Detailed Study of the Centralized Waste Treatment Point Source Category for Facilities Managing Oil and Gas Extraction Wastes [DCN SGE01443]
Other documents for the same rulemaking (all, by stage)
References
Env, 2011, degasification, and 2011; All media filtration. Consulting, 2011f
NR—Not reported Only includes the primary treatment unit, not storage for wastewater, chemicals, or sludge (solid waste). Biological Treatment Biological treatment is a broad category of treatment which includes many different technologies. This section provides an overview of biological treatment and discusses the specific technologies most commonly used for oil and gas extraction wastewater. 6.7.1 Principle and Process Description Biological wastewater treatment systems use microorganisms to consume biodegradable soluble organic contaminants and bind the less soluble portions into flocculant, which is removed from the system typically in a clarifier. Biological treatment may be aerobic, anaerobic, anoxic, or a combination of these technologies. Aerobic biological treatment is the degradation of organic impurities by bacteria that can thrive in the presence of oxygen (also called aerobes) (Mittal, 2011); this treatment takes place in an aerobic bioreactor which is typically aerated. Anaerobic biological treatment is the degradation of organic impurities by bacteria that thrive only in the absence of oxygen (also called anaerobes) (Mittal, 2011). Anoxic systems are typically used for denitrification (conversion of nitrate to nitrogen gas) using facultative bacteria that thrive in the absence of dissolved oxygen and instead use oxygen in the form of nitrous oxides.
EPA collected samples in September 2016 at Eureka Resources that incorporated MBRs as part of the treatment train. Table 6-33 shows the data collected at this facility for pollutants of interest. As can be seen from these data, the systems removed constituents found in oil and gas extraction wastewaters, including oil and grease/hexane extractable material, , diesel range organics, total petroleum hydrocarbons, and alcohols (additional data can be found in U.S. EPA, 2017). Table 6-33. EPA MBR Sampling Data at Eureka Resources Constituent Influent Concentration Effluent Concentration Calculated Removal Efficiency Ammonia (mg/L) 41.1 0.259 99.4%
ND (0.25) ND – Not Detected (Detection Limit value in parenthesis) Source: U.S. EPA, 2017 Note: EPA used the reported detection level in calculating the removal efficiency.
EPA identified limited performance data for biological treatment specific to oil and gas extraction wastewater treatment in the literature. Kose et al. (2012) evaluated the performance of a submerged MBR in the laboratory for the treatment of brackish oil and natural gas field produced water in Turkey. Table 6-34 presents the results of this study. Reductions in COD, oil and grease and TPH were reported. Table 6-34. MBR Laboratory Performance Data Constituent Reported Influent Range (mg/L) Reported Effluent Range (mg/L) Reported Removal Efficiency 1,500 – 3,000 <500 80 - 85 31 - 50 7 - 15 60 - 85 1,030 – 2,210 <8 - 185 82 - 99 Oil and Grease Source: Kose et al., 2012 6.7.2.1 Design and Operation Considerations Biological processes can be sensitive to variations in influent flow and organic loads.
Systems, 2015 Kubota Submerged Membrane Unit® (SMU) Submerged Membrane 86 – 6,243
KUBOTA Corp., 2015 ADI-AnMBR Anaerobic Membrane Bioreactor
ADI Systems Inc., 2015 NR—Not reported Only includes the primary treatment unit, not storage for wastewater, chemicals, or sludge (solid waste). Summary The preceding discussions described technologies that EPA identified that are currently being used at CWT facilities to treat oil and gas extraction wastewaters. In addition to those technologies previously described, there are additional technologies that are or have been used as part of a treatment train at these facilities, for example for polishing of treated effluent prior to discharge or as pretreatment steps prior to other technologies. An example of such a technology is ion exchange. Additionally, other technologies have been used or researched for treating oil and gas extraction wastewaters, either in the laboratory or at other (non-CWT) facilities that may be applicable to CWT facilities. These include electrocoagulation, electrodialysis reversal, capacitative deionization, membrane distillation and forward osmosis. Many of these technologies are described by Ahmadun et al. (2009).
Author, Year 212 Resources, 2011 Acharya, 2011
ADI System Inc., 2015 Study Scale Full Scale Bench Scale Full Scale
All Consulting, 2006 All Consulting, 2011a
All Consulting, 2011b All Consulting, 2011c Multiple Full Scale Full Scale Full Scale Source Type
Author, Year Horn et al., 2013 Horn, 2009
INTEVRAS Technologies, LLC, 2011 JS Meyer Engineering, 2015
Keister, 2012 Kose et al., 2012 KUBOTA Corporation, 2015 Study Scale Full Scale Pilot Scale Full Scale Source Type Full Scale Pilot Scale Bench Scale Full Scale The EPA considered sources as verifiable if we were able to find information about the author outside of the reference document. For example, EPA primarily verified information by looking for company/organization websites that confirmed the author’s affiliation with the oil and gas extraction industry.
Author, Year All Consulting, 2011d All Consulting, 2011e
All Consulting, 2011f Anguil Aqua Systems, 2016
Asano, 2007 AquaTech International Corporation, 2011
Beckman, 2008 Bruff, 2011 CARES, Unknown CO Department of Public Health and Env, 2011 Colorado School of Mines (CSM), 2009 Crittendon et al., 2005
Dale, 2013 Study Scale Full Scale Full Scale Full Scale Full Scale Pilot Scale Full Scale
ERG, 2012a ERG, 2012b Ecolotron, 2012 Ecosphere Technologies Inc., 2011 Fairmont Brine Processing, 2015
Gradiant, 2016 Hayes, 2004 Hayes et al., 2012 Heartland Technology
Partners, LLC, 2014 6.10 Source Type Author, Year
Puder, 2006 Study Scale Pilot Scale Bench Scale Pilot Scale Full Scale Full Scale Full Scale Source Type Pilot Scale Multiple Full Scale Full Scale
Shaw, 2011 Multiple Full Scale Full Scale Full Scale Multiple
Silva, 2012 Full Scale Multiple Pilot Scale
Smith, 2014 Sutton, 2006 Full Scale Multiple Full Scale Full Scale Full Scale Demonstration Scale Full Scale U.S. EPA, 1998 U.S. EPA, 2000a U.S. EPA, 2013a U.S. EPA, 2013b U.S. EPA, 2014 U.S. EPA, 2015a U.S. EPA, 2015c Pilot Scale Demonstration Scale Multiple Multiple Full Scale Multiple Full Scale Pilot Scale Full Scale U.S. EPA, 2015d Full Scale Full U.S. EPA, 2015e Full Scale Full Scale Pilot Scale Full Scale Full Scale U.S. EPA, 2015f
URS, 2011 Ziemkiewicz et al., 2012 Full Scale Full Scale Bench Scale References 212 Resources. 2011. Vendor profile: 212 Resources. All Consulting. DCN CWT00112
Acharya, Harish; Henderson, Claire; Matis, Hope; Kommepalli, Hareesh; Moore, Brian; Wang, Hua, 2011. Cost Effective Recovery of Low-TDS Frac Flowback
NETL. (June). DCN CWT00005 Adams, Andy. 2011. EVRAS Evaporation Technology. Intevras & Layne Water. (September 26). DCN CWT00058
ADI System Inc. 2015. Vendor Profile: Anaerobic Membrane Bioreactor (ADIAnMBR). Available at: http://www.adisystemsinc.com/pdfs/ADI_AnMBR_brochure_Final.pdf. DCN CWT00185. DCN CWT00185 Ahmadun et al., 2009. Review of Technologies for Oil and Gas Produced Water Treatment. Journal of Hazardous Materials. Volume 179 (2-3). DCN CWT00322
Alexander, Jerry. 2011. Telephone Communication with J. Alexander, Siemens, S. Hays, ERG “Siemens Reverse Osmosis Technology.” (September 28). DCN CWT00059 All Consulting, LLC. 2006. A Guide to Practical Management of Produced Water from Onshore Oil and Gas Operations in the United States. Interstate Oil and Gas Commission and ALL Consulting. (October). DCN CWT00318
All Consulting. 2011a. Vendor Profile: Altela. DCN CWT00238
All Consulting. 2011b. Vendor Profile: AquaTech. DCN CWT00231
All Consulting. 2011c. Vendor Profile: GeoPure Hydrotechnologies. DCN CWT00232
All Consulting. 2011d. Vendor Profile: INTEVRAS Technologies, LLC. DCN CWT00233
All Consulting. 2011e. Vendor Profile: MISWACO. DCN CWT00234
All Consulting. 2011f. Vendor Profile: Veolia. DCN CWT00235
All Consulting. 2011g. Water Treatment Technology Fact Sheet: Crystallization.
DCN CWT00011 All Consulting. 2011h. Water Treatment Technology Fact Sheet: Reverse Osmosis. DCN CWT00012
Anguil Aqua Systems. 2016. Frac Water Reuse Technologies. DCN CWT00248 AquaTech International Corporation. 2011. Mobile Water Distillation System. Online at: http://www.aquatech.com/portals/0/MoVap%20Cut%20Sheet-01.pdf.
DCN CWT00239 Asano, Takashi. 2007. Water Reuse: An Integrated Approach to Managing the World’s Water Resources. McGraw-Hill. DCN CWT00008
Beckman, James R. 2008. Devaporation Desalination 5,000-Gallon-per-Day Pilot Plant. Desalination and Water Purification Research and Development Program Report No. 120. (June). Contract No. 03-FC-81-0905. DCN CWT00009
Bruff, Matthew. 2011. An Integrated Water Treatment Technology Solution for Sustainable Water Resource Management in the Marcellus Shale. Altela Inc., Argonne National Laboratory. DCN CWT00102
Burnett, D. 2011. Telephone Communication with David Burnett, Global Petroleum Research Institute, and Sarah Hays, Eastern Research Group, Inc. DCN CWT00314
CO Department of Public Health and Env. 2011. CDPS Fact Sheet To Permit Number CO0048739 Bopco, L.P., Yellow Creek Water Mgmt Facility Rio Blanco Co. DCN CWT00236 Colorado School of Mines (CSM). 2009. An Integrated Framework for Treatment and Management of Produced Water, 1st edition (November). DCN CWT00188
Crittenden, John, et al., 2005. Water Treatment: Principles and Design. John Wiley & Sons, Inc. 2nd edition. DCN CWT00027
Dale, Walter. 2013. H20ForwardSM Service – Sustainable Development of Completions. Halliburton. Technical presentation presented at the 2013 Produced Water Reuse Initiative Conference (October 30). DCN CWT00048 Eastern Research Group, Inc. (ERG). 2016a. 6th Annual Shale Plays Water Management Marcellus and Utica 2016 Conference Notes. DCN CWT00249 Eastern Research Group, Inc. (ERG). 2016b. CoilChem, LLC Treatment Technology Memorandum. DCN CWT00246 Eastern Research Group, Inc. (ERG). 2016c. Unconventional Oil and Gas (UOG) Produced Water Volumes and Characterization Data Compilation Memorandum.
DCN CWT00323 Eastern Research Group, Inc. (ERG). 2014. Notes on Meeting with Hydrozonix,
LLC on 7 February 2014. DCN CWT00241 Eastern Research Group, Inc. (ERG). 2012a. Notes on Conference Call with 212 Resources. Eastern Research Group, Inc. DCN CWT00029 Eastern Research Group, Inc. (ERG). 2012b. Notes on Conference Call with Reserved Environmental Services, LLC, and Eastern Research Group, Inc. (February 1). DCN CWT00015