Stack Test Report (11/17/2003) for Johnson & Johnson (San Angelo, TX)
Other documents for the same rulemaking
References: 3 extracted, 0 linked to papers
FOP Permit No. 0-02452 NSR Permit No. 20178 Account No. TG-0079-G Dear Mr. Madison: During September 15 through 19, 2003, Professional Environmental Services, Inc. (PES) conducted emissions testing for the scrubbers and catalytic oxidizers at the plant located in San Angelo, Texas. This testing was performed to satisfy the requirements of Title 30 Texas Administrative Code chapter 122 and the FOP. The attached reports indicate that all units tested were over 994'Ai efficient, as required by the Clean Air Act. Ethicon appreciates your active participation in pre-planning the tests and guiding us in making the testing process successful. Attached are two copies of the final report from PES Inc. It is my understanding that after completing your review, you will forward one copy of the report with your remarks to the TCEQ Region 8 office in San Angelo, Texas. I also understand that EPA Region 6 does not need a copy, Ethicon may voluntarily send them a copy. As you review the reports and have any questions, please contact me at (325) 482-5419, Harry Johantgen at (325) 482-5710 or Dennis Becvar of PES at (626) 962-3278. Tahseen Khan Attachments
EAST AND WEST FLUID BED SCRUBBERS Co11d11cted 011: September 15-18, 2003 Co11d11cted At:
PBR-086 / 09/12/1989 PRO-EAST East Sterilization Process