National Institute for Occupational Safety and Health (NIOSH). 2020. NIOSH Manual of Analytical Methods (NMAM), 5th Edition.
Other documents for the same rulemaking (all, by stage)
References
PCR has both the advantage and disadvantage of not requiring that the virus be viable in order to be detected. This eliminates the need to preserve viability during and after collection and allows the use of dry collection methods such as cyclone samplers, dry impactors and filters, which are simpler and easier to carry out. On the other hand, this also means that it is unclear whether the airborne virus is infectious or not, which makes interpretation of data more difficult. This is a common criticism of PCR-based bioaerosol studies. If the virus in a bioaerosol sample is to be cultured, in most cases the sample will need to be collected into an aqueous media using an impinger or wetted surface aerosol collector. Fabian et al. [2009] showed that collecting airborne influenza virus in aqueous media using an SKC BioSampler preserved infectivity much better than dry collection using filters or an impactor. A less-common method is to collect viable viruses using an Andersen impactor. Gustin et al. [2011] collected airborne influenza virus using an Andersen impactor by placing a filter and a thin layer of gelatin on top of the agar in the culture plates. After collection, the gelatin was removed and melted at 37°C to allow
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-39 of BA-115 Sampling and Characterization of Bioaerosols Following sample collection, liquid or agar cultures are incubated at a suitable temperature and atmosphere (facultative versus aerobic) for an appropriate time. Fast-growing bacteria may develop microcolonies in hours, while fungi may take days to develop into a visible colony and perhaps sporulate. Organisms such as Mycobacterium tuberculosis or the dimorphic fungal pathogens, Histoplasma capsulatum or Blastomyces dermatitidis may require weeks of incubation to produce visible colonies [ATS 1990; Babady et al. 2011]. For fungi, plates are typically incubated at room temperature (18°C-25°C) or, if it is a clinically relevant isolate, at 35°C [ACGIH 1989; Baron and Finegold 1990; Hung et al. 2005; Macher 1999]. In contrast, environmental bacteria are grown between 18°C and 28°C, while thermophilic bacteria are grown between 50°C and 58°C [Hung et al. 2005; Macher 1999]. After allowing for vegetative growth of all viable propagules on the selected nutrient medium, the number of colonies is identified, quantified and presented as colony forming units (CFUs) [Eduard et al. 2012]. Media blanks (laboratory and field) should be processed using the same methods as samples to control for environmental or laboratory contaminants. A collection of bioaerosol identification manuals is presented in both the
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-40 of BA-115 Sampling and Characterization of Bioaerosols et al. 2011; Hung et al. 2005]. A selection of nutrient media and growth conditions that can be used for viable fungal culture can be found in Hung et al. [2005], Flannigan et al. [2011] and Macher [1999]. b. Sample preparation for viruses Because viruses are obligate intracellular parasites, special precautions must be taken in an effort to minimize damage to the collected virus-laden aerosol. Environmental factors such as humidity, temperature and gas composition of the air can significantly impact the infectiousness of a virion and should be monitored closely [Ijaz et al. 2016]. Several studies have shown that the inactivation of an airborne virus is directly related to the relative humidity and temperature [Weber and Stilianakis 2008]. In one study, high humidity levels caused a loss of infectious influenza virus from simulated coughs [Noti et al. 2013].
Similarly, using a ferret animal model, Lowen et al. [2007] demonstrated a correlation between airborne transmission of influenza and the relative humidity and temperature. Through the use of an ozone-oxygen delivery system, researchers were able to show that ozone-mediated reactive oxygen species (ROS) caused lipid peroxidation and subsequent damage to the lipid envelope and viral capsid [Murray et al. 2008]. Such studies highlight the importance of collecting viral aerosols under optimal environmental conditions and, when possible, minimizing the detrimental effects of environmental factors on collected samples. Air sampling techniques also may cause damage to the virus and compromise analysis. Before collecting viral aerosols, the hardiness of the target virus must be taken into account. Currently, there are over 200 known respiratory viruses that fall under one family of DNA viruses (Adenoviridae) and four families of RNA viruses (Orthomyxoviridae,
Paramyxoviridae, Picornaviridae and Coronaviridae) [Abed and Boivin 2006]. While all viruses package their genome in a protective protein coat known as the capsid, some viruses also possess a lipid bilayer envelope that, as the name implies, surrounds the viral capsid. Once outside the host, the viral envelope is highly sensitive to desiccation, temperature fluctuations and readily undergoes degradation. Variations in temperature can greatly affect viral enzymatic activity and nucleic acid stability [Tang 2009]. As noted earlier, viruses with lipid envelopes tend to survive better at low humidity, while nonenveloped viruses survive better at high humidity [Tang 2009]. Also, RNA viruses are inherently more unstable than DNA viruses due to the presence of the 2’-hydroxyl group on the ribose sugar molecule of RNA that is susceptible to base-catalyzed hydrolysis and degradation. Therefore it is critical that collection methods do not disrupt the lipid membrane and/or compromise the integrity of nucleic acids. Impairment of either the lipid envelope or nucleic acids can significantly impact detection of the viral aerosol and lead to false negatives.
Mycobacterium, which do not stain readily. In the acid-fast staining process, the application of heat facilitates the staining of the microorganism [Tortora et al. 2013]. b. Legionella Bacteria that are placed in the genus Legionella, are the etiological agents of pulmonary infections called Legionellosis [Fields 2002]. Legionella pneumophila (Figure 1B) is the most widely known species that has been implicated in Legionnaires’ disease, which can result in pneumonia. Milder illness with fever and body aches is referred to as Pontiac fever. Bacteria placed in this genus consist of Gram negative rods and are associated with freshwater in the environment [ASTM 2015; Macher 1999]. Exposure to warm temperatures (25-42°C) can result in the growth and proliferation of the bacteria, a problem that has emerged in water and air handling systems within the indoor built environment [Hung et al. 2005]. Growth and persistence within Protista have also been reported [Hung et al. 2005]. For health care facilities, ASHRAE Guideline 12–2000 recommends storing and distributing cold water at <20°C (68°F), whereas hot water should be stored at >60°C (140°F) and circulated with a minimum return temperature of 51°C (124°F). In other settings, hot water should be stored at ≥40°C (≥120°F) [ASHRAE
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-43 of BA-115 Sampling and Characterization of Bioaerosols 2000]. Building air conditioning cooling towers, humidifiers, or structures used for bathing such as hot tubs are particularly susceptible to Legionella amplification. Legionella can be aerosolized within water droplets via abiotic disturbance mechanisms and disseminated into the breathing zone of the subject. Airborne levels lower than 10
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-45 of BA-115 Sampling and Characterization of Bioaerosols 8 Enumeration of culturable bioaerosols a. Enumeration of bacteria and fungi The total concentration of culturable airborne microorganisms in a sample is determined by collecting the bioaerosol sample on a culture plate or plates (or inoculating culture plates with a bioaerosol sample), incubating the plates, and dividing the number of colonies observed on the culture plates by the volume of air sampled. Note that, as discussed in section 2, the number of colonies counted on an agar plate from a bioaerosol impactor must be adjusted using a positive-hole correction factor to correct for multiple microorganisms depositing beneath an impactor hole [Andersen 1958; Leopold 1988; Macher 1989]. A colony is defined as a macroscopically visible growth of microorganisms on a solid nutrient medium. Concentrations of culturable bioaerosols collected during air sampling are normally reported as colony forming units (CFU) per unit volume of air [Eduard et al. 2012]. CFUs also can be determined from samples collected in a swab or dust sample collected from the floor or area of contamination [Hung et al. 2005].
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-46 of BA-115 Sampling and Characterization of Bioaerosols Viral plaque assay A widely used approach for detecting viral pathogens and quantifying viral titers is the viral plaque assay (VPA) [Condit 2007]. Under biological safety controls, the appropriate cell line is propagated and plated, usually in a 6-well format, at a concentration at which cells form a monolayer. The cell monolayer is next treated for a defined period (30-60 minutes) with a specific volume (0.1 mL to 1.5 mL) of the collected bioaerosol and incubated at the specified temperature and CO2 levels for 24 to 72 hours. Throughout the incubation period, cells are routinely inspected and CPEs are documented. Upon completion of the incubation period, cells are chemically fixed, stained and plaques (zones of cellular clearing) are enumerated. The final concentration of the collected viral aerosols is calculated based on the number of plaques, dilution of the inoculum and volume plated, and is expressed in plaque forming units per mL (PFU/mL]). While the VPA is a cost-effective method of assessing sample viral loads, results can take anywhere from 3-5 days. Other limitations such as the inability to detect low viral titers and inactivated (noninfectious) virus and the failure of some viruses to form plaques, may compromise detection and underestimate the viral loads in an aerosol sample.
Likewise, common indoor and outdoor contaminants (such as fungi and bacteria) can impair the VPA by disrupting the cellular monolayer or outcompeting for nutrients in the cell culture medium. Tissue culture infectious dose assay Another cell culture-based approach to identifying viral aerosols is the Tissue Culture Infectious Dose assay (TCID50), also known as an endpoint dilution assay [Condit 2007]. As with the VPA, select cells are plated at a desired concentration in a 96-well format and inoculated with serial dilutions of the collected sample. Following a specified incubation period, cells are examined for CPEs. The TCID50 is defined as the dilution of virus required to infect 50% of the cell culture wells [Reed and Muench 1938]. Based on the number of cells that are infected at the designated virus dilution, viral titers are mathematically calculated. Limitations of the TCID50 are similar to those observed with the VPA. Immunofluorescence antibody (IFA) assays To enhance viral detection and quantify viral loads, immunofluorescence antibody (IFA) assays (direct or indirect) are frequently used in combination with cell culturebased methods [Flint et al. 2009a; Tortora et al. 2013]. By combining infected cells with a fluorescently-labeled, antigen-specific antibody, it is possible to increase detection levels without the lengthy incubation periods that are typically necessary with VPAs and TCID50 assays.
Similarly, the presence of certain hydrophilic species including Stachybotrys chartarum and Aspergillus versicolor, and Chaetomium globosum may be signs of indoor fungal contamination and may require immediate inspection [Flannigan et al. 2011; Hung et al. 2005]. Where local amplification and dissemination of bacteria have not occurred in an occupied, indoor environment, Gram-positive cocci (e.g., Micrococcus and Staphylococcus) are normally dominant [Morey et al. 1986]. Airborne human skin scales and respiratory secretions may contain Gram-positive cocci [ACGIH 1989; Hung et al. 2005]. Detection of high levels of these microorganisms may be an indication of over-crowding and inadequate ventilation. Indoor air that tests high for Gram-negative bacteria indicates a need to identify and eliminate the source of contamination. Concentrations ranging from 4,500-10,000 CFU/m3 have been suggested as the upper limit for ubiquitous bacterial aerosols [ACGIH 1989; Nevalainen 1989]. These exposure limits, however, do not apply to pathogenic microorganisms. Actinomycetes (mesophilic and thermophilic) are commonly found in agricultural areas. Their presence in indoor environments is an indicator of contamination [ACGIH 1989; Banaszak et al. 1970; Lacey and Crook 1988]. Thermophilic
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-51 of BA-115 Sampling and Characterization of Bioaerosols Electron Electron microscopy consists of a beam of electrons that enable structures smaller than 0.2 µm, such as viruses, to be resolved. Scanning electron microscopy (SEM) and, more recently, field emission scanning electron microscopy (FESEM), are approaches used to study the surface features of prokaryote and eukaryote cells as well as viruses (usually magnified 1,000-10,000X). These bioaerosols are immobilized onto a semisolid filter submicron membrane or in the form of a liquid suspension and a threedimensional image of the area is generated. Images from SEM can provide vital information about the size, morphology and concentration of the collected bioaerosol [Afanou et al. 2014; Eduard et al. 2012]. However, SEM does not provide information on viability of the collected bioaerosol. FESEM has been recently used to resolve fungal fragments that are produced from fungal colonies following abiotic disturbance [Afanou et al. 2015; Afanou et al. 2014]. Transmission electron microscopy can also be used to examine viruses or the internal ultrastructure in thin sections of cells (usually magnified 10,000-100,000X), although the image produced is not three- dimensional. Compared to other methods of assessment described in this chapter, SEM and
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-52 of BA-115 Sampling and Characterization of Bioaerosols than the LAL method. Similarly, chemical-based approaches are available to detect endotoxins including gas chromatography-mass spectrometry [Eduard et al. 2012]. c. Biochemical analysis methods Because of the high frequency of isolation of Gram-negative rods in clinical settings, several commercial multi-test systems have been developed for identification of members of the family Enterobacteriaceae and other pathogenic microorganisms. These microorganisms are indistinguishable except for characteristics determined by detailed biochemical testing. These systems require that a pure culture be examined and characterized. A list of some commercially available identification kits is provided in Table
III. All of these multitest systems have documented accuracies greater than 90% in clinical settings [Baron and Finegold 1990; Koneman 1988]. For fungi, API (Analytab Products,
Plainview, NY) and BIOLOG can also be used to differentiate yeasts based on the respective biochemical and physiological profiles [Flannigan et al. 2011]. d. Chemotaxonomic approaches Cellular fatty acids (CFA) of bacteria are structural in nature, occurring in the cell membrane or cell wall of all bacteria. When the bacteria are grown under standardized growth conditions, the CFA profiles are reproducible within a genus, down to the subspecies or strain level in some microorganisms. The Sherlock Microbial Identification System (MIS), developed by MIDI (Newark, DE), provides a chromatographic technique and software libraries capable of identifying various microorganisms based on their CFA composition [Sasser 1990a; Sasser 1990b]. The chromatographic technique is also known as gas chromatography fatty acid methyl ester analysis (GC-FAME). MIS has a database containing the analysis libraries for culturable Gram-negative and Gram-positive bacteria, and yeasts. In a comparison study [Amy et al. 1992], only 8 of 18 isolates, identified by either API multitest or MIDI MIS, were identified accurately using BIOLOG multitest. A prototype method for extracting and analyzing fungi is currently being distributed by
MIDI. e. Chemical-based approaches A variety of chemical-based approaches are available for the detection and quantification of bacteria and fungi in environmental samples [Flannigan et al. 2011; Hung et al. 2005]. Common approaches include thermal desorption - gas chromatography - mass spectrometry (TD-GC-MS), high performance liquid chromatography, gas chromatography-tandem mass spectrometry, and matrix-assisted laser desorption/ionization time of flight (MALDI-TOF) mass spectrometry [Flannigan et al. 2011]. These methods require the formation of a library of markers or spectral signatures that are used to discriminate between various prokaryote and eukaryote species. Examples
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-53 of BA-115 Sampling and Characterization of Bioaerosols of spectral signatures that have been used for the detection of fungi include microbial volatile organic compounds (mVOCs), mycotoxins, ergosterol, 3-hydroxy fatty acids, muramic acid as well as intracellular and extracellular proteins. NIOSH Method 2549 is a
TD-GC-MS based approach that allows for the detection of mVOCs in environmental samples [NIOSH 2003d]. f. High performance liquid chromatography High performance liquid chromatography (HPLC) is commonly used for bioaerosol “fingerprinting” and biomass determination. Techniques such as proteomics and identifying variations in chromatographic patterns can be used to determine the source of airborne material. For example, ergosterol has been used for decades to detect fungal contamination [Seitz et al. 1979] and even determine taxonomy [Axelsson et al. 1995; Pasanen et al. 1999; Schnurer 1993]. Keratin analysis can be used to identify bioaerosols derived from vertebrates and possibly the habitat within an environment [Staton et al. 2013]. Detection can be as straightforward as using UV absorbance or as complex and specific as employing an ion trap mass spectrometer.
ELISA, indirect ELISA, sandwich ELISA and competitive ELISA. The sandwich ELISA method is typically used for the detection for airborne viruses and aeroallergens [Hung et al. 2005]. In this assay, a capture antibody is bound to a solid surface, usually a 96-well plate. The bioaerosol extract is added to the plate containing the capture antibody and incubated for a specified length of time, washed with a phosphate buffer solution and probed with an enzyme-labeled antibody that enables detection and quantification, either through colorimetric changes or fluorescence emissions. The advantages to using a sandwich-based ELISA method are that it is highly specific and can be used on complex samples such as aerosols. Some disadvantages to using a sandwich-based ELISA are poor antibody recognition and/or minimal detection due to low sample concentration. Lastly, it should be noted that
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-57 of BA-115 Sampling and Characterization of Bioaerosols viable viral aerosols. Multiplexed technologies that enable the detection and quantification of multiple allergen sources in one sample are also available from a variety of commercial sources [King et al. 2013].
Similarly, flow cytometry-based approaches using fluorescent-labelled antibodies have also been employed to evaluate a variety of bioaerosol sources including bacteria, pollen and fungi [Rittenour et al. 2012; Rule et al. 2007; Rydjord et al. 2007]. Multiplexed approaches have been developed for the detection of multiple allergens in the same extracted sample [King et al. 2013].
FIA can be used to detect viruses. An example of a direct FIA assay for the detection of virus-laden aerosols is the Focus Forming Assay (FFA) [Flint et al. 2009a]. With the
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-58 of BA-115 Sampling and Characterization of Bioaerosols
HA assay, known as the Hemagglutination-Inhibition test, can be performed [Stewart et al. 1967]. The HA inhibition test measures serum antibodies that are directed against the viral pathogen. When present in sufficient concentration, the serum antibodies are able to prevent agglutination of red blood cells thereby providing an alternative means of quantifying viral loads.
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-59 of BA-115 Sampling and Characterization of Bioaerosols Direct and indirect immunostaining Direct and indirect immunostaining methods have been previously described for the detection of bioaerosol sources. Popp et al. [1988] developed a staining technique to enumerate bioaerosol samples directly captured on microscope slides. These approaches have enabled the identification of specific bioaerosol sources, especially those that do not contain morphological phenotypes that would be used by a trained microbiologist to resolve and identify a specific microorganism [Popp et al. 1988]. Alternatives to this approach have been developed and utilized in a variety of indoor and occupational environments. A press blotting approach that included immobilizing proteins from collected bioaerosols captured on an adhesive tape provided insight into the bioaerosols that contain allergen in the outdoor environment [Takahashi et al. 1993; Takahashi and Nilsson 1995]. An alternative method, called the Halogen
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-61 of BA-115 Sampling and Characterization of Bioaerosols throughput screening of multiple respiratory viruses in a single reaction mixture. It should be noted that poor assay design, primer and probe base-pair mismatches and degraded template nucleic acids can lead to false negatives or reduced detection sensitivity. Investigators should ensure optimal assay design, validate limits of detection, and run valid PCR controls in parallel. Within the last two decades, a variety of molecular technologies have been used to quantify eukaryotic biomass including fungi and plant pollen in occupational, health, residential, and industrial samples [Rittenour et al. 2012; Scott et al. 2011; Summerbell et al. 2011]. Examples of these technologies include molecular based methods to evaluate specific or conserved gene loci (internal transcribed spacer region of ribosomal RNA) such as Sanger [Rittenour et al. 2014] or next generation sequencing [Kettleson et al. 2015], denaturing gradient gel electrophoresis [Johansson et al. 2014] and quantitative PCR [Eduard et al. 2012; Vesper et al. 2007]. The latter approach includes examples such as a
DNA-based mold specific quantitative PCR (msQPCR) method that enables the detection and quantification of 36 indicator fungal species [Vesper et al. 2007]. This msQPCR method has been used to develop an Environmental Relative Moldiness Index (ERMI) to quantify the mold burden in homes. Originally developed by the U.S. Environmental Protection Agency (EPA) [Vesper et al. 2007], this approach has been licensed to a variety of companies in the commercial sector and is widely used to evaluate indoor fungal bioaerosol particles in settled dust during investigations of indoor air quality [BolañosRosero et al. 2013; Kettleson et al. 2015; Reponen et al. 2012; Reponen et al. 2011a; Taubel et al. 2016; Vesper et al. 2013; Vesper et al. 2007]. The development of this methodology has provided the first step towards a standardized approach to quantify fungal bioaerosol sources within the indoor environment. Other metagenomic molecular methods including
NIOSH does not recommend routine air sampling when investigating possible respiratory illness due to exposures in damp buildings. Instead, NIOSH recommends inspections of the building and its HVAC systems to locate moisture and microbial growth problems, followed by remediation [NIOSH 2012a].
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-65 of BA-115 Sampling and Characterization of Bioaerosols an air sampling strategy and the collection and evaluation of bioaerosols [ASTM 2009; ASTM 2014a; ASTM 2014b; ASTM 2014d; ASTM 2014e]. The Centers for Disease Control and Prevention has guidelines on environmental infection control in healthcare facilities that include recommendations on environmental sampling [CDC 2003]. Disclaimer Mention of any company or product does not constitute endorsement by NIOSH. In addition, citations to websites external to NIOSH do not constitute NIOSH endorsement of the sponsoring organizations or their programs or products. Furthermore, NIOSH is not responsible for the content of these websites. All web addresses referenced in this document were accessible as of the publication date. 13 References
Abed Y, Boivin G [2006]. Treatment of respiratory virus infections. Antiviral Res 70(2):1-16.
ACGIH [1989]. Guidelines for the assessment of bioaerosols in the indoor environment.
ACGIH [2001]. Documentation of the Threshold Limit Values and Biological Exposure Indices. Appendix C: Particle size-selective sampling criteria for airborne particulate matter.
ACGIH [2015]. TLVs and BEIs based on the documentation of the Threshold Limit Values for chemical substances and physical agents and Biological Exposure Indices. Cincinnati, OH: American Conference of Governmental Industrial Hygienists.
Adams RI, Tian Y, Taylor JW, Bruns TD, Hyvarinen A, Taubel M [2015]. Passive dust collectors for assessing airborne microbial material. Microbiome 3:46.
Adhikari A, Reponen T, Rylander R [2013]. Airborne fungal cell fragments in homes in relation to total fungal biomass. Indoor Air 23(2):142-147.
Afanou KA, Straumfors A, Skogstad A, Nayak AP, Skaar I, Hjeljord L, Tronsmo A, Eduard W, Green BJ [2015]. Indirect immunodetection of fungal fragments by field emission scanning electron microscopy. Appl Environ Microbiol 81(17):5794-5803.
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-66 of BA-115 Sampling and Characterization of Bioaerosols
Green BJ, Eduard W [2014]. Submicronic fungal bioaerosols: high-resolution microscopic characterization and quantification. Appl Environ Microbiol 80(22):7122-7130.
Amy PS, Haldeman DL, Ringelberg D, Hall DH, Russell C [1992]. Comparison of identification systems for classification of bacteria isolated from water and endolithic habitats within the deep subsurface. Appl Environ Microbiol 58(10):3367-3373. Andersen AA [1958]. New sampler for the collection, sizing, and enumeration of viable airborne particles. J Bacteriol 76(5):471-484.
Appert J, Raynor PC, Abin M, Chander Y, Guarino H, Goyal SM, Zuo ZL, Ge S, Kuehn TH [2012]. Influence of suspending liquid, impactor type, and substrate on size-selective sampling of MS2 and adenovirus aerosols. Aerosol Sci Technol 46(3):249-257.
Arantes TD, Theodoro RC, Da Graca Macoris SA, Bagagli E [2013]. Detection of Paracoccidioides spp. in environmental aerosol samples. Med Mycol 51(1):83-92.
Artenstein MS, Miller WS, Lamson TH, Brandt BL [1968]. Large-volume air sampling for meningococci and adenoviruses. Am J Epidemiol 87(3):567-577.
Artenstein MS, Miller WS, Rust JH Jr., Lamson TH [1967]. Large-volume air sampling of human respiratory disease pathogens. Am J Epidemiol 85(3):479-485.
Ashley K, Harper M [2013]. Closed-face filter cassette (CFC) sampling-guidance on procedures for inclusion of material adhering to internal sampler surfaces. J Occup Environ Hyg 10(3):D29-33.
ASHRAE [2000]. D-86815 Guideline 12-2000 -- Minimizing the risk of legionellosis associated with building water systems. Atlanta, GA: American Society of Heating, Refrigerating and Air-Conditioning Engineers.
ASHRAE [2009]. Indoor air quality guide: best practices for design, construction and commissioning. Atlanta, GA: American Society of Heating, Refrigerating and Airconditioning Engineers.
ASHRAE [2015]. ANSI/ASHRAE Standard 188-2015 Legionellosis: risk management for building water systems. Atlanta, GA: American Society of Heating, Refrigerating and AirConditioning Engineers.
NIOSH Manual of Analytical Methods 5th Edition Chapter BA March 2017 Page BA-67 of BA-115 Sampling and Characterization of Bioaerosols
ASTM [2009]. D7391-09 Standard test method for categorization and quantification of airborne fungal structures in an inertial impaction sample by optical microscopy. West
Conshohocken, PA: ASTM International. ASTM [2012]. D7789-12 Standard practice for collection of fungal material from surfaces by swab. West Conshohocken, PA: ASTM International.