Methane Emissions from the Natural Gas Industry, Volume 9: Underground Pipelines
Other documents for the same rulemaking (all, by stage)
References
Institute, GRI-9310115, April 1993. Radian Corporation, Program Plan for the Cooperative Leak Test Program, prepared for Gas Research Institute, March 1993. Washington State University, University of New Hampshire, and Aerodyne
Leaks, Environmental Science & Technology. December 1994. Code of Regulations. Title 40, Part 60, Appendix A, Method 5, Section 7.2. National Archives and Records Administration, Office of the Federal Register,
July I, 1995. SAS Institute Inc., SAS~ Procedures Guide, Version 6, Third Edition, Cary,
NC: SAS Institute Inc., 1990. SAS Institute Inc., SAS/STAT~ User's Guide, Version 6, Founh Edition, Volume 2, Cary, NC: SAS Institute Inc., 1989. U.S. Department of Transportation. Research and Special Programs
Administration, 1991. Southern Cross Corporation. Comments on Docket PS-123 Notice I, Leakage
Surveys, 49 CFR Part 192, Department of Transportation, Research and Special Programs Administration, Materials Transportation Bureau, Office of Pipeline Safety Regulations, December 19, 1991. Palisade Corporation, @Risk, Risk Analysis and Simulation Add-in for Lotus 12-3. Version 1.5, March 1989. American Gas Association, Gas Facts, 1992.
Stapper, B.E. Methane Emissions from the Natural Gas Industry, Volume 5: Activity Factors, Final Report, GRI-9410257.22 and EPA-600/R-96-080e. Gas Research Institute and U.S. Enviromnental Protection Agency, June 1996.
SCF/leak-hour. The Shapiro-Wilk W statistic, generated by the SAS UNIVARIATE (SAS, 1990) procedure, was used to determine whether the nontransformed and natural
OUTLIER Maximum: 4.1109 (ID 2002) inside bounds: -4.3850 to 6.3571 not an outlier Minimum: -4.8283 (ID 2014) inside bounds: -8.7334 to 9.3532 not an outlier Maximum: 4.1109 (ID 2002) inside bounds: -8.7334 to 9.3532 not an outlier Maximum: 4.1109 (ID 2002) Minimum: -4.8283 (ID 2014) Dixon Maximum: 4.1109 (ID 2002) Minimum: F-Spread Conservative Approach a The criteria are based on the 5% significance level for the Grubbs and Dixon tests
LOGARITHMS OF THE FLOW RATES Test ID Number Standard Flow Rate (SCF/leak-hour) Natural Log of Standard Flow Rate 2014 0.008 -4.8283 3020 0.700 -0.3567 3019 1.130 0.1222 3039 I.620 0.4824 I 1002 10.266 2.3288 2002 61.000 4.1109 Mean 12.454 0.309894 Standard Deviation 24.084 3.014434 log-transformed plastic pipe data were nonna!Iy distributed. For the nontransformed data, the W-statistic was 0.6068 and the associated p-valu~ was 0.0001, indicating that the nontransformed data were not normally distributed. However, for the natural log-transformed data, the W-statistic was 0.9396 and the associated p-value was 0.6747, indicating that the natural log-transformed data were normally distributed, within random variability. Because of the small sample size (6), however, this test is not highly sensitive. Small or moderate deviations from normality might not be detected based on a hypothesis test with this sample size. Figure A-1 Shows the frequency histogram for the nontransformed data and Figure A-2 shows the frequency histogram for the natural logtransformed data to illustrate the results suggested by the W-statistics. The nontransformed data are obviously skewed and not normally distributed, while the natural log-transformed data are much more symmetric and appear to be closer to the normal distribution.
Gilbert, Richard 0., 1987: Statistical Methods for Environmental Pollution Monitoring. Van Nostrand Reinhold, New York, 320 pp.
Grubbs, Frank E., 1969: Procedures for detecting outlying observations in samples.
Technometrics, 11, No. 1, I -21. A-11 Hoaglin, D.C., F. Mosteller, and J.W. Tukey, 1983: Understanding Robust and Exploratory Data Analysis. John Wiley & Sons, Inc., New York, 447 pp.
Hunt, W.F., Jr., G. Akland, W. Cox, T. Curran, N. Frank, S. Goranson, P. Ross, H. Sauls, and J. Suggs, 1981: U.S. Environmental Protection Agency Intra-Agency Task Force on Air Quality Indicators, EPA-450/4-81-015 (NTIS PB81-!77982). Office of Air Quality Planning and Standards, Research Triangle Park, NC.
NS! Technology Services Corporation, 1989: WHO and WMO Program Documentation. Prepared for Environ. Monitoring Systems Laboratory, U.S. EPA, Research Triangle Park,
SAS Institute, Inc., 1990: SAS* Procedures Guide, Version 6, Third Edition. Cary, NC:
Bureau, Office of Pipeline Safety Regulations, December 19, 1991.
Report, GRI-94/0257.22 and EPA-600/R-96-080e. Gas Research Institute and U.S. Environmental Protection Agency, June 1996. B-14
RE.PORT OATE. June 1996 PERFORMING OAGAN!ZATCON CODE.