Policy Replication

Air Quality Criteria Document for Oxides of Nitrogen, EPA-600/8-91/049aF-cF, August 1993. (NTIS} [A-95-27-II-A-1]

Docket document2023-11-20 · EPA · publication · EPA-HQ-OAR-2005-0167-0201
RIN 2060-AI23, RIN 2060-AI12 · Docket EPA-HQ-OAR-2005-0167

Other documents for the same rulemaking

1999-01-01 Regulatory impact analysisRegulatory Impact Analysis - Control of Air Pollution from New Motor Vehicles Tier 2 Motor Vehicle Emissions Standards and Gasoline Sulfur Control Requirements
1999-01-01 Regulatory impact analysisRegulatory Impact Analysis Control of Air Pollution From New Motor Vehicles Tier 2 Motor Vehicle Emissions Standards and Gasoline Sulfur Control Requirements {Draft}
1999-05-13 Federal RegisterControl of Air Pollution From New Motor Vehicles: Proposed Tier 2 Motor Vehicle Emissions Standards and Gasoline Sulfur Control Requirements
1999-10-22 Federal RegisterControl of Emissions of Air Pollution From 2004 and Later Model Year Highway Engines and Vehicles; Revision of Light-duty Truck Definition
1999-10-27 Federal RegisterControl of Air Pollution from New Motor Vehicles: Proposed Tier 2 Motor Vehicle Emissions Standards and Gasoline Sulfur Control Requirements
1999-10-29 Federal RegisterControl of Emissions of Air Pollution From 2004 and Later Model Year Heavy-Duty Highway Engines and Vehicles; Revision of Light-Duty Truck Definition
1999-12-07 Federal RegisterReopening of Comment Period for Control of Emissions of Air Pollution from 2004 and Later Model Year Highway Engines and Vehicles; Revision of Light-duty Truck Definition
2000-01-01 Regulatory impact analysisRegulatory Impact Analysis: Control of Emissions of Air Pollution from Highway Heavy-Duty Engines
2000-02-10 Federal RegisterControl of Air Pollution From New Motor Vehicles: Tier 2 Motor Vehicle Emissions Standards and Gasoline Sulfur Control Requirements
2000-10-06 Federal RegisterControl of Emissions of Air Pollution from 2004 and Later Model Year Heavy-Duty Highway Engines and Vehicles; Revision of Light-Duty On-Board Diagnostics Requirements
2002-12-06 Federal RegisterControl of Air Pollution From New Motor Vehicles: Amendments to the Tier 2 Motor Vehicle Emission Regulations
2002-12-06 Federal RegisterControl of Air Pollution from New Motor Vehicles: Amendment to the Tier 2 Motor Vehicle Emission Regulations; Proposed Rule
2010-02-19 Federal RegisterTier 2 Light-Duty Vehicle and Light-Duty Truck Emission Standards and Gasoline Sulfur Control Requirements (Section 610 Review)
2020-12-30 Docket documentThe Response of Regional Ozone to voe and NOx Emissions Reductions: An Analysis for the Eastern United States Based on Regional Oxidant Modeling S.H. Chu, E.L. Meyer, W.M. Cox, R.D. Scheffe. [A-95-27-II-A-6]
2020-12-30 Docket documentDraft Final Report Benefits of Reducing Mobile Source NOx Emissions prepared for U.S. EPA by ICF, Inc., 9-30-96 [A-95-27-IV-A-3]
2020-12-30 Docket documentTranscript from EPA Hearing held August 12, 1996, at the Ypsilanti Marriott re"Control of Emissions of Air Pollution from Highway Heavy-Duty Engines. [A-95-27-IV-F-1]
2021-05-12 Docket documentTier 2 (Phase 2) Study To Assess Further Reduction in Light-Duty Vehicle and Light-Duty Truck Tailpipe Emission Standards; Notice of Availability and Notice of Public Workshop [A-97-10 II-C-01]
2021-05-12 Docket documentLegacy Index for Docket A-97-10
2021-09-13 Regulatory impact analysisDraft Regulatory Impact Analysis "Control of Air Pollution from New Motor Vehicles: Tier 2 Motor Vehicle Emissions Standards & Gasoline Sulfur Control Requirements [A-97-10 III-B-01]
2021-09-13 Docket documentL. Wyborny "FCC Additive Technology Update," presented at Oil & Gas Journal International Catalyst Conference & Exhibition by GRACE Davison [A-97-10 II-G-341]
2021-09-13 Docket documentJ. Koupal, OMS: Development of Light-Duty Emission Inventory Estimates in Final Rulemaking for Tier 2 & Sulfur Standards [A-97-10 IV-B-62]
2021-09-13 Docket document6-15-99 discussion with J. Crnko, ANTEK Instruments [E. Pickell, Office of Enforcement & Compliance Assurance (OECA) [A-97-10 IV-E-02]
2021-09-13 Docket document6-15-99 discussion with P. Cecil, Sievers Instruments [E. Pickell, OECA][A-97-10 IV-E-03]
2021-09-13 Docket document5-2S-99 meeting with auto industry representatives [S. Willis, OMS] [A-97-10 IV-E-06]
2021-09-13 Docket documentD. Korotney, EPA, to docket re Calculation of Tier I Vehicle Cost-Effectiveness in Terms of $/Ton NOx+HC [A-97-10 II-B-03]
2021-09-13 Docket documentD. Brzezinski, EPA, re: A Modified Version of MOBILE5 for Evaluation of Proposed Tier 2 Evaporative Emission Standards (includes diskette) [A-97-10 II-B-11]
2021-09-14 Docket document7-20-99 meeting with Alliance of Automobile Manufacturers [J. Guy][A-97-10 IV-E-09]
2021-11-16 Regulatory impact analysisFinal Regulatory Impact Analysis [A-97-10 V-B-01]
2021-11-16 Docket documentM. Delaney, OAR/OPAR: 11-10-99 meeting with representatives of USPIRG/D. Aurbuckle, OMB/OIRA, et al. [A-97-10 IV-E-54]
2021-11-16 Docket documentFinal Regulatory Language [A-97-10-V-A-02] Final Rule Regultory Language [A-97-10-V-A-02]
2021-11-16 Docket documentSigned Final Rule Preamble [A-97-10 V-A-01]
2021-11-16 Docket documentResponse to Comments Document [A-97-10 V-C-01]
2021-11-16 Docket documentM. Oge, Director, OMS, re meeting with Alliance of Automobile Manufacturers [A-97-10 IV-E-10]
2021-11-16 Docket documentG. Passavant, EPCD: 9-21-99 meeting with Marathon-Ashland re: low sulfur gasoline [A-97-10 IV-E-17
2021-11-16 Docket documentE. Pickell, OECA: 9-29-99 meeting with National Petrochemical & Refiner's Association (NPRA) [A-97-10 IV-E-22]
2021-11-16 Docket documentT. Wysor, OMS: 11-4-99 meeting with Williams Alaska Petroleum, Inc. [A-97-10 IV-E-30]
2021-11-16 Docket documentK. Simon, OMS: 11-17-99 meeting with Alliance of Automobile Manufacturers [A-97-10 IV-E-33]
2021-11-16 Docket documentC. Lieske, EPCD: 12-2-99 meeting with Alliance of Automobile Manufacturers (Alliance) Vehicles Over 8,500 Pounds GVWR [A-97-10 IV-E-47]
2021-11-16 Docket documentK. Simon, OMS: 12-3-99 meeting with Alliance of Automobile Manufacturers (AAM) [A-97-10 IV-E-51]
2021-11-16 Docket document7-29-99 meeting with Alliance of Automobile Manufacturers [J. Guy] [A-97-10 IV-E-07]
2021-11-16 Docket documentT. Wysor, EPCD: 8-18-99 meeting with Nissan Motor [A-97-10 IV-E-16]
2021-11-16 Docket documentS. Willis, FSSG: 8-2-99 meeting with Sinclair Oil [A-97-10 IV-E-21]
2021-11-16 Docket documentK. Simon, EPA: 11-19-99 meeting with AAM/OMB [A-97-10 IV-E-55]
2021-11-16 Docket documentK. Simon, OMS: 11-5-99 meeting with Alliance of Automobile Manufacturers [A-97-10 IV-E-31]
2021-11-16 Docket documentK. Simon, OMS: 12-14-99 meeting with Navistar/OMB [A-97-10 IV-E-50]
2021-11-16 Docket document7-29-99 meeting wit General Motors, Honda, Toyota & Nissan (J. Guy) [A-97-10 IV-E-08]
2021-11-16 Docket documentM. Oge, OMS: 11-9-99 meeting with State Environmental Commissioners [A-97-10 IV-E-28]
2021-11-16 Docket document7-29-99 meeting with Exxon & Texas Natural Resources Conservation Commission (R. Moran) [A-97-10 IV-E-11]
2021-11-16 Docket documentD. deRoeck, OAQPS: 9-27-99 meeting with Natural Resources Defense Council & Clean Air Task Force [A-97-10 IV-E-37]
2021-11-16 Docket documentK. Simon, EPA: 12-6-99 meeting with environmental organizations/OMB [A-97-10 IV-E-57]
2021-11-16 Docket document6-22-99 call with Exxon [R. Moran, OMS] [A-97-10 IV-E-05]
2021-11-16 Docket documentK. Simon, OMS: 10-26-99 meeting with Association of International Automobile Manufacturers [A-97-10 IV-E-26]
2021-11-16 Docket documentC. Lieske, EPCD: 12-9&10-99 meeting with Alliance/Vehicles Over 8,500 Pounds GVWR [A-97-10 IV-E-48]
2021-11-16 Docket documentM. Delaney, OAR/OPAR: 11-10-99 meeting with American Petroleum Institute & National Petroleum Refiners Association [A-97-10 IV-E-40]
2021-11-16 Docket document8-3-99 meeting with B. Harnett, OAQPS, and National Petroleum Council [R. Moran][A-97-10 IV-E-12]
2021-11-16 Docket documentK. Simon, OMS: 10-21-99 meeting with NPRA & American Petroleum Institute (API) [A-97-10 IV-E-23]
2021-11-16 Docket documentC. Edwards, OAQPS: 10-13-99 meeting with American Petroleum Institute & National Petroleum Refineries Association [A-97-10 IV-E-36]
2021-11-16 Docket documentG. Passavant, OTAQ: 8-21,23-00 conference call with P. Krueger, NPM, "GPA Gasoline in Nevada" [A-97-10 IV-E-59]
2021-11-16 Docket documentK. Simon, OMS: 11-16-99 meeting with United Refining [A-97-10 IV-E-32]
2021-11-16 Docket documentD. deRoeck, OAQPS: 9-29-99 call with State & Territorial Air Pollution Program Administrators (STAPPA) & Association of Local Air Pollution Control Officials (ALAPCO) (Moran, EPCD) [A-97-10 IV-E-20]

References: 3,185 extracted, 0 linked to papers

Page 6Download these results: CSV · JSON
NO (Schiff et al., 1986; Spicer et al., 1991). Also, the instmment has shown sensitivity to
government reportNot linked to a paper · refsec
PAN (Wendel et al., 1983; Sickles, 1987), different sensitivities to HONO (Rickman et al., 1989; Spicer et al., 1991), and nonlinear response to N0 2 (Schiff et al., 1986; KeUy et al., 1990; Spicer et al., 1991). Furthermore, the method has shown appreciable sensitivity to an operating temperature that can be resolved by controUing the temperature of the reaction cell or by signal processing (Schiff et al., 1986; Bubacz et al., 1987). Recent tests of the CLM (luminol) instmment have demonstrated the need to conect results for pressure (as might be 6-17 P.32 seen in akborne appUcations), nonlinearity of response below 3 ppb N0 2 , interferences from 0 3 and PAN, and the age-dependent sensitivity of the luminol solution (KeUy et al., 1990).
government reportNot linked to a paper · refsec
Lastly, a manufacturer-suppUed 0 3 scmbber designed to eUminate the 0 3 interference was also found to remove appreciable amounts of N0 2 . 6.3.3 Photofragmentation/Two-Photon Laser-Induced Fluorescence Two N0 2 sensors based on measurement of fluorescence of excited N0 2 have been reported by Fincher et al. (1978). One device employs a smaU, high-pressure xenon arc flash lamp to excite N0 2 . This device has a sensitivity of 10 ppb for an 80-s (i.e., 1,024 flash-lamp pulses) integration time. The other device uses a 442-nm O F and a
research reportNot linked to a paper · refsec
MDL of 20 ppt has been reported using an artificial Ught source and a 9.2-km path length (Johnston and McKenzie, 1984).
research reportNot linked to a paper · refsec
Noxon (1978) used the sun as a Ught source and the stmcture in the N0 2 absorption spectmm near 440 nm to obtain measures of the abundance of N0 2 in both the troposphere and the stratosphere. Piatt and Pemer (1983) have reported the appUcation of DOAS to the determination of several nitrogen-containing species. A xenon high-pressure lamp or an incandescent lamp was used with a 1- to 10-km path length. Selected appUcable compounds, detection Umits, and target wavelengths are NO, 400 ppt, and 226 nm; N0 2 , 100 ppt, and 363 nm; HONO, 20 ppt, and 354 nm; and N0 3 , 0.5 ppt, and 662 nm. The DOAS technique has been recently adapted to employ a 25-m multipass open reflection system with a path length of up to 2 km (Biermann et al., 1988). Using a 0.8-km path length and 12-min averaging times, MDLs and accuracies for N0 2 , 6-20 P.35
government reportNot linked to a paper · refsec
HONO, and N0 3 of 4 ppb (±10%), 0.6 ppb (±30%), and 20 ppt (±15%), respectively, have been reported. Common remote sensing techniques employ Ught detection and ranging (Udar). Differential absorption Udar is a long-path absorption technique. This method employs Ught of two wavelengths propagated over a given distance at a given intensity. The concentration of the gas species of interest is related to the difference in intensities of the two wavelengths at the receiver. Differential absorption Udar techniques have been appUed to the ambient measurement of both NO (Alden et al., 1982) and N0 2 (Fredriksson and Hertz, 1984; Edner et al., 1987). Baumgartner et al. (1979) reported a 5-ppb sensitivity for N0 2 , and Staehr et al. (1985) reported a 10-ppb sensitivity for N0 2 using a laser source and a 6-km path length. Differential absorption Udar methods are in the development stages for momtoring N0 2 in ambient atmospheres. 6.3.5 Wet Chemical Methods Most wet chemical methods for measuring N0 2 involve the coUection of N0 2 in solution foUowed by a colorimetric finish using an azo dye. Many variations of this method exist, including both manual and automated versions.
research reportNot linked to a paper · refsec
Szonntagh (1979) traced the history of azo dye methods for N0 2 sampling and analysis. Nitrogen dioxide, fkst coUected in aqueous solution, is thought to form HONO. An aromatic amine is used in the presence of an acid to react with HONO and form a diazomum salt. The salt then rearranges and couples with another organic amine that has been added to form a red azo dye. The intensity of the color
research reportNot linked to a paper · refsec
Methods, the resulting nitrite may be determined with a spectrophotometer after reaction with sutfanUamide and either NEDA or ANSA. Although recoveries of 80 to 90% were found at N0 2 concentrations between 20 and 350 ppb using fritted bubblers, only 50% recovery was found using orifice bubblers. Because the requirement of a fritted rather than an orifice bubbler was considered to be a major disadvantage by the EPA, the development of this method as an Equivalent Method was terminated (Purdue and Hauser, 1980). Triethanolamine has been used as the coUection medium for many active and passive techniques to sample N0 2 . Although colorimetry may be used as the analytical finish, IC recently appears to be the method of choice (MUler, 1984). Vinjamoori and Ling (1981) have used an aqueous solution of TEA, ethylene glycol, and acetone on 13X molecular sieves to sample ak in the workplace for N0 2 . Passive devices employing TEA have been used for industrial hygiene and indoor ak quaUty sampUng (Palmes et al., 1976; WaUace and Ott, 1982) as weU as for ambient appUcations (Sickles and Michie, 1987; Mulik and WiUiams, 1987). Recently, a method using Whatman GF/B filters coated with an aqueous solution of
research reportNot linked to a paper · refsec
TEA, ethylene glycol, and acetone has been developed for extended sampling of both N0 2 and S0 2 from ambient ak (Sickles et al., 1990). This method, using IC to determine the coUected N0 2 as mtrite and nitrate, showed no interferences from NO, NH3, 0 3 , H2S, 6-24 P.39 methanethiol (CH3SH), and carbon disulfide (CS^, but showed major interferences from
research reportNot linked to a paper · refsec
PAN and HONO. Recovery of N0 2 averaged 87% in laboratory tests at concentrations between 5 and 400 ppb. Using two coated 47-mm diameter filters in series, filter temperatures above 5 °C, and flow rates below 2 L/min are requked to insure good N0 2 coUection efficiency. This method has been incorporated into the design of a prototype sampler known as a transition flow reactor (TFR) system for measuring acidic deposition components (Knapp et al., 1986). 6.3.6 Other Active Methods Several other methods reported for the determination of N0 2 include ionization spectroscopy, mass spectrometry, photothermal detection, denuders, and soUd sorbents.
research reportNot linked to a paper · refsec
Space Administration, 1983). This method is in the early stages of development. Atmospheric pressure ionization mass spectrometry has been investigated for the continuous measurement of N0 2 and S0 2 in ambient ak (Benoit, 1983). An MDL of approximately 0.5 ppb was reported. Methods employing photothermal detection of N0 2 have been reported (Poizat and
research reportNot linked to a paper · refsec
Recently, Adams et al. (1986) found activated manganese dioxide to be effective under unspecified RH for removing N0 2 in denuder appUcations. Additional tests are needed under conditions representative of the ambient envkonment before this approach is ready for routine appUcation.
research reportNot linked to a paper · refsec
Lipari (1984) has used a commerciaUy avaUable cartridge containing the sorbent FlorisU (magnesium sUicate) coated with diphenylamine to sample N0 2 in ambient and indoor ak. The N0 2 reacts with the diphenylamine to form nitro- and nitroso-derivatives, which are subsequently detected by high performance Uquid chromatography (HPLC)-UV. Although no interference from NO, 0 3 , S0 2 , HN0 3 , and water vapor were found, PAN produced a 50% positive interference, and HONO was expected to interfere quantitatively. Sorbent temperature must be held below 32 °C to prevent volatilization of the diphenylamine and nonquantitative sampUng. An MDL of 0.1 ppb for a 2.0-m ak sample was claimed. The method shows promise for the sensitive determination of N0 2 under conditions where the noted interferents and temperature sensitivity do not pose problems. 6-26 P.41 6.3.7 Passive Samplers Passive samplers are frequently used in industrial hygiene, indoor ak, and personal exposure studies, and are less frequently used in ambient ak sampUng. Passive NO samplers were described in Section 6.2.4. Namiesnik et al. (1984) have provided a good overview of passive samplers. The basis for aU passive samplers is the same. The gaseous analyte
government reportNot linked to a paper · refsec
HONO, HN0 3 , and PAN (Sickles, 1987). These results suggest that nitration plates may be useful only as quaUtative indicators of ambient levels of NOx. Another open-surface device has been proposed by Kosmus (1985) for ambient appUcations. This device uses chromatographic paper in the shape of a candle that is coated with diphenylamine and is continuaUy impregnated with a potassium thiocyanate-glycerin catalyst. Nitrogen oxides, presumably N0 2 and NO to some extent, are coUected by a catalyzed reaction with diphenylamine to form the nitrosamine. After extraction, the nitrosamine may be determined with a spectrophotometer or by differential pulse polarigraphy. Interference by kon oxide particles was noted, and interference from both
research reportNot linked to a paper · refsec
NO concentration and the flow rates entering the dynamic titration system are known accurately, the N0 2 concentration leaving the system can be determined accurately. The accuracy and stabiUty of NO standard gas cylinders are described in Section 6.2.5. A thkd source of N0 2 sometimes used for caUbration is a cylinder of compressed gas containing N0 2 , usuaUy in N2 (Fehsenfeld et al., 1987; Davis, 1988). CaUbrations are subsequently performed using dynamic dUution with zero ak. These cylinders are commerciaUy avaUable, and the N0 2 concentration should be referenced to an accepted standard.
research reportNot linked to a paper · refsec
Bennett (1979) has shown that, of 26 aluminum cylinders initiaUy containing suppUer-certtfied concentrations of N0 2 in N2 between 100 and 300 ppb, 10 showed modest declines in N0 2 concentration during the first 3 mo after preparation. The N0 2 levels in aU 26 cylinders declined substantiaUy over the 10-mo study period. Schiff et al. (1983) have noted problems handling trace concentrations of N0 2 from a cylinder. A cylinder containing 9 ppm N0 2 in N2 gave 15 % higher readings for N0 2 when analysis was performed by CLM than by TDLAS (Walega et al., 1984). This discrepancy may have been due to an impurity (e.g., HN03) in the cylinder that could act as an interference with the CLM, but not the
research reportNot linked to a paper · refsec
Davis (1988) examined a cylinder containing 44 ppm N0 2 in ak at regular intervals over 3 years and observed a 16% change in concentration. In view of these findings, caution should be exercised tf a cylinder containing N0 2 in N2 or ak is to be employed as a caUbration source of N0 2 . 6.3.9 Intercomparisons Several intercomparisons of research-grade N0 2 instmmentation have been conducted (Helas et al., 1981; Walega et al., 1984; Sickles et al., 1990; Fehsenfeld et al., 1987, 1990; Gregory et al., 1990b) and are described in this section. Also, the performance of EPADesignated Methods, based on intercomparisons and other studies, is discussed in Section 6.3.10. 6-31 P.46 Helas et al. (1981) report the results of a field intercomparison of several N0 2 methods conducted in April 1979 at Deuselbach, Germany. Good agreement between a highly sensitive CLM instmment and long-path absorption was found over the 1- to 8-ppb range of observed N0 2 concentrations. Walega et al. (1984) report comparisons of N0 2 measurements from a highly sensitive
government reportNot linked to a paper · refsec
TDLAS system. Measurements of N02-spiked synthetic ak conducted both in the laboratory and in the field showed good agreement. Measurements were made of ambient and captive ak in downtown Los Angeles and showed maximum respective concentrations of 100 and 600 ppb. ChemUuminescence results were appreciably higher than those of the TDLAS: this difference averaged 18% in the ambient-ak studies and 15% in the captive-ak studies. In the latter studies, the agreement was generaUy within 10% in the morning, but by the end of the day, could be as large as 80%. This behavior was attributed to the reaction of NO*, and the accumulation of photochemicaUy produced CLM interferents such as PAN that occuned during the day. DaUy N0 2 concentrations determined by TDLAS, CLM (luminol), and PSDs were reported recently from a 13-day study conducted at Research Triangle Park, NC, in the faU of 1986 (Bubacz et al., 1987; Mulik and WiUiams, 1987; Sickles et al., 1990). CoUocated sampUng was performed using a TDLAS system, two CLM (luminol) instmments, and tripUcate daUy PSDs. DaUy average results were computed for the TDLAS, each CLM (luminol) instmment, and the PSDs. The 13-day average values from the CLM (luminol) instmments and the TDLAS system agreed to within 2 ppb; the average daUy ratios of N0 2 by CLM (luminol) to TDLAS were 1.01 ± 0.11 (standard deviation) and 1.19 ± 0.17; the respective correlation coefficients were high, 0.94 and 0.91; and although the results of one
research reportNot linked to a paper · refsec
PAN results at N0 2 levels above 0.3 ppb. An 0 3 scmbber added to a second CLM (luminol) instmment removed the 0 3 interference, but faUed to remove PAN and appeared to remove substantial amounts (i.e., 50%) of N0 2 . Removal of N0 2 in the manufacturersuppUed 0 3 scmbber has also been reported by KeUy et al. (1990). Tunable-diode laser spectroscopy results compared favorably with CLM-PC at relatively high N0 2 levels (i.e., >0.4 ppb), but displayed a high bias (i.e., factor of 5) at lower N0 2 concentrations (Fehsenfeld et al., 1987). No interferences or artifacts were found for the CLM-PC results. 6-33 P.48 An akborne intercomparison (i.e., CITE 2) of N0 2 measurements was conducted by
research reportNot linked to a paper · refsec
NASA using TDLAS, PF/TP-LLF, CLM-PC, and CLM (with FeS0 4 converter) researchgrade instmments (Gregory et al., 1990b). SampUng flights were performed primarily in the free troposphere, and N0 2 concentrations were below 200 ppt and generaUy below 100 ppt. High biases (i.e., factors of 2 to 3) apparently resulting from PAN interferences were present in results from the CLM instmment with the FeS04 converter, and results from this instmment were not considered in subsequent analyses. At concentrations below 200 ppt, results from the remaining three instmments were highly correlated (i.e., conelation coefficients ranged from 0.84 to 0.95) and displayed a general level of agreement to within 30 to 40%. The PF/TP-LLF results were higher than those of the CLM-PC, and the TDLAS results were the lowest. At concentrations below 50 ppt, the results were poorly correlated, although the PF/TP-OF and CLM-PC results agreed to within 20 ppt. Below 50 ppt,
research reportNot linked to a paper · refsec
TDLAS results were much higher than those of the other two instmments. This bias, simUar to that observed in the ground-based intercomparison of Fehsenfeld et al. (1990), was enhanced at low N0 2 concentrations by an enor in the data reduction protocol employed in both studies. 6.3.10 Designated Methods Acceptable sampling and analysis methodologies for N0 2 have been specified by the
research reportNot linked to a paper · refsec
EPA (Code of Federal Regulations, 1987b). These designated methods are termed "Reference" or "Equivalent". In 1973, the original Federal Reference Method for N0 2 , the Jacobs-Hochheiser Technique, was withdrawn because of technical deficiencies (Purdue and
government reportNot linked to a paper · refsec
Hauser, 1980). In 1976, the measurement principle and the associated caUbration procedure on which Reference Methods for N0 2 must be based were specified. The measurement principle is gas-phase chemUuminescence and the caUbration procedure may employ either
research reportNot linked to a paper · refsec
GPT of an NO standard with 0 3 or an N0 2 permeation device (Code of Federal Regulations, 1987a). Because only the measurement principle and caUbration procedures appUcable to N0 2 Reference Methods were specified, different analyzers can be buUt and designated as Reference Methods, provided they meet the performance specifications shown in Table 6-1 (Code of Federal Regulations, 1987b). 6-34 P.49
datasetNot linked to a paper · refsec
NO = Nitric oxide. NH3 = Ammonia. H 2 0 = Water. Source: Code of Federal Regulations (1987b). To be designated as an Equivalent Method, the candidate method must be based on measurement principles dtfferent from the Reference Method and meet certain performance specifications (Code of Federal Regulations, 1987b). An Equivalent Method may be either 6-35 P.50 manual or automated. To be designated as Equivalent, a candidate manual method must demonstrate comparabUity, as shown in Table 6-2, with the Reference Method when appUed simultaneously to a real atmosphere. A candidate automated method must meet the performance specifications shown in Table 6-1 and demonstrate comparabUity as shown in Table 6-2 with the Reference Method when appUed simultaneously to a real atmosphere.
datasetNot linked to a paper · refsec
FOR NITROGEN DIOXIDE Nitrogen Dioxide Concentration Range (ppm) 0.02 to 0.08 Medium 0.10 to 0.20 High 0.25 to 0.35 Maximum Discrepancy Specification (ppm) 0.02 0.02 Source: Code of Federal Regulations (1987b). Methods designated by the EPA as Reference and Equivalent are identified in Table 6-3 (Federal Register, 1986). DetaUed descriptions of these and other methods for N0 2 are presented in previous subsections. Studies were conducted to provide a basis for the designation of methods by the EPA. Tests were performed to compare the performance of
newsNot linked to a paper · refsec
CLM, continuous colorimetric, manual sodium arsenite, and manual TGS methods (Purdue and Hauser, 1980). The methods were compared by measuring N0 2 in spiked and unspiked ambient ak simultaneously. QuadmpUcate samples were taken for the two manual methods and dupUcate analyzers were used for the two continuous methods. The N0 2 spikes were varied randomly from day to day over the sampling schedule and ranged from 0 to 430 ppb. Agreement both within and between methods was good: the average difference was never greater than 4 ppb. Conelation coefficients for between-method comparisons exceeded 0.985 in aU cases. No between-method differences could be attributed to concentrations of
research reportNot linked to a paper · refsec
PARS data were examined for 1983 through 1986 (Rhodes and Evans, 1988). The results, shown in Table 6-4 as 95 % probabUity Umits, suggest that the precision of continuous N0 2 analyzers faUs in the range of ± 10 to 15 %, whereas the manual methods are much worse, at ±20 to 50%. It should be noted that the manual precision results show a recent worsening. This trend may reflect the phasing out of manual methods in the network that was completed by the end of 1986. The tabulated probabUity Umits for accuracy of continuous N0 2 analyzers are ±20%, whereas for the manual methods, they are ±3 to 7% (Rhodes and Evans, 1988). The accuracy results reflect audits of the analysis portion of the manual methods and audits of both sampling and analysis for the continuous methods. Thus, the apparent difference in accuracy may be reflecting differences in the auditing procedures employed.
datasetNot linked to a paper · refsec
R. (1986) Development ofa Mn02-coated, cylindrical denuder for removing N 0 2 from atmospheric samples. Atmos. Environ. 20: 1211-1215.
journal articleNot linked to a paper · refsec
Alden, M.; Edner, H.; Svanberg, S. (1982) Laser momtoring of atmospheric NO using ultraviolet differential-absorption techniques. Opt. Lett. 7: 543-545.
journal articleNot linked to a paper · refsec
Anlauf, K. G.; Fellin, P.; Wiebe, H. A.; Schiff, H. I.; Mackay, G. I.; Braman, R. S.; Gilbert, R. (1985) A comparison of three methods for measurement of atmospheric nitric acid and aerosol nitrate and ammomum. Atmos. Environ. 19: 325-333.
journal articleNot linked to a paper · refsec
Anlauf, K. G.; Wiebe, H. A.; Fellin, P. (1986) Characterization of several integrative sampling methods for nitric acid, sulphur dioxide and atmospheric particles. J. Air Pollut. Control Assoc. 36: 715-723.
journal articleNot linked to a paper · refsec
I. (1988) Measurement of atmospheric nitric acid by the filter method and comparisons with the tuneable diode laser and other methods. Atmos. Environ. 22: 1579-1586.
journal articleNot linked to a paper · refsec
Appel, B. (1973) A new and more sensitive procedure for analysis of peroxybenzoyl nitrate. J. Air Pollut. Control Assoc. 23: 1042-1044.
journal articleNot linked to a paper · refsec
Appel, B. R.; Tokiwa, Y. (1981) Atmospheric particulate nitrate sampling errors due to reactions with particulate and gaseous strong acids. Atmos. Environ. 15: 1087-1089.
journal articleNot linked to a paper · refsec
M. (1977) Interference in 2,4-xylenol procedure for nitrate determination in atmospheric aerosols. Environ. Sci. Technol. 11: 189-190.
journal articleNot linked to a paper · refsec
Appel, B. R.; Wall, S. M.; Tokiwa, Y.; Haik, M. (1979) Interference effects in sampling particulate nitrate in ambient air. Atmos. Environ. 13: 319-325.
journal articleNot linked to a paper · refsec
Appel, B. R.; Wall, S. M.; Tokiwa, Y.; Haik, M. (1980) Simultaneous nitric acid, particulate nitrate and acidity measurements in ambient air. Atmos. Environ. 14: 549-554.
journal articleNot linked to a paper · refsec
Appel, B. R.; Tokiwa, Y.; Haik, M. (1981) Sampling of nitrates in ambient air. Atmos. Environ. 15: 283-289.
journal articleNot linked to a paper · refsec
L. (1984) Artifact particulate sulfate and nitrate formation on filter media. Atmos. Environ. 18: 409-416.
journal articleNot linked to a paper · refsec
L. (1988) Loss of nitric acid within inlet devices intended to exclude coarse particles during atmospheric sampling. Atmos. Environ. 22: 2535-2540.
journal articleNot linked to a paper · refsec
W. (1990) Comparison of atmospheric nitrous acid measurements by annular denuder and differential optical absorption systenis. Atmos. Environ. Part A 24: 611-616.
journal articleNot linked to a paper · refsec
Atkinson, R.; Winer, A. M.; Pitts, J. N., Jr. (1986) Estimation of mght-time N 2 0 5 concentrations from ambient N 0 2 and N 0 3 radical concentrations and the role of N2O5 in mght-time chemistry. Atmos. Environ. 20: 331-339.
journal articleNot linked to a paper · refsec
Atlas, E. (1988) Evidence for ^C3 alkyl nitrates in rural and remote atmospheres. Nature (London) 331: 426-428. 6-72 P.87
journal articleNot linked to a paper · refsec
K. (1984) Extractive spectrophotometric method for the determination of atmospheric nitrogen dioxide. Atmos. Environ. 18: 989-993.
journal articleNot linked to a paper · refsec
Benner, C. L.; Eatough, D. J.; Eatough, N. L.; Bhardwaja, P. (1987) Evaluation of an annular denuder method for the collection of atmospheric nitrogenous species in the southwest desert. Presented at: 80th annual meeting of the Air Pollution Control Association; June; New York, NY. Pittsburgh, PA: Air Pollution Control Association; paper no. 87-63.6.
research reportNot linked to a paper · refsec
C. (1988) Diffusion coefficients for ambient mtric and nitrous acids from denuder experiments in the 1985 nitrogen species methods comparison study. Atmos. Environ. 22: 1669-1672.
journal articleNot linked to a paper · refsec
I. (1979) Stability evaluation of ambient concentrations of sulfur dioxide, nitric oxide, and nitrogen dioxide contained in compressed gas cylinders. Research Triangle Park, NC: U.S. Environmental Protection Agency, Environmental Monitoring and Support Laboratory; EPA report no. EPA 600/4-79-006. Available from: NTIS, Springfield, VA; PB-292749.
research reportNot linked to a paper · refsec
M. (1983) Detection of nitrogen and sulfur dioxides in the atmosphere by atmospheric pressure ionization mass spectrometry. Anal. Chem. 55: 2097-2099.
journal articleNot linked to a paper · refsec
Bhatty, M. K.; Townshend, A. (1971) Spectrophotometric determination of small amounts of nitrate and nitrite by conversion to nitrotoluene and extraction into toluene. Anal. Chim. Acta 56: 55-60.
journal articleNot linked to a paper · refsec
← PreviousNext →