick, albeit reactive, decision-making is supported. For example, a miner wearing a
OPTIMAL MONITORING AND SAMPLING STRATEGIES The previous discussion envisioned an ideal monitoring and sampling program that would be implemented with few limitations. However, from a real-world perspective, the objectives of an ideal program cannot be achieved fully because of a variety of real-world constraints. This section considers optimal approaches for implementing aspects of an ideal program in the context of practical constraints. A mathematical approach to optimization could involve the use of techniques (such as linear, dynamic, nonlinear, or goal programming) to develop an objective function that is to be maximized or minimized. After the constraints on the function are specified, a mathematical region is described, where maximum or minimum values for the function can be determined, considering the pertinent variables and parameters (Taha, 2007). In the case of optimizing monitoring and sampling strategies mathematically, the objective would be to elucidate the most effective real-world strategy for quantifying the critical RCMD exposures causing lung diseases. However, the substantial complexities and uncertainties associated with performing a mathematical optimization in this context would not likely allow for meaningful solutions.
Maguire (2006) discusses risk-based decision making for achievement of dust exposures as low as reasonably practicable in light of technical and economic constraints.
Agioutantis, Z., K. Luxbacher, M. Karmis, and S. Schafrik. 2014. Development of an atmospheric datamanagement system for underground coal mines. Journal of the Southern African Institute of Mining and Metallurgy 114(12):1059-1063.
Ainsworth, S. M. 2013. Infrared analysis of respirable coal mine dust for quartz: Thirty five years. In Silica and Associated Respirable Mineral Particles, 45T M. Harper and L. Taekhee, eds. STP1565.
Almberg K. S., R. A. Cohen, D. J. Blackley, A. S. Laney, E. Storey, and C. N. Halldin. 2017. Linking Compensation and Health Surveillance Data Sets to Improve Knowledge of US Coal Miners’ Health. Journal of Occupational Medicine 59(10):930-934. Copyright National Academy of Sciences. All rights reserved. Monitoring and Sampling Approaches to Assess Underground Coal Mine Dust Exposures Monitoring and Sampling Approaches to Assess Underground Coal Mine Dust Exposures
Araujo, J. A., B. Barajas, M. Kleinman, X. Wang, B. J. Bennett, K. W. Gong, M. Navab, J. Harkema, C. Sioutas, A. J. Lusis, and A. E. Nel. 2008. Ambient particulate pollutants in the ultrafine range promote early atherosclerosis and systemic oxidative stress. Circulation Research 102:589-596.
ASTM D7439-14. 2014. Standard Test Method for Determination of Elements in Airborne Particulate Matter by Inductively Coupled Plasma–Mass Spectrometry. West Conshohocken, PA. ASTM International.
Barrett, C., S. Gaillard, and E. Sarver. 2017. Demonstration of continuous monitors for tracking DPM trends over prolonged periods in an underground mine. Proceedings of the 16th North American Mine Ventilation Symposium, June 17-22, 2017, Golden, CO. Littleton, CO: Society for Mining, Metallurgy, and Exploration.
Bhattacharya, S., S. Sridevi, and R. Pitchiah. 2012. Indoor air quality monitoring using wireless sensor network. In Sensing Technology (ICST), pp. 422-427.
Birch, M. E. 2003. Elemental Carbon (Diesel Particulate). Method 5040. NIOSH Manual of Analytical Methods (NMAM), 4th Ed. [online]. Available at https://www.cdc.gov/niosh/docs/2003-154/pdfs/50 40f3.pdf (accessed May 25, 2018).
Birch, M. E., and J. D. Noll. 2004. Submicrometer elemental carbon as a selective measure of diesel particulate matter in coal mines. Journal of Environmental Monitoring 6:799-806.
Blackley, D. J., J. Crum, C. Halldin, E. Storey, and A. Laney. 2016. Resurgence of progressive massive fibrosis in coal miners – Eastern Kentucky, 2016. Morbidity and Mortality Weekly Report 65(49):1385-1389. Available at https://www.cdc.gov/mmwr/volumes/65/wr/pdfs/mm6549.pdf (accessed October 23, 2017).
Brady, D., M. Watkinson, and P. Harrison. 2015. Best Practice Review of Atmospheric Monitoring Practices for Fire and Explosion Prevention Using Tube Bundle Systems for the National Institute for Occupational Safety and Health (NIOSH), under Contract No. 200-2013-56949.
Buiarelli, F., P. Di Filippo, D. Pomata, and M. Bartocci. 2017. A liquid chromatography tandem mass spectrometry method for simultaneous analysis of 46 atmospheric particulate-phase persistent organic pollutants and comparison with gas chromatography/mass spectrometry. International Journal of Environmental Analytical Chemistry 97(9):797-818.
Burkart, J., G. Steiner, G. Reischl, H. Moshammer, M. Neuberger, and R. Hitzenberger. 2010. Characterizing the performance of two optical particle counters (Grimm OPC1.108 and OPC1.109) under urban aerosol conditions. Journal of Aerosol Science 41(10):953-962.
Castranova, V., N. S. Dalal, and V. Vallyathan. 1995. Role of surface free radicals in the pathogenicity of silica. In Silica and Silica-induced Lung Diseases, V. Castranova, V. Vallyathan, and W. E. Wallace, eds. Boca Raton, FL: CRC Press, pp. 91-105.
Cauda, E., A. Miller, and P. Drake. 2015. A new end-of-shift. Monitoring approach for respirable crystalline silica in coal mine dust. In 15th North American Mine Ventilation Symposium, E. Jong, E. Sarver, S.
Cauda, E., A. Miller, and P. Drake. 2016. Promoting early exposure monitoring for respirable crystalline silica: Taking the laboratory to the mine site. Journal of Occupational and Environmental Hygiene 13(6):D39-D45.
Chalmers, D., and C. Harb. 2017. Pilot study in real time respirable silica measurement. In Proceedings of the 16th North American Mine Ventilation Symposium, June 17-22, 2017, Golden, CO, J.F. Brune, ed. Littleton, CO: Society for Mining, Metallurgy, and Exploration, pp. 15-9–15-17.
Chow, J. C., J. G. Watson, D. Crow, D. H. Lowenthal, and T. Merrifield. 2001. Comparison of IMPROVE and NIOSH carbon measurements. Aerosol Science and Technology 34(1):23-34.
Chow, J. C., J. G. Watson, L. W. Chen, M. C. Chang, N. F. Robinson, D. Trimble, and S. Kohl. 2007. The
Hannigan. 2017. Low-Cost Air Quality Monitoring Tools: From Research to Practice (A Workshop Summary). Sensors 17(11): 2478.
Cohen, A., and M. J. Colligan. 1998. Assessing Occupational Safety and Health Training: A Literature Review, DHHS (NIOSH) Publication No. 98-145 [online]. Available at https://www.cdc.gov/niosh/docs /98-145/pdfs/98-145.pdf (accessed April 26, 2018).
Green. 2016. Lung pathology in U.S. coal workers with rapidly progressive pneumoconiosis implicates silica and silicates. American Journal of Respiratory and Critical Care Medicine 193(6):673-680. Copyright National Academy of Sciences. All rights reserved. Monitoring and Sampling Approaches to Assess Underground Coal Mine Dust Exposures Optimizing Monitoring and Sampling Strategies
Cook, D. J. and S. K. Das. 2007. How smart are our environments? An updated look at the state of the art. Pervasive and mobile computing 3(2):53-73.
Crilley, L. R., M. Shaw, R. Pound, L. J. Kramer, R. Price, S. Young, A. C. Lewis, and F. D. Pope. 2018. Evaluation of a low-cost optical particle counter (Alphasense OPC-N2) for ambient air monitoring. Atmospheric Measurement Techniques 11(2):709.
Damiano, N., G. Homce, and R. Jacksha. 2014. A review of underground coal mine emergency communications and tracking system installations. Coal Age magazine, pp. 34-35.
Delal, N. S., M. M. Suryan, V. Vallyathan, F. H. Green, B. Jafari, and R. Wheeler. 1989. Detection of reactive free radicals in fresh coal mine dust and their implication for pulmonary injury. Annals of Occupational Hygiene 33(1):79-84.
Dubaniewicz, T. H., and J. E. Chilton. 1995. Fiber optic powered remote gas monitor. In Optical Engineering Midwest ‘95 2622: 285-292.
FLIR. 2017. Airtec™ Diesel Particulate Monitor [online]. Available at http://www.flir.com/instruments/dis play/?id=57067 (accessed December 14, 2017).
Freedman, R. W., and A. G. Sharkey, Jr. 1972. Recent advances in the analysis of respirable coal dust for free silica, trace elements, and organic constituents. Annals of the New York Academy of Sciences 200(1):7-16.
Graber, J. M., G. Harris, K. S. Almberg , C. S. Rose, E. L. Petsonk, R. A. Cohen. 2017. Increasing Severity of Pneumoconiosis Among Younger Former US Coal Miners Working Exclusively Under Modern Dust-Control Regulations. Journal of Occupational Environmental Medicine 59(6):e105–e111.
Griffin, K. R., E. C. Jong, K. D. Luxbacher, and E. C. Westman. 2011. A review of atmospheric monitoring systems in underground coal mines: implications for explosion prevention. In SME Annual Meeting and Exhibit and CMA 113th National Western Mining Conference 2011. 683-686. Society for Mining, Metallurgy, and Exploration.
Grimm, H., and D. J. Eatough. 2009. Aerosol measurement: The use of optical light scattering for the determination of particulate size distribution, and particulate mass, including the semi-volatile fraction. Journal of the Air & Waste Management Association 59(1):101-107.
Hall, E. E., R. P. Vinson, and J. C. Volkwein. 2006. Evaluation of SKC Inc. dust detective. In Proceedings of the 11th U.S./North American Mine Ventilation Symposium 2006, J. M. Mutmansky and R. V.
Harper, M., B. Pacolay, P. Hintz, D. L. Bartley, J. E. Slaven, and M. E. Andrew. 2007. Portable XRF analysis of occupational air filter samples from different workplaces using different samplers: final results, summary and conclusions. Journal of Environmental Monitoring 9(11):1263-1270.
Harper, M., K. Sarkisian, and M. Andrew. 2014. Assessment of respirable crystalline silica analysis using proficiency analytical testing results from 2003–2013. Journal of Occupational and Environmental Hygiene 45T46T1146T(10):D157-D163.
Harrison, J., P. Brower, M. Attfield, C. Doak, M. Keane, R. Grayson, and W. E. Wallace. 1997. Surface composition of respirable silica particles in a set of U.S. anthracite and bituminous coal mine dusts. Journal of Aerosol Science 28:689-696.
Hoffer, D. 2014. What does big data look like? Visualization is key for humans. Wired.com [online]. Available at https://www.wired.com/insights/2014/01/big-data-look-like-visualization-key-humans/ (accessed December 13, 2017).
Huggins, C. W., S. J. Johnson, J. M. Segreti, and J. G. Snyder. 1986. Comparison of the particle size distribution of alpha quartz found in respirable dust samples collected at underground and surface coal mines with four reference standards. In Electron Microscopy in Forensic, Occupational, and Environmental Health Sciences, S. Basu and J. R. Millette, eds. Boston, MA: Springer, pp. 187-202.
Hutchins, P. M. 2016. Real-time viable particle monitoring: Principles and benefits for in-process measurements. American Pharmaceutical Review December 1 [online]. Available at http://www.american pharmaceuticalreview.com/Featured-Articles/331674-Real-Time-Viable-Particle-Monitoring-Principles -and-Benefits-for-In-Process-Measurements/ (accessed December 12, 2017).
IARC (International Agency for Research on Cancer). 1997. Aramid Fibrils. IARC Monographs on Evaluation of Carcinogenic Risks to Humans Vol 68. Lyon, France: IARC Press [online]. Available at http://monographs.iarc.fr/ENG/Monographs/vol68/index.php (accessed October 23, 2017).
ILO (International Labour Organization). 2012. Encyclopedia of Occupational Health and Safety, Chapter 18, Education and Training [online]. Available at http://www.ilocis.org/documents/chpt18e.htm (accessed December 8, 2017). Copyright National Academy of Sciences. All rights reserved. Monitoring and Sampling Approaches to Assess Underground Coal Mine Dust Exposures Monitoring and Sampling Approaches to Assess Underground Coal Mine Dust Exposures
Kissell, F. N., and E. D. Thimons. 2001. Test report on the machine-mounted continuous respirable dust monitor. In Proceedings of the 7th International Mine Ventilation Congress, June 17-22, 2001,
Koehler, K. A., and T. M. Peters. 2015. New methods for personal exposure monitoring for airborne particles. Current Environmental Health Reports 2(4):399-411.