Voluntary Consensus Standard Results for National Emission Standards of Hazardous Air Pollutants: Primary Copper Smelting Supplemental Proposal
Other documents for the same rulemaking (all, by stage)
References
ASTM D3154-00 (2014) - Standard Method for Average Velocity in a Duct (Pitot Tube Method)
EPA Method 2 ASTM D3464-96 (2014) - Standard Test Method Average Velocity in a Duct Using a Thermal Anemometer
EPA Method 2 ASTM D3796-90 (2004) - Standard Practice for Calibration of Type S Pitot Tubes
EPA Method 2 ISO 10780:1994 - Stationary Source Emissions Measurement of Velocity and Volume Flowrate of Gas Streams in Ducts
ISO 10780:1994 recommends the use of an L-shaped pitot, which historically has not been recommended by EPA. The
EPA Method 2, 3A, 4, ASME B133.9-1994 (2001) - Measurement of Exhaust Emissions from Stationary Gas Turbine Engines (Revision of ANSI B133.9-1979)
ASME B133.9-1994 (2001) is the latest version. This method has been withdrawn with no further updates
EPA Method 3, 6C, 7A, ISO 10396:(2007) - Stationary Source Emissions: Sampling for the Automated Determination of Gas Concentrations
ANSI/ASME PTC 19-10-1981- Part 10 (2010) Flue and Exhaust Gas Analyses
EPA Method 3, 10 ISO 12039:2001(2012) - Stationary Source Emissions Determination of Carbon Monoxide, Carbon Dioxide, and Oxygen Automated Methods
ASTM D5835-95 (2013) - Standard Practice for Sampling Stationary Source Emissions for Automated Determination of Gas Concentration
EPA Method 5 ISO 9096:1992 (2003) - Determination of Concentration and Mass Flow Rate of Particulate Matter in Gas Carrying Ducts Manual Gravimetric Method This standard is unacceptable as a substitute for EPA Methods 3A, 6C, 7E, 10, 10A, and 20 (nitrogen oxides and oxygen parts of 20 only), since it does not include quantitative specifications for measurement system performance, most notably the calibration procedures and instrument performance characteristics. The instrument performance characteristics that are provided are nonmandatory and also do not provide the same level of quality assurance as the EPA methods. For example, the zero and span/calibration drift is only checked weekly, whereas the EPA methods requires drift checks after each run. Although sections of ISO 9096 incorporate EPA Methods 1, 2, and 5 to some degree, this ISO standard is not equivalent to
VOLUNTARY CONSENSUS STANDARD ANSI/ASME PTC-38-1980 (1985) - Determination of the Concentration of Particulate Matter in Gas Streams
ASTM D3685/D3685M- 98 (2013) - Test Methods for Sampling and Determination of Particulate Matter in Stack Gases
EPA Method 18 National Institute of Occupational Safety and Health (NIOSH) Method 2010 "Amines, Aliphatic"
EPA Method 18 ASTM D6060-96 (2009) - Practice for Sampling of Process Vents with a Portable Gas Chromatography
EPA Method 23 EN 1948-3 (2006) (European Committee for Standardization)-Determination of the Mass Concentration of PCDD’S/PCDF’S Part 3: Identification and Quantification
EPA Method 26, 26A EN 1911-1,2,3 (1998) - Stationary Source EmissionsManual Method of Determination of HCl-Part 1: Sampling of Gases Ratified European Text-Part 2: Gaseous Compounds Absorption Ratified European Text-Part 3: Adsorption Solutions Analysis and Calculation Ratified European Text
METHOD VOLUNTARY CONSENSUS STANDARD EN 1911-1,2,3 (1998) was replaced by EN 1911:2010
EPA Method 26, 26A ASTM D6735-01(2009) - Standard Test Method for Measurement of Gaseous Chlorides and Fluorides from Mineral Calcining Exhaust Sources Impinger Method
EPA Method 29 EN 13211:2001 - Air Quality Stationary Source Emissions Determination of the Concentration of Total Mercury
Since ASTM D4358-94 (1999) does not require the use of HF, it cannot be used in the preparation, digestion, and analysis of Method 29 samples.