Meeting Summary - Penske Trucking and American Trucking Association. Regarding Additional Data Collected by Penske on Class V Well Closure including Cost for Well Closure, Disposal of Sludge, Site Investigation and Disposal Alternative [W-98-05-I-F-7]
Other documents for the same rulemaking (all, by stage)
References
BACKGROUND The subject site is an operating truck rental and leasing facility providing maintenance services to over-the-road tractor trailers and other vehicles. Vehicle and service bay floor wash water was previously discharged through a subsurface clarifier and septic tank and finally discharged into the subsurface through a seepage pit. The disposal system is defined as a Class V injection well and is the subject of this work plan. The results of the previous investigation are detailed in the attached "Initial Site Assessment" report (SECOR, 1997). . In February 1997, SECOR advanced four soil borings in the vicinity of the seepage pit portion of the on-site Class V injection well to assess subsurface conditions. Soil sample collection and analysis was in compliance with EPA - Region 9 "Guidelines for Closure of Shallow Water Disposal Wells" dated 1992. Based on laboratory analytical results of soil samples collected, the previous discharge of wash water into the seepage pit portion of the Class V injection well had not adversely effected the area investigated.
HYDROGEOLOGIC SETTING The site is located in the Upper Santa Ana River Ground Water Basin, and more significantly within the Chino I Subbasin. Actual and potential ground water uses in the subbasin have been designated by the California Regional Water Quality Control Board, Santa Ana Region (RWQCB), and include municipal, domestic, agricultural, industrial service and industrial process supply (RWQCB, 1983). Based on the data obtained from the Fontana Water Company (FWC), the Marygold Mutual Water Company (MMWC) and the State of California Department of Water Resources (DWR), the depth to first "significant" ground water is estimated to be approximately 400 feet below ground surface (bgs) in the site vicinity. The reported regional ground water flow direction is southwest (FWC, 1996, MMWC, 1996, and DWR, 1970)". P.24 No known surface bodies of water (i.e. oceans, lakes, rivers) are located within a one-mile radius of the subject site (United States Geological Survey (USGS), 1967). The reported average annual rate of precipitation in the site vicinity is 15 inches (National Oceanic and Atmospheric
Administration, 1982). SITE ASSESSMENT ACTIVITIES Health and Safety Plan
SECOR International Incorporated, 1997, Initial Site Assessment, Penske Truck Leasing Facility, 14228 Slover Avenue, Fontana, California, April 7, 1997. Environmental Protection Agency, Region 9, 1992, Guidelines for Closure of Shallow Disposal
Wells, Revised May, 1993. P.27 FIGURES P.28 P.29
Administration, 1982). P.40 5.0 FIELD INVESTIGATION
GEOPROBE BORINGS On February 20-21, 1997, Maverick Environmental Services, under the direction of SECOR completed a geophysical survey to locate underground utilities and a subsurface Class V injection well. Following die completion of the geophysical survey four push-probe soil borings (B-1, B-2, B-2A and B-2B) were advanced adjacent to the injection well (Figure 2). Soil boring B-1 was advanced to 26 feet below ground surface (bgs) along the northwest corner of the injection well. Bedrock was encountered at 26 feet bgs within boring B-1 impeding further advancement. Soil boring B-2 was advanced along the southeast corner of the injection well. Refusal was encountered at 20 feet bgs within boring B-2. SECOR relocated the geoprobe rig approximately 4 feet south of boring B-2 (boring location B-2A) to try to attain a deeper soil sample near die southern portion of tie injection well. Boring B-2A met with refusal at approximately 16 feet bgs. A fourth boring location (B-2B) was advanced approximately 5 feet southeast of the boring B-2A. Boring B-2B also met with refusal at approximately 20 feet bgs. Ground water was not encountered within any of die soil borings advanced on site. No soil cuttings were generated during soil boring activities.
DWR (State Department of Water Resources), 1970, Meeting Water Demands in the Chino-Riverside
Area, Appendix A: Water Supply, Bulletin No. 104-3; report dated September 1970.
FWC (Fontana Water Company), 1996, Mr. James T. Bryson, general superintendent; oral communication on June 21, 1996.
MMWC (Marygold Mutual Water Company), 1996, Mr. Bill Stafford, superintendent; oral communication on June 21, 1996. National Oceanic and Atmospheric Administration, 1982, National Climate Center, Monthly Normals of
Temperature, Precipitation, and Heating and Cooling Degree Days, 1951-1980, California; Climatography of the United States No. 81, dated September 1982.
RWQCB (California Regional Water Quality Control Board, Santa Ana Region), 1983, Water Quality Control Plan, Santa Ana River Basin (8) - 1984; amended 1983.
USGS (United States Geological Survey), 1967, Fontana Quadrangle, 7.5 minute series topographic map; dated 1967, photorevised 1980.
IUGS Subcommission on the Systematics of Igneous Rocks, 1973, Classification and Nomenclature of Plutonic Rocks: Geotimes, V.18, n.10 (Oct.), p. 26-30.
RWQCB (California Regional Water Quality Control Board, Los Angeles Region), 1996, New Information Related to the Leaking Underground Storage Tank Program, April 22, 1996, Table 4-1. d\p\penskc\fontana. rpt P.45