National Institute for Occupational Safety and Health (NIOSH). 2020. NIOSH Manual of Analytical Methods (NMAM), 5th Edition.
Other documents for the same rulemaking (all, by stage)
References
ASTM [2014a]. E1370-14 Standard guide for air sampling strategies for worker and workplace protection. West Conshohocken, PA: ASTM International.
ASTM [2014b]. D7338-14 Standard guide for assessment of fungal growth in buildings. West
Conshohocken, PA: ASTM International. ASTM [2014c]. D7910-14 Standard practice for collection of fungal material from surfaces by tape lift. West Conshohocken, PA: ASTM International.
ASTM [2014d]. D7788-14 Standard practice for collection of total airborne fungal structures via inertial impaction methodology. West Conshohocken, PA: ASTM International.
ASTM [2014e]. D7297-14 Standard practice for evaluating residential indoor air quality concerns. West Conshohocken, PA: ASTM International.
ASTM [2015]. ASTM D5952 - 08(2015) Standard guide for the inspection of water systems for Legionella and the investigation of possible outbreaks of legionellosis (Legionnaires' Disease or Pontiac Fever). West Conshohocken, PA: ASTM International.
ATS [1990]. American Thoracic Society. Diagnostic standards and classification of tuberculosis. Am Rev Respir Dis 142(3):725-735.
Axelsson BO, Saraf A, Larsson L [1995]. Determination of ergosterol in organic dust by gas chromatography-mass spectrometry. J Chromatogr B Biomed Sci Appl 666(1):77-84.
Babady NE, Buckwalter SP, Hall L, Le Febre KM, Binnicker MJ, Wengenack NL [2011]. Detection of Blastomyces dermatitidis and Histoplasma capsulatum from culture isolates and clinical specimens by use of real-time PCR. J Clin Microbiol 49(9):3204-3208.
Banaszak EF, Thiede WH, Fink JN [1970]. Hypersensitivity pneumonitis due to contamination of an air conditioner. N Engl J Med 283(6):271-276.
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-68 of BA-115 Sampling and Characterization of Bioaerosols
Baron EJ, Finegold SM [1990]. Bailey & Scott's Diagnostic Microbiology, 8th edition. St. Louis: Mosby.
Baron PA, Deye GJ [1990]. Electrostatic effects in asbestos sampling. I: Experimental measurements. Am Ind Hyg Assoc J 51(2):51-62.
Beaulieu HJ, Fidino AV, Arlington KL, Buchan RM [1980]. A comparison of aerosol sampling techniques: "open" versus "closed-face" filter cassettes. Am Ind Hyg Assoc J 41(10):758-765.
Bennett JW, Klich M [2003]. Mycotoxins. Clin Microbiol Rev 16(3):497-516.
Bhangar S, Adams RI, Pasut W, Huffman JA, Arens EA, Taylor JW, Bruns TD, Nazaroff WW [2016]. Chamber bioaerosol study: human emissions of size-resolved fluorescent biological aerosol particles. Indoor Air 26(2):193-206.
Blachere FM, Cao G, Lindsley WG, Noti JD, Beezhold DH [2011]. Enhanced detection of infectious airborne influenza virus. J Virol Methods 176(1-2):120-124.
Blachere FM, Lindsley WG, Pearce TA, Anderson SE, Fisher M, Khakoo R, Meade BJ, Lander O, Davis S, Thewlis RE, Celik I, Chen BT, Beezhold DH [2009]. Measurement of airborne influenza virus in a hospital emergency department. Clin Infect Dis 48(4):438-440. Blais Lecours P, Veillette M, Marsolais D, Duchaine C [2012]. Characterization of bioaerosols from dairy barns: reconstructing the puzzle of occupational respiratory diseases by using molecular approaches. Appl Environ Microbiol 78(9):3242-3248. Bolaños-Rosero B, Betancourt D, Dean T, Vesper S [2013]. Pilot study of mold populations inside and outside of Puerto Rican residences. Aerobiologia 29(4):537-543.
Bonifait L, Charlebois R, Vimont A, Turgeon N, Veillette M, Longtin Y, Jean J, Duchaine C [2015]. Detection and quantification of airborne norovirus during outbreaks in healthcare facilities. Clin Infect Dis 61(3):299-304.
Jamieson FB, Tang P, Plummer F [2005]. Detection of airborne severe acute respiratory syndrome (SARS) coronavirus and environmental contamination in SARS outbreak units. J Infect Dis 191(9):1472-1477.
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-69 of BA-115 Sampling and Characterization of Bioaerosols
Brasel TL, Douglas DR, Wilson SC, Straus DC [2005]. Detection of airborne Stachybotrys chartarum macrocyclic trichothecene mycotoxins on particulates smaller than conidia. Appl Environ Microbiol 71(1):114-122. Breuer D [2012]. Flow resistance of samplers for personal monitoring in work areas and requirements for sampling pump performance. J Occup Environ Hyg 9(2):D25-32. Brockmann JE [2011]. Aerosol transport in sampling lines and inlets. In: Kulkarni P, Baron
NJ: John Wiley & Sons. Brown RC, Hemingway MA, Wake D, Thorpe A [1996]. Electret-based passive dust sampler: sampling of organic dusts. Analyst 121(9):1241-1246.
Buiarelli F, Canepari S, Di Filippo P, Perrino C, Pomata D, Riccardi C, Speziale R [2013]. Extraction and analysis of fungal spore biomarkers in atmospheric bioaerosol by HPLC–MS–
MS and GC–MS. Talanta 105:142-151. Burge HP, Boise JR, Rutherford JA, Solomon WR [1977]. Comparative recoveries of airborne fungus spores by viable and non-viable modes of volumetric collection. Mycopathologia 61(1):27-33.
Buttner MP, Stetzenbach LD [1993]. Monitoring airborne fungal spores in an experimental indoor environment to evaluate sampling methods and the effects of human activity on air sampling. Appl Environ Microbiol 59(1):219-226.
Carvalho E, Sindt C, Verdier A, Galan C, O'Donoghue L, Parks S, Thibaudon M [2008]. Performance of the Coriolis air sampler, a high-volume aerosol-collection system for quantification of airborne spores and pollen grains. Aerobiologia 24(4):191-201.
Castillo NI, Ibanez M, Beltran E, Rivera-Monroy J, Ochoa JC, Paez-Castillo M, PosadaBuitrago ML, Sulyok M, Hernandez F [2016]. Identification of mycotoxins by UHPLC-QTOF
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-70 of BA-115 Sampling and Characterization of Bioaerosols
CDC [2003]. Guidelines for environmental infection control in health-care facilities. Recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee (HICPAC). Atlanta, GA: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, http://www.cdc.gov/hicpac/pdf/guidelines/eic_in_HCF_03.pdf.
CDC [2009]. Biosafety in microbiological and biomedical laboratories, 5th edition. Chosewood
CDC [2015]. Sampling procedure and potential sampling sites. Protocol for collecting environmental samples for Legionella culture during a cluster or outbreak investigation or when cases of disease may be associated with a facility. Atlanta, GA: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, http://www.cdc.gov/legionella/downloads/cdc-sampling-procedure.pdf.
Cella LN, Blackstock D, Yates MA, Mulchandani A, Chen W [2013]. Detection of RNA viruses: current technologies and future perspectives. Crit Rev Eukaryot Gene Expr 23(2):125137.
CEN [2000]. EN 13098:2000 Workplace atmosphere - Guidelines for measurement of airborne micro-organisms and endotoxin. Brussels, Belgium: European Committee for Standardization.
CEN [2003]. EN 14031:2003 Workplace atmospheres - Determination of airborne endotoxins.
CEN [2004]. EN 14583:2004 Workplace atmospheres - Volumetric bioaerosol sampling devices - Requirements and test methods. Brussels, Belgium: European Committee for Standardization. Chang C-W, Chou F-C [2011]. Assessment of bioaerosol sampling techniques for viable Legionella pneumophila by ethidium monoazide quantitative PCR. Aerosol Sci Technol 45(3):343-351.
Cherrie JW, Maccalman L, Fransman W, Tielemans E, Tischer M, Van Tongeren M [2011]. Revisiting the effect of room size and general ventilation on the relationship between nearand far-field air concentrations. Ann Occup Hyg 55(9):1006-1015.
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-71 of BA-115 Sampling and Characterization of Bioaerosols
Chew GL, Douwes J, Doekes G, Higgins KM, van StrienR, Spithoven J, Brunekreef B [2001]. Fungal extracellular polysaccharides, beta (1 -> 3)-glucans and culturable fungi in repeated sampling of house dust. Indoor Air 11(3):171-178. Condit RC [2007]. Principles of virology. In: Knipe DM, Howley PM, eds. Fields virology. Philadelphia: Lippincott, Williams & Wilkins.
Coons AH, Creech HJ, Jones RN [1941]. Immunological properties of an antigen containing a fluorescent group. Proc Soc Exp Biol Med 47:200-202.
Coons AH, Creech HJ, Jones RN, Berliner E [1942]. The demonstration of pneumococcal antigen in tissues by use of fluorescent antibody. J Immunol 45:159-170.
Corzo CA, Culhane M, Dee S, Morrison RB, Torremorell M [2013]. Airborne detection and quantification of swine influenza a virus in air samples collected inside, outside and downwind from swine barns. PLoS ONE 8(8):e71444.
Cown WB, Kethley TW, Fincher EL [1957]. The critical-orifice liquid impinger as a sampler for bacterial aerosols. Appl Microbiol 5(2):119-124. Cox CS [1968]. The aerosol survival of Escherichia coli B in nitrogen, argon and helium atmospheres and the influence of relative humidity. J Gen Microbiol 50(1):139-147. Cox CS [1987]. The aerobiological pathway of microorganisms. New York: Wiley. Cox CS [1989]. Airborne bacteria and viruses. Sci Prog 73(292 Pt 4):469-499.
Custis NJ, Woodfolk JA, Vaughan JW, Platts-Mills TA [2003]. Quantitative measurement of airborne allergens from dust mites, dogs, and cats using an ion-charging device. Clin Exp Allergy 33(7):986-991.
McDowell A, Iossifova Y, Bailey R, Kreiss K, Materna B [2012]. Occupational coccidioidomycosis in California: outbreak investigation, respirator recommendations, and surveillance findings. J Occup Environ Med 54(5):564-571.
Davies A, Thomson G, Walker J, Bennett A [2009]. A review of the risks and disease transmission associated with aerosol generating medical procedures. J Infect Prev 10(4):122126.
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-72 of BA-115 Sampling and Characterization of Bioaerosols
JM, Beaudoin A, Casey ML, Marriott C, Ludwig AM, Sonel AF, Muder RR, Hicks LA [2015]. The importance of clinical surveillance in detecting Legionnaires' disease outbreaks: a large outbreak in a hospital with a Legionella disinfection system-Pennsylvania, 2011-2012. Clin Infect Dis 60(11):1596-1602. Dennis PJL [1990]. An unnecessary risk: Legionnaires' disease. In: Morey PR, Feeley JC, Otten
Donaldson AI, Ferris NP, Gloster J [1982]. Air sampling of pigs infected with foot-and-mouth disease virus: comparison of Litton and cyclone samplers. Res Vet Sci 33(3):384-385.
Douwes J, Doekes G, Montijn R, Heederik D, Brunekreef B [1997]. An immunoassay for the measurement of (1 -> 3)-beta-D-glucans in the indoor environment. Mediators Inflamm 6(4):257-262.