Performance Specification 19 - Performance Specifications and Test Procedures for Ethylene Oxide (EtO) Continuous Monitoring Systems (Final)
Other documents for the same rulemaking
References
2. EPA Traceability Protocol for Assay and Certification of Gaseous Calibration Standards, U.S. Environmental Protection Agency office of Research and Development, EPA/600/R-12/531, May 2012. 17.0 Tables, Diagrams, Flowcharts, and Validation Data
1. EPA Traceability Protocol for Assay and Certification of Gaseous Calibration Standards, Office of Research and Development, National Risk Management Research Laboratory, May 2012, EPA 600/R12/531. https://www.epa.gov/air-research/epa-traceability-protocol-assay-and-certification-gaseouscalibration-standards
2. EPA Alternative Method 114, Approval of Alternative Method for preparation of HCl Gas Standards for PS-18 and Procedure 6, February 22, 2016, https://www.epa.gov/sites/default/files/202008/documents/alt114.pdf 3. Evaluation of Measurement Data — Guide to the Expression of Uncertainty in Measurement, JCGM 100:2008, https://www.bipm.org/documents/20126/2071204/JCGM_100_2008_E.pdf/cb0ef43f-baa511cf-3f85-4dcd86f77bd6 16.0 Tables and Figures Figure B-1 Example Gravimetric Preparation Sheet for GMPS and GMACS Figure B-2 Apparatus for the assay of the GMACs Figure B-3 Examples COA