Technical Support Document for Sections 194.22 and 23: Review of WIPP Recertification Performance Assessment Computer Codes - CRA Code Review
Other documents for the same rulemaking (all, by stage)
References
WIPP PA (Performance Assessment). 2001. “Validation Document for PRELHS Version 2.24" Sandia National Laboratories. ERMS #518675.
WIPP PA (Performance Assessment). 2002. “Verification and Validation Plan, Validation Document and Criteria Forms for PRELHS, Version 2.30" Sandia National Laboratories.
ERMS #519722. EPA, 2003. “Review of WIPP Performance Assessment Computer Code Migration”, June 10, 2003, EPA Docket: A-98-49, II-B3-57. Environmental Protection Agency.
WIPP PA (Performance Assessment). 2003. “Addenda to Verification and Validation Plan/Validation Document for PREHLHS version 2.30" Sandia National Laboratories.
CCA. PRESECOTP2D 1.11ZO was validated in September 1995 on a DEC Alpha 2100 with OpenVMS 6.1 by regression testing to a validated primitive package
[3] that demonstrated that the results of two test cases (2 and 3) met the acceptance criteria defined in the RD/VVP for PRESECOTP2D 1.11ZO [4]. 5.32.1 Introduction In August 1996 PRESECOTP2D was revised to Version 1.20 and was validated on a DEC Alpha 2100 with OpenVMS 6.1 [5, 6]. Test Case 1 for the validation of PRESECOTP2D 1.20 was identical to test case for the validation of PRESECOTP2D 1.11ZO. The acceptance criteria for this test case was satisfied by showing that the output from PRESECOTP2D 1.20 was identical to the output of the PRESECOTP2D 1.11ZO validation tests. Test Cases 2 and 3 were modified to test code functionality that changes from version 1.11ZO to version 1.20. In these test cases, the acceptance criteria were satisfied by analysis of the output of PRESECOTP2D 2.20. In June 1997, PRESECOTP2D was revised to Version 1.22 and was validated on a DEC Alpha 2100 with OpenVMS 6.1 [1, 2]. The validation test included the three test cases defined for Version 1.20, and an additional Test Case 4. Test Case 4 was added to verify the variable time step functionality by showing the time increments produced by the code match those produced by the algorithm in the user’s manual [7]. Acceptance criteria for Test Cases 1-3 were satisfied by comparing output of PRESECOTP2D 1.22 to the output of PRESECOTP2D 1.20, while the acceptance criteria for Test Case 4 were satisfied by analysis of the output of PRESECOTP2D
WIPP PA (Performance Assessment). 1997. “Requirements Document & Verification and Validation Plan for PRESECOTP2D Version 1.22" Sandia National Laboratories. ERMS #245957.
WIPP PA (Performance Assessment). 1997. “Validation Document for PRESECOTP2D Version 1.22" Sandia National Laboratories. ERMS #245965. “Primitive Data Package” for PRESECOTP2D, Version 1.11ZO, Version date 8/16/93, Binder with the following information: Abstract User Manual, On-Line Help, Verification,
WIPP PA (Performance Assessment). 1995. “Requirements Document & Verification and Validation Plan for PRESECOTP2D Version 1.11ZO” Sandia National Laboratories.
ERMS #223324. WIPP PA (Performance Assessment). 1996. “Requirements Document & Verification and Validation Plan for PRESECOTP2D Version 1.20" Sandia National Laboratories. Sandia
WIPP Central Files ERMS #237295. WIPP PA (Performance Assessment). 1996. “Validation Document for PRESECOTP2D Version 1.20" Sandia National Laboratories. ERMS #240254. 5.33
WIPP PA (Performance Assessment). 1997. “User’s Manual for PRESECOTP2D Version 1.22" Sandia National Laboratories. Sandia Central Files ERMS #245963.
RELATE version 1.42ZO was validated in October 1995 on a DEC Alpha 2100 with OpenVMS 6.1 by demonstrating that the results of three test cases met the acceptance criteria defined in the
RD/VVP for RELATE 1.42ZO [1]. In March 1996, RELATE was revised to Version 1.43 and was validated on a DEC Alpha 2100 with OpenVMS 6.1. Test cases identical to the test cases for the validation of RELATE 1.42ZO were run. The acceptance criteria for these test cases were satisfied by showing that the output from RELATE 1.43 was identical to the output of the RELATE 1.42ZO validation tests.
RELATE 1.43 was used in the WIPP Compliance Certification Application (CCA). In order to test new operating systems that were added in 2002-03 (Section 1), regression test results from RELATE 1.43 run on the ES40 with OpenVMS 7.3-1 were compared to results from the validation tests of RELATE 1.43 run on a DEC Alpha 2100 with OpenVMS 6.1. In June 2003, the Agency completed a report documenting the Agency’s approval with respect to the migration and verification of RELATE 1.43 on those operating systems [3]. In January 2003, two new hardware systems were added to conduct performance assessments for the WIPP. A Compaq ES45, and a Compaq Alpha 8400 which are both running Open VMS 7.3-1[4,5]. The discussion below documents the test methodology, regression test results, and the Agency’s conclusions with respect to RELATE 1.43 on the new hardware systems. 5.33.2 Test Methodology The tests for this code comprised the three test cases described in the Requirements Document & Verification and Validation Plan for RELATE Version 1.42Z0 (RD/VVP) [1]. Regression test results from RELATE 1.43, run on the ES45 and 8400 with OpenVMS 7.3-1, were compared to results from the validation tests of RELATE 1.43, run on the ES40 with OpenVMS 7.3-1.
GROPECDB 2.10. GROPECDB has since been revised to Version 2.12. GROPECDB 2.12 was validated in June 1996 on a DEC Alpha 2100 with OpenVMS 6.1 [2]. GROPECDB 2.12 has also been validated on a Compaq ES45 and 8400 with OpenVMS 7.3-1 as part of the hardware regression test (see Section 5.10). For this regression test, GROPECDB 2.12 is used to convert the
WIPP PA (Performance Assessment). 1995. “Requirements Document & Verification and Validation Plan for RELATE Version 1.42ZO” Sandia National Laboratories. ERMS #224184.
WIPP PA (Performance Assessment) 1996. “Validation Document for GROPECDB Version 2.12" Sandia National Laboratories. ERMS #237497. 5.34
SANTOS Version 2.0 was originally validated for the CCA on the Cray platform. In April 2002,
Stone, C.M. 1997. SANTOS-A Two-dimensional Finite-Element Program for the QuasiStatic, Large Deformation, Inelastic Response of Solids. SAND90-0543. Sandia National
Laboratories, Albuquerque, New Mexico. 1997.
Mexico.1997. WIPP PA (Performance Assessment). Verification and Qualification Document for
SANTOS ERMS #235675. Sandia National Laboratories, Albuquerque, New Mexico. 1997.
WIPP PA (Performance Assessment). 1997. “Requirements Document and Verification and Validation Plan for SECOTP2D Version 1.41" Sandia National Laboratories. ERMS #245732.
WIPP PA (Performance Assessment). 1997. “Validation Document for SECOTP2D Version 1.41" Sandia National Laboratories. ERMS #245735.
WIPP PA (Performance Assessment). 1996. “Requirements Document and Verification and Validation Plan for SECOTP2D Version 1.30" Sandia National Laboratories. ERMS #236693. 5.36
WIPP PA (Performance Assessment). 1996. “Validation Document for SECOTP2D Version 1.30" Sandia National Laboratories. ERMS #236694.
SGSIM generates multiple realizations of the values of a parameter at locations defined on a two dimensional grid using the geostatistical Gaussian sequential simulation algorithm. The output is in the form of two ASCII text files – a diagnostic file and a file containing the SGSIM output. 5.36.1 Introduction The SGSIM, Version 2.0 code is an acquired code designed to solve the problem of simulating partially correlated values in one, two and three-dimensional domains conditional to measured values at random locations within the domain. In the context of the Culebra flow field calculations, SGSIM will be used to create the initial conditional residual fields that will then be updated by PEST (Section 5.25). Residual fields are necessary as the estimated mean transmissivity values (as estimated from the multiple regression tests) do not honor the transmissivity values at the measurement locations. SGSIM software is used on a PC running the Linux operating system. The SGSIM code is documented as specified in NQA-2a-1990 in the User’s Manual, the Requirements Document & Verification and Validation Plan, the Validation
Deutsch, C. V., and A.G. Journel, A.G., 1998. GSLIB: Geostatistical Software Library and User’s Guide: Second Edition , Oxford University Press, New York, 369 pp.
Deutsch, C.V., 1996, Direct Assessment of Local Accuracy and Precision, Geostatistics
WIPP PA, 2003, Software Quality Assurance Plan For SGSIM Version 2.00, Sandia National Laboratories, Albuquerque, New Mexico, ERMS #523914
WIPP PA, 2003, Requirements Document For SGSIM Version 2.00, Sandia National
WIPP PA, 2003, Verification and Validation Plan For SGSIM Version 2.00, Sandia National Laboratories, Albuquerque, New Mexico, ERMS #523914 5.37
SPLAT Version 1.01 was validated in May of 1996 on a DEC Alpha 2100 with OpenVMS 6.1 by demonstrating that the results of six test cases met the acceptance criteria defined in the RD/VVP for version 1.01 [2]. The validation for the test set used to perform functional testing for SPLAT 1.01 consisted of six test cases (VD for SPLAT 1.01 [3]). In October of 1996, SPLAT was revised to Version 1.02, which was validated with OpenVMS 6.1 on a DEC Alpha 2100 using seven test cases [1,2]. Test cases 1 through 4 were validated through regression testing while tests five and seven underwent acceptance testing (described in more detail below). The regression testing was accomplished by comparing the results from Version 1.02 to the results of Version 1.01 using the VMS DIFFERENCE utility. In Section 10.0 of the
[3] and documented in the associated VD [4]. The seventh test case was created to verify that the changes made for Version 1.02 were implemented correctly. It was validated by comparing output results to the defined set of acceptance criteria in the RD/VVP for SPLAT 1.02 [1]. In order to test new operating systems that were added in 2002-03 (Section 1), regression test results from SPLAT 1.02 run on the ES40 with OpenVMS 7.3-1 were compared to results from the validation tests of SPLAT 1.02 run on a DEC Alpha 2100 with OpenVMS 6.1. In June 2003, the Agency completed a report documenting the Agency’s approval with respect to the migration and verification of SPLAT 1.02 on those operating systems [5]. In January 2003, two new hardware systems were added to conduct performance assessments for the WIPP. A Compaq ES45, and a Compaq Alpha 8400 which are both running Open VMS 7.3-1[6,7]. The discussion
WIPP PA (Performance Assessment). 1996. “Requirements Document & Verification and Validation Plan for SPLAT Version 1.02" Sandia National Laboratories. ERMS #241866.
WIPP (Performance Assessment). 1996. “Requirements Document & Verification and Validation Plan for SPLAT Version 1.01" Sandia National Laboratories. ERMS #237482. 5.38
WIPP PA (Performance Assessment). 1996. “Validation Document for SPLAT Version 1.01" Sandia National Laboratories. ERMS #237485.
WIPP PA (Performance Assessment). 1996. “Validation Document for SPLAT Version 1.02" Sandia National Laboratories. ERMS #241867.
STEPWISE is a statistical code that evaluates variable importance by developing regression models between the observed response and input variables using either a forward, backward, or stepwise regression procedure on the raw or ranked data. STEPWISE 2.20 was validated in November 1995 on a DEC Alpha 2100 with OpenVMS 6.1 by demonstrating that the results of three test cases met the acceptance criteria defined in the RD/VVP for STEPWISE 2.20 [2].
STEPWISE 2.20 was used in the WIPP Compliance Certification Application (CCA). 5.38.1 Introduction In November of 1996, STEPWISE was revised to version 2.21. Version 2.21 was validated on the
WIPP PA (Performance Assessment). 1996. “Requirements Document & Verification and Validation Plan for STEPWISE Version 2.21" Sandia National Laboratories. ERMS #242250.
WIPP PA (Performance Assessment). 1995. “Requirements Document & Verification and Validation Plan for STEPWISE Version 2.20" Sandia National Laboratories. ERMS #227767.
SUMMARIZE 2.20 is a data integration and conversion utility code for the analysis of binary input data. SUMMARIZE reads data from CAMDAT binary data (CDB) files and generates one or more tabular ASCII text output files. 5.39.1 Introduction Since the Compliance Certification Application (CCA) the SUMMARIZE code has undergone a series of revisions. SUMMARIZE Version 2.10 was used in the WIPP CCA. SUMMARIZE 2.10 was validated in May 1996 on a DEC Alpha 2100 with OpenVMS 6.1 by demonstrating that the results of seven test cases met the acceptance criteria defined in the RD/VVP for SUMMARIZE 2.10. [2, 3] In August 1996 SUMMARIZE was revised to Version 2.15 and was validated on a DEC Alpha 2100 with OpenVMS 6.1 [5, 6]. Test Cases 2, 3, 5, 6 and 7 for the validation of SUMMARIZE 2.15 were identical to test cases for the validation of SUMMARIZE 2.10. The acceptance criteria for these test cases were satisfied by DOE in which they demonstrated that the output from
SUMMARIZE 2.15. In July 1997, SUMMARIZE was revised to Version 2.20 and was validated on a DEC Alpha 2100 with OpenVMS 6.1 [1, 2]. The validation test included the seven test cases defined for Version 2.15, and an additional Test Case 8. Test Case 8 was added to verify the correction of an error found in Version 2.15. Acceptance criteria for Test Cases 1-7 were satisfied by comparing output of SUMMARIZE 2.20 to the output of SUMMARIZE 2.15, while the acceptance criteria for Test Case 8 were satisfied by analysis of the output of SUMMARIZE 2.20.
DOE expected to find numerical differences in the output of Test Case 3. In order to test new operating systems that were added in 2002-03 (Section 1), regression test results from SUMMARIZE 2.20 run on the ES40 with OpenVMS 7.3-1 were compared to results from the validation tests of SUMMARIZE 2.20 run on a DEC Alpha 2100 with OpenVMS 6.1. In June 2003, the Agency completed a report documenting the Agency’s approval with respect to the migration and verification of SUMMARIZE 2.20 on those operating systems [7]. In January 2003, two new hardware systems were added to conduct performance assessments for the WIPP. A Compaq ES45, and a Compaq Alpha 8400 which are both running Open VMS 7.3-1[8,9]. The discussion below documents the test methodology, regression test results, and the Agency’s conclusions with respect to SUMMARIZE 2.20 on the new hardware systems. 5.39.2 Test Methodology The tests for this code comprised the eight test cases described in the Requirements Document & Verification and Validation Plan for SUMMARIZE Version 2.20 (RD/VVP) [1]. Regression test results from SUMMARIZE 2.20 run on the ES45 and 8400 with OpenVMS 7.3-1 were compared to results from the validation tests of SUMMARIZE 2.20 run on the ES40 with OpenVMS 7.3-1. The regression test methodology uses the VMS DIFFERENCE command to compare output from
WIPP PA (Performance Assessment). 1997. “Requirements Document & Verification and Validation Plan for SUMMARIZE Version 2.20" Sandia National Laboratories. ERMS #246449.
WIPP PA (Performance Assessment). 1996. “Requirements Document & Verification and Validation Plan for SUMMARIZE Version 2.10" Sandia National Laboratories. ERMS #237458.
WIPP PA (Performance Assessment). 1996. “Validation Document for SUMMARIZE Version 2.10" Sandia National Laboratories. ERMS #237461.
WIPP PA (Performance Assessment). 1996. “Requirements Document & Verification and Validation Plan for SUMMARIZE Version 2.15" Sandia National Laboratories. ERMS #240252.