65 FR 42068 2000 Determination of Concentration of Respirable Coal Mine Dust - Proposed rule; Notice of hearings.
Other documents for the same rulemaking (all, by stage)
References
MSHA’s historical estimate of upper bound ..................................................................... 1981 measurement assurance estimate;† older technology, truncation of weights ........ 59 FR 8356; Kogut, September 6, 1994a ..
Parobeck, et al., 1981; Bartley, September 7, 1994.
Wagner, May 28, 1997 ...............................
Parobeck, et al., 1997 ................................
Kogut, et al., 1999 ...................................... 10.3 11.2 11.3
Kogut, et al., 1999 ...................................... 11.6 300 unexposed tamper-resistant capsules pre- and post-weighed in different labs;† no truncation. Inspector samples processed between late 1992 and mid 1995;† capsules pre- and post-weighed in different labs with truncation; estimate adjusted for differences between labs.
NMA data obtained from samples collected by Skyline Coal, Inc.† ................................ Value used in NIOSH ‘‘indirect approach’’ based on repeated measurements on same day and in same lab;† derived from Kogut. 1995 MSHA field study;† capsules pre-weighed, assembled, and post-weighed by
MSHA. 1996 measurement assurance estimate † ....................................................................... 75 unexposed capsules recalled from MSHA field offices † ............................................ 50 replicate weighings of 16 unexposed filter capsules † ................................................ 50 replicate weighings of 16 unexposed filter capsules † ................................................ 2,640 unexposed ‘‘quality control’’ capsules pre-weighed by MSHA, assembled by
MSA Mine Safety Appliances Co. In MSHA’s February 1994 notice, 1.438σe (identified as ‘‘variability associated with the VerDate 11<MAY>2000 00:57 Jul 07, 2000 pre- and post-weighing of the filter capsule’’) was presented as 0.14 mg/m3, or 7 percent of Jkt 190000
PO 00000 Frm 00047 Fmt 4701 Sfmt 4702 2.0 mg/m3, as described in Kogut (September 6, 1994a). It follows that the value of σe E:\FR\FM\07JYP2.SGM pfrm08 PsN: 07JYP2 42114 Federal Register / Vol. 65, No. 131 / Friday, July 7, 2000 / Proposed Rules implicitly assumed in MSHA’s February 1994 notice (obtained by dividing 0.14 by 1.438) was 0.0974 mg (97.4 µg). Seven percent of 2.0 mg/m3 had been used by
MSHA from the inception of its dust enforcement program to represent an upper bound on weighing imprecision in a dust concentration measurement. After publication of the February 1994 notice, several other candidate values for σe were placed into the public record. In 1981, based on data collected to implement a measurement assurance program in MSHA’s weighing laboratory, σe was estimated using a method developed by the NBS to be 0.0807 mg (80.7 µg) (Parobeck, et al., 1981). The published NBS estimate reflected weighing technology in place at the time the article was published (1981), as well as the practice (no longer in effect for MSHA inspector samples) of truncating both the pre- and postexposure weights down to an exact multiple of 0.1 mg. This estimate was used to calculate CVweight by Bartley (September, 1994). Some previous commenters misread or misunderstood the published NBS estimate. One of these previous commenters claimed that ‘‘the only published report of the weighing error in MSHA’s laboratory * * * was 0.16 mg of variation, which would convert to a concentration of 0.20 mg/m3 compared to the 0.14 mg/m3 * * * MSHA and NIOSH used.’’ This is incorrect, since the standard deviation of weight-gain errors (including the effect of truncation) is actually identified as 0.0807 mg in the Appendix to
Parobeck, et al., (1981). The 0.16-mg figure quoted by the commenter is presented in that paper as defining a 2-tailed 95-percent confidence limit, for use in establishing process control limits. It is derived by multiplying σe by 2.0. As explained above, the published value of σe = 0.0807 mg is multiplied by 1.438 m¥3 to propagate an
NBS estimate and the 97.4-µg value assumed in the February 1994 notice included the effects of truncating weight measurements to 0.1 mg. Truncation effects are also included in the 51.7-µg estimate. Some previous commenters expressed special concern over the accuracy of preexposure filter capsule weights as measured by Mine Safety Appliances Co. One commenter expressed ‘‘grave concern’’ with regard to the 12-µg systematic difference in weights found between Mine Safety Appliances Co. and MSHA weighings of the same unexposed capsules, as described in
MSHA’s 1994 analysis (Kogut, May 12, 1994). These concerns became moot, at least with respect to MSHA’s inspector sampling program, when MSHA began pre- and postweighing all inspector samples at MSHA’s laboratory. Furthermore, any potential bias resulting from differences in laboratory conditions on the days of pre- and postexposure weighings should now be eliminated by the use of control filter capsules. However, contrary to this commenter’s interpretation, the analysis submitted to the record in September 1994 resulted in a substantially lower estimate of σe than that assumed in the February 1994 notice—even after adjustment for the 12-µg systematic difference observed between weighing laboratories. The 51.7-µg estimate discussed above includes this adjustment.
MSHA and NIOSH also analyzed data submitted by the NMA in connection with these proceedings. An important result of that analysis, described in Appendix D, was an estimate of σe equal to 76 µg ± 15 µg.33 This estimate is not significantly different, statistically, from either the 97.4-µg value assumed in the February 1994 notice, the 80.7-µg NBS estimate, or the 51.7-µg value estimated for samples collected between late 1992 and mid-1995. Since the NMA data were obtained from samples collected by Skyline Coal, Inc. prior to 1995, the Secretaries believe these data confirm the 51.7-µg value of σe applicable to the Skyline samples. The estimate of σe obtained from the Skyline data is, however, significantly greater than the value estimated for weight-gain measurements under MSHA’s current inspection program. This is explained by the fact that when the Skyline samples were collected, all samples were weighed in different laboratories before and after 33 To construct a 90-percent confidence interval for σe, based on the Skyline data, the 15-µg ‘‘standard error of the estimate’’ must be multiplied by a confidence coefficient of 1.64. Jkt 190000
PO 00000 Frm 00048 Fmt 4701 Sfmt 4702 sampling, and the weights were truncated to 0.1 mg. before calculating the weight gain. Both truncation of weights and the practice of pre- and post-weighing samples in different laboratories were discontinued for inspector samples in mid-1995. Under