Detailed Study of the Centralized Waste Treatment Point Source Category for Facilities Managing Oil and Gas Extraction Wastes [DCN SGE01443]
Other documents for the same rulemaking (all, by stage)
References
URS, 2011 Reference N/A—Not applicable; NR—Not reported Represents rental cost if the cost basis was rental and is inclusive of O&M. Represents total effective cost when cost basis is purchase, which includes amortized capital costs and O&M costs combined. When the cost basis is purchased, total effective cost is included only when a reference reported amortized capital costs. This is the estimated capital cost for the entire treatment plant. Costs for just the chemical precipitation treatment system were not provided. Table 6-7. Chemical Precipitation Costs at CWT Facilities Type of Service Commercial CWT Price for Treatment ($ per bbl) 7 to 9b 15 to 18b 4 to 7c 3.36 to 21c
ERG, 2012a Nuverra Appalachian Water Services U.S. EPA, 2015d Patriot Water Treatment Discharge to POTW U.S. EPA, 2015e
All Consulting, 2011b CoilChem, LLC CoilChem Mobile System Mobile System Mobile System 20,000
ERG, 2016b 1,100 10,000 Hayes et al., 2012 Reference Anguil Aqua Systems, 2016 Fountain Quail Water
Gradiant, 2016 JS Meyer Engineering Mobile System
JS Meyer Engineering, 2015 Frac Water Reclamation System Mobile System 3,000 M-I SWACO, 2009
CWT facilities often use physical separation technologies including filtration, flotation, and sedimentation to remove free oil and TSS. CWT facilities most often use filtration/sedimentation/flotation to treat oil and gas extraction wastewater prior to reuse, or as a component of a treatment train prior to other physical, chemical or biological treatment. In addition, filtration or sedimentation is typically a component of a chemical precipitation system to remove precipitates. 6.3.1 6.3.1.1 Principle and Process Descriptions Filtration Filtration works by routing wastewater through a porous media composed of rock, glass, walnut shell, sand, or other suitable material to separate oil and suspended solids. Gravity, centrifugal force, pressure, or a vacuum forces the wastewater through the media, which may be a single fixed bed, multiple fixed layers, or a moving bed (U.S. EPA, 1998). Suspended solids are trapped in the pores between the grains of the media (typically greater than 3 µm) and remain as the water passes through. As the media filter captures increasing amounts of solids, the pressure drop across the filter bed increases until it reaches a threshold at which point a backwash cycle is used to remove the accumulated solids. Filter backwash is typically recycled
Streams, LLC) reported that oil and gas extraction operators paid CWT facilities $1.00 per barrel to treat oil and gas extraction wastewater with 100,000 mg/L TDS for reuse using filtration, sedimentation, and flotation treatment (U.S. EPA, 2014).
URS, 2011 Sedimentation Purchase or Rental 0.63 0.15-0.40
Smith, 2014 Gas Flotation Purestream Purchase or Rental 0.11 2.40-3.80 0.50 Purestream, 2011; U.S. EPA, 2013b
NR—Not reported; MGD—million gallons per day; gpd—gallons per day; bbl—barrels. Capital costs are based on the MGD capacity of the facility. Represents rental cost if the cost basis was rental and is inclusive of O&M. Represents total effective cost when cost basis is purchase, which includes amortized capital costs and O&M costs combined. 6.3.4 Vendors Table 6-11 lists vendors of filtration, sedimentation, and floatation technologies that EPA has identified that offer treatment systems designed specifically for oil and gas extraction wastewater. Table 6-11. Filtration/Sedimentation/Flotation Technology Vendors for Oil and Gas Extraction Wastewater Technology Surface Vendor Technology Name Footprint (ft2)a Capacity (bpd) Reference Anguil Aqua Anguil Aqua Systems, Sedimentationb Systems 2016 FilterSure Media Filtration Trailer mounted 5,000
Ziemkiewicz, 2012 Purestream Gas Flotation
IGF and IGF+ Trailer mounted 2,500 U.S. EPA, 2013b
NR—Not reported; IGF—induced gas flotation separator; IGF+— induced gas flotation separator plus. Only includes the primary treatment unit, not storage for wastewater, chemicals, or sludge (solid waste). This vendor offers a chemical precipitation treatment technology that incorporates tube settlers into the process. Evaporation/Condensation Evaporation/condensation is used by CWT facilities to separate high TDS wastewater into distilled water and concentrated brine. Evaporation/condensation may be used when very pure treated water is desired (e.g., to meet requirements for discharging to streams or POTWs) (Metcalf and Eddy, 2003) or when costs for alternative disposal are high (e.g., in the Marcellus because of limited availability of disposal wells) (U.S. EPA, 2012, Colorado School of Mines, 2009, U.S. EPA, 2015a; Kasey, 2009). Evaporation/condensation is also useful where TDS exceeds approximately 50,000 mg/L, as other TDS removal technologies such as reverse osmosis become ineffective (see Section 6.6). At higher TDS concentrations, evaporation/condensation
EPA identified two references with field-scale performance data on evaporation/ condensation of oil and gas extraction wastewaters. The first (Bruff, 2011) evaluated the performance of an Altela ARS-4000 thermal distillation system treating Marcellus well wastewater. This study included both bench-scale and field-scale testing. In the field-scale testing, the system was operated from August 2010 through April 2011. Pretreatment prior to the evaporation system consisted of a 100-micron bag filter to remove suspended solids. Performance data for pollutants of interest are presented in Table 6-12. These results are calculated averages from four reported sampling events. The system demonstrated removal of This is the approximate supersaturation concentration for sodium chloride, the primary component of TDS found in oil and gas extraction wastewater. Several vendors indicated that supersaturation occurs at approximately 300,000 mg/L TDS (Mertz, 2011; ERG, 2011d; Wilson, 2011).
TDS and chloride, COD, barium and strontium, radium, bromide and acetone. A second reference (Hayes et al., 2012) evaluated the performance of an MVR system treating shale gas wastewater from wells in the Barnett Shale in Texas. Water samples were collected twice weekly during a 60-day period in 2011, yielding 18 days of samples. Pretreatment prior to the MVR consisted of clarification using caustic as well as addition of anti-foam agents and corrosion control and a five-micron bag filter. Performance data from the system for pollutants of interest is presented in Table 6-13. Influent data were collected after the clarifier and bag filter, and the paper presented median influent data collected from a combined dataset from three MVRs operated at the site. EPA calculated that the MVR system achieved a 99% reduction in TDS, a 98% reduction in barium, a 95% reduction in BTEX and a nearly 100% reduction in strontium. Table 6-12. Treatment Performance Data, Thermal Distillation Unit Average Influent Concentration Average Effluent Concentration Calculated Average Removal Efficiency mg/L 27,891 99.4% mg/L 94.6% mg/L 36.4 86.7% Chloride mg/L 12,256 75.2 99.3% Sodium mg/L 5,772 34.6 99.3% Barium mg/L 99.3% Strontium mg/L 99.3% Gross Alpha pCi/L 99.0% Gross Beta pCi/L
Mines, 2009; Mertz, 2011 50 kW Generatora Hayes et al., 2012; Roman, 2011 Uses Waste Heat from Compressor Stations or Runs on Natural Gas Heartland Technology Partners, 2014; U.S.
EPA, 2015c 60–90 Heartland Technology LM-HT® Partners
Shaw, 2011 Electricity, Natural Gas, Onsite Waste Bruff, 2011
Mines, 2009; Wilson, 2011 N/A—Not available; NR—Not reported; mg/L—milligrams per liter; MCF—million cubic feet; kWh— kilowatt-hour; bbl— barrel. Runs on natural gas directly from well head or electricity.
CWT Point Source Category for Facilities Managing Oil and Gas Extraction Wastes 6-19 Section 6Wastewater Management Practices 6.4.3 Costs Capital costs of evaporation/condensation include costs for the pretreatment system, the evaporation/condensation unit, low-pressure pumps, and monitoring equipment. Operating costs include energy for low-pressure pumps, energy for evaporation, brine management and disposal, and labor (Wilkerson, 2013; Dale, 2013). The technology is energy-intensive; however, several studies concluded that if waste heat (e.g., low-grade steam or low-grade natural gas) is used, the technology remains effective and cost is significantly reduced (Beckman, 2008, Colorado School of Mines, 2009, Bruff, 2011). Table 6-15 shows approximate capital and O&M costs for evaporation/condensation reported in the literature for purchased and rented treatment systems. The costs do not include pretreatment systems such as precipitation and filtration. Table 6-16 shows approximate prices charged by three CWT facilities that use(d) evaporation/condensation and the TDS concentration of the influent water that the evaporation/condensation system treated. All of the facilities use electricity or natural gas to power the evaporation/condensation treatment unit.
Purestream, 2011. U.S. EPA, 1998, ERG, 2016c Fountain Quail
Resources, LLC Indicates that facility has since closed. 6.4.4 Year of Cost 2012 2012 2012 Reference U.S. EPA, 2014
All Consulting, 2011a; Bruff, 2011 All Consulting, 2011g; All
Consulting, 2011b Purestream, 2011; Hayes et al., 2012
Purestream, 2011, Wilson, 2011 Gradient, 2016 Purestream Trailer mounted 1,000 – 2,500
Purestream, 2011 Heartland Technology LM-HT® U.S. EPA, 2015c Partners Veolia ~6,000
Shaw, 2011 NR—Not reported Only includes the primary treatment unit, not storage for wastewater, chemicals, or sludge (solid waste).
CWT Point Source Category for Facilities Managing Oil and Gas Extraction Wastes 6-22 Section 6Wastewater Management Practices Crystallization Crystallization converts high TDS wastewater into distilled water (low TDS) and solid salt crystals. Unlike evaporation/condensation that generates concentrated brine, as described in Section 6.4, crystallization can be used as a zero-liquid discharge (ZLD) technology if the distilled vapor is vented, rather than condensed. This technology may also be used for treating oil and gas extraction wastewater when very pure treated water is desired (e.g., to meet requirements for discharging to streams or POTWs) (Metcalf and Eddy, 2003) or when costs for alternative disposal are high (e.g., in the Marcellus because of limited availability of disposal wells) (U.S.
EPA collected samples in September 2016 at Eureka Resources, which incorporates crystallization as part of its treatment train. Table 6-18 shows the EPA crystallization sampling data collected at this facility for select pollutants of interest. As can be seen from these data, the crystallization removed constituents found in oil and gas extraction wastewaters, including bromide, COD, TOC, barium, strontium, boron, TDS, chloride, and radium 226 and 228. In addition, the alcohols ethanol and methanol increased in concentration after crystallization since
CWT Point Source Category for Facilities Managing Oil and Gas Extraction Wastes 6-23 Section 6Wastewater Management Practices these components evaporate and exit the system in the water vapor stream. Additional performance data can be found in U.S. EPA, 2017. Table 6-18. EPA Crystallization Sampling Data at Eureka Resources Units Influent Concentration Effluent Concentration Calculated Removal Efficiency Bromidea mg/L 0.186 100% Bromide mg/L
NOMAD Unit Purchase 300,000c Purchase 110,000 – Plant 130,000 Rental 40,000 – System Purchase 150,000 Plant System ~130,000 Rental Capacity (MGD) 0.21 O&M Rental or Capital Cost Effective Cost ($ per Cost ($ per gpd) bbl) ($ per bbl)b Reference U.S. EPA, 2012 0.25 3.50 11 to 22 0.25 3.70
Tinto, 2012 NR—Not reported The typical influent to the plant has a TDS concentration around 100,000 mg/L. The TDS concentration presented in the reference is the author’s assumed concentration for the actual influent to the crystallization unit, which is the effluent wastewater from an evaporator. Cost may be as low as $7 per barrel to the operator if the residuals can be sold for beneficial use to other industries. Costs were reported by the source; the author assumed that the hypothetical CWT facility is owned and operated by the vendor, and that the operator brings wastewater to the plant for treatment on a contractual basis. 6.5.4 Vendors Table 6-22 lists vendors of crystallization technologies that EPA is aware of that offer treatment systems designed specifically for oil and gas extraction wastewater.
INTEVRAS, 2011 Shaw, 2011 NR—Not reported; bpd—barrels per day; ft2—square feet. Only includes the primary treatment unit, not storage for wastewater, chemicals, or sludge (solid waste). Reverse Osmosis 6.6.1 Principle and Process Description In reverse osmosis (RO), pressure is used to force water through semi-permeable membranes that allow water, but not dissolved solids, to flow through. The RO membrane separates constituents from wastewater based not only on size differences but also based on electrostatic charge. RO membranes will repel most charged particles (ions) but allow neutral molecules like water and dissolved gases to pass through. Since TDS is primarily composed of ions such as sodium (Na+) and chloride (Cl-) that are repelled by RO membranes, RO is well suited for desalination provided the TDS concentration is not too high (Weber, 1972). The name “reverse osmosis” derives from osmosis, the spontaneous flow of water from a dilute solution to a concentrated solution, which occurs when the two solutions are separated by a semi-permeable membrane (Weber, 1972). In “reverse” osmosis, water flows from a concentrated solution to a dilute solution. This is accomplished when a pressure greater than the osmotic pressure is applied to the concentrated water, driving water through the membrane to the
CWT Point Source Category for Facilities Managing Oil and Gas Extraction Wastes 6-31 Section 6Wastewater Management Practices dilute solution. The membrane prevents ions from passing, leaving a concentrated solution behind (Metcalf and Eddy, 2003). In a typical wastewater treatment RO unit, hydraulic pumps apply pressure to the influent wastewater. The process requires pressures ranging from 250 to 1,180 psi, depending on the osmotic pressure (related to TDS concentration) of the influent wastewater (Hayes, 2004). The applied pressure pushes the water through the membrane while the membrane blocks the ions (TDS) from passing. The influent wastewater separates into two streams: treated wastewater and concentrated brine. In the literature, the treated wastewater is referred to as permeate and the concentrated brine is referred to as concentrate (Colorado School of Mines, 2009). 6.6.2 6.6.2.1 Capabilities and Limitations Targeted Pollutants and Treatment Effectiveness
RO is used to remove dissolved organic and inorganic constituents, such as ions, acids, sugars, dyes, natural resins, salts, BOD, COD, and radioactive elements from wastewater (Colorado School of Mines, 2009). The typical upper limit of TDS concentration in the wastewater for cost-effective operation is 45,000 to 50,000 mg/L (All Consulting, 2011h;
Alexander, 2011). Higher TDS concentrations increase osmotic pressure to the point where excessive energy is required to generate enough applied pressure to reverse the osmotic flow, making the process prohibitively expensive. RO can achieve effluent TDS concentrations less than 200 mg/L, depending on the composition of the influent wastewater (URS, 2011). One vendor suggests that RO is the most cost-effective treatment for oil and gas extraction wastewater when TDS is less than 30,000 mg/L (Alexander, 2011).
EPA collected samples in September 2016 at Eureka Resources, which incorporates RO as part of its treatment train. Table 6-23 shows the EPA RO sampling data collected at this facility for pollutants of interest. As can be seen from these data, the system removed constituents found in oil and gas extraction wastewaters, including COD, TDS, barium, strontium, and DRO (additional data can be found in U.S. EPA, 2017). In this case, RO is a final polishing step after the wastewater had already been treated by chemical precipitation, crystallization, membrane bio-reactor, and ion exchange. Table 6-23. EPA Reverse Osmosis Sampling Data at Eureka Resources Constituent Influent Concentration Effluent Concentration Calculated Removal Efficiency
DRO (mg/L) 0.828 0.0835 89.9% NC – Not Calculated Source: U.S. EPA, 2017 Note: EPA used the reported detection level in calculating the removal efficiency when possible.
All Consulting (2006) reported pilot-study data on the feasibility of membrane filtration technologies of a GE system for the treatment of produced water in California near
Bakersfield, shown in Table 6-24. Calculated percent removals of the RO component are 97 percent for sodium and 98 percent for chloride. The report also shows the intermediate performance data of the whole physical/chemical treatment system, which incorporated demineralization, ultrafiltration, followed by nanofiltration, and then RO. Data from Newpark Environmental Services cited in All Consulting (2006) from three locations treating produced water from CBM facilities are shown in Table 6-25. The data labeled as influent to RO is wastewater that had undergone physical/chemical pretreatment. The calculated percent reductions in TDS for these three locations ranged from 96.9 to 99.5 percent.
Horn (2009) provided data on the performance of a pilot-scale treatment system combining an advanced oxidation process with RO for treating produced waters in the Woodford Shale from Newfield Exploration. Data for the entire system is provided in Table 6-26 (the reference did not provide data for just the RO portion of the system). The system removed
Ecolotron (2012) provided data on the performance of an electrocoagulation system with a subsequent RO unit treating wastewaters from three locations. Table 6-27 provides performance data for the RO membrane treatment portion of this system. Removal of barium, strontium, sodium and chloride was reported.
Shafer (2010) reported on the performance of the Anticline Disposal treatment system in
ND – Not Detected Source: All Consulting, 2006 Permeate from ultrafiltration followed by nanofiltration, prior to RO. Table 6-25. Newpark Environmental Services Reverse Osmosis Performance Data Concentrations (mg/L)
Pinedale, WY Constituent Big Hills, TX Gillette, WY Influent Effluent Influent Effluent Influent Effluent Chloride 8,922 Sodium 5,140 1,358 3,004 19,053 93.1 Source: Newpark Environmental Services cited in ALL Consulting, 2006
NR—Not reported 6.6.3 Costs The major capital costs associated with RO are the RO unit and hydraulic pumps that can withstand the corrosivity of the high TDS in oil and gas extraction wastewater. A major operating cost associated with RO is membrane replacement, which is expected to occur every three to seven years for oil and gas extraction wastewater applications, according to Colorado School of Mines (2009). According to Burnett (2011), unconventional oil and gas wastewater treatment requires annual membrane replacement. Energy required for the pumps and brine management and disposal are the other major operating costs (Colorado School of Mines, 2009). Table 6-30 shows approximate RO capital and O&M costs. The reported data show that overall cost of RO units depends on influent wastewater quality. As influent TDS concentrations increase, the capital and operational costs increase. This is because larger and more robust pumps and membranes are required as the applied pressure increases (with the increase of TDS). Table 6-31 shows approximate prices CWT facilities charge to oil and gas extraction operators for treatment including RO. Costs do not include pretreatment steps.
Disposal, LLC water. Reuse treated wastewater Red Desert Tight in fracturing and Reclamation, <30,000 evaporate concentrated brine in ponds. Facility is no longer in commercial operation. 6.6.4 Commercial Price for Treatment ($ per bbl) 2.50 – 3.50 Year of Cost Reference 2006 Puder, 2006 2013 2.00 – 3.00
Horn, 2009 All Consulting, 5,000 None. 2011c All Consulting, 5,000 None. 2011e 2,500 – Omni Water Includes pretreatment. 10,000
Solutions, 2014 Alexander, Includes pretreatment. 2011; Asano, 2007