International Commission on Radiological Protection (ICRP). 2015. Occupational Intakes of Radionuclides: Part 1
Other documents for the same rulemaking (all, by stage)
References: 226 extracted, 1 linked to papers
Smith, J.R.H., Etherington, G., Youngman, M.J., 2012. An Investigation of Monitoring by Nose Blow Sampling. HPA-CRCE-030. Centre for Radiation, Chemical and Environmental Hazards, Public Health England, Chilton.
Smith, J.R.H., Birchall, A., Etherington, G., et al., 2014. A revised model for the deposition and clearance of inhaled particles in human extra-thoracic airways. Radiat. Protect. Dos. 158, 135–147.
Snyder, W.S., Ford, M.R., Warner, G.G., et al., 1969. Estimates of absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom. MIRD Pamphlet No. 5. J. Nucl. Med. 10(Suppl. 3), 46–51.
Snyder, S.F., Traub, R.J., 2010. The Livermore phantom history and supplementation. Health Phys. 98, 459–465.
Stradling, G.N., Ham, G.J., Smith, H., et al., 1978a. Factors affecting the mobility of plutonium 238 dioxide in the rat. Int. J. Radiat. Biol. 34, 37–47.
Stradling, G.N., Loveless, B.W., Ham, G.J., et al., 1978b. The biological solubility in the rat of plutonium present in mixed plutonium sodium aerosols. Health Phys. 35, 229–235.
Stradling, N., Hodgson, A., Phipps, A.W., et al., 2005. Can low doses from inhaled thorium be confirmed by personal monitoring? In: Proceedings of the 9th International Conference on Health Effects of Incorporated Radionuclides (HEIR), 29 November–1 December 2004.
Stather, J.W., Phipps, A.W., Harrison, J.D., et al., 2003. Dose coefficients for the embryo and fetus following intakes of radionuclides by the mother. Radiat. Prot. Dosim. 105, 257–264.
Strom, D.J., 2003. Eliminating bias in routine bioassay when there is an unknown time of intake. Radiat. Prot. Dosim. 105, 339–340.
Sun, L.C., Clinton, J.H., McDonald, J., et al., 1993. Urine collection protocol in the Republic of the Marshall Islands. Radiat. Prot. Manag. 10, 64–72.
Svartengren, M., Sommerer, K., Scheuch, G., 2001. Comparison of clearance of particles inhaled with bolus and extremely slow inhalation techniques. Exp. Lung Res. 27, 367–386.
Takahashi, S., Patrick, G., 1987. Long-term retention of 133Ba in the rat trachea following local administration as barium sulfate particles. Radiat. Res. 110, 321–328.
ICRP Publication 130 Takahashi, S., Kubota, Y., Sato, H., et al., 1993. Retention of 133Ba in the trachea of rabbits, dogs and monkeys following local administration of 133BaSO4 particles. Inhal. Tox. 5, 265–273.
Toohey, R.E., Essling, M.A., 1980. Measurements of 241Am in vivo at long times after inhalation. Health Phys. 38, 139–145.
Tyler, G.R., Lister, B.A.J., 1973. The biological half life of 144Ce in the human chest as determined from in vivo measurements following an accidental inhalation. In: Proceedings of the 2nd IRPA European Congress on Radiation Protection, pp. 249–253.
Wernli, C., Eikenberg, J., 2007. Twenty-year follow-up of a Pu/Am inhalation case. Radiat. Prot. Dosim. 125, 506–512.
West, C.M., Scott, L.M., 1966. A comparison of uranium cases showing long chest burden retentions. Health Phys. 12, 1545–1555.
West, C.M., Scott, L.M., 1969. Uranium cases showing long chest burden retention – an updating. Health Phys. 17, 781–791.
West, C.M., Scott, L.M., Schultz, N.B., 1979. Sixteen years of uranium personnel monitoring experience – in retrospect. Health Phys. 36, 665–669.
Whicker, J.L., 2004. Relationship of air sampling measurements to internal dose: a review. In: Proceedings of 37th Midyear Health Physics Society Meeting on Air Monitoring and Internal Dosimetry, 8–11 February 2004, Augusta, GA, USA. pp. 73–77. Available at: http://hps.org/meetings/midyear/abstract508.html (last accessed 5 May 2015).
Youngman, M.J., Smith, J.R.H., Kovari, M., 1994. The determination of thorium lung burden by measurements of thoron in exhaled air. Radiat. Prot. Dosim. 53, 99–102.
Zankl, M., Fill, U., Petoussi-Henss, N., et al., 2002. Organ dose conversion coefficients for external photon irradiation of male and female voxel models. Phys. Med. Biol. 47, 2367–2385.
Zankl, M., Petoussi-Henss, N., Fill, U., et al., 2003. The application of voxel phantoms to the internal dosimetry of radionuclides. Radiat. Prot. Dosim. 105, 539–548.
Zankl, M., Eckerman, K., Bolch, W.E., 2007. Voxel-based models representing the male and female ICRP reference adult – the skeleton. Radiat. Prot. Dosim. 127, 174–186.
HRTM described in Publication 66 (ICRP, 1994a) in the light of experience and new information. The revised version of the HRTM used in the OIR series is summarised in Section 3.2, and simple changes from the original HRTM are described. The major changes made relate to the clearance of deposited material by both particle transport and absorption into blood. These involved reviews and analyses of relevant recent information, and judgements in implementing the changes in the HRTM. These developments are described below. Changes to the model describing particle transport from the ET airways involved changes to the distribution between ET1 and ET2 of material deposited in the ET airways, which are described below. Detailed consideration given to the treatment of progeny formed in the respiratory tract is also described in this annex. A.2. Clearance: particle transport (A2) As in the original HRTM, it is assumed that particle transport rates are independent of age and sex, and the same for all materials. A generic compartment model is therefore provided to describe particle transport of all materials. It is recognised [see Annex E of Publication 66 (ICRP, 1994a)] that there are exceptions to this assumption. In particular, the clearance of some nanoparticles from the AI region may be different from the behaviour assumed in the model (see Section A.3.4).
However, it was considered that the additional complexity involved in taking account of this was not justified for radiological protection purposes. (A3) The original model is shown in Fig. A.1. Reference values of each parameter are shown in Fig. A.1 and listed in Table A.1. Reference values of rate constants were derived, as far as possible, from human studies, as particle transport rates are known to vary greatly among mammalian species. (A4) New studies enable more reliable particle transport parameter values to be chosen for the ET, BB, bb, and AI regions than was possible when Publication 66 was issued (ICRP, 1994a). (A5) The revised particle transport model adopted here is shown in Fig. A.2 (also Fig. 3.4). Reference values of each parameter are shown in Fig. A.2 and listed in