Moody, Russell C. and J. Y. Liu. “Chapter 11: Glue Structural Members,” Wood handbook--Wood as an engineering material. General Technical Report FPL-GTR-113. Madison, WI: U.S. Department of Agriculture, Forest Service, Forest Products Laboratory. [A-98-44-II-I-146]
Other documents for the same rulemaking (all, by stage)
References
Smulski, S., ed. 1997. Engineered wood products, a guide to specifiers, designers and users. PFS Research Foundation. Structural Composite Lumber
ASTM. 1997a. Standard specification for evaluation of structural composite lumber products. ASTM D5456. West
Bohlen, J.C. 1972. Laminated veneer lumber—development and economics. Forest Products Journal. 22(1): 18-26.
Jung, J. 1982. Properties of parallel-laminated veneer from stress-wave-tested veneers. Forest Products Journal. 32(7): 30-35.
Kunesh, R.H. 1978. MICRO=LAM: Structural laminated veneer lumber. Forest Products Journal. 28(7): 41-44.
Laufenberg, T. 1983. Parallel laminated veneer: processing and performance research review. Forest Products Journal. 33(9):21-28.
Moody, R.C. 1972. Tensile strengui of lumber laminated from 1/8 in. thick veneers. Res. Pap. FPL-RP-181. Madison, WI: U.S. Department of Agriculture, Forest Service, Forest Products Laboratory. Figure 11-13. Cutaway to show details of sandwich construction in an experimental structure. Fire Resistance In tests at the Forest Products Laboratory, the fire resistance of wood-faced sandwich panels was appreciably greater dian uiat of hollow panels faced widi die same thickness of plywood. Fire resistance was greatly increased when coatings that intumesce on exposure to heat were applied to die core material. The spread offirethrough the honeycomb core depended to a large extent on the alignment of dieflutesin die core. In panels withflutesperpendicular to die facings, only slight spread offlameoccurred. In cores in which flutes were parallel to the length of die panel, the spread of flame occurred in die vertical direction along open channels.
NIST. 1995. Voluntary product standard PS 1-95. Construction and industrial plywood. Gaidiersburg, MD: U.S. Department of Commerce, National Institute of Standards and Technology. Press-Lam Team. 1972. Feasibility of producing a highyield laminated structural product. Res. Pap. FPL-RP-175.
AF&PA. 1997. National design specification for wood construction. Washington, DC: American Forest & Paper Association.
AITC. 1979. Recommended practice for protection of structural glued-laminated timber during transit, storage, and erection. AITC 111. Englewood, CO: American Institute of Timber Construction.
AITC. 1984. Standard appearance grades for structural gluedlaminated timber. AITC 110. Englewood, CO: American Institute of Timber Construction. P.23
AITC. 1990. Standard for preservative treatment of structural glued-laminated timber. AITC 109. Englewood, CO: American Institute of Timber Construction.
AITC. 1993a. Inspection manual. AITC 200. Englewood,
AITC. 1993b. Standard specifications for structural gluedlaminated timber of softwood species. AITC 117. Englewood, CO: American Institute of Timber Construction.
AITC. 1994. Timber construction manual. American Institute of Timber Construction. 4ui ed. New York: John Wiley & Sons.
AITC. 1996. Standard specifications for structural gluedlaminated timber of hardwood species. AITC 119. Englewood, CO: American Institute of Timber Construction.
ANSI. 1992. Structural glued laminated timber.
Moody, R.C. 1977. Improved utilization of lumber in glued laminated beams. Res. Pap. FPL-RP-292. Madison, WI: U.S. Department of Agriculture, Forest Service, Forest Products Laboratory.
Peterson, J.; Madson, G.; Moody, R.C. 1981. Tensile strengdi of one-, two-, and diree-ply glulam members of 2 by 6 Douglas-fir. Forest Products Journal. 31(1): 42-48.
Selbo, M.L.; Knauss, A.C.; Worth, H.E. 1965. After two decades of service, glulam timbers show good performance. Forest Products Journal. 15(11): 466-472.
Wolfe, R.W.; Moody, R.C. 1979. Bending strength of vertically glued laminated beams widi one to five plies. Res. Pap. FPL-RP-333. Madison, WI: U.S. Department of
APA. 1980. Plywood Design Specification. Tacoma, WA:
APA—The Engineered Wood Association. ANSI. 1996. Structural glued laminated timber for utility structures. ANSI 05.2. New York: American National Standards Institute. Supp. 1. Design and fabrication of plywood curved panels
ASCE. 1975. Wood structures, a design guide and commentary. New York: American Society of Civil Engineers. Supp. 3. Design and fabrication of plywood stressed-skin panels
ASCE. 1982. Evaluation, maintenance and upgrading of wood structures. New York: American Society of Civil Engineers. Supp. 4. Design and fabrication of plywood sandwich panels
ASTM. 1997b. Standard practice for establishing stresses for structural glued-laminated timber (glulam). ASTM D3737.
ASTM. 1997c. Standard practice for establishing structural grades and related allowable properties for visually graded lumber. ASTM D245. Philadelphia, PA: American Society for Testing and Materials.
AWPA. 1997a. Standards for solvents and formulations for organic preservative system. P9. Woodstock, MD: American Wood Preservers' Association.
AWPA. 1997b. Standards for waterbome preservatives. P5.
CSA. 1989. Structural glued-laminated timbers. CAN/CSA 0122. Rexdale, ON: Canadian Standards Association.
CSA. 1994. Engineering design of wood (limit state design).
Freas, A.D.; Selbo, M.L. 1954. Fabrication and design of glued laminated wood structural members. U.S. Department of Agriculture Tech. Bull. 1069. Available from: Englewood, CO: American Institute of Timber Construction.
Jokerst, R.W. 1981. Finger-jointed wood products. Res. Pap. FPL-RP-382. Madison, WI: U.S. Department of
APA. 1997. Performance standard for I-joists used in residential floor construction. PRI-400. Tacoma, WA: APA—The Engineered Wood Association.
ASTM. 1997d. Standard specification for establishing and monitoring structural capacities of prefabricated wood Ijoists. ASTM D5055. West Conshohocken, PA: American Society for Testing and Materials.
ASTM. 1997e. Standard mediods for testing veneer, plywood, and odier glued veneer constructions. ASTM D805. West Conshohocken, PA: American Society for Testing and Materials.
Ding, Y.; Hou, J. 1995. General buckling analysis of sandwich constructions. Computers & Structures. 55(3): 485-493.
Forest Products Laboratory. 1943. Design of plywood webs for box beams. FPL Rep. 1318. Madison, WI: U.S. Department of Agriculture, Forest Service, Forest Products Laboratory.
Kuenzi, E.W.; Zahn, J J . 1975. Stressed-skin panel deflection and stresses. Res. Pap. FPL-RP-251. Madison, WI: U.S. Department of Agriculture, Forest Service, Forest Products Laboratory.
Dawley, E.R. 1943. Buckling in shear webs of box and Ibeams andtiieireffect upon design criteria. FPL Rep. 1318B.
Lewis, W.C.; Heebink, T.B.; Cottingham, W.S. 1944. Effects of certain defects and stress concentrating factors on die strengdi of tension flanges of box beams. FPL Rep. 1513. Madison, WI: U.S. Department of Agriculture, Forest
Service, Forest Products Laboratory. Lewis, W.C.; Heebink, T.B.; Cottingham, W. S. 1945. Effect of increased moisture on the shear strength at glue lines of box beams and on the glue-shear and glue-tension strengtiis of small specimens. FPL Rep. 1551. Madison,
McNatt, J.D. 1980. Hardboard-webbed beams: Research and application. Forest Products Journal. 30(10): 57-64.
Orosz, I. 1970. Simplified method for calculating shear deflections of beams. Res. Note FPL-RN-0210. Madison,
Superfesky, M.J.; Ramaker, T J . 1976. Hardboard-webbed I-beams subjected to short-term loading. Res. Pap. FPLRP-264. Madison, WI: U.S. Department of Agriculture, Forest Service, Forest Products Laboratory.
Superfesky, M.J.; Ramaker, T J . 1978. Hardboard-webbed I-beams: Effects of long-term loading and loading environment. Res. Pap. FPL-RP-306. Madison, WI: U.S. Department of Agriculture, Forest Service, Forest Products Laboratory.
Timoshenko, S. 1961. Theory of elastic stability. 2d ed. New York: McGraw-Hill. Structural Sandwich Construction C394-88. Shear fatigue of sandwich core materials C480-88. Flexure-creep of sandwich constructions C481-88. Laboratory aging of sandwich constructions
Cheng, S. 1961. Torsion of sandwich plates of trapezoidal cross section. Journal of Applied Mechanics, American Society of Mechanical Engineers Transactions. 28(3): 363-366.
Hall, R.B. 1996. Performance limits for stiffness-critical graphitic foam structures. Pt. II. Comparisons of foams, foam-core and honeycomb-core sandwiches in bending/shear. Journal of Composite Materials. 30(17): 1938-1956.
Holmes, CA. 1978. Room corner-wall fire tests of some structural sandwich panels and components. Journal of Fire and Flammability. 9: 467-488.