Official Proceedings of the 2014 International Water Conference DCN SGE01067.A01
Other documents for the same rulemaking (all, by stage)
References
CD ROM Proceedings of the International Water Conference, IWC 2005
Opara, A., et al (2014) Electro-Biochemical Reactor (EBR) Technology for Selenium Removal from British Columbia’s Coal Mining Wastewaters, Presented to SME Annual Meeting, Salt Lake City, UT
Enegess, D., (2012) New Concepts for Selenium Treatment using Fluidized Bed Reactor Technology, Presented to the Canadian Industry Selenium Working Group; Vancouver, CAN.
Webster, T., (2012) Overview of Fluidized Bed Reactor Technology for Selenium Treatment, Presented to the Canadian Industry Selenium Working Group; Vancouver, CAN. <<Back>> <<Next>> Prepared Discussion of: New Technologies to Reduce Long-Term Operations Cost of Biological Systems Removing Oxyanions in Water Treatment Operations Tony Vaughn Monsanto St. Louis, MO <<Back>> <<Next>>
Lenz, M. (2008). Biological selenium removal from wastewaters. Ph.D. Thesis, Wageningen University,
Wageningen, The Netherlands. Rutkowski, T., Hanson, R., & Conroy, K. (2013). Mine water treatment options for meeting stringent selenium regulatory limits. Proceedings of the International Mine Water Association Conference, August 2013.
Golden, CO, USA. Sandy, T., & DiSante, C. (2010). Review of available technologies for the removal of selenium from water. Prepared for North American Metals Council. CH2MHill.
Sandy, T., & DiSante, C. (2013). Addendum: Review of available technologies for the removal of selenium from water. Prepared for North American Metals Council. CH2MHill.
Soller, M., & Harwood, J. (2013). Case study on a selenium treatment system to treat combined flow of surface and underground mine wastewater. Proceeding of the International Water Conference (IWC-13-18), November 2013. Orlando FL.
Zhang, Y., Okeke, B. C., & Frankenberger, W. T., Jr. (2007). Bacterial reduction of selenate to elemental selenium utilizing molasses as a carbon source. Bioresource Technology, 99, 1267-1273. <<Back>> <<Next>>
Masscheleyn, Patrick; Delaune, Ronald; and Patrick, Jr., Willium. (1990). Transformation of Selenium As Affected by Sediment Oxidation-Reduction Potential and pH. Environ. Sci.
L. (1982). Process Chemistry for Water and Wastewater Treatment. Englewood Cliffs, NJ: Prentice-Hall.
Kumar, P. R., Chaudhari, S., Khilar, K.C., & Mahajan, S.P. (2004). Removal of Arsenic from Water by Electrocoagulation. Chemosphere, 55(9), 1245-1252.
Lakshmanan, D., Clifford, D. A., Samanta, G. (2010). Comparative Study of Arsenic Removal by Iron Using Electrocoagulation and Chemical Coagulation. Water Research, 44, 5641-5652.
NDEP Profile II. (2014, July 1). [PDF]. Retrieved from http://ndep.nv.gov/bmrr/file/ndep_profile_2.pdf
Reid, M. (2013). Stormwater Discharges Associated with Industrial Activity from Metals Mining Activities – Sector G Permit No. NVR300000 Fact Sheet. [PDF]. Retrieved from http://ndep.nv.gov/bwpc/docs/mining_fact_sheet_web_site.pdf
Tchobanoglous, G., & Burton, F. (1991). Wastewater Engineering: Treatment, Disposal, and Reuse. New York, NY: McGraw-Hill. <<Back>> <<Next>>
1. Peterson, D (2007). Guidelines for Produced Water Evaporators in SAGD. International Water Conference IWC-07-68 2. Glover ,W. Selecting Evaporators for Process Applications, Dec 2004, Chemical Engineering Progress
Boiler Feedwater Specification.(2009) Oil Sands and Heavy Oil Technologies Conference
4. Pinkas, J, The Chemistry of Silicates and AluminoSilicates (2005) Review Paper , Ceramics 287-298
5. Nagghappan, 2012, Method for Recovering Oil or Gas and Treating the Resultant Produced Water, US Patent Application 20120255904
6. Grant, US Patent 6416672 7. Davis C, Modeling Silica Sorption To Iron Hydroxide, 2002, Environ. Sci, 36, pp 582-587
Nanoscale, 2013,5,7054-7065 9. Pourbaix, M. Atlas of electrochemical equilibria in aqueous solutions. 2d English ed. 1974, Houston, Tex.: National Association of Corrosion Engineers.
10. Richardson, J et al(2000) “Quad Polymer Technology-Advances and Benefits for High Alkaline High Cycle Cooling Water Treatment, IWC 00-21, pp 245-253 Acknowledgements
SPE 54109 (March 1999 – Bakersfield, California): “Softening of Produced Water: Which system is best for your Operation?”
ASME, Consensus Documents on Operating Practices for the Control of Feedwater and Boiler Water Chemistry in Modern Industrial Boilers (CRTD-43), New York, 2003.
ASME, Consensus on Operating Practices for Control of Water and Steam Chemistry in Combined Cycle and Cogenerations Power Plants (CRTD-), New York, 2013.
Colleen M. Layman “Selecting a Combined Cycle Water Chemistry Program” Power, March 2013 <<Back>> <<Next>>
ASME document Consensus on Operating Practices for Control of Water and Steam Chemistry in Combined Cycle and Cogeneration Power Plants (ASME 2013). done in the design phase. The mitigation of flow-accelerated corrosion (FAC) is very much a case in point where better metallurgical choices are often disregarded, resulting in premature failures, often involving lost production and revenue. Other organizations (EPRI,
2. Carvalho, L., James, T., Hunter, W., Power Plant Chemistry, 2007, 9(10)
Oct.2001. <<Back>> <<Next>> IWC 14-26 Correct for Ammonia/Amine Effect on pH to Avoid Corrosion with Phosphate Treatment
ABSTRACT The current HRSG chemistry guide (ASME 2012) has an equation for the required correction for the effect of ammonia on boiler water or evaporator water pH and calculated sodium (Na) to phosphate (PO4) mole ratios. Controlling this sodium alkalinity associated with phosphate is more complicated than the old method of just staying within the pH/PO4 control box. Rigorous calculation of the ratio can be necessary to avoid corrosion of evaporator and boiler tubes. This is of greatest concern in units that have high tube metal temperatures and high underdeposit concentration of boiler water due to such factors as high operating pressure, high heat flux and/or thick, porous waterside deposits.
WHY IS THE RATIO IMPORTANT? The Na:PO4 mole ratio allows one to know the amount of free caustic or – if no caustic is present - the balance of sodium alkalinity to phosphate. High or low levels can contribute to corrosion on tube surfaces. Large amounts of free caustic (NaOH) can cause caustic gouging under deposits – particularly in boilers with circulation problems or high heat flux (Jacklin, 1964, Klein (1962)). Free caustic also can carry over into the steam and cause corrosion and stress corrosion cracking of turbine components.
HRSG tube surfaces. This is most common in boilers operating over 2000 psig, but it has occurred in a 1500 psig boiler (Selby, 1993). The Na:PO4 mole ratio cannot be calculated based on boiler water sodium analysis results unless all cationic and anionic species present also are quantified and the sodium concentration is adjusted to obtain the sodium concentration associated just with orthophosphate and hydroxide (measure and subtract the calculated amount of sodium associated with chloride, fluoride, bromide, sulfate, nitrate and nitrite).
Noll (1964) found that free caustic is generated above a ratio of 2.85:1 for 1235 psi boilers and above a ratio of 2.65 for 3000 psi boilers. At the time, it was suggested to treat these as maximum values to avoid caustic formation. Significant increases in corrosion were not expected until the sodium-to-phosphate mole ratio decreased below about 2.2:1 (Economy, 1975). However, subsequent experience and research found that other corrosion mechanisms can be experienced at sodium-to-phosphate mole ratios less than 3.0:1 – depending on the temperature and concentration mechanisms at tube surfaces.
SODIUM-TO-PHOSPHATE MOLE RATIO CONTROL LIMITS This paper is most useful for plants that operate with high ammonia (or amine) and low phosphate. For high-pressure HRSG plants with duct firing, the minimum suggested sodium-to-phosphate mole ratio is 2.8 (ASME 2012). The maximum limit corresponds to 1 ppm of free caustic above a sodium-to-phosphate mole ratio of 3.0:1. More caustic may be permitted for lower pressure HRSG units in industrial settings. For low-pressure industrial boilers, lower minimum sodium-to-phosphate ratios are permitted and sometimes advised. Lower minimum sodium-to-phosphate mole ratios are suggested when there is a large potential for caustic contamination in the system. The lower ratio can neutralize more caustic contamination and provide more time to respond to the contamination. The minimum sodium-to-phosphate mole ratio limit is never below 2.2, and the minimum increases with increasing operating temperature. For industrial boilers, the top sodium-to-phosphate ratio can be as low as 2.8:1 or above the 3.0:1 ratio and be controlled up to some fixed level of free caustic. At low sodium-to-phosphate mole ratios, the reaction of phosphate with magnetite can form an iron phosphate compound (e.g., Maricite).
Tremaine (1993) presented data indicating the ratios at which Maricite would be expected. Maricite formation has been associated with significant cases of phosphate gouging (also called acid phosphate corrosion). Whenever something starts to consume iron oxide as a reaction
ASME (2012). Consensus on Operating Practices for Control of Water and Steam Chemistry in Combined Cycle and Cogeneration Power Plants, Heat Recovery Steam Generator Chemistry Limits Task Group and the Water Technology Committee of the ASME Research and Technology Committee on Water and Steam in Thermal Systems, CRTD-100, ASME, New
Economy (1975) Economy et al. Sodium Phosphate Solutions at Boiler Conditions: Solubility, Phase Equilibria, and Interactions with Magnetite, International Water Conference, 1975.
Hach (2005). Nitrogen, Ammonia, Nessler Method (0.02-2.50 mg/L NH3-N), DR5000 Spectrophotometer Procedures Manual, November 05 2005, Version 2, Hach Company.
Hull, G. (2006) Hull, Emory H. and Robert D Bartholomew, Rigorous Calculation of Sodium-toPhosphate Mole Ratios for Phosphate Treatment Programs, PowerPlant Chemistry, Vol. 8, No. 9, 2006.
Jacklin C. (1961) Clarence Jacklyn, Waterside Failures in High-Pressure Boilers - A Field
Survey, Paper No. 61-W-271, ASME Winter Annual Meeting, 1961.
Klein, H. (1962) H. A. Klein, Use of Coordinated Phosphate Treatment to Prevent Caustic Corrosion in High Pressure Boilers, Combustion, Vol. 34, pp. 45-52, 1962.
Noll, D. (1964) D. Noll, Factors that Determine Treatment for High-Pressure Boilers, American
Power Conference Proceedings, 1964.
Selby (1993) Selby, K. Anthony, Luis Maringer V. Claudia Saavedra T., and Charles E.
Treatment, January/February 1993. Tremaine, (1993) Tremaine, et al., Phosphate Interactions with Metal Oxides Under HighPerformance Boiler Hideout Conditions, International Water Conference, 1993.
Verib, G. (2003) Development and Use of Sodium-To-Phosphate Ratios in a Fossil Fired Utility
Boiler, Seventh International Conference on Cycle Chemistry in Fossil Plants, June 3-5, 2003,