VOC Emissions from Oil and Condensate Storage Tanks
Other documents for the same rulemaking
References
BPA, DFW, and HGB areas during May-July, 2006. The average VOC emission factors for oil and condensate storage tanks were 1.6 ± 99% lb/bbl and 33.3 ± 73% lb/bbl, respectively, where the uncertainties are represented by the 95% confidence intervals of the means (Table ES-1). Variable site characteristics such as separator temperature, separator pressure, and the physicochemical properties of the liquid hydrocarbons, in addition to very low condensate production rates at well sites in Denton and Parker counties are probable leading causes of the uncertainty. Table ES-1. Average, Standard Deviation, and Range of VOC Vent Gas Emission Factors Measured for Oil and Condensate Storage Tank Batteries Emission Factor (lb/bbl) Condensate Tanks a Number Sampled = 22 Oil Tanks Number Sampled =11 Arithmetic Mean 33.3 Standard Deviation 53.3 0.0 – 3.1 9.1 – 57.7 Minimum Maximum 215.1 Median 12.0 95% Confidence Interval for Mean Excludes data from one well site that was not representative of normal operating conditions Table ES-2 gives the total uncontrolled VOC emissions estimated for wellhead and gathering site storage tanks in the HGB, DFW, and BPA based on the arithmetic mean emission
CDPHE, 2004. Colorado State Implementation Plan for Ozone, Appendix C, Technical Support Document. Colorado Department of Public Health and Environment. February 26, 2004.
CDPHE, 2006. Oil and Gas Exploration & Production Condensate Tanks, an Overview of Air Quality Regulations. Colorado Department of Public Health and Environment. March 2006.
EPA, 1991. Compilation of Air Pollution Emission Factors. Volume 1: Stationary Point and Area Sources, Fifth Edition, AP-42, Section 13.5. Industrial Flares. U.S. Environmental Protection Agency, Office of Air Quality Planning and Standards, Research Triangle Park, NC. September 1991.
EPA, 2003. Lessons Learned from Natural Gas Star Partners: Installing Vapor Recovery Units on Crude Oil Storage Tanks. U.S. Environmental Protection Agency, Air and Radiation, EPA430-B-03-015. October 2003.
Gas Processors Association, 1995. Tentative Method of Extended Analysis for Natural Gas and Similar Gaseous Mixtures by Temperature Programmed Gas Chromatography. GPA Standard 2286-95, Gas Processors Association, Tulsa, OK. 1995. Lesair Environmental, Inc., 2003. Colorado E&P Storage Tank Emission Factor Development. Presented to the Denver Regional Air Quality Council, November 5, 2003. Accessed from http://www.raqc.org/ozone/EAC/Nov5/Lesair%20SPE%20Presentation%20100603.pdf on April 3, 2009.
ODEQ, 2004. Calculation of Flashing Losses/VOC Emissions from Hydrocarbon Storage Tanks. Oklahoma Department of Environmental Quality. July 19, 2004.
TCEQ, 2005. TexAQS II Remote Sensing VOC Project (information provided by TCEQ staff). May 2005.
TCEQ, 2006. 2005 Emissions Inventory Guidelines Technical Supplement 6: Above Ground Liquid Storage Tanks. Texas Commission on Environmental Quality. January 2006.