Corrected RLSO RegText - Commercial Sterilizers Reconsideration 04/02/2026
Other documents for the same rulemaking
References
2. EPA Traceability Protocol for Assay and Certification of Gaseous Calibration Standards, U.S. Environmental Protection Agency office of Research and Development, EPA/600/R-12/531, May 2012. 17.0 Tables, Diagrams, Flowcharts, and Validation Data Table 1—Interference Test Gas Concentrations Approximate concentration Potential interferent gas1 (balance N2) 1% ± 0.2% CO2 20 ± 5 ppm. H2 OH2O 5% ± 1% H2 OH2O.1 Balance.1 Any of these specific gases can be tested at a lower level if the manufacturer has provided reliableness for limiting or scrubbing that gas to a specified level in CEMS field installations. Table 2—Example Interference Test Data Sheet Table 3—Performance Specification Test Zero and Reference Gas Ranges Test Units EtO Zero and Reference Gas Concentrations in Terms of Percent of Spana Zero Low Level Calibration Drift % Of Span <LOD Measurement Error 20-30 % Of Span Mid-Level High Level 50-60 Section 80-100 11.5 80-100 11.4 Reference gas concentration must be NIST traceable. (See section 7.1) High-level is required. For DS calibration drift option, choose a concentration that yields a value in this range at the analyzer. Table 4—Student’s t-Values n-1a n-1a t-value n-1a t-value t-value
1. EPA Traceability Protocol for Assay and Certification of Gaseous Calibration Standards, Office of Research and Development, National Risk Management Research Laboratory, May 2012, EPA 600/R-12/531. https://www.epa.gov/air-research/epa-traceability-protocol-assayand-certification-gaseous-calibration-standards.
2. EPA Alternative Method 114, Approval of Alternative Method for preparation of HCl Gas Standards for PS-18 and Procedure 6, February 22, 2016, https://www.epa.gov/sites/default/files/2020-08/documents/alt114.pdf. 3. Evaluation of Measurement Data—Guide to the Expression of Uncertainty in Measurement,
JCGM 100:2008, https://www.bipm.org/documents/20126/2071204/JCGM_100_2008_E.pdf/cb0ef43f-baa5-11cf3f85-4dcd86f77bd6. 16.0 Tables and Figures Figure B-1 Example Gravimetric Preparation Sheet for GMPS and GMACS Figure B-2 Apparatus for the assay of the GMACs Figure B-3 Examples COA Attachment 4: Procedure 7 of 40 CFR 60 Appendix F regulatory text with proposed changes in redline/strikeout Title 40 → Chapter I → Subchapter C → Part 60→ Appendix F Title 40: Protection of Environment
1. EPA Traceability Protocol for Assay and Certification of Gaseous Calibration Standards, U.S. Environmental Protection Agency office of Research and Development, EPA/600/R-12/531, May 2012. 2. Method 205, “Verification of Gas Dilution Systems for Field Instrument Calibrations,” 40