Air Quality Criteria Document for Oxides of Nitrogen, EPA-600/8-91/049aF-cF, August 1993. (NTIS} [A-95-27-II-A-1]
Other documents for the same rulemaking
References: 3,185 extracted, 0 linked to papers
R. (1989) Chamber and isotope techniques. In: Andreae, M. O.; Schimel, D. S., eds. Exchange of trace gases between terrestrial ecosystems and the atmosphere. New York, NY: John Wiley & Sons; pp. 175-187. (Bernhard, S., ed. Life sciences research reports: 47).
C. (1988) An artifact in the measurement of N 2 0 from combustion sources. Geophys. Res. Lett. 15: 1369-1372.
Noxon, J. F.; Norton, R. B.; Marovich, E. (1980) NO3 in the troposphere. Geophys. Res. Lett. 7: 125-128.
H. (1977) Oxidant measurements in western power plant plumes. Volume I: technical analysis. Volume U: data. Palo Alto, CA: Electric Power Research Institute; report no. EPRI EA-421. Volume H available from: NTIS, Springfield, VA; DE82-901024. 5-63 P.12
D. (1986) Surface ozone distributions and variations from 1973-1984 measurements at the NOAA geophysical monitoring for climatic change baseline observatories. J. Geophys. Res. [Atmos.] 91: 5229-5236.
C. (1986) Background ozone and anthropogenic ozone enhancement at Niwot Ridge, Colorado. J. Atmos. Chem. 4: 63-80.
A. (1991) Changing ozone: evidence for a perturbed atmosphere. Environ. Sci. Technol. 25: 631-635.
Perner, D.; Greenberg, J.; Noxon, J. F.; Schmeltekopf, A.; Winkler, P.; Zimmerman, P. (1991) The interaction of natural hydrocarbons and N 0 3 above the canopy. J. Atmos. Chem.: in press.
Pitts, J. N., Jr. (1987) Nitration of gaseous polycyclic aromatic hydrocarbons in simulated and ambient urban atmospheres: a source of mutagenic nitroarenes. Atmos. Environ. 21: 2531-2547.
R. (1978) Photooxidation of aliphatic amines under simulated atmospheric conditions: formation of nitrosamines, nitramines, amides, and photochemical oxidant. Environ. Sci. Technol. 12: 946-953.
Pitts, J. N., Jr.; Winer, A. M.; Aschmann, S. M.; Carter, W. P. L.; Atkinson, R. (1985) Experimental protocol for detennining hydroxyl radical reaction rate constants: estimation of atmospheric reactivity. Research Triangle Park, NC: U.S. Environmental Protection Agency, Atmospheric Sciences Research Laboratory;
Piatt, U.; Perner, D.; Schroeder, J.; Kessler, C ; Toennissen, A. (1981) The diurnal variation of NO3. J. Geophys. Res. C: Oceans Atmos. 86: 11965-11970.
Rodhe, H. (1990) A comparison of the contribution of various gases to the greenhouse effect. Science (Washington, DC) 248: 1217-1219.
R. (1985) The dynamics of nitric acid production and the fate of nitrogen oxides. Atmos. Environ. 19: 893-903.
B. (1987) Reactive nitrogen in the troposphere: chemistry and transport of NO x and PAN. Environ. Sci. Technol. 21: 320-327.
L. (1981) Peroxyacetyl nitrate (PAN) in the unpolluted atmosphere: an important reservoir for nitrogen oxides. Geophys. Res. Lett. 8: 941-944.
C. (1985) Relationship between peroxyacetyl nitrate and nitrogen oxides in the clean troposphere. Nature (London) 318: 347-349.
J. (1986) On the depletion of Antarctic ozone. Nature (London) 321: 755-758.
W. (1982) Nitrogen oxide reactions in the urban plume of Boston. Science (Washington, DC) 215: 1095-1097.
F. (1978) Investigations of nitrogen oxides within the plume of an isolated city. New York, NY: Coordinating Research Council, Inc.; report no.
F. (1979) Ozone sources and transport in the northeastern United States. Environ. Sci. Technol. 13: 975-985.
M. (1981) Trace nitrogen chemistry during the Philadelphia oxidant data enhancement study (1979). Research Triangle Park, NC: U.S. Environmental Protection Agency, Office of Air Quality Planning and Standards; contract no. 68-02-3338.
R. (1981) Smog chamber studies of NO x chemistry in power plant plumes. Atmos. Environ. 15: 2353-2365.
G. (1983) The mechanism of N 0 3 and HONO fonnation in the nighttime chemistry of the urban atmosphere. J. Geophys. Res. C: Oceans Atmos. 88: 6673-6682.
C. (1991) Nylon production: an unknown source of atmospheric nitrous oxide. Science (Washington, DC) 251: 932-934.
M. (1987) Reaction of chlorine nitrate with hydrogen chloride and water at Antarctic stratospheric temperatures. Science (Washington, DC) 238: 1258-1260.
M. (1988a) Antarctic ozone depletion chemistiy: reactions of N 2 0 5 with H 2 0 and HCl on ice surfaces. Science (Washington, DC) 240: 1018-1021.
M. (1988b) Heterogeneous interactions of chlorine nitrate, hydrogen chloride, and nitric acid with sulfuric acid surfaces at stratospheric temperatures. Geophys. Res. Lett. 15: 847-850.
C. (1987) Models and observations of the impact of natural hydrocarbons on rural ozone. Nature (London) 329: 705-707.
Tuazon, E. C ; Atkinson, R.; Plum, C. N.; Winer, A. M.; Pitts, J. N., Jr. (1983) The reaction of gas phase N 2 0 5 with water vapor. Geophys. Res. Lett. 10: 953-956.
Tuazon, E. C.; Carter, W. P. L.; Atkinson, R.; Winer, A. M.; Pitts, J. N., Jr. (1984) Atmospheric reactions of N-nitrosodimethylamine and dimethylnitramine. Environ. Sci. Technol. 18: 49-54.
Environmental Protection Agency. (1976) Assessment of scientific information on nitrosamines: report of an ad hoc study group of the Science Advisory Board Executive Committee.
J. (1977) On the relationship between high ozone in the rural surface layer and high pressure systems. Atmos. Environ. 11: 967-983.
Wayne, R. P.; Barnes, I.; Biggs, P.; Bunows, J. P.; Canosa-Mas, C. E.; Hjorth, J.; Le Bras, G.; Moortgat, G. K.; Perner, D.; Poulet, G.; Restelli, G.; Sidebottom, H. (1991) The mtrate radical: physics, chemistry, and the atmosphere. Atmos. Environ. Part A 25: 1-203.
Westberg, H.; Sexton, K.; Roberts, E. (1981) Transport of pollutants along the western shore of Lake Michigan. J. Air Pollut. Control Assoc. 31: 385-388. 5-65
H. (1977) NO x -0 3 photochemistry in power plant plumes: comparison of theory with observation. Environ. Sci. Technol. 11: 995-1000.
Winer, A. M.; Atkinson, R.; Pitts, J. N., Jr. (1984) Gaseous nitrate radical: possible nighttime atmospheric sink for biogenic organic compounds. Science (Washington, DC) 224: 156-159.
B. (1988) Interactions between HCl,
Wolff, E. W.; Mulvaney, R.; Oates, K. (1989) Diffusion and location of hydrochloric acid in ice: implications for polar stratospheric clouds and ozone depletion. Geophys. Res. Lett. 16: 487-490.
World Meteorological Organization. (1991) Scientific assessment of ozone depletion: 1991. Geneva, Switzerland: World Meteorological Organization; global ozone research momtoring project report no. 25.
J. (1989) On the mitigation of non-C02 greenhouse gases. Washington, DC: U.S. Department of Energy; report no. UCRL-101523. Available from: NTIS, Springfield, VA; DE89016659.
E. (1989) The role of atmospheric chemistry in climate change. JAPCA 39: 22-28. 5-66 P.15
CLM instmments, no or very smaU (i.e., less than 2%) interferences have been reported for 6 chlorine-containing species (Joshi and Bufalini, 1978), 14 sutfiir-containing species (Sickles and Wright, 1979), 7 nitrogen-containing species, and 3 sulfur-containing species (Grosjean and Harrison, 1985b). Zafkiou and Tme (1986), however, do report interferences from hydrogen sulfide (H2S) and from gases purged from anoxic waters that may have contained sulfur compounds. Using research-grade CLM instmments, Fahey et al. (1985a) found no
NO interference for N0 2 , HN0 3 , N 2 0 5 , and PAN and negUgible responses for NH3, hydrogen cyanide (HCN), N 2 0, methane (CH4), and nine chlorine-containing and three sulfur-containing compounds. These findings are consistent with those of Dmmmond et al. (1985), who report no or negUgible NO interferences from N0 2 , HN0 3 , PAN, H0 2 N0 2 , hydrogen peroxide (H 2 0 2 ), propylene, H 2 0, and aerosols using a research-grade instmment with a humidified 0 3 source. P.19 From an operational perspective, aerosols can accumulate on the glass filter separating the reaction chamber from the PM tube, causing a reduction in sensitivity (Klapheck and
TP-LJJF NO field measurements performed on an akcraft. Also, the TP-LIF technique is expected to be highly specific because it has two levels of spectroscopic selectivity. If some trace atmospheric compound were to produce an NO molecule by interaction with the 226-nm beam, then an opportunity for interference exists. Potential interference from HN0 3 , nitromethane, nitroethane, CH3ON02, N0 2 , PAN, HONO, sulfur dioxide (SO^, and CH3ONO has been evaluated. Only the last compound was found to show potential interference, and arguments have been given to neglect its influence when sampling tropospheric ak (Davis et al., 1987). 6.2.3 Absorption Spectroscopy Absorption spectroscopy encompasses techniques that measure the change in radiance from a source that occurs as a result of absorption by analyte molecules over a known path length. Several techniques, including Fourier transform IR spectroscopy (FTIR), long-path absorption, and IR tunable-diode laser spectroscopy (TDLAS), have been employed for measuring the concentration of various NOx in the atmosphere (National Aeronautics and
CV-990 flown out of CaUfornia and HawaU. The thkd intercomparison involved 13 flights sampUng tropical, nontropical, maritime, and continental ak masses at altitudes between 150 and 5,000 m. The two CLM instmments were of simUar design (Kley and McFarland, 1980), with the main differences being the injection of water vapor to the akstream entering the reaction chamber of one instmment to minimize the background variabUity caused by changing ambient humidity and to suppress an 03-related background signal. In the first study, measurements of ambient NO concentrations ranged from 10 to 60 ppt and of
NO-enriched ambient ak ranged from 20 to 170 ppt. Agreement among the techniques at the 95% confidence level was ±30%, and no artifact or species interferences were identified. In the second and thkd studies, NO concentrations ranged from below 5 ppt to above 100 ppt, with the majority below 20 ppt. At NO concentrations below 20 ppt, measurements agreed to within stated instrument precision and accuracy (i.e., to within 15 to 20 ppt). Good conelation was observed between CLM and TP-OF measurements. The authors concluded that equaUy vaUd measurements of ambient NO can be expected from either instmment. A field intercomparison of instmments designed to measure NO, NOx, and NOy was conducted near Boulder, CO (Fehsenfeld et al., 1987). The study was performed to compare the performance of instmments that employed different approaches to reduce NOx or NOy to
NO CONCENTRATION (ppm) Figure 6-1. Absolute error in nitrogen dioxide (A N0 2 ) for 10 s in the dark sampling line. Source: Butcher and Ruff (1971). including CLM, OF, absorption spectroscopy, and bubbler and passive coUection with subsequent wet chemical analysis. 6.3.1
NO detector, a converter, plumbing modifications, and changes in signal processing are requked. Several methods have been employed to reduce N0 2 to NO (KeUy, 1986). They include catalytic reduction using heated molybdenum or stainless steel, reaction with CO over a gold catalyst surface, reaction with kon sulfate (FeS04) at room temperature, reaction with carbon at 200 °C, and photolysis of N0 2 to NO at 320 to 400 nm. Because CLM is designated by the EPA as the Reference Method for N0 2 in ambient ak (Code of Federal Regulations, 1987a), CLM instmments for the determination of N0 2 are readUy avaUable commerciaUy. As noted previously, these instmments are used to measure both NO and N0 2 . Nominal detection Umits of approximately 5 ppb and response times on the order of minutes are claimed by suppUers. Field evaluation of nine instmments has shown the MDLs to range from 5 to 13 ppb (Michie et al., 1983; HoUand and McEkoy, 1986). Recent field and laboratory evaluation of two commercial instmments operated on a 0.00- to 0.05-ppm range revealed detection Umits of between 0.5 and 1.0 ppb and operating precision estimates of ±0.3 ppb (Rickman et al., 1989). Although these performance parameters are adequate for momtoring NO and N0 2 in urban and suburban envkonments, they may be inadequate in less poUuted remote areas. As noted in Section 6.2.1, efforts have been reported by several researchers to improve the sensitivity and response of CLM
PAN. A detaUed description of the operation (including minimization of interferent decomposition and both homogeneous and heterogeneous oxidation of NO) and performance of a CLM-PC instmment is given by Ridley et al. (1988). An artifact identified with this method is caused by nitrate-containing aerosols deposited on the surface of the photolysis tube that release NO and N0 2 upon irradiation (Bollinger et al., 1984). This interference is eUminated by filtering sampled ak and periodic cleaning of tube surfaces. The methods discussed above employ CLM detection of NO and are continuous. Other researchers have employed various methods of integrated sampling foUowed by a CLM instmment for measuring NO and N0 2 in the desorbed sample. GaUagher et al. (1985) have used cryosampling of stratospheric whole ak samples, and Braman et al. (1986) have used copper (I) iodide coated denuder tubes to sample N0 2 in ambient ak. 6-16 P.31 6.3.2