Official Proceedings of the 2014 International Water Conference DCN SGE01067.A01
Other documents for the same rulemaking (all, by stage)
References
OEM Engineering Manual. Version 3.2.2. October 2013. Snowpure LLC.
Jha, A, Gifford J. CEDI: Selecting the Appropriate Configuration. Power Engineering. August 2000.
Tate, J. Add Polish to High-Purity Water with EDI: Systems Combine RO and Ion Electrochemistry. Water Technology. August 2000.
Tate, J. Electrodeionization Basics: EDI provides a significant advantage to ultrapure water users. Water Technology. June 2010.
Tessier, D, Haas, W, Grafton, J. CostEffective Modular Electodeionization (EDI). Power-Gen International, 1996.
FEDI Technical Manual. Version 1.8 March 2013. Qua.
GE Water E-Cell EDI. October 2014 GE Power & Water Technologies. <<Back>> <<Next>>
Alexander, D., et al (1998). The Use of Electrodeionization for Recovery of Steam Generator Blowdown, EPRI PWR Chemistry Meeting.
Calay, J. and Goffin, C. (2000). The use of EDI to reduce the ammonia concentration in steam generators blowdown of PWR nuclear power plants. Power Plant Chemistry, Volume 2, No. 8.
Bengtsson, B., et al (2009). Experiences of Water Treatment Applications in Ringhals. Power Plant Chemistry, Volume 11, No. 1. <<Back>> <<Next>>
DiMascio, F, Wood, J, Fenton, J (1998). CONTINUOUS ELECTRODEIONIZATION Production of high-purity water with regeneration chemicals. The Electrochemical Society 26-29. <<Back>> <<Next>>
Veil, J.A., (August 2007). Use of Reclaimed Water for Power Plant Cooling. Oak Ridge, TN: Argonne National Laboratory and U.S. DOE NETL. <<Back>> <<Next>>
3. US EPA Document Number EPA-822-R-08-002, January, 2008 Health Effects Support Document for Boron 4. H. Robert Goltz, Chris Eicher & Naomi Levy, IWC-09-49 A Zero Liquid Discharge Process for Boron Recovery from FGD Wastewater 5. H. Robert Goltz, Ph.D. and Chris Eicher, The Dow Chemical Company, Midland, MI
Marston (2006) WO Patent 2006/110574 A1. 8. Vendor technical information provided by Tim Pearson of NextChem. tpearson@nextchem-analyzers.com 9. US20110024358 Apparatus and processes for removing boron from liquids Michael L.
Pudvay (2011) <<Back>> <<Next>>
1. Stookey, L. “Ferrozine-A New Spectrophotometric Reagent for Iron.” Analytical Chemistry. 1970, 42(7), pp.779-781.
2. Dooley, R. B. “Flow-Accelerated Corrosion in Fossil and Combined Cycle/HRSG Plants.” PowerPlant Chemistry. 2008, 10(2), pp. 68-89.
3. Waite, T. D., Torikov, A., Smith, J. D. “Photoassisted Dissolution of Colloidal Iron Oxides by Thiol-Containing Compounds.” J. Colloid and Interface Science. 1986, 112(2), pp. 412-420.
4. Baumgartner, E., Blesa, M., Maroto, A. J. G., “Kinetics of the Dissolution of Magnetite in Thioglycolic Acid Solutions.” J. Chem. Soc. Dalton Trans. 1982, 1649-1654.
5. IAPWS, Technical Guidance Document: Corrosion Product Sampling and Analysis for Fossil and Combined Cycle Plants (2013). Available from http://www.iapws.org <<Back>> <<Next>>
VGB PowerTech e.V. (2004). Guidelines for Feed Water, Boiler Water and Steam Quality for Power Plants/Industrial Plants. VGB-R 450 Le Second Edition.
The Nalco Water Handbook (2009). Third Edition.
Duff, J.H., Dvorin, R, Salem, E, (June 1968). Phosphate Removal by Chemical Precipitation. Second Workshop on Phosphate Removal Sponsored by U.S. Department of Interior. Federal Water Pollution Control Administration. Desalination Volume 322 (August 2013). Preparation of a nano-scale ceramic membrane and its application in the medium-pressure boiler with phosphate treatment. <<Back>> <<Next>>
ASTM (2007). D 5173, Standard Test Method for On-Line Monitoring of Carbon Compounds in Water by Chemical Oxidation, by UV Light Oxidation, by Both, or by High Temperature Combustion Followed by Gas Phase NDIR or by Electrolytic Conductivity, ASTM.
ASTM (2011). D6504, Standard Practice for On-Line Determination of Cation Conductivity in High Purity Water, ASTM.
Daniels, D (2009). Focus on Organics in Steam, Power, June 2009.
Mettler-Toledo (2007). TOC Measurement Protects High Pressure Cogeneration Assets, Power Generation News, #8, Jan 2007. <<Back>> <<Next>>
Mittal, D.; Mandigo, G. FGD Purge ZLD Reality at Enel. Aquatech International Corporation. McIlvaine Webinar. November 12, 2008.
Shaw, W. A. Fundamentals of Zero Liquid Discharge System Design. Power Magazine. October, 2011.
Como, V. Staying Afloat with New Water Regulations. Black & Veatch, 2012. Steam Electric Power Generating Effluent Guidelines; United States Environmental Protection Agency. See http://water.epa.gov/scitech/wastetech/guide/steam-electric/index.cfm. <<Back>> <<Next>>
Mashinski (2003). Biological Treatment of Agent and Energetic Hydrolysate Generated from the Washout of Mustard (HD) Munitions. Presented at the 9th Annual Industrial Waste Technical and Regulatory Conference, Water Environment Federation (WEF), April 13-16, San Antonio, Texas. Golder Associates, Inc. (2009). Presentation of ICB Technology to Bechtel Team, Pueblo, Colorado.
Nurdogan, Y.; Myler; C.A.; Lecakes, G.D.; Usinowicz, P.J.; Blumenstein, E.P (2011) Design of Immobilized Cell Bioreactors for Chemical Agent Hydrolysate Treatment. Proceedings of the 2012 WEFTEC Conference, New Orleans, LA, September 29 – October 3. <<Back>> <<Next>>
M. (2008). Geochemical and Biogeochemical Reaction Modeling, 2
Bethke, C. M. & Yeakel, S. (2012). The Geochemist’s Workbench User’s Guide, Version 9.0. Aqueous
J. (1974). The Improved Densification of Sludge from Neutralized Acid Mine Drainage. Journal of the South African Institute of Mining and Metallurgy 74: 340-348.
Dzombak, D., & Morel, F. (1990). Surface Complexation Modelling-Hydrous Ferric Oxide. John Wiley & Sons, Inc., New York.
D. (1970). High Density Sludge Process for Treating Acid Mine Drainage. In: Third Symposium Coal Mine Drainage Research, Mellon Institute, Pittsburgh, PA, pp 12-26.
E. (1988). The Use of Pre-aeration to Reduce the Cost of Neutralizing Acid Mine Drainage. In: Mine Drainage and Surface Mine Reclamation. U.S. Bureau of
F. (1970). High Density Sludge Treats Acid Mine Water. Coal Age September 90.
Stumm, W., & Morgan, J. (1995). Aquatic Chemistry 3 Edition. Wiley, New York.
Yong, G. W. et al. (2005). Densification of Iron (III) Sludge in Neutralization. Int J Miner Process 76: 149-162.
C. (1999). Dense-Sludge Process for Reduced AMD Sludge Disposal. Min Eng 51: 46-50. <<Back>> <<Next>>
INTRODUCTION For nearly two decades, biological treatment systems – and in particular bioreactors - have been a part of the environmental treatment landscape with hundreds of installations in North America treating a broad range of contaminants. In recent times, biological treatment systems such as the Fluidized Bed Reactor (FBR) have had significant success in oxyanion treatment applications such as perchlorate, nitrate and chromate removal because of their high performance, their low long-term operating costs and their inherent sustainability compared to other forms of treatment. In a 2010 report by the North American Metals Council, the Fluidized Bed Reactor (Sandy, DiSante 2010) was deemed ‘best-in-class’ technology for the treatment of selenium in mining waters. This set off substantial efforts surrounding the FBR and other bioreactor systems for the treatment of selenium. That activity has spread to the Power Industry in the treatment of selenium in flue-gas desulfurization (FGD) wastewater in a series of pilots that have been designed to understand best practices for this application. Finally, the work in these newer applications has uncovered potentials for improving treatment options and lowering project costs for other oxyanions – such as nitrate and perchlorate.
Sandy, T.; DiSante, C., 2010 Review of Available Technologies for the Removal of Selenium from Water, Prepared for the North American Metals Council.
Sutton, P.M.; Greene, M., 1999 Perchlorate Treatment Utilizing GAC and Sand Based Biological Fluidized Bed Reactors. Proceedings of the Water Environment Federation 72 Annual Conference & Exposition, New Orleans, LA, October.
Webster, T.; Guarini, W.; Wong, H.S. (2009) Fluidized Bed Bioreactor Treatment of Perchlorate-Laden Groundwater to Potable Standards, Journal AWWA, 101 (5), 137-151
Sutton, P.M, (2006) Bioreactor Configurations for Ex-Situ Treatment of Perchlorate: A Review, Proceedings of the Water Environment Federation, WEFTEC 2006; Dallas, TX.
Munirathinam, K; Srinivasan, R. Tudini, J.; Sandy, T.; Harrison, T. (2011) Selenium Treatment of Mine Water Effluent in a Fluidized Bed Reactor (FBR), CD ROM Proceedings of the Water Environment Federation, WEFTEC 2011; San Diego, CA.
Pound, M.; Austin, S.; Coons, M.; Webster, T. (2005), Sequential Biological Treatment of Groundwater Contaminated with Mixed Recalcitrants. CD ROM Proceedings of the Eighth International In Situ and On-Site Bioremediation Symposium; Baltimore, Maryland.
Togna, P.; Delvecchio, M.; Webster, T.; Hines, B.; Cheung, M.; Bailey, L.K. (2005), Treating High Concentrations of Perchlorate in Groundwater Using a Two-Stage Advance Bioreactor Design,