{"document":{"doc_id":209814,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Meeting Summary - Penske Trucking and American Trucking Association. Regarding Additional Data Collected by Penske on Class V Well Closure including Cost for Well Closure, Disposal of Sludge, Site Investigation and Disposal Alternative [W-98-05-I-F-7]","date":"2026-09-21","url":"https://www.regulations.gov/document/EPA-HQ-OW-2002-0018-0410","source_native_id":"EPA-HQ-OW-2002-0018-0410","status":"fetched","abstract":null,"action":null},"dockets":["EPA-HQ-OW-2002-0018"],"rins":["RIN 2040-AB83"],"related":[{"doc_id":80541,"source":"ria","org":"EPA","doc_type":"economic_analysis","title":"Economic Analysis for the Proposed Revisions to Underground Injection Control Regulations for Class V Injection Wells Volume 1 [W-98-05 I-B-16]","date":null},{"doc_id":135302,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Form for Compliance with E.O. 12866 Docket Requirements [W-98-05 V-D-1]","date":null},{"doc_id":25729,"source":"fr_rule","org":"ENVIRONMENTAL PROTECTION AGENCY","doc_type":"Proposed Rule","title":"Class V WellsRegulatory Determination and Minor Revisions to the Underground Injection Control Regulations; Technical Correction to the Regulations for Class I Wells","date":"1995-08-28"},{"doc_id":24041,"source":"fr_rule","org":"ENVIRONMENTAL PROTECTION AGENCY","doc_type":"Proposed Rule","title":"Revisions to the Underground Injection Control Regulations for Class V Injection Wells","date":"1998-07-29"},{"doc_id":24126,"source":"fr_rule","org":"ENVIRONMENTAL PROTECTION AGENCY","doc_type":"Proposed Rule","title":"Reopening of Comment Period on Revisions to the Underground Injection Control Regulations for Class V Injection Wells","date":"1998-09-29"},{"doc_id":22851,"source":"fr_rule","org":"Underground Injection Control Regulations for Class V Injection Wells,; ENVIRONMENTAL PROTECTION AGENCY","doc_type":"Rule","title":"Revisions to the Underground Injection Control Regulations for Class V Injection Wells","date":"1999-12-07"},{"doc_id":80474,"source":"ria","org":"EPA","doc_type":"economic_analysis","title":"Economic Analysis for the Proposed Revisions to Underground  Injection Control Regulations for Class V Injection Wells, Addendum 1  [I-B.21] (Part 1)","date":"2004-01-07"},{"doc_id":80477,"source":"ria","org":"EPA","doc_type":"economic_analysis","title":"Economic Analysis for the Proposed Revisions to Underground Injection Control Regulations for Class V Injection Wells [I-B.20] (Part 6)\r\n","date":"2005-01-07"},{"doc_id":80482,"source":"ria","org":"EPA","doc_type":"economic_analysis","title":"Economic Analysis for the Proposed Revisions to Underground Injection Control Regulations for Class V Injection Wells (Part 1) [W-98-05 I-B-20]","date":"2005-01-07"},{"doc_id":80504,"source":"ria","org":"EPA","doc_type":"economic_analysis","title":"Economic Analysis for the Proposed Revisions to Underground Injection Control Regulations for Class V Injection Wells [I-B.20] (Part 5)\r\n","date":"2005-01-07"},{"doc_id":80514,"source":"ria","org":"EPA","doc_type":"economic_analysis","title":"Economic Analysis for the Proposed Revisions to Underground Injection Control Regulations for Class V Injection Wells [I-B.20] (Part 3)","date":"2005-01-07"},{"doc_id":80522,"source":"ria","org":"EPA","doc_type":"economic_analysis","title":"Economic Analysis for the Proposed Revisions to Underground  Injection Control Regulations for Class V Injection Wells, Addendum 1  [I-B.21] (Part 3)\r\n","date":"2005-01-07"},{"doc_id":80526,"source":"ria","org":"EPA","doc_type":"economic_analysis","title":"Economic Analysis for the Proposed Revisions to Underground Injection Control Regulations for Class V Injection Wells [I-B.20] (Part 4)\r\n","date":"2005-01-07"},{"doc_id":80535,"source":"ria","org":"EPA","doc_type":"economic_analysis","title":"Economic Analysis for the Proposed Revisions to Underground Injection Control Regulations for Class V Injection Wells [I-B.20] (Part 2)","date":"2005-01-07"},{"doc_id":169099,"source":"docket_item","org":"EPA","doc_type":"other","title":"Legacy Indexes for Docket W-98-05. See attachments","date":"2025-05-29"},{"doc_id":127384,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Form for Compliance with E.O. 12866 Docket Requirements. 1 p\n[W-98-05-III-D-1]","date":"2026-02-23"},{"doc_id":163333,"source":"docket_item","org":"EPA","doc_type":"report","title":"USEPA. Region II. March 1-3, 1999. U.S. EPA Region II Office Visit. Site Visit\nSummary and Copies of Region II Files. Volume 1, Book 1. [W-98-05-II-B-5]","date":"2026-02-23"},{"doc_id":163336,"source":"docket_item","org":"EPA","doc_type":"report","title":"Imperial Cleaners. Focused Remedial Investigation Work Plan.\n [W-98-05-II-B-7]","date":"2026-02-23"},{"doc_id":163341,"source":"docket_item","org":"EPA","doc_type":"report","title":"Penske Truck Leasing Company data/Class V Injection Well Information Summaries. 324 total pages. [W-98-05-II-B-2]","date":"2026-02-23"},{"doc_id":163343,"source":"docket_item","org":"EPA","doc_type":"report","title":"USEPA. Region VIII data for Class V Wells. 8 file folders. 704 pp. [W-98-05-II-B-8 1A-1K]","date":"2026-02-23"},{"doc_id":163344,"source":"docket_item","org":"EPA","doc_type":"data","title":"Minnesota Pollution Control Agency. Managing Floor Drains and Flammable traps. Hazardous Waste Division Fact Sheet #4. April. 1998. 5 pp. [W-98-05-III-C-1]","date":"2026-02-23"},{"doc_id":183662,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Environmental Protection Agency. 1999. Office of Ground Water and Drinking Water. Washington, DC. Revisions to the Underground injection Control Regulations for Class V Injection Wells: Final Rule. [W-98-05-II-B-3]","date":"2026-02-23"},{"doc_id":183665,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Environmental Protection Agency, Region 3. Superfund Site Fact Sheet, A. I. W. Frank/Mid-County Mustang Site, Pennsylvania, EPA ID# PAD004351003. [W-98-05-III-B-1]","date":"2026-02-23"},{"doc_id":210181,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Letter to Frank C. Brock, Chief Underground Injection Control Section, U.S. EPA  regarding Dry Well Closure Elmira Water Board Maintenance Facility [W-98-05-II-B-6]","date":"2026-02-23"},{"doc_id":210183,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"US EPA. 1999. Memorandum. Subject: Presentation at the Ground Water Protection Council on the status of the Revisions to the Underground Injection Control Regulations for Class V Injection Wells. From: Robyn Delehanty, Regulatory Manager. To: The Water Docket. November 19. 1 p. [W-98-05-III-C-2]","date":"2026-02-23"},{"doc_id":80530,"source":"ria","org":"EPA","doc_type":"economic_analysis","title":"Environmental Protection Agency. 1998. Office of Ground Water and Drinking Water. Washington, DC. Economic Analysis for the Proposed Revisions to Underground Injection Control Regulations for Class V Injection Wells. Volume 2. Draft. May 12. 77 pp [W-98-05-III-B-5]","date":"2026-03-09"},{"doc_id":80552,"source":"ria","org":"EPA","doc_type":"economic_analysis","title":"Environmental Protection Agency. 1999. Office of Ground Water and Drinking Water. Washington, DC. Economic Analysis for Final Rule: Revisions to the Underground Injection Control Regulations for Class V Injections Well. November 19. 152 pp [W-98-05-III-B-2]","date":"2026-03-09"},{"doc_id":127361,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"Form for Compliance with E.O.12866 Docket Requirements. 1 p [W-98-05-IV-D-1]","date":"2026-03-09"},{"doc_id":127362,"source":"docket_item","org":"EPA","doc_type":"review_record","title":"August 15, 1995. To Howard Beard, Acting Branch Chief, Underground Injection Control Branch from Lee Whitehurst. Changes to the proposed Class V rule in response to OMB review and comment. [W-98-05-UIC-PRO-H-1]","date":"2026-03-09"},{"doc_id":163264,"source":"docket_item","org":"EPA","doc_type":"report","title":"U.S. Environmental Protection Agency. 2001. Summary of the Management of Class V Industrial Waste Disposal Wells by Primacy State Programs. EPA Drinking Water Protection Division (DWPD). March 28,\n10 pp [W-98-05-IV-C-6]","date":"2026-03-09"},{"doc_id":163266,"source":"docket_item","org":"EPA","doc_type":"report","title":"Preparation and Review of UIC Area Permits for Enhanced\nOil Recovery Projects. Interstate Oil Compact Commission\nfor the U.S. EPA Region VI. Contract No. 68-03-1823. [W-98-05-UIC-I-B1-3]","date":"2026-03-09"},{"doc_id":163272,"source":"docket_item","org":"EPA","doc_type":"report","title":"Final Report Mechanical Integrity Testing of Injection Wells. [W-98-05-UIC-I-B1-2]","date":"2026-03-09"},{"doc_id":163273,"source":"docket_item","org":"EPA","doc_type":"report","title":"USEPA. Background Information Document: Class V\nIndustrial Well Inventory Analysis. August 1995 Draft. Office of Ground Water and Drinking Water. [W-98-05-UIC-PRO-C-1]","date":"2026-03-09"},{"doc_id":163278,"source":"docket_item","org":"EPA","doc_type":"other","title":"Environmental Protection Agency. 1999. Office of Ground Water and Drinking Water. Washington, DC. Revisions to Underground Injection Control Regulations for Class V Injection Wells. ICR Analysis of the Final Rule. EPA ICR No. 1874.02. November. 21 pp [W-98-05-III-B-4]","date":"2026-03-09"},{"doc_id":163279,"source":"docket_item","org":"EPA","doc_type":"report","title":"U.S. Environmental Protection Agency. 1999. Unified National Strategy for Animal Feeding Operations. United States Department of Agriculture and United States Environmental Protection Agency. March 1999. 55 pp [W-98-05-IV-C-3]","date":"2026-03-09"},{"doc_id":163280,"source":"docket_item","org":"EPA","doc_type":"report","title":"Annulus Pressure Monitoring Systems for Class I Wells.\nKen E. Davis Associates, Houston, TX. May 1987. for\nEngineering Enterprises Inc., Norman, OK. [W-98-05-UIC-I-B1-4]","date":"2026-03-09"},{"doc_id":163282,"source":"docket_item","org":"EPA","doc_type":"report","title":"USEPA. Expert Panel on Water Quality Impacts of\nAgricultural Drainage Practices, September 24-25, 1991\nMeeting Summary, Underground Injection Control Branch,\nUSEPA, September 28, 1992. [W-98-05-UIC-PRO-F-1]","date":"2026-03-09"},{"doc_id":163287,"source":"docket_item","org":"EPA","doc_type":"report","title":"93d Congress, 2d Session. House of Representatives: Report No. 93-1185. July 10, 1974. [W-98-05-UIC-PRO-C-3]","date":"2026-03-09"},{"doc_id":183576,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Indian Lands; National Primary Drinking Water and Underground Injection Control Regulations. July 27, 1987 Vol 52 FR 28112 (FRL 3210-61) [W-98-05-UIC-I-A2-9]","date":"2026-03-09"},{"doc_id":183577,"source":"docket_item","org":"EPA","doc_type":"publication","title":"U.S. Environmental Protection Agency. 1999. The Class V Underground Injection Control Study. Part 2, Volumes 11 through 23. Office of Ground Water and Drinking Water. EPA 816/R-99-014. September 1999. 904 pp. [W-98-05-IV-C-8-]","date":"2026-03-09"},{"doc_id":183587,"source":"docket_item","org":"EPA","doc_type":"publication","title":"U.S. Environmental Protection Agency. 1999. The Class V Underground Injection Control Study. Part 1, Volumes 1 through 10. Office of Ground Water and Drinking Water. EPA 816/R-99-014a. September 1999. 730 p. [W-98-05-IV-C-7-]","date":"2026-03-09"},{"doc_id":183592,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Federal Register: U.S. Environmental Protection Agency Indian Tribes; Eligibility for Program Authorization. Vol. 59. No. 239. Wednesday, December 14, 1994. pp. 64339 - 64360. [W-98-05-IV-B-12]","date":"2026-03-09"},{"doc_id":183593,"source":"docket_item","org":"EPA","doc_type":"publication","title":"U.S. Environmental Protection Agency. 1999. Report to Congress on Wastes from the Combustion of Fossil Fules. Office of Solid Wastes and Emergency Response. Volume 1 Executive Summary. EPA 530/S-99-010. March 1999. 39 pp [W-98-05-IV-C-4]","date":"2026-03-09"},{"doc_id":183594,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Federal Register: U.S. Environmental Protection Agency. Revisions of the State Drinking Water Act Underground Injection Control Regulations; Proposed Rule. Vol. 55, No.125. Thursday, June 28, 1990. pp. 26462-26469. [pp. 26464, 26466, 26468 are missing]. [W-98-05-UIC-I-A2-10]","date":"2026-03-09"},{"doc_id":183606,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Federal Register: U.S. Environmental Protection Agency. Notice of Regulatory Determination on Wastes from the Combustion of Fossil Fuels. Vol. 65 No. 99, Monday, May 22, 2000. pp. 32214 - 32260. [W-98-05-IV-B-18]","date":"2026-03-09"},{"doc_id":183612,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Federal Register: U.S. Environmental Protection Agency. National Pollutant Discharge Elimination System Permit Regulation and Effluent Limitations Guidelines and Standards for Concentrated Animal Feeding Operations; Proposed Rule. Vol.. 66 No. 9 Friday, January 12, 2001. pp. 2960 - 3145. [W-98-05-IV-B-19]","date":"2026-03-09"},{"doc_id":183613,"source":"docket_item","org":"EPA","doc_type":"publication","title":"Arnold, Frederic C. Modeling Variations in Annular\nPressure Due to Fluid Injection. Ground Water. C.29, No.\n6. Nov.- Dec. 1991. pp. 832-37. [W-98-05-UIC-I-B1-5]","date":"2026-03-09"},{"doc_id":183621,"source":"docket_item","org":"EPA","doc_type":"publication","title":"U.S. Environmental Protection Agency. 1999. Report to Congress. Wastes from the Combustion of Fossil Fuels. Volume 2 - Methods, findings and Recommendations. EPA 530-R-9-010. March 1999. 230 pp.\n[W-98-05-IV-C-5]","date":"2026-03-09"},{"doc_id":200432,"source":"docket_item","org":"EPA","doc_type":"other","title":"Environmental Protection Agency. 1999. Office of Ground Water and Drinking Water. Washington, DC. Revisions to the Underground injection Control Regulations for Class V Injection Wells: Final Rule. Comment and Response Document. November. 291 pp [W-98-05-III-B-3]","date":"2026-03-09"},{"doc_id":200433,"source":"docket_item","org":"EPA","doc_type":"other","title":"USEPA. Administrative Order on Consent to 10 Major\nPetroleum Marketing Companies. In the matter of Amoco\nCorporation and Omega Oil Company. Docket No. UIC\nNAO-91-01. September 11, 1991. [W-98-05-UIC-PRO-G-3]","date":"2026-03-09"},{"doc_id":200442,"source":"docket_item","org":"EPA","doc_type":"other","title":"USEPA. 2002. Comments and Responses for the Proposed Determination on Class V Wells Background Document. Prepared by: the Cadmus Group , Inc. Under Contract No. 68-C-99-245, Work Assignment 2-08. Prepared for: U.S. EPA, Office of Ground Water and Drinking Water. May 29 [W-98-05-V-C-1]","date":"2026-03-09"},{"doc_id":200457,"source":"docket_item","org":"EPA","doc_type":"other","title":"USEPA. Guidance Specifying Management Measures for\nSources of Nonpoint Pollution in Coastal Waters - Issued\nunder the Authority of Section 6217(G) of the Coastal Zone\nAct Reauthorization Amendments of 1990. 1995. Office\nof Wetlands, Oceans, and Watersheds. 822 pp. (NTIS:\nPB93234672) [W-98-05-UIC-PRO-C-2-]","date":"2026-03-09"},{"doc_id":200467,"source":"docket_item","org":"EPA","doc_type":"other","title":"Transcript of Public Hearing on August 20, 1990. Donald\nM. Olson, Chief. Attachment: Attendee List. 3 pp. [W-98-05-UIC-I-B1-6]","date":"2026-03-09"},{"doc_id":200485,"source":"docket_item","org":"EPA","doc_type":"other","title":"U.S. EPA. Office of Ground Water and Drinking Water.\nResponse to Comments Received on Proposed Revisions to\nthe Safe Drinking Water Act Underground Injection Control\nRegulations -- June 28, 1990. Oct. 4, 1993. 48 pp. [W-98-05-UIC-I-C1-1]","date":"2026-03-09"},{"doc_id":200494,"source":"docket_item","org":"EPA","doc_type":"other","title":"USEPA Region 3. July 15, 1998. Hazardous Site Cleanup Division. A.I.W. Frank/Mid-County Mustang, Pennsylvania. EPA ID# PAD004351003. Last Update: March, 1998. Superfund Site Fact Sheet. [W-98-05-I-B-17]","date":"2026-03-09"},{"doc_id":200495,"source":"docket_item","org":"EPA","doc_type":"other","title":"Petition for rulemaking. Sierra Club, Natural Resources Defense Council, and Friends of the Earth petition the EPA to promulgate technical standards and criteria for Class V underground injection wells. September 7, 1990. [W-98-05-UIC-PRO-G-1]","date":"2026-03-09"},{"doc_id":210149,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"From Mary Lou Rochotte, Supervisor, UIC Unit, DDAGW, State of Ohio Environmental Protection Agency to Rich Zdanowicz, Chief, UIC, USEPA Gegion V. August 1, 1995. [W-98-05-UIC-PRO-E-3]","date":"2026-03-09"},{"doc_id":210150,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"Congressional Receipt Letters: U.S. GAO, U.S. Senate, and U.S. House of Representatives. Nov. 29, 1999. FRL #6482-2. 3 pp. [W-98-05-III-E-1]","date":"2026-03-09"},{"doc_id":210152,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"USEPA. Class V Management Implementation Strategy.\nApril 12, 1995. Memorandum from Francoise M. Brasier,\nChief, Underground Injection Control Branch to UIC Section\nChiefs, Regions I - X [W-98-05-UIC-PRO-F-2]","date":"2026-03-09"},{"doc_id":210154,"source":"docket_item","org":"EPA","doc_type":"correspondence","title":"USEPA. Office of Ground Water and Drinking Water Strategy\nfor the Comprehensive Management of Class V Wells. May\n5, 1995. (The concepts of the Strategy were discussed at a Ground Water Protection Council meeting in Washington, DC, March 13, 1995. 5 pp. [W-98-05-UIC-PRO-B-8]","date":"2026-03-09"}],"references":[{"citation_id":2406648,"raw_reference":"BACKGROUND The subject site is an operating truck rental and leasing facility providing maintenance services to over-the-road tractor trailers and other vehicles. Vehicle and service bay floor wash water was previously discharged through a subsurface clarifier and septic tank and finally discharged into the subsurface through a seepage pit. The disposal system is defined as a Class V injection well and is the subject of this work plan. The results of the previous investigation are detailed in the attached \"Initial Site Assessment\" report (SECOR, 1997). . In February 1997, SECOR advanced four soil borings in the vicinity of the seepage pit portion of the on-site Class V injection well to assess subsurface conditions. Soil sample collection and analysis was in compliance with EPA - Region 9 \"Guidelines for Closure of Shallow Water Disposal Wells\" dated 1992. Based on laboratory analytical results of soil samples collected, the previous discharge of wash water into the seepage pit portion of the Class V injection well had not adversely effected the area investigated.","cited_authors":"BACKGROUND The subject site is an operating truck rental and leasing facility providing maintenance services to over-the-road tractor trailers and other vehicles. Vehicle and service bay floor wash water was previously discharged through a subsurface clarifier and septic tank and finally discharged into the subsurface through a seepage pit. The disposal system is defined as a Class V injection well and is the subject of this work plan. The results of the previous investigation are detailed in the attached \"Initial Site Assessment\" report (SECOR","cited_year":"1997","cited_title":"Guidelines for Closure of Shallow Water Disposal Wells","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":2406649,"raw_reference":"HYDROGEOLOGIC SETTING The site is located in the Upper Santa Ana River Ground Water Basin, and more significantly within the Chino I Subbasin. Actual and potential ground water uses in the subbasin have been designated by the California Regional Water Quality Control Board, Santa Ana Region (RWQCB), and include municipal, domestic, agricultural, industrial service and industrial process supply (RWQCB, 1983). Based on the data obtained from the Fontana Water Company (FWC), the Marygold Mutual Water Company (MMWC) and the State of California Department of Water Resources (DWR), the depth to first \"significant\" ground water is estimated to be approximately 400 feet below ground surface (bgs) in the site vicinity. The reported regional ground water flow direction is southwest (FWC, 1996, MMWC, 1996, and DWR, 1970)\". P.24 No known surface bodies of water (i.e. oceans, lakes, rivers) are located within a one-mile radius of the subject site (United States Geological Survey (USGS), 1967). The reported average annual rate of precipitation in the site vicinity is 15 inches (National Oceanic and Atmospheric","cited_authors":"HYDROGEOLOGIC SETTING The site is located in the Upper Santa Ana River Ground Water Basin, and more significantly within the Chino I Subbasin. Actual and potential ground water uses in the subbasin have been designated by the California Regional Water Quality Control Board, Santa Ana Region (RWQCB), and include municipal, domestic, agricultural, industrial service and industrial process supply (RWQCB","cited_year":"1983","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":2406650,"raw_reference":"Administration, 1982). SITE ASSESSMENT ACTIVITIES Health and Safety Plan","cited_authors":"Administration","cited_year":"1982","cited_title":"SITE ASSESSMENT ACTIVITIES Health and Safety Plan","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":2406651,"raw_reference":"SECOR International Incorporated, 1997, Initial Site Assessment, Penske Truck Leasing Facility, 14228 Slover Avenue, Fontana, California, April 7, 1997. Environmental Protection Agency, Region 9, 1992, Guidelines for Closure of Shallow Disposal","cited_authors":"SECOR International Incorporated","cited_year":"1997","cited_title":"Initial Site Assessment, Penske Truck Leasing Facility, 14228 Slover Avenue, Fontana, California, April 7, 1997","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":2406652,"raw_reference":"Wells, Revised May, 1993. P.27 FIGURES P.28 P.29","cited_authors":"Wells, Revised May","cited_year":"1993","cited_title":"P.27 FIGURES P.28 P.29","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":2406653,"raw_reference":"Administration, 1982). P.40 5.0 FIELD INVESTIGATION","cited_authors":"Administration","cited_year":"1982","cited_title":"P.40 5.0 FIELD INVESTIGATION","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":2406654,"raw_reference":"GEOPROBE BORINGS On February 20-21, 1997, Maverick Environmental Services, under the direction of SECOR completed a geophysical survey to locate underground utilities and a subsurface Class V injection well. Following die completion of the geophysical survey four push-probe soil borings (B-1, B-2, B-2A and B-2B) were advanced adjacent to the injection well (Figure 2). Soil boring B-1 was advanced to 26 feet below ground surface (bgs) along the northwest corner of the injection well. Bedrock was encountered at 26 feet bgs within boring B-1 impeding further advancement. Soil boring B-2 was advanced along the southeast corner of the injection well. Refusal was encountered at 20 feet bgs within boring B-2. SECOR relocated the geoprobe rig approximately 4 feet south of boring B-2 (boring location B-2A) to try to attain a deeper soil sample near die southern portion of tie injection well. Boring B-2A met with refusal at approximately 16 feet bgs. A fourth boring location (B-2B) was advanced approximately 5 feet southeast of the boring B-2A. Boring B-2B also met with refusal at approximately 20 feet bgs. Ground water was not encountered within any of die soil borings advanced on site. No soil cuttings were generated during soil boring activities.","cited_authors":"GEOPROBE BORINGS On February 20-21","cited_year":"1997","cited_title":"Maverick Environmental Services, under the direction of SECOR completed a geophysical survey to locate underground utilities and a subsurface Class V injection well","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":2406655,"raw_reference":"DWR (State Department of Water Resources), 1970, Meeting Water Demands in the Chino-Riverside","cited_authors":"DWR (State Department of Water Resources)","cited_year":"1970","cited_title":"Meeting Water Demands in the Chino-Riverside","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":2406656,"raw_reference":"Area, Appendix A: Water Supply, Bulletin No. 104-3; report dated September 1970.","cited_authors":"Area, Appendix A: Water Supply, Bulletin No. 104-3; report dated September","cited_year":"1970","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":2406657,"raw_reference":"FWC (Fontana Water Company), 1996, Mr. James T. Bryson, general superintendent; oral communication on June 21, 1996.","cited_authors":"FWC (Fontana Water Company)","cited_year":"1996","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":2406658,"raw_reference":"MMWC (Marygold Mutual Water Company), 1996, Mr. Bill Stafford, superintendent; oral communication on June 21, 1996. National Oceanic and Atmospheric Administration, 1982, National Climate Center, Monthly Normals of","cited_authors":"MMWC (Marygold Mutual Water Company)","cited_year":"1996","cited_title":null,"cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":2406659,"raw_reference":"Temperature, Precipitation, and Heating and Cooling Degree Days, 1951-1980, California; Climatography of the United States No. 81, dated September 1982.","cited_authors":"Temperature, Precipitation, and Heating and Cooling Degree Days","cited_year":"1951-1980","cited_title":"California; Climatography of the United States No","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":2406660,"raw_reference":"RWQCB (California Regional Water Quality Control Board, Santa Ana Region), 1983, Water Quality Control Plan, Santa Ana River Basin (8) - 1984; amended 1983.","cited_authors":"RWQCB (California Regional Water Quality Control Board, Santa Ana Region)","cited_year":"1983","cited_title":"Water Quality Control Plan, Santa Ana River Basin (8) - 1984; amended 1983","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":2406661,"raw_reference":"USGS (United States Geological Survey), 1967, Fontana Quadrangle, 7.5 minute series topographic map; dated 1967, photorevised 1980.","cited_authors":"USGS (United States Geological Survey)","cited_year":"1967","cited_title":"Fontana Quadrangle, 7.5 minute series topographic map; dated 1967, photorevised 1980","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":2406662,"raw_reference":"IUGS Subcommission on the Systematics of Igneous Rocks, 1973, Classification and Nomenclature of Plutonic Rocks: Geotimes, V.18, n.10 (Oct.), p. 26-30.","cited_authors":"IUGS Subcommission on the Systematics of Igneous Rocks","cited_year":"1973","cited_title":"Classification and Nomenclature of Plutonic Rocks: Geotimes, V.18, n.10 (Oct.), p","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"research_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null},{"citation_id":2406663,"raw_reference":"RWQCB (California Regional Water Quality Control Board, Los Angeles Region), 1996, New Information Related to the Leaking Underground Storage Tank Program, April 22, 1996, Table 4-1. d\\p\\penskc\\fontana. rpt P.45","cited_authors":"RWQCB (California Regional Water Quality Control Board, Los Angeles Region)","cited_year":"1996","cited_title":"New Information Related to the Leaking Underground Storage Tank Program, April 22, 1996, Table 4-1","cited_venue":null,"cited_doi":null,"cited_url":null,"ref_kind":"government_report","section":"refsec","page":null,"context_sentence":null,"paper_id":null,"paper_title":null,"paper_year":null,"paper_doi":null}]}